| #pragma once |
| |
| #include <DEMManufacturerDelegate.h> |
| #include <app/clusters/device-energy-management-server/device-energy-management-server.h> |
| #include <app/util/config.h> |
| |
| namespace chip { |
| namespace app { |
| namespace Clusters { |
| namespace DeviceEnergyManagement { |
| |
| /** |
| * The application delegate. |
| */ |
| class DeviceEnergyManagementDelegate : public DeviceEnergyManagement::Delegate |
| { |
| public: |
| DeviceEnergyManagementDelegate(); |
| |
| void SetDeviceEnergyManagementInstance(DeviceEnergyManagement::Instance & instance); |
| |
| void SetDEMManufacturerDelegate(DEMManufacturerDelegate & deviceEnergyManagementManufacturerDelegate); |
| |
| chip::app::Clusters::DeviceEnergyManagement::DEMManufacturerDelegate * GetDEMManufacturerDelegate(); |
| /** |
| * |
| * Implement the DeviceEnergyManagement::Delegate interface |
| * |
| */ |
| |
| /** |
| * @brief Implements a handler to begin to adjust client power |
| * consumption/generation to the level requested. |
| * |
| * Note callers must call GetPowerAdjustmentCapability and ensure the return value is not null |
| * before calling PowerAdjustRequest. |
| * |
| * @param power Milli-Watts the ESA SHALL use during the adjustment period. |
| * @param duration The duration that the ESA SHALL maintain the requested power for. |
| * @return Success if the adjustment is accepted; otherwise the command SHALL be rejected with appropriate error. |
| */ |
| chip::Protocols::InteractionModel::Status PowerAdjustRequest(const int64_t powerMw, const uint32_t durationS, |
| AdjustmentCauseEnum cause) override; |
| |
| /** |
| * @brief Make the ESA end the active power adjustment session & return to normal (or idle) power levels. |
| * The ESA SHALL also generate an PowerAdjustEnd Event and the ESAState SHALL be restored to Online. |
| * |
| * @return It should report SUCCESS if successful and FAILURE otherwise. |
| */ |
| chip::Protocols::InteractionModel::Status CancelPowerAdjustRequest() override; |
| |
| /** |
| * @brief The ESA SHALL update its Forecast attribute with the RequestedStartTime including a new ForecastID. |
| * |
| * If the ESA supports ForecastAdjustment, and the ESAState is not UserOptOut and the RequestedStartTime is after |
| * the EarliestStartTime and the resulting EndTime is before the LatestEndTime, then ESA SHALL accept the request |
| * to modify the Start Time. |
| * A client can estimate the entire Forecast sequence duration by computing the EndTime - StartTime fields from the |
| * Forecast attribute, and therefore avoid scheduling the start time too late. |
| * |
| * @param requestedStartTime The requested start time in UTC that the client would like the appliance to shift its power |
| * forecast to. |
| * @param cause Who (Grid/local) is triggering this change. |
| * |
| * @return Success if the StartTime in the Forecast is updated, otherwise the command SHALL be rejected with appropriate |
| * IM_Status. |
| */ |
| chip::Protocols::InteractionModel::Status StartTimeAdjustRequest(const uint32_t requestedStartTimeUtc, |
| AdjustmentCauseEnum cause) override; |
| |
| /** |
| * @brief Handler for PauseRequest command |
| * |
| * If the ESA supports FA and the SlotIsPauseable field is true in the ActiveSlotNumber |
| * index in the Slots list, and the ESAState is not UserOptOut then the ESA SHALL allow its current |
| * operation to be Paused. |
| * |
| * During this state the ESA SHALL not consume or produce significant power (other than required to keep its |
| * basic control system operational). |
| * |
| * @param duration Duration that the ESA SHALL be paused for. |
| * @return Success if the ESA is paused, otherwise returns other IM_Status. |
| */ |
| chip::Protocols::InteractionModel::Status PauseRequest(const uint32_t durationS, AdjustmentCauseEnum cause) override; |
| |
| /** |
| * @brief Handler for ResumeRequest command |
| * |
| * If the ESA supports FA and it is currently Paused then the ESA SHALL resume its operation. |
| * The ESA SHALL also generate a Resumed Event and the ESAState SHALL be updated accordingly to |
| * reflect its current state. |
| * |
| * @return Success if the ESA is resumed, otherwise returns other IM_Status. |
| */ |
| chip::Protocols::InteractionModel::Status ResumeRequest() override; |
| |
| /** |
| * @brief Handler for ModifyForecastRequest |
| * |
| * If the ESA supports FA, and the ESAState is not UserOptOut it SHALL attempt to adjust its power forecast. |
| * This allows a one or more modifications in a single command by sending a list of modifications (one for each 'slot'). |
| * Attempts to modify slots which have already past, SHALL result in the entire command being rejected. |
