Fixed All Clusters App ZAP Test Script File (#25045)
* Fixed All Clusters App ZAP Test Script File
- Removed all Thread Network Diagnostics Cluster events, which are currently
not implemented in the SDK at all.
- Removed all Actions Cluster events, which are currently not implemented
in the SDK.
- Removed BatFaultChange event of the Power Source Cluster, which is not implemented
in the SDK..
- Removed StateChange event of the Boolean State Cluster, which is not implemented
for the All Clusters App.
- Removed all events of the Pump Configuration and Control Cluster, which are currently
not implemented in the SDK.
* ZAP REGENdiff --git a/scripts/tools/zap/tests/inputs/all-clusters-app.zap b/scripts/tools/zap/tests/inputs/all-clusters-app.zap
index 46c25d8..407375c 100644
--- a/scripts/tools/zap/tests/inputs/all-clusters-app.zap
+++ b/scripts/tools/zap/tests/inputs/all-clusters-app.zap
@@ -4885,22 +4885,6 @@
"maxInterval": 65344,
"reportableChange": 0
}
- ],
- "events": [
- {
- "name": "ConnectionStatus",
- "code": 0,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "NetworkFaultChange",
- "code": 1,
- "mfgCode": null,
- "side": "server",
- "included": 1
- }
]
},
{
@@ -10532,22 +10516,6 @@
"maxInterval": 65344,
"reportableChange": 0
}
- ],
- "events": [
- {
- "name": "StateChanged",
- "code": 0,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "ActionFailed",
- "code": 1,
- "mfgCode": null,
- "side": "server",
- "included": 1
- }
]
},
{
@@ -11664,15 +11632,6 @@
"maxInterval": 65344,
"reportableChange": 0
}
- ],
- "events": [
- {
- "name": "BatFaultChange",
- "code": 1,
- "mfgCode": null,
- "side": "server",
- "included": 1
- }
]
},
{
@@ -12524,15 +12483,6 @@
"maxInterval": 65534,
"reportableChange": 0
}
- ],
- "events": [
- {
- "name": "StateChange",
- "code": 0,
- "mfgCode": null,
- "side": "server",
- "included": 1
- }
]
},
{
@@ -14745,92 +14695,6 @@
"maxInterval": 65344,
"reportableChange": 0
}
- ],
- "events": [
- {
- "name": "SupplyVoltageLow",
- "code": 0,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "SupplyVoltageHigh",
- "code": 1,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "PowerMissingPhase",
- "code": 2,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "SystemPressureLow",
- "code": 3,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "SystemPressureHigh",
- "code": 4,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "DryRunning",
- "code": 5,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "MotorTemperatureHigh",
- "code": 6,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "PumpMotorFatalFailure",
- "code": 7,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "ElectronicTemperatureHigh",
- "code": 8,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "PumpBlocked",
- "code": 9,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "SensorFailure",
- "code": 10,
- "mfgCode": null,
- "side": "server",
- "included": 1
- },
- {
- "name": "ElectronicNonFatalFailure",
- "code": 11,
- "mfgCode": null,
- "side": "server",
- "included": 1
- }
]
},
{
diff --git a/scripts/tools/zap/tests/outputs/all-clusters-app/app-templates/endpoint_config.h b/scripts/tools/zap/tests/outputs/all-clusters-app/app-templates/endpoint_config.h
index 7ebc33a..e1fcdae 100644
--- a/scripts/tools/zap/tests/outputs/all-clusters-app/app-templates/endpoint_config.h
+++ b/scripts/tools/zap/tests/outputs/all-clusters-app/app-templates/endpoint_config.h
@@ -1492,7 +1492,7 @@
#define ZAP_GENERATED_COMMANDS_INDEX(index) (&generatedCommands[index])
// clang-format off
-#define GENERATED_EVENT_COUNT 41
+#define GENERATED_EVENT_COUNT 23
#define GENERATED_EVENTS { \
/* Endpoint: 0, Cluster: Access Control (server) */ \
/* EventList (index=0) */ \
@@ -1517,50 +1517,22 @@
/* Endpoint: 0, Cluster: Software Diagnostics (server) */ \
/* EventList (index=12) */ \
0x00000000, /* SoftwareFault */ \
- /* Endpoint: 0, Cluster: Thread Network Diagnostics (server) */ \
- /* EventList (index=13) */ \
- 0x00000000, /* ConnectionStatus */ \
- 0x00000001, /* NetworkFaultChange */ \
/* Endpoint: 0, Cluster: WiFi Network Diagnostics (server) */ \
- /* EventList (index=15) */ \
+ /* EventList (index=13) */ \
0x00000000, /* Disconnection */ \
0x00000001, /* AssociationFailure */ \
