blob: 6c5584e087d47c20b59fe78f8f46b63dc9574883 [file] [log] [blame]
<?xml version="1.0"?>
<!--
Copyright (C) Connectivity Standards Alliance (2021-2024). All rights reserved.
The information within this document is the property of the Connectivity
Standards Alliance and its use and disclosure are restricted, except as
expressly set forth herein.
Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive,
nontransferable, worldwide, limited and revocable license (without the right to
sublicense), under Connectivity Standards Alliance's applicable copyright
rights, to view, download, save, reproduce and use the document solely for your
own internal purposes and in accordance with the terms of the license set forth
herein. This license does not authorize you to, and you expressly warrant that
you shall not: (a) permit others (outside your organization) to use this
document; (b) post or publish this document; (c) modify, adapt, translate, or
otherwise change this document in any manner or create any derivative work
based on this document; (d) remove or modify any notice or label on this
document, including this Copyright Notice, License and Disclaimer. The
Connectivity Standards Alliance does not grant you any license hereunder other
than as expressly stated herein.
Elements of this document may be subject to third party intellectual property
rights, including without limitation, patent, copyright or trademark rights,
and any such third party may or may not be a member of the Connectivity
Standards Alliance. Connectivity Standards Alliance members grant other
Connectivity Standards Alliance members certain intellectual property rights as
set forth in the Connectivity Standards Alliance IPR Policy. Connectivity
Standards Alliance members do not grant you any rights under this license. The
Connectivity Standards Alliance is not responsible for, and shall not be held
responsible in any manner for, identifying or failing to identify any or all
such third party intellectual property rights. Please visit www.csa-iot.org for
more information on how to become a member of the Connectivity Standards
Alliance.
This document and the information contained herein are provided on an “AS IS”
basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE
INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING
WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT
OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS
FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE
CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF
BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER
DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL
DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT
OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
LOSS OR DAMAGE.
All company, brand and product names in this document may be trademarks that
are the sole property of their respective owners.
This notice and disclaimer must be included on all copies of this document.
Connectivity Standards Alliance
508 Second Street, Suite 206
Davis, CA 95616, USA
-->
<cluster xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="types types.xsd cluster cluster.xsd" id="0x0201" name="Thermostat Cluster" revision="8">
<revisionHistory>
<revision revision="1" summary="Mandatory global ClusterRevision attribute added; fixed some defaults; CCB 1823, 1480"/>
<revision revision="2" summary="CCB 1981 2186 2249 2250 2251; NFR Thermostat Setback"/>
<revision revision="3" summary="CCB 2477 2560 2773 2777 2815 2816 3029"/>
<revision revision="4" summary="All Hubs changes"/>
<revision revision="5" summary="New data model format and notation, added FeatureMap, collapsed attribute sets, clarified edge cases around limits, default value of xxxSetpointLimit now respects AbsxxxSetpointLimit"/>
<revision revision="6" summary="Introduced the LTNE feature and adapted text (spec issue #5778)"/>
<revision revision="7" summary="Update constraints on local temperature calibration and minimum setpoint deadband and introduced
Presets and MatterScheduleConfiguration features"/>
<revision revision="8" summary="Added comment regarding writing to ControlSequenceOfOperation."/>
</revisionHistory>
<clusterIds>
<clusterId id="0x0201" name="Thermostat"/>
</clusterIds>
<classification hierarchy="base" role="application" picsCode="TSTAT" scope="Endpoint"/>
<features>
<feature bit="0" code="HEAT" name="Heating" summary="Thermostat is capable of managing a heating device">
<otherwiseConform>
<mandatoryConform>
<feature name="AUTO"/>
</mandatoryConform>
<optionalConform choice="a" more="true"/>
</otherwiseConform>
</feature>
<feature bit="1" code="COOL" name="Cooling" summary="Thermostat is capable of managing a cooling device">
<otherwiseConform>
<mandatoryConform>
<feature name="AUTO"/>
</mandatoryConform>
<optionalConform choice="a" more="true"/>
</otherwiseConform>
</feature>
<feature bit="2" code="OCC" name="Occupancy" summary="Supports Occupied and Unoccupied setpoints">
