| * Copyright (c) 2023 Project CHIP Authors |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| * |
| */ |
| |
| #include <app-common/zap-generated/attributes/Accessors.h> |
| #include <app/InteractionModelEngine.h> |
| #include <app/clusters/microwave-oven-control-server/microwave-oven-control-server.h> |
| #include <app/clusters/mode-base-server/mode-base-server.h> |
| #include <app/reporting/reporting.h> |
| #include <app/util/attribute-storage.h> |
| #include <app/util/ember-compatibility-functions.h> |
| |
| using namespace chip; |
| using namespace chip::app; |
| using namespace chip::app::Clusters; |
| using namespace chip::app::Clusters::OperationalState; |
| using namespace chip::app::Clusters::MicrowaveOvenControl; |
| using namespace chip::app::Clusters::ModeBase; |
| using namespace chip::app::Clusters::MicrowaveOvenMode; |
| using namespace chip::app::Clusters::MicrowaveOvenControl::Attributes; |
| using Status = Protocols::InteractionModel::Status; |
| |
| namespace chip { |
| namespace app { |
| namespace Clusters { |
| namespace MicrowaveOvenControl { |
| |
| Instance::Instance(Delegate * aDelegate, EndpointId aEndpointId, ClusterId aClusterId, |
| BitMask<MicrowaveOvenControl::Feature> aFeature, Clusters::OperationalState::Instance & aOpStateInstance, |
| Clusters::ModeBase::Instance & aMicrowaveOvenModeInstance) : |
| CommandHandlerInterface(MakeOptional(aEndpointId), aClusterId), |
| AttributeAccessInterface(MakeOptional(aEndpointId), aClusterId), mDelegate(aDelegate), mEndpointId(aEndpointId), |
| mClusterId(aClusterId), mFeature(aFeature), mOpStateInstance(aOpStateInstance), |
| mMicrowaveOvenModeInstance(aMicrowaveOvenModeInstance) |
| { |
| mDelegate->SetInstance(this); |
| } |
| |
| Instance::~Instance() |
| { |
| InteractionModelEngine::GetInstance()->UnregisterCommandHandler(this); |
| unregisterAttributeAccessOverride(this); |
| } |
| |
| CHIP_ERROR Instance::Init() |
| { |
| // Check if the cluster has been selected in zap |
| VerifyOrReturnError( |
| emberAfContainsServer(mEndpointId, mClusterId), CHIP_ERROR_INVALID_ARGUMENT, |
| ChipLogError(Zcl, "Microwave Oven Control: The cluster with ID %lu was not enabled in zap.", long(mClusterId))); |
| |
| // Exactly one of the PowerAsNumber and PowerInWatts features must be supported, per spec. |
| VerifyOrReturnError( |
| mFeature.Has(MicrowaveOvenControl::Feature::kPowerAsNumber) || mFeature.Has(MicrowaveOvenControl::Feature::kPowerInWatts), |
| CHIP_ERROR_INVALID_ARGUMENT, |
| ChipLogError(Zcl, |
| "Microwave Oven Control: feature bits error, feature must support one of PowerInWatts and PowerAsNumber")); |
| |
| // Check that the feature bits do not include both PowerAsNumber and PowerInWatts |
| VerifyOrReturnError( |
| !(mFeature.Has(MicrowaveOvenControl::Feature::kPowerAsNumber) && |
| mFeature.Has(MicrowaveOvenControl::Feature::kPowerInWatts)), |
| CHIP_ERROR_INVALID_ARGUMENT, |
| ChipLogError(Zcl, |
| "Microwave Oven Control: feature bits error, feature could not support both PowerAsNumber and PowerInWatts")); |
| |
| // Per spec, the PowerNumberLimits feature is only allowed if the PowerAsNumber feature is supported. |
| VerifyOrReturnError( |
| !mFeature.Has(MicrowaveOvenControl::Feature::kPowerNumberLimits) || |