0x00000002, /* ConnectionStatus */ \
- /* Endpoint: 1, Cluster: Actions (server) */ \
- /* EventList (index=18) */ \
- 0x00000000, /* StateChanged */ \
- 0x00000001, /* ActionFailed */ \
- /* Endpoint: 1, Cluster: Power Source (server) */ \
- /* EventList (index=20) */ \
- 0x00000001, /* BatFaultChange */ \
/* Endpoint: 1, Cluster: Switch (server) */ \
- /* EventList (index=21) */ \
+ /* EventList (index=16) */ \
0x00000000, /* SwitchLatched */ \
- /* Endpoint: 1, Cluster: Boolean State (server) */ \
- /* EventList (index=22) */ \
- 0x00000000, /* StateChange */ \
/* Endpoint: 1, Cluster: Door Lock (server) */ \
- /* EventList (index=23) */ \
+ /* EventList (index=17) */ \
0x00000000, /* DoorLockAlarm */ \
0x00000002, /* LockOperation */ \
0x00000003, /* LockOperationError */ \
0x00000004, /* LockUserChange */ \
- /* Endpoint: 1, Cluster: Pump Configuration and Control (server) */ \
- /* EventList (index=27) */ \
- 0x00000000, /* SupplyVoltageLow */ \
- 0x00000001, /* SupplyVoltageHigh */ \
- 0x00000002, /* PowerMissingPhase */ \
- 0x00000003, /* SystemPressureLow */ \
- 0x00000004, /* SystemPressureHigh */ \
- 0x00000005, /* DryRunning */ \
- 0x00000006, /* MotorTemperatureHigh */ \
- 0x00000007, /* PumpMotorFatalFailure */ \
- 0x00000008, /* ElectronicTemperatureHigh */ \
- 0x00000009, /* PumpBlocked */ \
- 0x0000000A, /* SensorFailure */ \
- 0x0000000B, /* ElectronicNonFatalFailure */ \
/* Endpoint: 1, Cluster: Unit Testing (server) */ \
- /* EventList (index=39) */ \
+ /* EventList (index=21) */ \
0x00000001, /* TestEvent */ \
0x00000002, /* TestFabricScopedEvent */ \
}
@@ -2218,8 +2190,8 @@
.functions = NULL, \
.acceptedCommandList = ZAP_GENERATED_COMMANDS_INDEX( 44 ) ,\
.generatedCommandList = nullptr ,\
- .eventList = ZAP_GENERATED_EVENTS_INDEX( 13 ), \
- .eventCount = 2, \
+ .eventList = nullptr, \
+ .eventCount = 0, \
},\
{ \
/* Endpoint: 0, Cluster: WiFi Network Diagnostics (server) */ \
@@ -2231,7 +2203,7 @@
.functions = NULL, \
.acceptedCommandList = ZAP_GENERATED_COMMANDS_INDEX( 46 ) ,\
.generatedCommandList = nullptr ,\
- .eventList = ZAP_GENERATED_EVENTS_INDEX( 15 ), \
+ .eventList = ZAP_GENERATED_EVENTS_INDEX( 13 ), \
.eventCount = 3, \
},\
{ \
@@ -2465,8 +2437,8 @@
.functions = NULL, \
.acceptedCommandList = nullptr ,\
.generatedCommandList = nullptr ,\
- .eventList = ZAP_GENERATED_EVENTS_INDEX( 18 ), \
- .eventCount = 2, \
+ .eventList = nullptr, \
+ .eventCount = 0, \
},\
{ \
/* Endpoint: 1, Cluster: Power Source (server) */ \
@@ -2478,8 +2450,8 @@
.functions = NULL, \
.acceptedCommandList = nullptr ,\
.generatedCommandList = nullptr ,\
- .eventList = ZAP_GENERATED_EVENTS_INDEX( 20 ), \
- .eventCount = 1, \
+ .eventList = nullptr, \
+ .eventCount = 0, \
},\
{ \
/* Endpoint: 1, Cluster: Switch (server) */ \
@@ -2491,7 +2463,7 @@
.functions = NULL, \
.acceptedCommandList = nullptr ,\
.generatedCommandList = nullptr ,\
- .eventList = ZAP_GENERATED_EVENTS_INDEX( 21 ), \
+ .eventList = ZAP_GENERATED_EVENTS_INDEX( 16 ), \
.eventCount = 1, \
},\
{ \
@@ -2530,8 +2502,8 @@
.functions = NULL, \
.acceptedCommandList = nullptr ,\
.generatedCommandList = nullptr ,\
- .eventList = ZAP_GENERATED_EVENTS_INDEX( 22 ), \
- .eventCount = 1, \
+ .eventList = nullptr, \
+ .eventCount = 0, \
},\
{ \
/* Endpoint: 1, Cluster: Mode Select (server) */ \
@@ -2556,7 +2528,7 @@
.functions = chipFuncArrayDoorLockServer, \
.acceptedCommandList = ZAP_GENERATED_COMMANDS_INDEX( 127 ) ,\
.generatedCommandList = ZAP_GENERATED_COMMANDS_INDEX( 142 ) ,\
- .eventList = ZAP_GENERATED_EVENTS_INDEX( 23 ), \
+ .eventList = ZAP_GENERATED_EVENTS_INDEX( 17 ), \
.eventCount = 4, \
},\
{ \
@@ -2595,8 +2567,8 @@
.functions = chipFuncArrayPumpConfigurationAndControlServer, \
.acceptedCommandList = nullptr ,\
.generatedCommandList = nullptr ,\
- .eventList = ZAP_GENERATED_EVENTS_INDEX( 27 ), \
- .eventCount = 12, \
+ .eventList = nullptr, \
+ .eventCount = 0, \
},\
{ \
/* Endpoint: 1, Cluster: Thermostat (server) */ \
@@ -2907,7 +2879,7 @@
.functions = NULL, \
.acceptedCommandList = ZAP_GENERATED_COMMANDS_INDEX( 196 ) ,\
.generatedCommandList = ZAP_GENERATED_COMMANDS_INDEX( 215 ) ,\
- .eventList = ZAP_GENERATED_EVENTS_INDEX( 39 ), \
+ .eventList = ZAP_GENERATED_EVENTS_INDEX( 21 ), \
.eventCount = 2, \
},\
{ \