<optionalConform/>
</feature>
<feature bit="3" code="SCH" name="ScheduleConfiguration" summary="Supports remote configuration of a weekly schedule of setpoint transitions">
<otherwiseConform>
<optionalConform>
<condition name="Zigbee"/>
</optionalConform>
<deprecateConform/>
</otherwiseConform>
</feature>
<feature bit="4" code="SB" name="Setback" summary="Supports configurable setback (or span)">
<optionalConform/>
</feature>
<feature bit="5" code="AUTO" name="AutoMode" summary="Supports a System Mode of Auto">
<optionalConform/>
</feature>
<feature bit="6" code="LTNE" name="LocalTemperatureNotExposed" summary="Thermostat does not expose the LocalTemperature Value in the LocalTemperature attribute">
<optionalConform/>
</feature>
<feature bit="7" code="MSCH" name="MatterScheduleConfiguration" summary="Supports enhanced schedules">
<optionalConform/>
</feature>
<feature bit="8" code="PRES" name="Presets" summary="Thermostat supports setpoint presets">
<optionalConform/>
</feature>
</features>
<dataTypes>
<number name="SignedTemperature" type=""/>
<number name="TemperatureDifference" type=""/>
<number name="UnsignedTemperature" type=""/>
<enum name="ACCapacityFormatEnum">
<item value="0" name="BTUh" summary="British Thermal Unit per Hour">
<optionalConform/>
</item>
</enum>
<enum name="ACCompressorTypeEnum">
<item value="0" name="Unknown" summary="Unknown compressor type">
<optionalConform/>
</item>
<item value="1" name="T1" summary="Max working ambient 43 °C">
<optionalConform/>
</item>
<item value="2" name="T2" summary="Max working ambient 35 °C">
<optionalConform/>
</item>
<item value="3" name="T3" summary="Max working ambient 52 °C">
<optionalConform/>
</item>
</enum>
<enum name="ACLouverPositionEnum">
<item value="1" name="Closed" summary="Fully Closed">
<optionalConform/>
</item>
<item value="2" name="Open" summary="Fully Open">
<optionalConform/>
</item>
<item value="3" name="Quarter" summary="Quarter Open">
<optionalConform/>
</item>
<item value="4" name="Half" summary="Half Open">
<optionalConform/>
</item>
<item value="5" name="ThreeQuarters" summary="Three Quarters Open">
<optionalConform/>
</item>
</enum>
<enum name="ACRefrigerantTypeEnum">
<item value="0" name="Unknown" summary="Unknown Refrigerant Type">
<optionalConform/>
</item>
<item value="1" name="R22" summary="R22 Refrigerant">
<optionalConform/>
</item>
<item value="2" name="R410a" summary="R410a Refrigerant">
<optionalConform/>
</item>
<item value="3" name="R407c" summary="R407c Refrigerant">
<optionalConform/>
</item>
</enum>
<enum name="ACTypeEnum">
<item value="0" name="Unknown" summary="Unknown AC Type">
<optionalConform/>
</item>
<item value="1" name="CoolingFixed" summary="Cooling and Fixed Speed">
<optionalConform/>
</item>
<item value="2" name="HeatPumpFixed" summary="Heat Pump and Fixed Speed">
<optionalConform/>
</item>
<item value="3" name="CoolingInverter" summary="Cooling and Inverter">
<optionalConform/>
</item>
<item value="4" name="HeatPumpInverter" summary="Heat Pump and Inverter">
<optionalConform/>
</item>
</enum>
<enum name="ControlSequenceOfOperationEnum">
<item value="0" name="CoolingOnly" summary="Heat and Emergency are not possible">
<optionalConform>
<feature name="COOL"/>
</optionalConform>
</item>
<item value="1" name="CoolingWithReheat" summary="Heat and Emergency are not possible">
<optionalConform>
<feature name="COOL"/>
</optionalConform>
</item>
<item value="2" name="HeatingOnly" summary="Cool and precooling (see ref_HvacTerms) are not possible">
<optionalConform>
<feature name="HEAT"/>
</optionalConform>
</item>
<item value="3" name="HeatingWithReheat" summary="Cool and precooling are not possible">
<optionalConform>
<feature name="HEAT"/>
</optionalConform>
</item>
<item value="4" name="CoolingAndHeating" summary="All modes are possible">
<optionalConform>
<andTerm>
<feature name="HEAT"/>
<feature name="COOL"/>
</andTerm>
</optionalConform>
</item>
<item value="5" name="CoolingAndHeatingWithReheat" summary="All modes are possible">
<optionalConform>
<andTerm>
<feature name="HEAT"/>
<feature name="COOL"/>
</andTerm>
</optionalConform>
</item>
</enum>
<enum name="PresetScenarioEnum">
<item value="1" name="Occupied" summary="The thermostat-controlled area is occupied">
<mandatoryConform/>
</item>
<item value="2" name="Unoccupied" summary="The thermostat-controlled area is unoccupied">
<mandatoryConform/>
</item>
<item value="3" name="Sleep" summary="Users are likely to be sleeping">
<mandatoryConform/>
</item>
<item value="4" name="Wake" summary="Users are likely to be waking up">
<mandatoryConform/>
</item>
<item value="5" name="Vacation" summary="Users are on vacation">
<mandatoryConform/>
</item>
<item value="6" name="GoingToSleep" summary="Users are likely to be going to sleep">
<mandatoryConform/>
</item>
<item value="254" name="UserDefined" summary="Custom presets">
<mandatoryConform/>
</item>
</enum>
<enum name="SetpointChangeSourceEnum">