| * If the ESA accepts the requested Forecast then it SHALL update its Forecast attribute (incrementing its ForecastID) |
| * and run the revised Forecast as its new intended operation. |
| * |
| * *** NOTE *** for the memory management of the forecast object, see the comment before the mForecast delaration below. |
| * |
| * @param forecastID Indicates the ESA ForecastID that is to be modified. |
| * @param slotAdjustments List of adjustments to be applied to the ESA, corresponding to the expected ESA forecastID. |
| * @return Success if the entire list of SlotAdjustmentStruct are accepted, otherwise the command |
| * SHALL be rejected returning other IM_Status. |
| */ |
| chip::Protocols::InteractionModel::Status |
| ModifyForecastRequest(const uint32_t forecastID, |
| const DataModel::DecodableList<Structs::SlotAdjustmentStruct::DecodableType> & slotAdjustments, |
| AdjustmentCauseEnum cause) override; |
| |
| /** |
| * @brief Handler for RequestConstraintBasedForecast |
| * |
| * The ESA SHALL inspect the requested power limits to ensure that there are no overlapping elements. The ESA |
| * manufacturer may also reject the request if it could cause the user’s preferences to be breached (e.g. may |
| * cause the home to be too hot or too cold, or a battery to be insufficiently charged). |
| * If the ESA can meet the requested power limits, it SHALL regenerate a new Power Forecast with a new ForecastID. |
| * |
| * @param constraints Sequence of turn up/down power requests that the ESA is being asked to constrain its operation within. |
| * @return Success if successful, otherwise the command SHALL be rejected returning other IM_Status. |
| */ |
| chip::Protocols::InteractionModel::Status |
| RequestConstraintBasedForecast(const DataModel::DecodableList<Structs::ConstraintsStruct::DecodableType> & constraints, |
| AdjustmentCauseEnum cause) override; |
| |
| /** |
| * @brief Handler for CancelRequest |
| * |
| * The ESA SHALL attempt to cancel the effects of any previous adjustment request commands, and re-evaluate its |
| * forecast for intended operation ignoring those previous requests. |
| * |
| * If the ESA ForecastStruct ForecastUpdateReason was already `Internal Optimization`, then the command SHALL |
| * be rejected with FAILURE. |
| * |
| * If the command is accepted, the ESA SHALL update its ESAState if required, and the command status returned |
| * SHALL be SUCCESS. |
| * |
| * The ESA SHALL update its Forecast attribute to match its new intended operation, and update the |
| * ForecastStruct.ForecastUpdateReason to `Internal Optimization` |
| * |
| * @return Success if successful, otherwise the command SHALL be rejected returning other IM_Status. |
| */ |
| chip::Protocols::InteractionModel::Status CancelRequest() override; |
| |
| // ------------------------------------------------------------------ |
| // Overridden DeviceEnergyManagement::Delegate Get attribute methods |
| |
| ESATypeEnum GetESAType() override; |
| bool GetESACanGenerate() override; |
| ESAStateEnum GetESAState() override; |
| int64_t GetAbsMinPower() override; |
| int64_t GetAbsMaxPower() override; |
| const DataModel::Nullable<Structs::PowerAdjustCapabilityStruct::Type> & GetPowerAdjustmentCapability() override; |
| const DataModel::Nullable<Structs::ForecastStruct::Type> & GetForecast() override; |
| OptOutStateEnum GetOptOutState() override; |
| |
| // ------------------------------------------------------------------ |
| // Overridden DeviceEnergyManagement::Delegate Set attribute methods |
| CHIP_ERROR SetESAState(ESAStateEnum) override; |
| |
| // Local Set methods |
| CHIP_ERROR SetESAType(ESATypeEnum); |
| CHIP_ERROR SetESACanGenerate(bool); |
| CHIP_ERROR SetAbsMinPower(int64_t); |
| CHIP_ERROR SetAbsMaxPower(int64_t); |
| CHIP_ERROR SetPowerAdjustmentCapability(const DataModel::Nullable<Structs::PowerAdjustCapabilityStruct::Type> &); |
| CHIP_ERROR SetPowerAdjustmentCapabilityPowerAdjustReason(const PowerAdjustReasonEnum); |
| |
| // The DeviceEnergyManagementDelegate owns the master copy of the ForecastStruct object which is accessed via GetForecast and |
| // SetForecast. The slots field of forecast is owned and managed by the object that implements the DEMManufacturerDelegate |
| // interface. The slots memory MUST exist for the lifetime of the forecast object from where it is referenced. |
| // |
| // The rationale for this is as follows: |
| // It is envisioned there will be one master forecast object declared in DeviceEnergyManagementDelegate. When |
| // constructed, the field DataModel::List<const Structs::SlotStruct::Type> slots will be empty. |
| // |
| // The EVSEManufacturerImpl class (examples/energy-management-app/energy-management-common/include/EVSEManufacturerImpl.h) is |
