| # List of currently defined spec clusters |
| This file was **AUTOMATICALLY** generated by `python scripts/generate_spec_xml.py`. DO NOT EDIT BY HAND! |
| |
| |
| The following markers are used in this document (matches the ID master list): |
| | State | Description | |
| |-------|--------------------------------| |
| | blank | Not supported in this revision | |
| | C | Certifiable | |
| | P | Provisional | |
| |
| | ID (Decimal) | ID (hex) | Name | PICS Code |1.0|1.1|1.2|1.3|1.4|1.4.1|1.4.2|1.5|1.5.1|1.6|1.6.1| |
| |--------------|----------|----------------------------------------------------------|---------------|---|---|---|---|---|-----|-----|---|-----|---|-----| |
| |3 |0x0003 |Identify |I |C |C |C |C |C |C |C |C |C |C |C | |
| |4 |0x0004 |Groups |G |C |C |C |C |C |C |C |C |C |C |C | |
| |5 |0x0005 |Scenes |S |C |C |C | | | | | | | | | |
| |6 |0x0006 |On/Off |OO |C |C |C |C |C |C |C |C |C |C |C | |
| |8 |0x0008 |Level Control |LVL |C |C |C |C |C |C |C |C |C |C |C | |
| |28 |0x001C |Pulse Width Modulation |PWM |C |C |C |P | | | | | | | | |
| |29 |0x001D |Descriptor |DESC |C |C |C |C |C |C |C |C |C |C |C | |
| |30 |0x001E |Binding |BIND |C |C |C |C |C |C |C |C |C |C |C | |
| |31 |0x001F |Access Control |ACL |C |C |C |C |C |C |C |C |C |C |C | |
| |37 |0x0025 |Actions |ACT |C |C |C |C |C |C |C |C |C |C |C | |
| |40 |0x0028 |Basic Information |BINFO |C |C |C |C |C |C |C |C |C |C |C | |
| |41 |0x0029 |OTA Software Update Provider |OTAP |C |C |C |C |C |C |C |C |C |C |C | |
| |42 |0x002A |OTA Software Update Requestor |OTAR |C |C |C |C |C |C |C |C |C |C |C | |
| |43 |0x002B |Localization Configuration |LCFG |C |C |C |C |C |C |C |C |C |C |C | |
| |44 |0x002C |Time Format Localization |LTIME |C |C |C |C |C |C |C |C |C |C |C | |
| |45 |0x002D |Unit Localization |LUNIT |C |C |C |C |C |C |C |C |C |C |C | |
| |46 |0x002E |Power Source Configuration |PSCFG |C |C |C |C |C |C |C |C |C |C |C | |
| |47 |0x002F |Power Source |PS |C |C |C |C |C |C |C |C |C |C |C | |
| |48 |0x0030 |General Commissioning |CGEN |C |C |C |C |C |C |C |C |C |C |C | |
| |49 |0x0031 |Network Commissioning |CNET |C |C |C |C |C |C |C |C |C |C |C | |
| |50 |0x0032 |Diagnostic Logs |DLOG |C |C |C |C |C |C |C |C |C |C |C | |
| |51 |0x0033 |General Diagnostics |DGGEN |C |C |C |C |C |C |C |C |C |C |C | |
| |52 |0x0034 |Software Diagnostics |DGSW |C |C |C |C |C |C |C |C |C |C |C | |
| |53 |0x0035 |Thread Network Diagnostics |DGTHREAD |C |C |C |C |C |C |C |C |C |C |C | |
| |54 |0x0036 |Wi-Fi Network Diagnostics |DGWIFI |C |C |C |C |C |C |C |C |C |C |C | |
| |55 |0x0037 |Ethernet Network Diagnostics |DGETH |C |C |C |C |C |C |C |C |C |C |C | |
| |56 |0x0038 |Time Synchronization |TIMESYNC |C |C |C |C |C |C |C |C |C |C |C | |
| |57 |0x0039 |Bridged Device Basic Information |BRBINFO |C |C |C |C |C |C |C |C |C |C |C | |
| |59 |0x003B |Switch |SWTCH |C |C |C |C |C |C |C |C |C |C |C | |
| |60 |0x003C |Administrator Commissioning |CADMIN |C |C |C |C |C |C |C |C |C |C |C | |