| mFeature.Has(MicrowaveOvenControl::Feature::kPowerAsNumber), |
| CHIP_ERROR_INVALID_ARGUMENT, |
| ChipLogError( |
| Zcl, |
| "Microwave Oven Control: feature bits error, if feature supports PowerNumberLimits it must support PowerAsNumber")); |
| |
| ReturnErrorOnFailure(InteractionModelEngine::GetInstance()->RegisterCommandHandler(this)); |
| VerifyOrReturnError(registerAttributeAccessOverride(this), CHIP_ERROR_INCORRECT_STATE); |
| // If the PowerInWatts feature is supported, get the count of supported watt levels so we can later |
| // ensure incoming watt level values are valid. |
| if (HasFeature(MicrowaveOvenControl::Feature::kPowerInWatts)) |
| { |
| mSupportedWattLevels = GetCountOfSupportedWattLevels(); |
| VerifyOrReturnError(mSupportedWattLevels > 0, CHIP_ERROR_INVALID_ARGUMENT, |
| ChipLogError(Zcl, "Microwave Oven Control: supported watt levels is empty")); |
| } |
| return CHIP_NO_ERROR; |
| } |
| |
| bool Instance::HasFeature(MicrowaveOvenControl::Feature feature) const |
| { |
| return mFeature.Has(feature); |
| } |
| |
| uint8_t Instance::GetCountOfSupportedWattLevels() const |
| { |
| uint8_t wattIndex = 0; |
| uint16_t watt = 0; |
| while (mDelegate->GetWattSettingByIndex(wattIndex, watt) == CHIP_NO_ERROR) |
| { |
| wattIndex++; |
| } |
| return wattIndex; |
| } |
| |
| uint32_t Instance::GetCookTimeSec() const |
| { |
| return mCookTimeSec; |
| } |
| |
| void Instance::SetCookTimeSec(uint32_t cookTimeSec) |
| { |
| uint32_t oldCookTimeSec = mCookTimeSec; |
| mCookTimeSec = cookTimeSec; |
| if (mCookTimeSec != oldCookTimeSec) |
| { |
| MatterReportingAttributeChangeCallback(mEndpointId, mClusterId, Attributes::CookTime::Id); |
| } |
| } |
| |
| CHIP_ERROR Instance::Read(const ConcreteReadAttributePath & aPath, AttributeValueEncoder & aEncoder) |
| { |
| ChipLogError(Zcl, "Microwave Oven Control: Reading"); |
| switch (aPath.mAttributeId) |
| { |
| case MicrowaveOvenControl::Attributes::CookTime::Id: |
| return aEncoder.Encode(GetCookTimeSec()); |
| |
| case MicrowaveOvenControl::Attributes::MaxCookTime::Id: |
| return aEncoder.Encode(mDelegate->GetMaxCookTimeSec()); |
| |
| case MicrowaveOvenControl::Attributes::PowerSetting::Id: |
| VerifyOrReturnError(HasFeature(MicrowaveOvenControl::Feature::kPowerAsNumber), CHIP_ERROR_UNSUPPORTED_CHIP_FEATURE, |
| ChipLogError(Zcl, "Microwave Oven Control: can not get PowerSetting number, feature is not supported")); |
| |
| return aEncoder.Encode(mDelegate->GetPowerSettingNum()); |
| |
| case MicrowaveOvenControl::Attributes::MinPower::Id: |
| VerifyOrReturnError(HasFeature(MicrowaveOvenControl::Feature::kPowerAsNumber), CHIP_ERROR_UNSUPPORTED_CHIP_FEATURE, |
| ChipLogError(Zcl, "Microwave Oven Control: can not get MinPower number, feature is not supported")); |
| |
| return aEncoder.Encode(HasFeature(MicrowaveOvenControl::Feature::kPowerNumberLimits) ? mDelegate->GetMinPowerNum() |
| : kDefaultMinPowerNum); |
| |
| case MicrowaveOvenControl::Attributes::MaxPower::Id: |
| VerifyOrReturnError(HasFeature(MicrowaveOvenControl::Feature::kPowerAsNumber), CHIP_ERROR_UNSUPPORTED_CHIP_FEATURE, |
| ChipLogError(Zcl, "Microwave Oven Control: can not get MaxPower number, feature is not supported")); |
| |