<item value="0" name="Manual" summary="Manual, user-initiated setpoint change via the thermostat">
<optionalConform/>
</item>
<item value="1" name="Schedule" summary="Schedule/internal programming-initiated setpoint change">
<optionalConform>
<orTerm>
<feature name="SCH"/>
<feature name="MSCH"/>
</orTerm>
</optionalConform>
</item>
<item value="2" name="External" summary="Externally-initiated setpoint change (e.g., DRLC cluster command, attribute write)">
<optionalConform/>
</item>
</enum>
<enum name="SetpointRaiseLowerModeEnum">
<item value="0" name="Heat" summary="Adjust Heat Setpoint">
<mandatoryConform>
<feature name="HEAT"/>
</mandatoryConform>
</item>
<item value="1" name="Cool" summary="Adjust Cool Setpoint">
<mandatoryConform>
<feature name="COOL"/>
</mandatoryConform>
</item>
<item value="2" name="Both" summary="Adjust Heat Setpoint and Cool Setpoint">
<mandatoryConform>
<orTerm>
<feature name="HEAT"/>
<feature name="COOL"/>
</orTerm>
</mandatoryConform>
</item>
</enum>
<enum name="StartOfWeekEnum">
<item value="0" name="Sunday">
<mandatoryConform/>
</item>
<item value="1" name="Monday">
<mandatoryConform/>
</item>
<item value="2" name="Tuesday">
<mandatoryConform/>
</item>
<item value="3" name="Wednesday">
<mandatoryConform/>
</item>
<item value="4" name="Thursday">
<mandatoryConform/>
</item>
<item value="5" name="Friday">
<mandatoryConform/>
</item>
<item value="6" name="Saturday">
<mandatoryConform/>
</item>
</enum>
<enum name="SystemModeEnum">
<item value="0" name="Off" summary="The Thermostat does not generate demand for Cooling or Heating">
<optionalConform/>
</item>
<item value="1" name="Auto" summary="Demand is generated for either Cooling or Heating, as required">
<mandatoryConform>
<feature name="AUTO"/>
</mandatoryConform>
</item>
<item value="3" name="Cool" summary="Demand is only generated for Cooling">
<optionalConform>
<feature name="COOL"/>
</optionalConform>
</item>
<item value="4" name="Heat" summary="Demand is only generated for Heating">
<optionalConform>
<feature name="HEAT"/>
</optionalConform>
</item>
<item value="5" name="EmergencyHeat" summary="2 stage heating is in use to achieve desired temperature">
<optionalConform>
<feature name="HEAT"/>
</optionalConform>
</item>
<item value="6" name="Precooling" summary="(see ref_HvacTerms)">
<optionalConform>
<feature name="COOL"/>
</optionalConform>
</item>
<item value="7" name="FanOnly">
<optionalConform/>
</item>
<item value="8" name="Dry">
<optionalConform/>
</item>
<item value="9" name="Sleep">
<optionalConform/>
</item>
</enum>
<enum name="TemperatureSetpointHoldEnum">
<item value="0" name="SetpointHoldOff" summary="Follow scheduling program">
<mandatoryConform/>
</item>
<item value="1" name="SetpointHoldOn" summary="Maintain current setpoint, regardless of schedule transitions">
<mandatoryConform/>
</item>
</enum>
<enum name="ThermostatRunningModeEnum">
<item value="0" name="Off" summary="The Thermostat does not generate demand for Cooling or Heating">
<optionalConform/>
</item>
<item value="3" name="Cool" summary="Demand is only generated for Cooling">
<optionalConform>
<feature name="COOL"/>
</optionalConform>
</item>
<item value="4" name="Heat" summary="Demand is only generated for Heating">
<optionalConform>
<feature name="HEAT"/>
</optionalConform>
</item>
</enum>
<bitmap name="ACErrorCodeBitmap">
<bitfield name="CompressorFail" bit="0" summary="Compressor Failure or Refrigerant Leakage">
<mandatoryConform/>
</bitfield>
<bitfield name="RoomSensorFail" bit="1" summary="Room Temperature Sensor Failure">
<mandatoryConform/>
</bitfield>
<bitfield name="OutdoorSensorFail" bit="2" summary="Outdoor Temperature Sensor Failure">
<mandatoryConform/>
</bitfield>
<bitfield name="CoilSensorFail" bit="3" summary="Indoor Coil Temperature Sensor Failure">
<mandatoryConform/>
</bitfield>
<bitfield name="FanFail" bit="4" summary="Fan Failure">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="AlarmCodeBitmap">
<bitfield name="Initialization" bit="0" summary="Initialization failure. The device failed to complete initialization at power-up.">
<mandatoryConform/>
</bitfield>
<bitfield name="Hardware" bit="1" summary="Hardware failure">
<mandatoryConform/>
</bitfield>
<bitfield name="SelfCalibration" bit="2" summary="Self-calibration failure">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="HVACSystemTypeBitmap">
<bitfield name="CoolingStage" from="1" to="0" summary="Stage of cooling the HVAC system is using.">
<mandatoryConform/>
</bitfield>
<bitfield name="HeatingStage" from="3" to="2" summary="Stage of heating the HVAC system is using.">
<mandatoryConform/>
</bitfield>
<bitfield name="HeatingIsHeatPump" bit="4" summary="Is the heating type Heat Pump.">
<mandatoryConform/>
</bitfield>
<bitfield name="HeatingUsesFuel" bit="5" summary="Does the HVAC system use fuel.">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="OccupancyBitmap">