| |62 |0x003E |Operational Credentials |OPCREDS |C |C |C |C |C |C |C |C |C |C |C | |
| |63 |0x003F |Group Key Management |GRPKEY |C |C |C |C |C |C |C |C |C |C |C | |
| |64 |0x0040 |Fixed Label |FLABEL |C |C |C |C |C |C |C |C |C |C |C | |
| |65 |0x0041 |User Label |ULABEL |C |C |C |C |C |C |C |C |C |C |C | |
| |66 |0x0042 |Proxy Configuration |PXCFG |C |C |C |P |P |P | | | | | | |
| |67 |0x0043 |Proxy Discovery |PXDSC |C |C |C |P |P |P | | | | | | |
| |68 |0x0044 |Valid Proxies |PXVALID |C |C |C |P |P |P | | | | | | |
| |69 |0x0045 |Boolean State |BOOL |C |C |C |C |C |C |C |C |C |C |C | |
| |70 |0x0046 |ICD Management |ICDM | | |C |C |C |C |C |C |C |C |C | |
| |72 |0x0048 |Oven Cavity Operational State |OVENOPSTATE | | | |C |C |C |C |C |C |C |C | |
| |73 |0x0049 |Oven Mode |OTCCM | | | |C |C |C |C |C |C |C |C | |
| |74 |0x004A |Laundry Dryer Controls |DRYERCTRL | | | |C |C |C |C |C |C |C |C | |
| |80 |0x0050 |Mode Select |MOD |C |C |C |C |C |C |C |C |C |C |C | |
| |81 |0x0051 |Laundry Washer Mode |LWM | | |C |C |C |C |C |C |C |C |C | |
| |82 |0x0052 |Refrigerator And Temperature Controlled Cabinet Mode |TCCM | | |C |C |C |C |C |C |C |C |C | |
| |83 |0x0053 |Laundry Washer Controls |WASHERCTRL | | |C |C |C |C |C |C |C |C |C | |
| |84 |0x0054 |RVC Run Mode |RVCRUNM | | |C |C |C |C |C |C |C |C |C | |
| |85 |0x0055 |RVC Clean Mode |RVCCLEANM | | |C |C |C |C |C |C |C |C |C | |
| |86 |0x0056 |Temperature Control |TCTL | | |C |C |C |C |C |C |C |C |C | |
| |87 |0x0057 |Refrigerator Alarm |REFALM | | |C |C |C |C |C |C |C |C |C | |
| |89 |0x0059 |Dishwasher Mode |DISHM | | |C |C |C |C |C |C |C |C |C | |
| |91 |0x005B |Air Quality |AIRQUAL | | |C |C |C |C |C |C |C |C |C | |
| |92 |0x005C |Smoke CO Alarm |SMOKECO | | |C |C |C |C |C |C |C |C |C | |
| |93 |0x005D |Dishwasher Alarm |DISHALM | | |C |C |C |C |C |C |C |C |C | |
| |94 |0x005E |Microwave Oven Mode |MWOM | | | |C |C |C |C |C |C |C |C | |
| |95 |0x005F |Microwave Oven Control |MWOCTRL | | | |C |C |C |C |C |C |C |C | |
| |96 |0x0060 |Operational State |OPSTATE | | |C |C |C |C |C |C |C |C |C | |
| |97 |0x0061 |RVC Operational State |RVCOPSTATE | | |C |C |C |C |C |C |C |C |C | |
| |98 |0x0062 |Scenes Management |S | | | |P |P |P |C |C |C |C |C | |
| |100 |0x0064 |Temperature Alarm |TEMPALM | | | | | | | | | |P |P | |
| |101 |0x0065 |Groupcast |GC | | | | | | | | | |P |P | |
| |113 |0x0071 |HEPA Filter Monitoring |HEPAFREMON | | |C |C |C |C |C |C |C |C |C | |
| |114 |0x0072 |Activated Carbon Filter Monitoring |ACFREMON | | |C |C |C |C |C |C |C |C |C | |
| |121 |0x0079 |Water Tank Level Monitoring |REPM | | | | |C |C |C |C |C |C |C | |
| |128 |0x0080 |Boolean State Configuration |BOOLCFG | | | |C |C |C |C |C |C |C |C | |
| |129 |0x0081 |Valve Configuration and Control |VALCC | | | |C |C |C |C |C |C |C |C | |
| |144 |0x0090 |Electrical Power Measurement |EPM | | | |C |C |C |C |C |C |C |C | |
| |145 |0x0091 |Electrical Energy Measurement |EEM | | | |C |C |C |C |C |C |C |C | |
| |148 |0x0094 |Water Heater Management |EWATERHTR | | | | |C |C |C |C |C |C |C | |
