| * Copyright (c) 2015 Wind River Systems, Inc. |
| * |
| * SPDX-License-Identifier: Apache-2.0 |
| */ |
| |
| #ifndef _samples_include_tc_nano_timeout_common__h_ |
| #define _samples_include_tc_nano_timeout_common__h_ |
| |
| /* |
| * SHORT_TIMEOUTS should be the preferred configuration, but they cause a |
| * problem with the Jenkins auto-builders for the ARM QEMU. Until this is |
| * fixed, do not use them by default. |
| */ |
| #define SHORT_TIMEOUTS 0 |
| #if SHORT_TIMEOUTS |
| #define TIMEOUT_BASE 10 |
| #define TIMEOUT_INCREMENT 5 |
| #else |
| #define TIMEOUT_BASE 50 |
| #define TIMEOUT_INCREMENT 25 |
| #endif |
| #define TIMEOUT(x) (TIMEOUT_BASE + ((x) * TIMEOUT_INCREMENT)) |
| #define TIMEOUT_TWO_INTERVALS TIMEOUT(1) |
| #define TIMEOUT_TEN_INTERVALS TIMEOUT(9) |
| |
| /* |
| * Verify a timeout is in range, either a diff of 0 or 1 to account for tick |
| * boundaries. |
| */ |
| static inline int is_timeout_in_range(s32_t orig_ticks, s32_t expected) |
| { |
| s32_t diff = sys_tick_get() - orig_ticks; |
| |
| #if SHORT_TIMEOUTS |
| /* |
| * This should be the real test: however, there is an issue with the |
| * Jenkins auto-builders and QEMU for ARM, where (it seems) if the |
| * builder is overloaded, they do not give enough time to a QEMU instance |
| * so the Zephyr ticker can increment multiple times (so the interrupt |
| * handling happens) before the regular processing does occur, which gives |
| * the impression that more ticks have elapsed than expected. |
| */ |
| |
| if (diff != expected && diff != expected + 1) { |
| TC_ERROR(" *** timeout skew: expected %d/%d, got %d\n", |
| expected, expected + 1, diff); |
| return 0; |
| } |
| |
| /* TC_PRINT("timeout in range (%d vs %d)\n", diff, expected); */ |
| return 1; |
| #else |
| return diff >= expected; |
| #endif |
| } |
| |
| #endif /* _samples_include_tc_nano_timeout_common__h_ */ |