name: 130.2.1. [TC-BRBINFO-2.1] Attributes [DUT-Server]
config:
nodeId: 0x12344321
cluster: "Bridged Device Basic"
endpoint: 3
tests:
- label: "Wait for the commissioned device to be retrieved"
cluster: "DelayCommands"
command: "WaitForCommissionee"
arguments:
values:
- name: "nodeId"
value: nodeId
- label: "TH reads VendorName from the DUT."
PICS: BRBINFO.S.A0001
command: "readAttribute"
attribute: "VendorName"
response:
saveAs: VendorNameValue
constraints:
type: char_string
maxLength: 32
- label: "TH writes VendorName from the DUT."
PICS: BRBINFO.S.A0001
command: "writeAttribute"
attribute: "VendorName"
arguments:
value: "sample"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads VendorName from the DUT."
PICS: BRBINFO.S.A0001
command: "readAttribute"
attribute: "VendorName"
response:
value: VendorNameValue
- label: "TH reads VendorID from the DUT."
PICS: BRBINFO.S.A0002
command: "readAttribute"
attribute: "VendorID"
response:
saveAs: VendorIDValue
constraints:
type: vendor_id
minValue: 1
maxValue: 65521
- label:
"Verify that VendorID matches the value assigned to this manufacturer"
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT && BRBINFO.S.A0002
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "TH writes VendorID from the DUT."
PICS: BRBINFO.S.A0002
command: "writeAttribute"
attribute: "VendorID"
arguments:
value: 0x0011
response:
error: UNSUPPORTED_WRITE
- label: "TH reads VendorID from the DUT."
PICS: BRBINFO.S.A0002
command: "readAttribute"
attribute: "VendorID"
response:
value: VendorIDValue
- label: "TH reads ProductName from the DUT"
PICS: BRBINFO.S.A0003
command: "readAttribute"
attribute: "ProductName"
response:
saveAs: ProductNameValue
constraints:
type: char_string
maxLength: 32
- label: "TH writes ProductName from the DUT."
PICS: BRBINFO.S.A0003
command: "writeAttribute"
attribute: "ProductName"
arguments:
value: "newproduct"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads ProductName from the DUT"
PICS: BRBINFO.S.A0003
command: "readAttribute"
attribute: "ProductName"
response:
value: ProductNameValue
- label: "TH reads NodeLabel from the DUT"
PICS: BRBINFO.S.A0005
command: "readAttribute"
attribute: "NodeLabel"
response:
saveAs: NodeLabelValue
constraints:
type: char_string
maxLength: 32
#Issue https://github.com/project-chip/connectedhomeip/issues/23509
- label: "TH writes NodeLabel from the DUT."
PICS: BRBINFO.S.A0005 && PICS_USER_PROMPT
verification: |
./chip-tool bridgeddevicebasic write node-label '"newnode"' 1 3
Verify response has unsupported write on TH(chip-tool) Log:
NOTE the quotes: single-quote/double-quote/string/double-quote/single-quote
[1660839701.840432][2444:2449] CHIP:DMG: }
[1660839701.840505][2444:2449] CHIP:DMG:
[1660839701.840578][2444:2449] CHIP:DMG: StatusIB =
[1660839701.840661][2444:2449] CHIP:DMG: {
[1660839701.840742][2444:2449] CHIP:DMG: status = 0x88 (UNSUPPORTED_WRITE),
[1660839701.840827][2444:2449] CHIP:DMG: },
[1660839701.840905][2444:2449] CHIP:DMG:
[1660839701.840973][2444:2449] CHIP:DMG: },
cluster: "LogCommands"
command: "UserPrompt"
arguments:
values:
- name: "message"
value: "Please enter 'y' after success"
- name: "expectedValue"
value: "y"
- label: "TH reads NodeLabel from the DUT"
PICS: BRBINFO.S.A0005 && PICS_USER_PROMPT
verification: |
./chip-tool bridgeddevicebasic read node-label 1 3
Verify the value of node-label is type of string and contains length between 0 and 32 in TH(chip-tool) Log:
[1657696463.081741][15476:15481] CHIP:TOO: Endpoint: 3 Cluster: 0x0000_0039 Attribute 0x0000_0005 DataVersion: 2577979325
[1657696463.081791][15476:15481] CHIP:TOO: NodeLabel: newnode
cluster: "LogCommands"
command: "UserPrompt"
arguments:
values:
- name: "message"
value: "Please enter 'y' after success"
- name: "expectedValue"
value: "y"
- label: "TH reads HardwareVersion from the DUT"
PICS: BRBINFO.S.A0007
command: "readAttribute"
attribute: "HardwareVersion"
response:
saveAs: HardwareVersionValue
constraints:
type: int16u
minValue: 0
maxValue: 65534
- label: "TH writes HardwareVersion from the DUT."