| |149 |0x0095 |Commodity Price |SEPR | | | | | | | |C |C |C |C | |
| |151 |0x0097 |Messages |MESS | | | |C |C |C |C |C |C |C |C | |
| |152 |0x0098 |Device Energy Management |DEM | | | |P |C |C |C |C |C |C |C | |
| |153 |0x0099 |Energy EVSE |EEVSE | | | |C |C |C |C |C |C |C |C | |
| |155 |0x009B |Energy Preference |EPREF | | | |P |P |P |P |P |P |C |C | |
| |156 |0x009C |Power Topology |PWRTL | | | |C |C |C |C |C |C |C |C | |
| |157 |0x009D |Energy EVSE Mode |EEVSEM | | | |C |C |C |C |C |C |C |C | |
| |158 |0x009E |Water Heater Mode |WHM | | | | |C |C |C |C |C |C |C | |
| |159 |0x009F |Device Energy Management Mode |DEMM | | | |P |C |C |C |C |C |C |C | |
| |160 |0x00A0 |Electrical Grid Conditions |EGC | | | | | | | |C |C |C |C | |
| |257 |0x0101 |Door Lock |DRLK |C |C |C |C |C |C |C |C |C |C |C | |
| |258 |0x0102 |Window Covering |WNCV |C |C |C |C |C |C |C |C |C |C |C | |
| |260 |0x0104 |Closure Control |CLCTRL | | | | | | | |C |C |C |C | |
| |261 |0x0105 |Closure Dimension |CLDIM | | | | | | | |C |C |C |C | |
| |336 |0x0150 |Service Area |SEAR | | | | |C |C |C |C |C |C |C | |
| |512 |0x0200 |Pump Configuration and Control |PCC |C |C |C |C |C |C |C |C |C |C |C | |
| |513 |0x0201 |Thermostat |TSTAT |C |C |C |C |C |C |C |C |C |C |C | |
| |514 |0x0202 |Fan Control |FAN |C |C |C |C |C |C |C |C |C |C |C | |
| |516 |0x0204 |Thermostat User Interface Configuration |TSUIC |C |C |C |C |C |C |C |C |C |C |C | |
| |768 |0x0300 |Color Control |CC |C |C |C |C |C |C |C |C |C |C |C | |
| |769 |0x0301 |Ballast Configuration |BC |C |C |C |P |P |P | | | | | | |
| |1024 |0x0400 |Illuminance Measurement |ILL |C |C |C |C |C |C |C |C |C |C |C | |
| |1026 |0x0402 |Temperature Measurement |TMP |C |C |C |C |C |C |C |C |C |C |C | |
| |1027 |0x0403 |Pressure Measurement |PRS |C |C |C |C |C |C |C |C |C |C |C | |
| |1028 |0x0404 |Flow Measurement |FLW |C |C |C |C |C |C |C |C |C |C |C | |
| |1029 |0x0405 |Relative Humidity Measurement |RH |C |C |C |C |C |C |C |C |C |C |C | |
| |1030 |0x0406 |Occupancy Sensing |OCC |C |C |C |C |C |C |C |C |C |C |C | |
| |1031 |0x0407 |Leaf Wetness Measurement |RH |C |C |C | | | | | | | | | |
| |1032 |0x0408 |Soil Moisture Measurement |RH |C |C |C | | | | | | | | | |
| |1036 |0x040C |Carbon Monoxide Concentration Measurement |CMOCONC | | |C |C |C |C |C |C |C |C |C | |
| |1037 |0x040D |Carbon Dioxide Concentration Measurement |CDOCONC | | |C |C |C |C |C |C |C |C |C | |
| |1043 |0x0413 |Nitrogen Dioxide Concentration Measurement |NDOCONC | | |C |C |C |C |C |C |C |C |C | |
| |1045 |0x0415 |Ozone Concentration Measurement |OZCONC | | |C |C |C |C |C |C |C |C |C | |
| |1066 |0x042A |PM2.5 Concentration Measurement |PMICONC | | |C |C |C |C |C |C |C |C |C | |
| |1067 |0x042B |Formaldehyde Concentration Measurement |FLDCONC | | |C |C |C |C |C |C |C |C |C | |
| |1068 |0x042C |PM1 Concentration Measurement |PMHCONC | | |C |C |C |C |C |C |C |C |C | |
| |1069 |0x042D |PM10 Concentration Measurement |PMKCONC | | |C |C |C |C |C |C |C |C |C | |