| return aEncoder.Encode(HasFeature(MicrowaveOvenControl::Feature::kPowerNumberLimits) ? mDelegate->GetMaxPowerNum() |
| : kDefaultMaxPowerNum); |
| |
| case MicrowaveOvenControl::Attributes::PowerStep::Id: |
| VerifyOrReturnError(HasFeature(MicrowaveOvenControl::Feature::kPowerAsNumber), CHIP_ERROR_UNSUPPORTED_CHIP_FEATURE, |
| ChipLogError(Zcl, "Microwave Oven Control: can not get PowerStep number, feature is not supported")); |
| |
| return aEncoder.Encode(HasFeature(MicrowaveOvenControl::Feature::kPowerNumberLimits) ? mDelegate->GetPowerStepNum() |
| : kDefaultPowerStepNum); |
| |
| case MicrowaveOvenControl::Attributes::SupportedWatts::Id: |
| VerifyOrReturnError(HasFeature(MicrowaveOvenControl::Feature::kPowerInWatts), CHIP_ERROR_UNSUPPORTED_CHIP_FEATURE, |
| ChipLogError(Zcl, "Microwave Oven Control: can not get SuppoertWatts list, feature is not supported")); |
| |
| return aEncoder.EncodeList([delegate = mDelegate](const auto & encoder) -> CHIP_ERROR { |
| uint16_t wattRating; |
| uint8_t index = 0; |
| CHIP_ERROR err = CHIP_NO_ERROR; |
| while ((err = delegate->GetWattSettingByIndex(index, wattRating)) == CHIP_NO_ERROR) |
| { |
| ReturnErrorOnFailure(encoder.Encode(wattRating)); |
| index++; |
| } |
| if (err == CHIP_ERROR_NOT_FOUND) |
| { |
| return CHIP_NO_ERROR; |
| } |
| return err; |
| }); |
| |
| case MicrowaveOvenControl::Attributes::SelectedWattIndex::Id: |
| VerifyOrReturnError( |
| HasFeature(MicrowaveOvenControl::Feature::kPowerInWatts), CHIP_ERROR_UNSUPPORTED_CHIP_FEATURE, |
| ChipLogError(Zcl, "Microwave Oven Control: can not get SelectedWattIndex number, feature is not supported")); |
| |
| return aEncoder.Encode(mDelegate->GetCurrentWattIndex()); |
| |
| case MicrowaveOvenControl::Attributes::WattRating::Id: |
| return aEncoder.Encode(mDelegate->GetWattRating()); |
| |
| case MicrowaveOvenControl::Attributes::FeatureMap::Id: |
| return aEncoder.Encode(mFeature.Raw()); |
| } |
| return CHIP_NO_ERROR; |
| } |
| |
| void Instance::InvokeCommand(HandlerContext & handlerContext) |
| { |
| ChipLogDetail(Zcl, "Microwave Oven Control: InvokeCommand"); |
| switch (handlerContext.mRequestPath.mCommandId) |
| { |
| case Commands::SetCookingParameters::Id: |
| ChipLogDetail(Zcl, "Microwave Oven Control: Entering SetCookingParameters"); |
| |
| CommandHandlerInterface::HandleCommand<Commands::SetCookingParameters::DecodableType>( |
| handlerContext, [this](HandlerContext & ctx, const auto & req) { HandleSetCookingParameters(ctx, req); }); |
| break; |
| |
| case Commands::AddMoreTime::Id: |
| ChipLogDetail(Zcl, "Microwave Oven Control: Entering AddMoreTime"); |
| |
| CommandHandlerInterface::HandleCommand<Commands::AddMoreTime::DecodableType>( |
| handlerContext, [this](HandlerContext & ctx, const auto & req) { HandleAddMoreTime(ctx, req); }); |
| break; |
| } |
| } |
| |
| void Instance::HandleSetCookingParameters(HandlerContext & ctx, const Commands::SetCookingParameters::DecodableType & req) |
| { |
| ChipLogDetail(Zcl, "Microwave Oven Control: HandleSetCookingParameters"); |
| Status status = Status::Success; |
| uint8_t opState; |
| uint8_t modeValue; |
| uint8_t reqCookMode; |
| uint32_t reqCookTimeSec; |
| bool reqStartAfterSetting; |
| auto & cookMode = req.cookMode; |
| auto & cookTimeSec = req.cookTime; |
| auto & powerSetting = req.powerSetting; |