PICS: BRBINFO.S.A0007
command: "writeAttribute"
attribute: "HardwareVersion"
arguments:
value: 0x4531
response:
error: UNSUPPORTED_WRITE
- label: "TH reads HardwareVersion from the DUT"
PICS: BRBINFO.S.A0007
command: "readAttribute"
attribute: "HardwareVersion"
response:
value: HardwareVersionValue
- label: "TH reads HardwareVersionString from the DUT."
PICS: BRBINFO.S.A0008
command: "readAttribute"
attribute: "HardwareVersionString"
response:
saveAs: HardwareVersionStringValue
constraints:
type: char_string
minLength: 1
maxLength: 64
- label: "TH writes HardwareVersionString from the DUT."
PICS: BRBINFO.S.A0008
command: "writeAttribute"
attribute: "HardwareVersionString"
arguments:
value: "newhardwareversion"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads HardwareVersionString from the DUT."
PICS: BRBINFO.S.A0008
command: "readAttribute"
attribute: "HardwareVersionString"
response:
value: HardwareVersionStringValue
- label: "TH reads SoftwareVersion from the DUT"
PICS: BRBINFO.S.A0009
command: "readAttribute"
attribute: "SoftwareVersion"
response:
saveAs: SoftwareVersionValue
constraints:
minValue: 0
maxValue: 4294967294
- label: "TH writes SoftwareVersion from the DUT."
PICS: BRBINFO.S.A0009
command: "writeAttribute"
attribute: "SoftwareVersion"
arguments:
value: 0x8213
response:
error: UNSUPPORTED_WRITE
- label: "TH reads SoftwareVersion from the DUT"
PICS: BRBINFO.S.A0009
command: "readAttribute"
attribute: "SoftwareVersion"
response:
value: SoftwareVersionValue
- label: "TH reads SoftwareVersionString from the DUT"
PICS: BRBINFO.S.A000a
command: "readAttribute"
attribute: "SoftwareVersionString"
response:
saveAs: SoftwareVersionStringValue
constraints:
minLength: 1
maxLength: 64
- label: "TH writes SoftwareVersionString from the DUT."
PICS: BRBINFO.S.A000a
command: "writeAttribute"
attribute: "SoftwareVersionString"
arguments:
value: "1.0"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads SoftwareVersionString from the DUT"
PICS: BRBINFO.S.A000a
command: "readAttribute"
attribute: "SoftwareVersionString"
response:
value: SoftwareVersionStringValue
- label: "TH reads ManufacturingDate from the DUT."
PICS: BRBINFO.S.A000b
command: "readAttribute"
attribute: "ManufacturingDate"
response:
saveAs: ManufacturingDateValue
constraints:
type: char_string
minLength: 8
maxLength: 16
- label:
"Verify if the first 8 characters specify date according to ISO 8601,
i.e, YYYYMMDD."
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT && BRBINFO.S.A000b
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "TH writes ManufacturingDate from the DUT."
PICS: BRBINFO.S.A000b
command: "writeAttribute"
attribute: "ManufacturingDate"
arguments:
value: "20210814789452IN"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads ManufacturingDate from the DUT."
