| # Copyright (c) 2021 Project CHIP Authors |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| # Auto-generated scripts for harness use only, please review before automation. The endpoints and cluster names are currently set to default |
| |
| name: |
| 24.1.24. [TC-CADMIN-1.24] Open commissioning window - durations max and |
| max+1 [ECM] [DUT - Commissionee] |
| |
| PICS: |
| - CADMIN.S |
| |
| config: |
| nodeId: 0x12344321 |
| timeout: 330 |
| endpoint: 0 |
| discriminator: |
| type: int16u |
| defaultValue: 3840 |
| PakeVerifier: |
| type: octet_string |
| defaultValue: |
| "\xb9\x61\x70\xaa\xe8\x03\x34\x68\x84\x72\x4f\xe9\xa3\xb2\x87\xc3\x03\x30\xc2\xa6\x60\x37\x5d\x17\xbb\x20\x5a\x8c\xf1\xae\xcb\x35\x04\x57\xf8\xab\x79\xee\x25\x3a\xb6\xa8\xe4\x6b\xb0\x9e\x54\x3a\xe4\x22\x73\x6d\xe5\x01\xe3\xdb\x37\xd4\x41\xfe\x34\x49\x20\xd0\x95\x48\xe4\xc1\x82\x40\x63\x0c\x4f\xf4\x91\x3c\x53\x51\x38\x39\xb7\xc0\x7f\xcc\x06\x27\xa1\xb8\x57\x3a\x14\x9f\xcd\x1f\xa4\x66\xcf" |
| |
| tests: |
| - label: "Precondition: Reset Devices to factory defaults" |
| cluster: "SystemCommands" |
| PICS: PICS_SDK_CI_ONLY |
| command: "FactoryReset" |
| |
| - label: "Precondition: Reset Devices to factory defaults" |
| verification: | |
| Not implemented in YAML |
| cluster: "LogCommands" |
| command: "UserPrompt" |
| PICS: PICS_SKIP_SAMPLE_APP |
| arguments: |
| values: |
| - name: "message" |
| value: "Factory Reset the DUT and enter 'y' after success" |
| - name: "expectedValue" |
| value: "y" |
| |
| - label: "TH_CR1 starts a commissioning process with DUT_CE" |
| cluster: "DelayCommands" |
| command: "WaitForCommissionee" |
| PICS: CADMIN.S.C00.Rsp |
| arguments: |
| values: |
| - name: "nodeId" |
| value: nodeId |
| |
| - label: "TH_CR1 opens a commissioning window on DUT_CE" |
| cluster: "AdministratorCommissioning" |
| command: "OpenCommissioningWindow" |
| PICS: CADMIN.S.C00.Rsp |
| timedInteractionTimeoutMs: 10000 |
| arguments: |
| values: |
| - name: "CommissioningTimeout" |
| value: 180 |
| - name: "PAKEVerifier" |
| value: PakeVerifier |
| - name: "discriminator" |
| value: discriminator |
| - name: "iterations" |
| value: 1000 |
| - name: "salt" |
| value: "SPAKE2P Key Salt" |
| |
| - label: "Wait for commissioning Window to 301 seconds" |
| cluster: "DelayCommands" |
| command: "WaitForMs" |
| arguments: |
| values: |
| - name: "ms" |
| value: 181000 |
| |
| - label: |
| "TH_CR1 reads the window status to verify the DUT_CE window is closed" |
| cluster: "AdministratorCommissioning" |
| command: "readAttribute" |
| attribute: "WindowStatus" |
| PICS: CADMIN.S.A0000 |
| response: |
| value: 0 |
| |
| - label: "TH_CR1 opens a commissioning window on DUT_CE" |
| cluster: "AdministratorCommissioning" |
| command: "OpenCommissioningWindow" |
| PICS: CADMIN.S.C00.Rsp |
| timedInteractionTimeoutMs: 10000 |
| arguments: |
| values: |
| - name: "CommissioningTimeout" |
| value: 179 |
| - name: "PAKEVerifier" |
| value: PakeVerifier |
| - name: "discriminator" |
| value: discriminator |
| - name: "iterations" |
| value: 1000 |
| - name: "salt" |
| value: "SPAKE2P Key Salt" |
| response: |
| error: INVALID_COMMAND |
| |
| - label: |
| "TH_CR1 reads the window status to verify the DUT_CE window is closed" |
| cluster: "AdministratorCommissioning" |
| command: "readAttribute" |
| attribute: "WindowStatus" |
| PICS: CADMIN.S.A0000 |
| response: |
| value: 0 |