name: 15.2.1. [TC-PCC-2.1] Attributes with server as DUT
PICS:
- PCC.S
config:
nodeId: 0x12344321
cluster: "Pump Configuration and Control"
endpoint: 1
tests:
- label: "Wait for the commissioned device to be retrieved"
cluster: "DelayCommands"
command: "WaitForCommissionee"
arguments:
values:
- name: "nodeId"
value: nodeId
- label: "Read the mandatory attribute: MaxPressure"
PICS: PCC.S.A0000
command: "readAttribute"
attribute: "MaxPressure"
response:
constraints:
type: int16s
minValue: -32768
maxValue: 32767
- label: "Read the mandatory attribute: MaxSpeed"
PICS: PCC.S.A0001
command: "readAttribute"
attribute: "MaxSpeed"
response:
constraints:
type: int16u
minValue: 0
maxValue: 65535
- label: "Read the mandatory attribute: MaxFlow"
PICS: PCC.S.A0002
command: "readAttribute"
attribute: "MaxFlow"
response:
constraints:
type: int16u
minValue: 0
maxValue: 65535
- label: "Read the optional attribute: MinConstPressure"
PICS: PCC.S.A0003
command: "readAttribute"
attribute: "MinConstPressure"
response:
constraints:
type: int16s
minValue: -32768
maxValue: 32767
- label: "Read the optional attribute: MaxConstPressure"
PICS: PCC.S.A0004
command: "readAttribute"
attribute: "MaxConstPressure"
response:
constraints:
type: int16s
minValue: -32768
maxValue: 32767
- label: "Read the optional attribute: MinCompPressure"
PICS: PCC.S.A0005
command: "readAttribute"
attribute: "MinCompPressure"
response:
constraints:
type: int16s
minValue: -32768
maxValue: 32767
- label: "Read the optional attribute: MaxCompPressure"
PICS: PCC.S.A0006
command: "readAttribute"
attribute: "MaxCompPressure"
response:
constraints:
type: int16s
minValue: -32768
maxValue: 32767
- label: "Read the optional attribute: MinConstSpeed"
PICS: PCC.S.A0007
command: "readAttribute"
attribute: "MinConstSpeed"
response:
constraints:
type: int16u
minValue: 0
maxValue: 65535
- label: "Read the optional attribute: MaxConstSpeed"
PICS: PCC.S.A0008
command: "readAttribute"
attribute: "MaxConstSpeed"
response:
constraints:
type: int16u
minValue: 0
maxValue: 65535
- label: "Read the optional attribute: MinConstFlow"
PICS: PCC.S.A0009
command: "readAttribute"
attribute: "MinConstFlow"
response:
constraints:
type: int16u
minValue: 0
maxValue: 65535
- label: "Read the optional attribute: MaxConstFlow"
PICS: PCC.S.A000a
command: "readAttribute"
attribute: "MaxConstFlow"
response:
constraints:
type: int16u
minValue: 0
maxValue: 65535
- label: "Read the optional attribute: MinConstTemp"
PICS: PCC.S.A000b
command: "readAttribute"
attribute: "MinConstTemp"
response:
constraints:
type: int16s
minValue: -32768
maxValue: 32767
- label: "Read the optional attribute: MaxConstTemp"
PICS: PCC.S.A000c
command: "readAttribute"
attribute: "MaxConstTemp"
response:
constraints:
type: int16s
minValue: -32768
maxValue: 32767
- label: "Read the optional attribute: PumpStatus"
PICS: PCC.S.A0010
command: "readAttribute"
attribute: "PumpStatus"
response:
constraints:
type: bitmap16
minValue: 0
maxValue: 8
- label: "Read attribute: EffectiveOperationMode"
PICS: PCC.S.A0011
command: "readAttribute"
attribute: "EffectiveOperationMode"
response:
constraints:
type: enum8
minValue: 0
maxValue: 3
- label: "Read attribute: EffectiveControlMode"
PICS: PCC.S.A0012
command: "readAttribute"
attribute: "EffectiveControlMode"
response:
constraints:
type: enum8
minValue: 0
maxValue: 7
- label: "Read attribute: Capacity"
PICS: PCC.S.A0013
command: "readAttribute"
attribute: "Capacity"
response:
constraints:
type: int16s
minValue: -32768
maxValue: 32767
- label: "Read the optional attribute: Speed"
PICS: PCC.S.A0014
command: "readAttribute"
attribute: "Speed"
response:
constraints:
type: int16u
minValue: 0
maxValue: 65535
- label: "Read the optional attribute: LifetimeRunningHours"
PICS: PCC.S.A0015
command: "readAttribute"
attribute: "LifetimeRunningHours"
response:
constraints:
type: int24u
minValue: 0
maxValue: 16777215
- label: "Read the optional attribute: Power"
PICS: PCC.S.A0016
command: "readAttribute"
attribute: "Power"
response:
constraints:
type: int24u
minValue: 0
maxValue: 16777215
- label: "Read the optional attribute: LifetimeEnergyConsumed"
PICS: PCC.S.A0017
command: "readAttribute"
attribute: "LifetimeEnergyConsumed"
response:
constraints:
type: int32u
minValue: 0
maxValue: 4294967295
- label: "Read optional attribute: OperationMode"
PICS: PCC.S.A0020
command: "readAttribute"
attribute: "OperationMode"
response:
constraints:
type: enum8
minValue: 0
maxValue: 3
- label: "Read optional attribute: ControlMode"
PICS: PCC.S.A0021
command: "readAttribute"
attribute: "ControlMode"
response:
constraints:
type: enum8
minValue: 0
maxValue: 7