| auto & wattSettingIndex = req.wattSettingIndex; |
| auto & startAfterSetting = req.startAfterSetting; |
| |
| opState = mOpStateInstance.GetCurrentOperationalState(); |
| VerifyOrExit(opState == to_underlying(OperationalStateEnum::kStopped), status = Status::InvalidInState); |
| |
| if (startAfterSetting.HasValue()) |
| { |
| VerifyOrExit( |
| ServerClusterCommandExists( |
| ConcreteCommandPath(mEndpointId, OperationalState::Id, OperationalState::Commands::Start::Id)) == Status::Success, |
| status = Status::InvalidCommand; |
| ChipLogError( |
| Zcl, |
| "Microwave Oven Control: Failed to set cooking parameters, Start command of operational state is not supported")); |
| } |
| reqStartAfterSetting = startAfterSetting.ValueOr(false); |
| |
| modeValue = 0; |
| VerifyOrExit(mMicrowaveOvenModeInstance.GetModeValueByModeTag(to_underlying(MicrowaveOvenMode::ModeTag::kNormal), modeValue) == |
| CHIP_NO_ERROR, |
| status = Status::InvalidCommand; |
| ChipLogError(Zcl, "Microwave Oven Control: Failed to set cookMode, Normal mode is not found")); |
| |
| reqCookMode = cookMode.ValueOr(modeValue); |
| VerifyOrExit(mMicrowaveOvenModeInstance.IsSupportedMode(reqCookMode), status = Status::ConstraintError; |
| ChipLogError(Zcl, "Microwave Oven Control: Failed to set cookMode, cookMode is not supported")); |
| |
| reqCookTimeSec = cookTimeSec.ValueOr(MicrowaveOvenControl::kDefaultCookTimeSec); |
| VerifyOrExit(IsCookTimeSecondsInRange(reqCookTimeSec, mDelegate->GetMaxCookTimeSec()), status = Status::ConstraintError; |
| ChipLogError(Zcl, "Microwave Oven Control: Failed to set cookTime, cookTime value is out of range")); |
| |
| if (HasFeature(MicrowaveOvenControl::Feature::kPowerAsNumber)) |
| { |
| // if using power as number, check if the param is invalid and set PowerSetting number. |
| uint8_t reqPowerSettingNum; |
| uint8_t maxPowerNum = kDefaultMaxPowerNum; |
| uint8_t minPowerNum = kDefaultMinPowerNum; |
| uint8_t powerStepNum = kDefaultPowerStepNum; |
| VerifyOrExit(!wattSettingIndex.HasValue(), status = Status::InvalidCommand; ChipLogError( |
| Zcl, "Microwave Oven Control: Failed to set cooking parameters, should have no value for wattSettingIndex")); |
| |
| VerifyOrExit( |
| cookMode.HasValue() || cookTimeSec.HasValue() || powerSetting.HasValue(), status = Status::InvalidCommand; |
| ChipLogError(Zcl, "Microwave Oven Control: Failed to set cooking parameters, all command fields are missing ")); |
| |
| if (HasFeature(MicrowaveOvenControl::Feature::kPowerNumberLimits)) |
| { |
| maxPowerNum = mDelegate->GetMaxPowerNum(); |
| minPowerNum = mDelegate->GetMinPowerNum(); |
| powerStepNum = mDelegate->GetPowerStepNum(); |
| } |
| reqPowerSettingNum = powerSetting.ValueOr(maxPowerNum); |
| VerifyOrExit(IsPowerSettingNumberInRange(reqPowerSettingNum, minPowerNum, maxPowerNum), status = Status::ConstraintError; |
| ChipLogError(Zcl, "Microwave Oven Control: Failed to set PowerSetting, PowerSetting value is out of range")); |
| |
| VerifyOrExit( |
| reqPowerSettingNum % powerStepNum == 0, status = Status::InvalidCommand; ChipLogError( |
| Zcl, |
| "Microwave Oven Control: Failed to set PowerSetting, PowerSetting value must be multiple of PowerStep number")); |
| |
