blob: 794fd7362998f4b92700a5814665f999a5f5b15d [file] [log] [blame]
# Copyright (c) 2021 Project CHIP Authors
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
# Auto-generated scripts for harness use only, please review before automation. The endpoints and cluster names are currently set to default
name:
24.1.24. [TC-CADMIN-1.24] Open commissioning window - durations max and
max+1 [ECM] [DUT - Commissionee]
PICS:
- CADMIN.S
config:
nodeId: 0x12344321
timeout: 200
endpoint: 0
discriminator:
type: int16u
defaultValue: 3840
PakeVerifier:
type: octet_string
defaultValue: "hex:b96170aae803346884724fe9a3b287c30330c2a660375d17bb205a8cf1aecb350457f8ab79ee253ab6a8e46bb09e543ae422736de501e3db37d441fe344920d09548e4c18240630c4ff4913c53513839b7c07fcc0627a1b8573a149fcd1fa466cf"
tests:
- label: "Precondition: Reset Devices to factory defaults"
cluster: "SystemCommands"
PICS: PICS_SDK_CI_ONLY
command: "FactoryReset"
- label: "Precondition: Reset Devices to factory defaults"
verification: |
Not implemented in YAML
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_SKIP_SAMPLE_APP
arguments:
values:
- name: "message"
value: "Factory Reset the DUT and enter 'y' after success"
- name: "expectedValue"
value: "y"
- label: "TH_CR1 starts a commissioning process with DUT_CE"
cluster: "DelayCommands"
command: "WaitForCommissionee"
PICS: CADMIN.S.C00.Rsp
arguments:
values:
- name: "nodeId"
value: nodeId
- label: "TH_CR1 opens a commissioning window on DUT_CE"
cluster: "AdministratorCommissioning"
command: "OpenCommissioningWindow"
PICS: CADMIN.S.C00.Rsp
timedInteractionTimeoutMs: 10000
arguments:
values:
- name: "CommissioningTimeout"
value: 180
- name: "PAKEVerifier"
value: PakeVerifier
- name: "discriminator"
value: discriminator
- name: "iterations"
value: 1000
- name: "salt"
value: "SPAKE2P Key Salt"
- label: "Wait for commissioning Window to 181 seconds"
cluster: "DelayCommands"
command: "WaitForMs"
arguments:
values:
- name: "ms"
value: 181000
- label:
"TH_CR1 reads the window status to verify the DUT_CE window is closed"
cluster: "AdministratorCommissioning"
command: "readAttribute"
attribute: "WindowStatus"
PICS: CADMIN.S.A0000
response:
value: 0
- label: "TH_CR1 opens a commissioning window on DUT_CE"
cluster: "AdministratorCommissioning"
command: "OpenCommissioningWindow"
PICS: CADMIN.S.C00.Rsp
timedInteractionTimeoutMs: 10000
arguments:
values:
- name: "CommissioningTimeout"
value: 179
- name: "PAKEVerifier"
value: PakeVerifier
- name: "discriminator"
value: discriminator
- name: "iterations"
value: 1000
- name: "salt"
value: "SPAKE2P Key Salt"
response:
error: INVALID_COMMAND
- label:
"TH_CR1 reads the window status to verify the DUT_CE window is closed"
cluster: "AdministratorCommissioning"
command: "readAttribute"
attribute: "WindowStatus"
PICS: CADMIN.S.A0000
response:
value: 0