| # Copyright (c) 2023 Project CHIP Authors |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| |
| name: |
| 3.6 [TC-OTCCM-3.3] On Mode and Startup Mode functionality with DUT as Server |
| |
| PICS: |
| - OTCCM.S.A0002 |
| - OTCCM.S.A0003 |
| - MOD.S.F00 |
| - OO.S.A4003 |
| |
| config: |
| nodeId: 0x12344321 |
| cluster: "Oven Mode" |
| endpoint: 1 |
| |
| new_start_up_mode_th: |
| type: int8u |
| defaultValue: 0 |
| new_mode_th: |
| type: int8u |
| defaultValue: 1 |
| |
| tests: |
| - label: |
| "Step 1: Commission DUT to TH (can be skipped if done in a preceding |
| test)." |
| cluster: "DelayCommands" |
| command: "WaitForCommissionee" |
| arguments: |
| values: |
| - name: "nodeId" |
| value: nodeId |
| |
| - label: "Step 2: TH reads from the DUT the StartUpMode attribute." |
| PICS: OTCCM.S.A0002 |
| command: "readAttribute" |
| attribute: "StartUpMode" |
| response: |
| saveAs: startup_mode_dut |
| |
| - label: |
| "Step 2: If startup_mode_dut is null proceed to step 3. Else save |
| startup_mode_dut as new_start_up_mode_th and proceed to step 5." |
| PICS: OTCCM.S.A0002 |
| cluster: "EqualityCommands" |
| command: "UnsignedNumberEquals" |
| arguments: |
| values: |
| - name: "Value1" |
| value: startup_mode_dut |
| - name: "Value2" |
| value: null |
| response: |
| - values: |
| - name: "Equals" |
| saveAs: IsExpectedValue |
| |
| - label: "Step 3: TH reads from the DUT the SupportedModes attribute." |
| runIf: IsExpectedValue |
| PICS: OTCCM.S.A0000 |
| command: "readAttribute" |
| attribute: "SupportedModes" |
| response: |
| saveAs: supported_modes_dut |
| constraints: |
| type: list |
| minLength: 2 |
| |
| - label: |
| "Step 4: TH writes to the DUT the StartUpMode attribute with the |
| new_start_up_mode_th value" |
| PICS: OTCCM.S.A0002 |
| runIf: IsExpectedValue |
| command: "writeAttribute" |
| attribute: "StartUpMode" |
| arguments: |
| value: new_start_up_mode_th |
| |
| - label: "Step 5: TH reads from the DUT the OnMode attribute." |
| PICS: OTCCM.S.A0003 && OTCCM.S.A0002 |
| command: "readAttribute" |
| attribute: "OnMode" |
| response: |
| saveAs: old_on_mode_dut |
| |
| - label: |
| "Step 5: If startup_mode_dut is equal to old_on_mode_dut proceed to |
| step 6. Else proceed to step 8." |
| PICS: OTCCM.S.A0002 |
| cluster: "EqualityCommands" |
| command: "UnsignedNumberEquals" |
| arguments: |
| values: |
| - name: "Value1" |
| value: old_on_mode_dut |
| - name: "Value2" |
| value: startup_mode_dut |
| response: |
| - values: |
| - name: "Equals" |
| saveAs: Step5_IsExpectedValue |
| |
| - label: "Step 6: TH reads from the DUT the SupportedModes attribute." |
| PICS: OTCCM.S.A0000 && OTCCM.S.A0002 |
| runIf: Step5_IsExpectedValue |
| command: "readAttribute" |
| attribute: "SupportedModes" |
| response: |
| saveAs: Step6_supported_modes_dut |
| constraints: |
| type: list |
| minLength: 2 |
| |
| - label: |
| "Step 7: TH writes to the DUT the OnMode attribute with the |
| new_mode_th value" |
| PICS: OTCCM.S.A0003 |
| runIf: Step5_IsExpectedValue |
| command: "writeAttribute" |
| attribute: "OnMode" |
| arguments: |
| value: new_mode_th |
| |
| - label: "Step 8: TH reads from the DUT the OnMode attribute." |
| PICS: OTCCM.S.A0003 && MOD.S.F00 |
| command: "readAttribute" |
| attribute: "OnMode" |
| response: |
| saveAs: new_on_mode_dut |
| |
| - label: |
| "Step 9: TH writes to the DUT the StartUpOnOff attribute with the |
| value 1." |
| PICS: OO.S.A4003 |
| cluster: "On/Off" |
| command: "writeAttribute" |
| attribute: "StartUpOnOff" |
| arguments: |
| value: 1 |
| |
| - label: "Step 10: Physically power cycle the device" |
| verification: | |
| Physically power cycle the device. |
| cluster: "LogCommands" |
| command: "UserPrompt" |
| PICS: PICS_USER_PROMPT |
| arguments: |
| values: |
| - name: "message" |
| value: "Please enter 'y' for success" |
| - name: "expectedValue" |
| value: "y" |
| |
| - label: "Wait for the commissioned device to be retrieved" |
| cluster: "DelayCommands" |
| command: "WaitForCommissionee" |
| arguments: |
| values: |
| - name: "nodeId" |
| value: nodeId |
| |
| - label: "Step 11: TH reads from the DUT the StartUpMode attribute." |
| PICS: OTCCM.S.A0002 && PICS_USER_PROMPT |
| command: "readAttribute" |
| attribute: "StartUpMode" |
| response: |
| value: new_start_up_mode_th |
| |
| - label: "Step 12: TH reads from the DUT the CurrentMode attribute." |
| PICS: OTCCM.S.A0001 && PICS_USER_PROMPT |
| command: "readAttribute" |
| attribute: "CurrentMode" |
| response: |
| value: new_on_mode_dut |