| status = mDelegate->HandleSetCookingParametersCallback(reqCookMode, reqCookTimeSec, reqStartAfterSetting, |
| MakeOptional(reqPowerSettingNum), NullOptional); |
| } |
| else |
| { |
| // if using power in watt, check if the param is invalid and set wattSettingIndex number. |
| uint8_t reqWattSettingIndex; |
| VerifyOrExit(!powerSetting.HasValue(), status = Status::InvalidCommand; ChipLogError( |
| Zcl, "Microwave Oven Control: Failed to set cooking parameters, should have no value for powerSetting ")); |
| |
| VerifyOrExit( |
| cookMode.HasValue() || cookTimeSec.HasValue() || wattSettingIndex.HasValue(), status = Status::InvalidCommand; |
| ChipLogError(Zcl, "Microwave Oven Control: Failed to set cooking parameters, all command fields are missing ")); |
| |
| // count of supported watt levels must greater than 0 |
| VerifyOrExit( |
| mSupportedWattLevels > 0, |
| ChipLogError(Zcl, "Microwave Oven Control: Failed to set wattSettingIndex, count of supported watt levels is 0")); |
| uint8_t maxWattSettingIndex = static_cast<uint8_t>(mSupportedWattLevels - 1); |
| reqWattSettingIndex = wattSettingIndex.ValueOr(maxWattSettingIndex); |
| VerifyOrExit(reqWattSettingIndex <= maxWattSettingIndex, status = Status::ConstraintError; |
| ChipLogError(Zcl, "Microwave Oven Control: Failed to set wattSettingIndex, wattSettingIndex is out of range")); |
| |
| status = mDelegate->HandleSetCookingParametersCallback(reqCookMode, reqCookTimeSec, reqStartAfterSetting, NullOptional, |
| MakeOptional(reqWattSettingIndex)); |
| } |
| |
| exit: |
| ctx.mCommandHandler.AddStatus(ctx.mRequestPath, status); |
| } |
| |
| void Instance::HandleAddMoreTime(HandlerContext & ctx, const Commands::AddMoreTime::DecodableType & req) |
| { |
| ChipLogDetail(Zcl, "Microwave Oven Control: HandleAddMoreTime"); |
| Status status; |
| uint8_t opState; |
| uint32_t finalCookTimeSec; |
| |
| opState = mOpStateInstance.GetCurrentOperationalState(); |
| VerifyOrExit(opState != to_underlying(OperationalStateEnum::kError), status = Status::InvalidInState); |
| |
| // if the added cooking time is greater than the max cooking time, the cooking time stay unchanged. |
| VerifyOrExit(req.timeToAdd + GetCookTimeSec() <= mDelegate->GetMaxCookTimeSec(), status = Status::ConstraintError; |
| ChipLogError(Zcl, "Microwave Oven Control: Failed to set cookTime, cookTime value is out of range")); |
| |
| finalCookTimeSec = GetCookTimeSec() + req.timeToAdd; |
| status = mDelegate->HandleModifyCookTimeSecondsCallback(finalCookTimeSec); |
| |
| exit: |
| ctx.mCommandHandler.AddStatus(ctx.mRequestPath, status); |
| } |
| |
| bool IsCookTimeSecondsInRange(uint32_t cookTimeSec, uint32_t maxCookTimeSec) |
| { |
| return MicrowaveOvenControl::kMinCookTimeSec <= cookTimeSec && cookTimeSec <= maxCookTimeSec; |
| } |
| |
| bool IsPowerSettingNumberInRange(uint8_t powerSettingNum, uint8_t minCookPowerNum, uint8_t maxCookPowerNum) |
| { |
| return minCookPowerNum <= powerSettingNum && powerSettingNum <= maxCookPowerNum; |
| } |
| |
| } // namespace MicrowaveOvenControl |
| } // namespace Clusters |
| } // namespace app |
| } // namespace chip |
| |
| /** @brief Microwave Oven Control Cluster Server Init |
| * |
| * Server Init |
| * |
| */ |
| void MatterMicrowaveOvenControlPluginServerInitCallback() {} |