name: 15.1.1. [TC-PCC-1.1] Global attributes with server as DUT
PICS:
- PCC.S
config:
nodeId: 0x12344321
cluster: "Pump Configuration and Control"
endpoint: 1
tests:
- label: "Wait for the commissioned device to be retrieved"
cluster: "DelayCommands"
command: "WaitForCommissionee"
arguments:
values:
- name: "nodeId"
value: nodeId
- label: "TH reads the ClusterRevision attribute from the DUT"
command: "readAttribute"
attribute: "ClusterRevision"
response:
value: 3
constraints:
type: int16u
- label: "TH reads the FeatureMap attribute from the DUT"
command: "readAttribute"
attribute: "FeatureMap"
response:
value: 0
constraints:
type: bitmap32
- label: "TH reads the AttributeList attribute from the DUT"
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains:
[0, 1, 2, 17, 18, 19, 32, 65528, 65529, 65531, 65532, 65533]
- label:
"TH reads optional attribute(MinConstPressure) attribute in
AttributeList from the DUT"
PICS: PCC.S.A0003
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [3]
- label:
"TH reads optional attribute(MaxConstPressure) attribute in
AttributeList from the DUT"
PICS: PCC.S.A0004
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [4]
- label:
"TH reads optional attribute(MinCompPressure) attribute in
AttributeList from the DUT"
PICS: PCC.S.A0005
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [5]
- label:
"TH reads optional attribute(MaxCompPressure) attribute in
AttributeList from the DUT"
PICS: PCC.S.A0006
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [6]
- label:
"TH reads optional attribute(MinConstSpeed) attribute in AttributeList
from the DUT"
PICS: PCC.S.A0007
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [7]
- label:
"TH reads optional attribute(MaxConstSpeed) attribute in AttributeList
from the DUT"
PICS: PCC.S.A0008
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [8]
- label:
"TH reads optional attribute(MinConstFlow) attribute in AttributeList
from the DUT"
PICS: PCC.S.A0009
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [9]
- label:
"TH reads optional attribute(MaxConstFlow) attribute in AttributeList
from the DUT"
PICS: PCC.S.A000a
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [10]
- label:
"TH reads optional attribute(MinConstTemp) attribute in AttributeList
from the DUT"
PICS: PCC.S.A000b
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [11]
- label:
"TH reads optional attribute(MaxConstTemp) attribute in AttributeList
from the DUT"
PICS: PCC.S.A000c
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [12]
- label:
"TH reads optional attribute(PumpStatus) attribute in AttributeList
from the DUT"
PICS: PCC.S.A0010
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [16]
- label:
"TH reads optional attribute(Speed) attribute in AttributeList from
the DUT"
PICS: PCC.S.A0014
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [20]
- label:
"TH reads optional attribute(LifetimeRunningHours) attribute in
AttributeList from the DUT"
PICS: PCC.S.A0015
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [21]
- label:
"TH reads optional attribute(Power) attribute in AttributeList from
the DUT"
PICS: PCC.S.A0016
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [22]
- label:
"TH reads optional attribute(LifetimeEnergyConsumed) attribute in
AttributeList from the DUT"
PICS: PCC.S.A0017
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [23]
- label:
"TH reads optional attribute(ControlMode) attribute in AttributeList
from the DUT"
PICS: PCC.S.A0021
command: "readAttribute"
attribute: "AttributeList"
response:
constraints:
type: list
contains: [33]
- label: "TH reads the AcceptedCommandList attribute from the DUT"
command: "readAttribute"
attribute: "AcceptedCommandList"
response:
value: []
constraints:
type: list
- label: "TH reads the GeneratedCommandList attribute from the DUT"
command: "readAttribute"
attribute: "GeneratedCommandList"
response:
value: []
constraints:
type: list
#Commenting out the step EventList attribute which is out of scope for matter V1.0
#- label:
# "Read EventList attribute from the DUT and Verify that the DUT
# response provides a list of supported events."
# verification: |
# Not implemented in chip-tool
# cluster: "LogCommands"
# command: "UserPrompt"
# PICS: PICS_USER_PROMPT
# arguments:
# values:
# - name: "message"
# value: "Please enter 'y' for success"
# - name: "expectedValue"
# value: "y"