<bitfield name="Occupied" bit="0" summary="Indicates the occupancy state">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="PresetTypeFeaturesBitmap">
<bitfield name="Automatic" bit="0" summary="Preset may be automatically activated by the thermostat">
<mandatoryConform/>
</bitfield>
<bitfield name="SupportsNames" bit="1" summary="Preset supports user-provided names">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="ProgrammingOperationModeBitmap">
<bitfield name="ScheduleActive" bit="0" summary="Schedule programming mode. This enables any programmed weekly schedule configurations.">
<mandatoryConform/>
</bitfield>
<bitfield name="AutoRecovery" bit="1" summary="Auto/recovery mode">
<mandatoryConform/>
</bitfield>
<bitfield name="Economy" bit="2" summary="Economy/EnergyStar mode">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="RelayStateBitmap">
<bitfield name="Heat" bit="0" summary="Heat Stage On">
<mandatoryConform/>
</bitfield>
<bitfield name="Cool" bit="1" summary="Cool Stage On">
<mandatoryConform/>
</bitfield>
<bitfield name="Fan" bit="2" summary="Fan Stage On">
<mandatoryConform/>
</bitfield>
<bitfield name="HeatStage2" bit="3" summary="Heat 2 Stage On">
<mandatoryConform/>
</bitfield>
<bitfield name="CoolStage2" bit="4" summary="Cool 2 Stage On">
<mandatoryConform/>
</bitfield>
<bitfield name="FanStage2" bit="5" summary="Fan 2 Stage On">
<mandatoryConform/>
</bitfield>
<bitfield name="FanStage3" bit="6" summary="Fan 3 Stage On">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="RemoteSensingBitmap">
<bitfield name="LocalTemperature" bit="0" summary="Calculated Local Temperature is derived from a remote node">
<mandatoryConform/>
</bitfield>
<bitfield name="OutdoorTemperature" bit="1" summary="OutdoorTemperature is derived from a remote node"/>
<bitfield name="Occupancy" bit="2" summary="Occupancy is derived from a remote node">
<mandatoryConform>
<feature name="OCC"/>
</mandatoryConform>
</bitfield>
</bitmap>
<bitmap name="ScheduleDayOfWeekBitmap">
<bitfield name="Sunday" bit="0" summary="Sunday">
<mandatoryConform/>
</bitfield>
<bitfield name="Monday" bit="1" summary="Monday">
<mandatoryConform/>
</bitfield>
<bitfield name="Tuesday" bit="2" summary="Tuesday">
<mandatoryConform/>
</bitfield>
<bitfield name="Wednesday" bit="3" summary="Wednesday">
<mandatoryConform/>
</bitfield>
<bitfield name="Thursday" bit="4" summary="Thursday">
<mandatoryConform/>
</bitfield>
<bitfield name="Friday" bit="5" summary="Friday">
<mandatoryConform/>
</bitfield>
<bitfield name="Saturday" bit="6" summary="Saturday">
<mandatoryConform/>
</bitfield>
<bitfield name="Away" bit="7" summary="Away or Vacation">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="ScheduleModeBitmap">
<bitfield name="HeatSetpointPresent" bit="0" summary="Adjust Heat Setpoint">
<mandatoryConform/>
</bitfield>
<bitfield name="CoolSetpointPresent" bit="1" summary="Adjust Cool Setpoint">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="ScheduleTypeFeaturesBitmap">
<bitfield name="SupportsPresets" bit="0" summary="Supports presets">
<optionalConform choice="b" more="true">
<feature name="PRES"/>
</optionalConform>
</bitfield>
<bitfield name="SupportsSetpoints" bit="1" summary="Supports setpoints">
<optionalConform choice="b" more="true"/>
</bitfield>
<bitfield name="SupportsNames" bit="2" summary="Supports user-provided names">
<optionalConform/>
</bitfield>
<bitfield name="SupportsOff" bit="3" summary="Supports transitioning to SystemModeOff">
<optionalConform/>
</bitfield>
</bitmap>
<struct name="PresetStruct">
<field id="0" name="PresetHandle" type="octstr">
<quality nullable="true"/>
<mandatoryConform/>
<constraint type="maxLength" value="16"/>
</field>
<field id="1" name="PresetScenario" type="PresetScenarioEnum">
<mandatoryConform/>
</field>
<field id="2" name="Name" type="string" default="null">
<quality nullable="true"/>
<optionalConform/>
<constraint type="maxLength" value="64"/>
</field>
<field id="3" name="CoolingSetpoint" type="temperature" default="26°C">
<mandatoryConform>
<feature name="COOL"/>
</mandatoryConform>
<constraint type="desc"/>
</field>
<field id="4" name="HeatingSetpoint" type="temperature" default="20°C">
<mandatoryConform>
<feature name="HEAT"/>
</mandatoryConform>
<constraint type="desc"/>
</field>
<field id="5" name="BuiltIn" type="bool" default="false">
<quality nullable="true"/>
<mandatoryConform/>
</field>
</struct>
<struct name="PresetTypeStruct">
<field id="0" name="PresetScenario" type="PresetScenarioEnum">
<mandatoryConform/>
</field>
<field id="1" name="NumberOfPresets" type="uint8" default="0">
<mandatoryConform/>
</field>
<field id="2" name="PresetTypeFeatures" type="PresetTypeFeaturesBitmap" default="0">
<mandatoryConform/>
</field>
</struct>
<struct name="ScheduleStruct">
<field id="0" name="ScheduleHandle" type="octstr">
<quality nullable="true"/>
<mandatoryConform/>
<constraint type="maxLength" value="16"/>
</field>
<field id="1" name="SystemMode" type="SystemModeEnum">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="2" name="Name" type="string">