| |1070 |0x042E |Total Volatile Organic Compounds Concentration Measurement|TVOCCONC | | |C |C |C |C |C |C |C |C |C | |
| |1071 |0x042F |Radon Concentration Measurement |RNCONC | | |C |C |C |C |C |C |C |C |C | |
| |1072 |0x0430 |Soil Measurement |SOIL | | | | | | | |C |C |C |C | |
| |1073 |0x0431 |Ambient Context Sensing |ACS | | | | | | | | | |P |P | |
| |1105 |0x0451 |Wi-Fi Network Management |WIFINM | | | | |C |C |C |C |C |C |C | |
| |1106 |0x0452 |Thread Border Router Management |TBRM | | | | |C |C |C |C |C |C |C | |
| |1107 |0x0453 |Thread Network Directory |THNETDIR | | | | |C |C |C |C |C |C |C | |
| |1283 |0x0503 |Wake On LAN |WAKEONLAN |C |C |C |C |C |C |C |C |C |C |C | |
| |1284 |0x0504 |Channel |CHANNEL |C |C |C |C |C |C |C |C |C |C |C | |
| |1285 |0x0505 |Target Navigator |TGTNAV |C |C |C |C |C |C |C |C |C |C |C | |
| |1286 |0x0506 |Media Playback |MEDIAPLAYBACK |C |C |C |C |C |C |C |C |C |C |C | |
| |1287 |0x0507 |Media Input |MEDIAINPUT |C |C |C |C |C |C |C |C |C |C |C | |
| |1288 |0x0508 |Low Power |LOWPOWER |C |C |C |C |C |C |C |C |C |C |C | |
| |1289 |0x0509 |Keypad Input |KEYPADINPUT |C |C |C |C |C |C |C |C |C |C |C | |
| |1290 |0x050A |Content Launcher |CONTENTLAUNCHER|C |C |C |C |C |C |C |C |C |C |C | |
| |1291 |0x050B |Audio Output |AUDIOOUTPUT |C |C |C |C |C |C |C |C |C |C |C | |
| |1292 |0x050C |Application Launcher |APPLAUNCHER |C |C |C |C |C |C |C |C |C |C |C | |
| |1293 |0x050D |Application Basic |APBSC |C |C |C |C |C |C |C |C |C |C |C | |
| |1294 |0x050E |Account Login |ALOGIN |C |C |C |C |C |C |C |C |C |C |C | |
| |1295 |0x050F |Content Control |CONCON | | | |P |P |P |P |P |P |P |P | |
| |1296 |0x0510 |Content App Observer |APPOBSERVER | | | |C |C |C |C |C |C |C |C | |
| |1360 |0x0550 |Zone Management |ZONEMGMT | | | | | | | |C |C |C |C | |
| |1361 |0x0551 |Camera AV Stream Management |AVSM | | | | | | | |C |C |C |C | |
| |1362 |0x0552 |Camera AV Settings User Level Management |AVSUM | | | | | | | |C |C |C |C | |
| |1363 |0x0553 |WebRTC Transport Provider |WEBRTCP | | | | | | | |C |C |C |C | |
| |1364 |0x0554 |WebRTC Transport Requestor |WEBRTCR | | | | | | | |C |C |C |C | |
| |1365 |0x0555 |Push AV Stream Transport |PAVST | | | | | | | |C |C |C |C | |
| |1366 |0x0556 |Chime |CHIME | | | | | | | |C |C |C |C | |
| |1792 |0x0700 |Commodity Tariff |SETRF | | | | | | | |C |C |C |C | |
| |1872 |0x0750 |Ecosystem Information |ECOINFO | | | | |C |C |C |C |C |C |C | |
| |1873 |0x0751 |Commissioner Control |CCTRL | | | | |C |C |C |C |C |C |C | |
| |1874 |0x0752 |Joint Fabric Datastore |JFDS | | | | |P |P |P |P |P |C |C | |
| |1875 |0x0753 |Joint Fabric Administrator |JFADMIN | | | | |P |P |P |P |P |C |C | |
| |2049 |0x0801 |TLS Certificate Management |TLSCERT | | | | | | | |C |C |C |C | |
| |2050 |0x0802 |TLS Client Management |TLSCLIENT | | | | | | | |C |C |C |C | |
| |2822 |0x0B06 |Meter Identification |MTRID | | | | | | | |C |C |C |C | |
| |2823 |0x0B07 |Commodity Metering |COMMTR | | | | | | | |C |C |C |C | |