name: 3.2.2. [TC-BRBINFO-2.2] Events [DUT-Server]
config:
nodeId: 0x12344321
cluster: "Basic"
endpoint: 0
tests:
- label:
"Reboot the DUT (i.e. restart by power cycle, not by making it factory
new) TH receives the StartUp event from DUT"
PICS: BRBINFO.S.E00
verification: |
StartUp is an optional Event -
As its an optional event we cannot generate the event as of now , hence no example logs provided.
./chip-tool bridgeddevicebasic read-event start-up 1 3
disabled: true
- label:
"Make the device on the bridged endpoint unreachable across the
bridge, such that the Reachable attribute changes, in a
manufacturer-specific way, such as powering off or otherwise disabling
the bridged device or the connectivity to it."
PICS: BRBINFO.S.E03
verification: |
To verify thi ReachableChanged follow the below procedure
1. ./chip-tool interactive start
2. bridgeddevicebasic subscribe reachable 1 60 1 4
3. press "u" on bridge-app to change reachable to false for endpoint 4 and see the reachable value has been changed compared with precondition
[1659441181.388547][2392:2397] CHIP:TOO: Endpoint: 4 Cluster: 0x0000_0039 Attribute 0x0000_0011 DataVersion: 2189020906
[1659441181.388600][2392:2397] CHIP:TOO: Reachable: FALSE
[1659441181.388651][2392:2397] CHIP:DMG: MoveToState ReadClient[0xffff7c005ac0]: Moving to [AwaitingSu]
4. press "v" on bridge-app to change reachable to true for endpoint 4
[1659441193.443232][2392:2397] CHIP:TOO: Endpoint: 4 Cluster: 0x0000_0039 Attribute 0x0000_0011 DataVersion: 2189020907
[1659441193.443267][2392:2397] CHIP:TOO: Reachable: TRUE
[1659441193.443331][2392:2397] CHIP:EM: Piggybacking Ack for MessageCounter:194624180 on exchange: 18196r
disabled: true
- label: "TH subscribes to the shutdown event on the DUT. Shutdown DUT."
PICS: BRBINFO.S.E01
verification: |
ShutDown is an optional Event -
As its an optional event we cannot generate the event as of now , hence no example logs provided.
./chip-tool bridgeddevicebasic read-event shut-down 1 3
disabled: true