<optionalConform/>
<constraint type="maxLength" value="64"/>
</field>
<field id="3" name="PresetHandle" type="octstr">
<optionalConform/>
<constraint type="maxLength" value="16"/>
</field>
<field id="4" name="Transitions" type="list" default="empty">
<entry type="ScheduleTransitionStruct"/>
<mandatoryConform/>
<constraint type="countBetween" from="1" to="NumberOfScheduleTransitions Attribute"/>
</field>
<field id="5" name="BuiltIn" type="bool" default="false">
<quality nullable="true"/>
<mandatoryConform/>
</field>
</struct>
<struct name="ScheduleTransitionStruct">
<field id="0" name="DayOfWeek" type="ScheduleDayOfWeekBitmap">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="1" name="TransitionTime" type="uint16">
<mandatoryConform/>
<constraint type="max" value="1439"/>
</field>
<field id="2" name="PresetHandle" type="octstr">
<optionalConform>
<feature name="PRES"/>
</optionalConform>
<constraint type="maxLength" value="16"/>
</field>
<field id="3" name="SystemMode" type="SystemModeEnum">
<optionalConform/>
<constraint type="desc"/>
</field>
<field id="4" name="CoolingSetpoint" type="temperature">
<optionalConform>
<feature name="COOL"/>
</optionalConform>
<constraint type="desc"/>
</field>
<field id="5" name="HeatingSetpoint" type="temperature">
<optionalConform>
<feature name="HEAT"/>
</optionalConform>
<constraint type="desc"/>
</field>
</struct>
<struct name="ScheduleTypeStruct">
<field id="0" name="SystemMode" type="SystemModeEnum">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="1" name="NumberOfSchedules" type="uint8" default="0">
<mandatoryConform/>
<constraint type="max" value="NumberOfSchedules Attribute"/>
</field>
<field id="2" name="ScheduleTypeFeatures" type="ScheduleTypeFeaturesBitmap" default="0">
<mandatoryConform/>
<constraint type="desc"/>
</field>
</struct>
<struct name="WeeklyScheduleTransitionStruct">
<field id="0" name="TransitionTime" type="uint16">
<mandatoryConform/>
<constraint type="max" value="1439"/>
</field>
<field id="1" name="HeatSetpoint" type="temperature">
<quality nullable="true"/>
<mandatoryConform/>
</field>
<field id="2" name="CoolSetpoint" type="temperature">
<quality nullable="true"/>
<mandatoryConform/>
</field>
</struct>
</dataTypes>
<attributes>
<attribute id="0x0000" name="LocalTemperature" type="temperature" default="null">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="true" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform/>
</attribute>
<attribute id="0x0001" name="OutdoorTemperature" type="temperature" default="null">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
</attribute>
<attribute id="0x0002" name="Occupancy" type="OccupancyBitmap" default="1">
<access read="true" readPrivilege="view"/>
<mandatoryConform>
<feature name="OCC"/>
</mandatoryConform>
</attribute>
<attribute id="0x0003" name="AbsMinHeatSetpointLimit" type="temperature" default="7°C">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform>
<feature name="HEAT"/>
</optionalConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0004" name="AbsMaxHeatSetpointLimit" type="temperature" default="30°C">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform>
<feature name="HEAT"/>
</optionalConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0005" name="AbsMinCoolSetpointLimit" type="temperature" default="16°C">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform>
<feature name="COOL"/>
</optionalConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0006" name="AbsMaxCoolSetpointLimit" type="temperature" default="32°C">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform>
<feature name="COOL"/>
</optionalConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0007" name="PICoolingDemand" type="uint8" default="-">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="volatile" reportable="true" sourceAttribution="false" quieterReporting="false"/>
<optionalConform>
<feature name="COOL"/>
</optionalConform>
<constraint type="between" from="0%" to="100%"/>
</attribute>
<attribute id="0x0008" name="PIHeatingDemand" type="uint8" default="-">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="volatile" reportable="true" sourceAttribution="false" quieterReporting="false"/>
<optionalConform>
<feature name="HEAT"/>
</optionalConform>
<constraint type="between" from="0%" to="100%"/>
</attribute>
<attribute id="0x0009" name="HVACSystemTypeConfiguration" type="HVACSystemTypeBitmap" default="0">
<access read="true" write="optional" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<deprecateConform/>
<constraint type="desc"/>
</attribute>
<attribute id="0x0010" name="LocalTemperatureCalibration" type="SignedTemperature" default="0°C">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform>
<notTerm>
<feature name="LTNE"/>
</notTerm>
</optionalConform>
</attribute>
<attribute id="0x0011" name="OccupiedCoolingSetpoint" type="temperature" default="26°C">