PICS: BRBINFO.S.A000b
command: "readAttribute"
attribute: "ManufacturingDate"
response:
value: ManufacturingDateValue
- label: "TH reads PartNumber from the DUT"
PICS: BRBINFO.S.A000c
command: "readAttribute"
attribute: "PartNumber"
response:
saveAs: PartNumberValue
constraints:
type: char_string
maxLength: 32
- label: "TH writes PartNumber from the DUT."
PICS: BRBINFO.S.A000c
command: "writeAttribute"
attribute: "PartNumber"
arguments:
value: "newpart"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads PartNumber from the DUT"
PICS: BRBINFO.S.A000c
command: "readAttribute"
attribute: "PartNumber"
response:
value: PartNumberValue
- label: "TH reads ProductURL from the DUT"
PICS: BRBINFO.S.A000d
command: "readAttribute"
attribute: "ProductURL"
response:
saveAs: ProductURLValue
constraints:
type: long_char_string
maxLength: 256
- label:
"Verify that it specifies a link to a specific web page, Verify that
it follows the syntax rules specified in RFC 3986."
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT && BRBINFO.S.A000d
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "TH writes ProductURL from the DUT."
PICS: BRBINFO.S.A000d
command: "writeAttribute"
attribute: "ProductURL"
arguments:
value: "https://www.example.com"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads ProductURL from the DUT"
PICS: BRBINFO.S.A000d
command: "readAttribute"
attribute: "ProductURL"
response:
value: ProductURLValue
- label: "TH reads ProductLabel from the DUT."
PICS: BRBINFO.S.A000e
command: "readAttribute"
attribute: "ProductLabel"
response:
saveAs: ProductLabelValue
constraints:
type: char_string
maxLength: 64
- label:
"Verify that it does not include the name of the vendor as defined
within the VendorName attribute"
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT && BRBINFO.S.A000e
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "TH writes ProductLabel from the DUT."
PICS: BRBINFO.S.A000e
command: "writeAttribute"
attribute: "ProductLabel"
arguments:
value: "newproductlabel"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads ProductLabel from the DUT."
PICS: BRBINFO.S.A000e
command: "readAttribute"
attribute: "ProductLabel"
response:
value: ProductLabelValue
- label: "TH reads SerialNumber from the DUT."
PICS: BRBINFO.S.A000f
command: "readAttribute"
attribute: "SerialNumber"
response:
saveAs: SerialNumberValue
constraints:
type: char_string
maxLength: 32
- label: "TH writes SerialNumber from the DUT."
PICS: BRBINFO.S.A000f
command: "writeAttribute"
attribute: "SerialNumber"
arguments:
value: "newserialnumber"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads SerialNumber from the DUT."
PICS: BRBINFO.S.A000f
command: "readAttribute"
attribute: "SerialNumber"
response:
value: SerialNumberValue
- label: "TH reads Reachable from the DUT."
PICS: BRBINFO.S.A0011
command: "readAttribute"
attribute: "Reachable"
response:
value: true
constraints:
type: boolean
- label:
"TH sends Write request message to DUT to change value of Reachable to
false"
PICS: BRBINFO.S.A0011
command: "writeAttribute"
attribute: "Reachable"
arguments:
value: false
response:
error: UNSUPPORTED_WRITE
- label: "TH reads Reachable from the DUT."
PICS: BRBINFO.S.A0011
command: "readAttribute"
attribute: "Reachable"
response:
value: true
constraints:
type: boolean
- label: "TH reads UniqueID from the DUT."
PICS: BRBINFO.S.A0012
command: "readAttribute"
attribute: "UniqueID"
response:
saveAs: UniqueIDValue
constraints:
type: char_string
maxLength: 32
- label: "TH writes UniqueID from the DUT."
PICS: BRBINFO.S.A0012
command: "writeAttribute"
attribute: "UniqueID"
arguments:
value: "newid"
response:
error: UNSUPPORTED_WRITE
- label: "TH reads UniqueID from the DUT."
PICS: BRBINFO.S.A0012
command: "readAttribute"
attribute: "UniqueID"
response:
value: UniqueIDValue