| // an example implementation that a specific vendor can use as a template. It understands how the underlying energy appliance |
| // functions. EVSEManufacturerImpl inherits from DEMManufacturerDelegate |
| // (examples/energy-management-app/energy-management-common/include/DEMManufacturerDelegate.h) which is a generic interface |
| // and how the DeviceEnergyManagementDelegate class |
| // (examples/energy-management-app/energy-management-common/src/DeviceEnergyManagementDelegateImpl.cpp) communicates from the |
| // generic cluster world to the specific appliance implementation (EVSEManufacturerImpl). |
| // |
| // EVSEManufacturerImpl understands the slot structures of the appliance and configures the slot structures as follows: |
| // |
| // Call DeviceEnergyManagementDelegate::GetForecast() to get the current forecast |
| // Modify the slot structure - the slots memory is owned by EVSEManufacturerImpl |
| // Call DeviceEnergyManagementDelegate::GetForecast() to set the current forecast |
| // |
| // |
| // The cluster object DeviceEnergyManagement::Instance |
| // (src/app/clusters/device-energy-management-server/device-energy-management-server.cpp) only reads the slots field of |
| // forecast when checking commands (indeed it does not modify any forecast fields itself). The DeviceEnergyManagementDelegate |
| // object does modify some of forecast's fields but does NOT modify the slots field. The only command that can modify the |
| // slots field is HandleModifyForecastRequest. Whilst DeviceEnergyManagementDelegate::ModifyForecastRequest does some state |
| // checking, the slots field is only modified by the EVSEManufacturerImpl object via the call |
| // DEMManufacturerDelegate::HandleModifyForecastRequest. DEMManufacturerDelegate::HandleModifyForecastRequest may |
| // delete/allocate the slots memory but this will be done atomically in the call to |
| // DEMManufacturerDelegate::HandleModifyForecastRequest so the underlying memory is coherent => the call to |
| // DEMManufacturerDelegate::HandleModifyForecastRequest cannot be interrupted by any other CHIP task activity. |
| CHIP_ERROR SetForecast(const DataModel::Nullable<Structs::ForecastStruct::Type> &); |
| |
| CHIP_ERROR SetOptOutState(OptOutStateEnum); |
| |
| // Returns whether the DeviceEnergyManagement is supported |
| uint32_t HasFeature(Feature feature) const; |
| |
| private: |
| /** |
| * @brief Handle a PowerAdjustRequest failing |
| * |
| * Cleans up the PowerAdjust state should the request fail |
| */ |
| void HandlePowerAdjustRequestFailure(); |
| |
| // Methods to handle when a PowerAdjustment completes |
| static void PowerAdjustTimerExpiry(System::Layer * systemLayer, void * delegate); |
| void HandlePowerAdjustTimerExpiry(); |
| |
| // Method to cancel a PowerAdjustment |
| CHIP_ERROR CancelPowerAdjustRequestAndGenerateEvent(CauseEnum cause); |
| |
| // Method to generate a PowerAdjustEnd event |
| CHIP_ERROR GeneratePowerAdjustEndEvent(CauseEnum cause); |
| |
| /** |
| * @brief Handle a PauseRequest failing |
| * |
| * Cleans up the state should the PauseRequest fail |
| */ |
| void HandlePauseRequestFailure(); |
| |
| // Methods to handle when a PauseRequest completes |
| static void PauseRequestTimerExpiry(System::Layer * systemLayer, void * delegate); |
| void HandlePauseRequestTimerExpiry(); |
| |
| // Method to cancel a PauseRequest |
| CHIP_ERROR CancelPauseRequestAndGenerateEvent(CauseEnum cause); |
| |
| // Method to generate a Paused event |
| CHIP_ERROR GenerateResumedEvent(CauseEnum cause); |
| |
| private: |
| // Have a pointer to partner instance object |
| DeviceEnergyManagement::Instance * mpDEMInstance; |
| |
| // The DEMManufacturerDelegate object knows how to handle |
| // manufacturer/product specific operations |
| DEMManufacturerDelegate * mpDEMManufacturerDelegate; |
| |
| // Various attributes |
| ESATypeEnum mEsaType; |
| bool mEsaCanGenerate; |
| ESAStateEnum mEsaState; |
| int64_t mAbsMinPowerMw; |
| int64_t mAbsMaxPowerMw; |
| OptOutStateEnum mOptOutState; |
| |
| DataModel::Nullable<Structs::PowerAdjustCapabilityStruct::Type> mPowerAdjustCapabilityStruct; |
| |
| // See note above on SetForecast() about mForecast memory management |
| DataModel::Nullable<Structs::ForecastStruct::Type> mForecast; |
| |
| // Keep track whether a PowerAdjustment is in progress |
| bool mPowerAdjustmentInProgress; |
| |
| // Keep track of when that PowerAdjustment started |
| uint32_t mPowerAdjustmentStartTimeUtc; |
| |
| // Keep track whether a PauseRequest is in progress |
| bool mPauseRequestInProgress; |
| }; |
| |
| } // namespace DeviceEnergyManagement |
| } // namespace Clusters |
| } // namespace app |
| } // namespace chip |