<access read="true" write="true" readPrivilege="view" writePrivilege="operate"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="COOL"/>
</mandatoryConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0012" name="OccupiedHeatingSetpoint" type="temperature" default="20°C">
<access read="true" write="true" readPrivilege="view" writePrivilege="operate"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="HEAT"/>
</mandatoryConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0013" name="UnoccupiedCoolingSetpoint" type="temperature" default="26°C">
<access read="true" write="true" readPrivilege="view" writePrivilege="operate"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<andTerm>
<feature name="COOL"/>
<feature name="OCC"/>
</andTerm>
</mandatoryConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0014" name="UnoccupiedHeatingSetpoint" type="temperature" default="20°C">
<access read="true" write="true" readPrivilege="view" writePrivilege="operate"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<andTerm>
<feature name="HEAT"/>
<feature name="OCC"/>
</andTerm>
</mandatoryConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0015" name="MinHeatSetpointLimit" type="temperature" default="AbsMinHeatSetpointLimit">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform>
<feature name="HEAT"/>
</optionalConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0016" name="MaxHeatSetpointLimit" type="temperature" default="AbsMaxHeatSetpointLimit">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform>
<feature name="HEAT"/>
</optionalConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0017" name="MinCoolSetpointLimit" type="temperature" default="AbsMinCoolSetpointLimit">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform>
<feature name="COOL"/>
</optionalConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0018" name="MaxCoolSetpointLimit" type="temperature" default="AbsMaxCoolSetpointLimit">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform>
<feature name="COOL"/>
</optionalConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0019" name="MinSetpointDeadBand" type="SignedTemperature" default="2.5°C">
<access read="true" write="optional" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="AUTO"/>
</mandatoryConform>
<constraint type="between" from="0" to="12.7°C"/>
</attribute>
<attribute id="0x001A" name="RemoteSensing" type="RemoteSensingBitmap" default="0">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
<constraint type="allowed" value="0b0000 0xxx"/>
</attribute>
<attribute id="0x001B" name="ControlSequenceOfOperation" type="ControlSequenceOfOperationEnum" default="4">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform/>
<constraint type="desc"/>
</attribute>
<attribute id="0x001C" name="SystemMode" type="SystemModeEnum" default="1">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform/>
<constraint type="desc"/>
</attribute>
<attribute id="0x001D" name="AlarmMask" type="AlarmCodeBitmap" default="0">
<access read="true" readPrivilege="view"/>
<optionalConform>
<condition name="Zigbee"/>
</optionalConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x001E" name="ThermostatRunningMode" type="ThermostatRunningModeEnum" default="0">
<access read="true" readPrivilege="view"/>
<optionalConform>
<feature name="AUTO"/>
</optionalConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0020" name="StartOfWeek" type="StartOfWeekEnum" default="–">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="SCH"/>
</mandatoryConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0021" name="NumberOfWeeklyTransitions" type="uint8" default="0">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="SCH"/>
</mandatoryConform>
</attribute>
<attribute id="0x0022" name="NumberOfDailyTransitions" type="uint8" default="0">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="SCH"/>
</mandatoryConform>
</attribute>
<attribute id="0x0023" name="TemperatureSetpointHold" type="TemperatureSetpointHoldEnum" default="0">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
<constraint type="desc"/>
</attribute>
<attribute id="0x0024" name="TemperatureSetpointHoldDuration" type="uint16" default="null">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
<constraint type="max" value="1440"/>
</attribute>
<attribute id="0x0025" name="ThermostatProgrammingOperationMode" type="ProgrammingOperationModeBitmap" default="0">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="volatile" reportable="true" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
<constraint type="desc"/>
</attribute>
<attribute id="0x0029" name="ThermostatRunningState" type="RelayStateBitmap" default="-">
<access read="true" readPrivilege="view"/>
<optionalConform/>
<constraint type="desc"/>
</attribute>
<attribute id="0x0030" name="SetpointChangeSource" type="SetpointChangeSourceEnum" default="0">
<access read="true" readPrivilege="view"/>
<optionalConform/>
<constraint type="desc"/>
</attribute>
<attribute id="0x0031" name="SetpointChangeAmount" type="TemperatureDifference" default="null">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
</attribute>
<attribute id="0x0032" name="SetpointChangeSourceTimestamp" type="utc" default="0">
<access read="true" readPrivilege="view"/>
<optionalConform/>
</attribute>
<attribute id="0x0034" name="OccupiedSetback" type="UnsignedTemperature" default="null">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="SB"/>
</mandatoryConform>
<constraint type="between" from="OccupiedSetbackMin" to="OccupiedSetbackMax"/>
</attribute>
<attribute id="0x0035" name="OccupiedSetbackMin" type="UnsignedTemperature" default="null">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="SB"/>
</mandatoryConform>
<constraint type="max" value="OccupiedSetbackMax"/>
</attribute>
<attribute id="0x0036" name="OccupiedSetbackMax" type="UnsignedTemperature" default="null">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="SB"/>
</mandatoryConform>
<constraint type="between" from="OccupiedSetbackMin" to="25.4°C"/>
</attribute>
<attribute id="0x0037" name="UnoccupiedSetback" type="UnsignedTemperature" default="null">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<andTerm>
<feature name="SB"/>
<feature name="OCC"/>
</andTerm>
</mandatoryConform>
<constraint type="between" from="UnoccupiedSetbackMin" to="UnoccupiedSetbackMax"/>
</attribute>
<attribute id="0x0038" name="UnoccupiedSetbackMin" type="UnsignedTemperature" default="null">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<andTerm>
<feature name="SB"/>
<feature name="OCC"/>
</andTerm>
</mandatoryConform>
<constraint type="max" value="UnoccupiedSetbackMax"/>
</attribute>
<attribute id="0x0039" name="UnoccupiedSetbackMax" type="UnsignedTemperature" default="null">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<andTerm>
<feature name="SB"/>
<feature name="OCC"/>
</andTerm>
</mandatoryConform>
<constraint type="between" from="UnoccupiedSetbackMin" to="25.4°C"/>
</attribute>
<attribute id="0x003A" name="EmergencyHeatDelta" type="UnsignedTemperature" default="25.5°C">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
</attribute>
<attribute id="0x0040" name="ACType" type="ACTypeEnum" default="0">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
<constraint type="desc"/>
</attribute>
<attribute id="0x0041" name="ACCapacity" type="uint16" default="0">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
</attribute>
<attribute id="0x0042" name="ACRefrigerantType" type="ACRefrigerantTypeEnum" default="0">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
<constraint type="desc"/>
</attribute>
<attribute id="0x0043" name="ACCompressorType" type="ACCompressorTypeEnum" default="0">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
<constraint type="desc"/>
</attribute>
<attribute id="0x0044" name="ACErrorCode" type="ACErrorCodeBitmap" default="0">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<optionalConform/>
</attribute>
<attribute id="0x0045" name="ACLouverPosition" type="ACLouverPositionEnum" default="0">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
<constraint type="desc"/>
</attribute>
<attribute id="0x0046" name="ACCoilTemperature" type="temperature" default="null">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
</attribute>
<attribute id="0x0047" name="ACCapacityFormat" type="ACCapacityFormatEnum" default="0">
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
<constraint type="desc"/>
</attribute>
<attribute id="0x0048" name="PresetTypes" type="list" default="MS">
<entry type="PresetTypeStruct"/>
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="PRES"/>
</mandatoryConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0049" name="ScheduleTypes" type="list" default="MS">
<entry type="ScheduleTypeStruct"/>
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="MSCH"/>
</mandatoryConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x004A" name="NumberOfPresets" type="uint8" default="0">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="PRES"/>
</mandatoryConform>
</attribute>
<attribute id="0x004B" name="NumberOfSchedules" type="uint8" default="0">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="MSCH"/>
</mandatoryConform>
</attribute>
<attribute id="0x004C" name="NumberOfScheduleTransitions" type="uint8" default="0">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="MSCH"/>
</mandatoryConform>
</attribute>
<attribute id="0x004D" name="NumberOfScheduleTransitionPerDay" type="uint8" default="null">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="MSCH"/>
</mandatoryConform>
</attribute>
<attribute id="0x004E" name="ActivePresetHandle" type="octstr" default="null">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="PRES"/>
</mandatoryConform>
<constraint type="maxLength" value="16"/>
</attribute>
<attribute id="0x004F" name="ActiveScheduleHandle" type="octstr" default="null">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="MSCH"/>
</mandatoryConform>
<constraint type="maxLength" value="16"/>
</attribute>
<attribute id="0x0050" name="Presets" type="list" default="empty">
<entry type="PresetStruct"/>
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="PRES"/>
</mandatoryConform>
<constraint type="maxCount" value="NumberOfPresets"/>
</attribute>
<attribute id="0x0051" name="Schedules" type="list" default="empty">
<entry type="ScheduleStruct"/>
<access read="true" write="true" readPrivilege="view" writePrivilege="manage"/>
<quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<mandatoryConform>
<feature name="MSCH"/>
</mandatoryConform>
<constraint type="desc"/>
</attribute>
<attribute id="0x0052" name="SetpointHoldExpiryTimestamp" type="epoch-s" default="null">
<access read="true" readPrivilege="view"/>
<quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/>
<optionalConform/>
</attribute>
</attributes>
<commands>
<command id="0x00" name="SetpointRaiseLower" direction="commandToServer" response="Y">
<access invokePrivilege="operate"/>
<mandatoryConform/>
<field id="0" name="Mode" type="SetpointRaiseLowerModeEnum">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="1" name="Amount" type="int8">
<mandatoryConform/>
</field>
</command>
<command id="0x00" name="GetWeeklyScheduleResponse" direction="responseFromServer">
<mandatoryConform>
<feature name="SCH"/>
</mandatoryConform>
<field id="0" name="NumberOfTransitionsForSequence" type="uint8">
<mandatoryConform/>
</field>
<field id="1" name="DayOfWeekForSequence" type="ScheduleDayOfWeekBitmap">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="2" name="ModeForSequence" type="ScheduleModeBitmap">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="3" name="Transitions" type="list">
<entry type="WeeklyScheduleTransitionStruct"/>
<mandatoryConform/>
<constraint type="maxCount" value="10"/>
</field>
</command>
<command id="0x01" name="SetWeeklySchedule" direction="commandToServer" response="Y">
<access invokePrivilege="manage"/>
<mandatoryConform>
<feature name="SCH"/>
</mandatoryConform>
<field id="0" name="NumberOfTransitionsForSequence" type="uint8">
<mandatoryConform/>
</field>
<field id="1" name="DayOfWeekForSequence" type="ScheduleDayOfWeekBitmap">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="2" name="ModeForSequence" type="ScheduleModeBitmap">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="3" name="Transitions" type="list">
<entry type="WeeklyScheduleTransitionStruct"/>
<mandatoryConform/>
<constraint type="maxCount" value="10"/>
</field>
</command>
<command id="0x01" name="GetRelayStatusLogResponse" direction="responseFromServer">
<mandatoryConform>
<command name="GetRelayStatusLog"/>
</mandatoryConform>
<field id="0" name="TimeOfDay" type="uint16">
<mandatoryConform/>
<constraint type="max" value="1439"/>
</field>
<field id="1" name="RelayStatus" type="RelayStateBitmap">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="2" name="LocalTemperature" type="temperature">
<quality nullable="true"/>
<mandatoryConform/>
</field>
<field id="3" name="HumidityInPercentage" type="uint8">
<quality nullable="true"/>
<mandatoryConform/>
<constraint type="between" from="0%" to="100%"/>
</field>
<field id="4" name="SetPoint" type="temperature">
<mandatoryConform/>
</field>
<field id="5" name="UnreadEntries" type="uint16">
<mandatoryConform/>
</field>
</command>
<command id="0x02" name="GetWeeklySchedule" direction="commandToServer" response="GetWeeklyScheduleResponse">
<access invokePrivilege="operate"/>
<mandatoryConform>
<feature name="SCH"/>
</mandatoryConform>
<field id="0" name="DaysToReturn" type="ScheduleDayOfWeekBitmap">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="1" name="ModeToReturn" type="ScheduleModeBitmap">
<mandatoryConform/>
<constraint type="desc"/>
</field>
</command>
<command id="0x03" name="ClearWeeklySchedule" direction="commandToServer" response="Y">
<access invokePrivilege="manage"/>
<mandatoryConform>
<feature name="SCH"/>
</mandatoryConform>
</command>
<command id="0x04" name="GetRelayStatusLog" direction="commandToServer" response="GetRelayStatusLogResponse">
<access invokePrivilege="operate"/>
<optionalConform>
<condition name="Zigbee"/>
</optionalConform>
</command>
<command id="0x05" name="SetActiveScheduleRequest" direction="commandToServer" response="Y">
<access invokePrivilege="operate"/>
<mandatoryConform>
<feature name="MSCH"/>
</mandatoryConform>
<field id="0" name="ScheduleHandle" type="octstr">
<mandatoryConform/>
<constraint type="maxLength" value="16"/>
</field>
</command>
<command id="0x06" name="SetActivePresetRequest" direction="commandToServer" response="Y">
<access invokePrivilege="operate"/>
<mandatoryConform>
<feature name="PRES"/>
</mandatoryConform>
<field id="0" name="PresetHandle" type="octstr">
<quality nullable="true"/>
<mandatoryConform/>
<constraint type="maxLength" value="16"/>
</field>
</command>
</commands>
</cluster>