| name: |
| 24.1.24. [TC-CADMIN-1.24] Open commissioning window - durations max and |
| max+1 [ECM] [DUT - Commissionee] |
| |
| PICS: |
| - CADMIN.S |
| |
| config: |
| nodeId: 0x12344321 |
| timeout: 200 |
| endpoint: 0 |
| payload: |
| type: char_string |
| defaultValue: "MT:-24J0AFN00KA0648G00" |
| discriminator: |
| type: int16u |
| defaultValue: 3840 |
| PakeVerifier: |
| type: octet_string |
| defaultValue: "hex:b96170aae803346884724fe9a3b287c30330c2a660375d17bb205a8cf1aecb350457f8ab79ee253ab6a8e46bb09e543ae422736de501e3db37d441fe344920d09548e4c18240630c4ff4913c53513839b7c07fcc0627a1b8573a149fcd1fa466cf" |
| |
| tests: |
| - label: "Precondition: Reset Devices to factory defaults" |
| cluster: "SystemCommands" |
| PICS: PICS_SDK_CI_ONLY |
| command: "FactoryReset" |
| |
| - label: "Precondition: Reset Devices to factory defaults" |
| verification: | |
| Reset Devices to factory defaults |
| cluster: "LogCommands" |
| command: "UserPrompt" |
| PICS: PICS_SKIP_SAMPLE_APP |
| arguments: |
| values: |
| - name: "message" |
| value: "Factory Reset the DUT and enter 'y' after success" |
| - name: "expectedValue" |
| value: "y" |
| |
| - label: "Step 1: TH_CR1 starts a commissioning process with DUT_CE" |
| cluster: "CommissionerCommands" |
| command: "PairWithCode" |
| PICS: CADMIN.S |
| arguments: |
| values: |
| - name: "nodeId" |
| value: nodeId |
| - name: "payload" |
| value: payload |
| |
| - label: "Step 1: TH_CR1 commissioned with DUT_CE" |
| cluster: "DelayCommands" |
| command: "WaitForCommissionee" |
| PICS: CADMIN.S.C00.Rsp |
| arguments: |
| values: |
| - name: "nodeId" |
| value: nodeId |
| |
| - label: |
| "Step 2: TH_CR1 opens a commissioning window on DUT_CE using ECM with |
| a value of 180 seconds" |
| verification: | |
| On TH_CR1 ( chip tool), open commissioning window |
| |
| ./chip-tool pairing open-commissioning-window 1 1 180 1000 3840 |
| |
| Verify Manual pairing code on TH_CR1(chip-tool) Log |
| |
| [1635925713.966786][9695:9700] CHIP:SC: Success status report received. Session was established |
| [1635925713.966839][9695:9700] CHIP:IN: New secure session created for device 0x0000000000000001, key 33!! |
| [1635925713.966938][9695:9700] CHIP:CTL: OpenCommissioningWindow for device ID 1 |
| [1635925713.972601][9695:9700] CHIP:DMG: ICR moving to [AddingComm] |
| [1635925713.972705][9695:9700] CHIP:DMG: ICR moving to [AddedComma] |
| [1635925713.972815][9695:9700] CHIP:IN: Prepared encrypted message 0xaaaad9b57d10 to 0x0000000000000001 of type 0x8 and protocolId (0, 1) on exchange 31056i with MessageCounter:0. |
| [1635925713.972876][9695:9700] CHIP:IN: Sending encrypted msg 0xaaaad9b57d10 with MessageCounter:0 to 0x0000000000000001 at monotonic time: 13449459 msec |
| [1635925713.973006][9695:9700] CHIP:DMG: ICR moving to [CommandSen] |
| [1635925713.973061][9695:9700] CHIP:CTL: Manual pairing code: [35484132896] |
| [1635925713.973120][9695:9700] CHIP:CTL: SetupQRCode: [MT:00000CQM00A7F87ZT10] |
| [1635925713.973178][9695:9700] CHIP:EM: Sending Standalone Ack for MessageCounter:1964916542 on exchange 31055i |
| cluster: "LogCommands" |
| command: "UserPrompt" |
| PICS: PICS_SKIP_SAMPLE_APP && CADMIN.S.C00.Rsp |
| arguments: |
| values: |
| - name: "message" |
| value: "Enter 'y' after success" |
| - name: "expectedValue" |
| value: "y" |
| |
| - label: |
| "Step 2a: TH_CR1 opens a commissioning window on DUT_CE using ECM with |
| a value of 180 seconds" |
| cluster: "Administrator Commissioning" |
| command: "OpenCommissioningWindow" |
| PICS: CADMIN.S.C00.Rsp && PICS_SDK_CI_ONLY |
| timedInteractionTimeoutMs: 10000 |
| arguments: |
| values: |
| - name: "CommissioningTimeout" |
| value: 180 |
| - name: "PAKEPasscodeVerifier" |
| value: PakeVerifier |
| - name: "Discriminator" |
| value: discriminator |
| - name: "Iterations" |
| value: 1000 |
| - name: "Salt" |
| value: "SPAKE2P Key Salt" |
| |
| - label: "Step 3: Wait for commissioning Window to 181 seconds" |
| PICS: CADMIN.S.C00.Rsp |
| cluster: "DelayCommands" |
| command: "WaitForMs" |
| arguments: |
| values: |
| - name: "ms" |
| value: 181000 |
| |
| - label: |
| "Step 4: TH_CR1 reads the window status to verify the DUT_CE window is |
| closed" |
| cluster: "Administrator Commissioning" |
| command: "readAttribute" |
| attribute: "WindowStatus" |
| PICS: CADMIN.S.A0000 |
| response: |
| value: 0 |
| |
| - label: |
| "Step 5: TH_CR1 opens a commissioning window on DUT_CE using ECM with |
| a value of 179 seconds" |
| verification: | |
| On TH_CR1 ( chip tool), open commissioning window |
| |
| ./chip-tool pairing open-commissioning-window 1 1 179 2000 3841 |
| |
| Verify DUT_CE responds General error 0x85 on TH_CR1 (chip-tool) log |
| |
| CHIP:DMG: Received Command Response Status for Endpoint=0 Cluster=0x0000_003C Command=0x0000_0001 Status=0x85 |
| [1652860801.225084][9512:9517] CHIP:TOO: Error: IM Error 0x00000585: General error: 0x85 (INVALID_COMMAND) |
| [1652860801.225173][9512:9517] CHIP:DMG: ICR moving to [AwaitingDe] |
| [1652860801.225294][9512:9517] CHIP:EM: Sending Standalone Ack for MessageCounter:4191961 on exchange 37827i |
| cluster: "LogCommands" |
| command: "UserPrompt" |
| PICS: PICS_SKIP_SAMPLE_APP && CADMIN.S.C00.Rsp |
| arguments: |
| values: |
| - name: "message" |
| value: "Enter 'y' after success" |
| - name: "expectedValue" |
| value: "y" |
| |
| - label: |
| "Step 5a: TH_CR1 opens a commissioning window on DUT_CE using ECM with |
| a value of 179 seconds" |
| cluster: "Administrator Commissioning" |
| command: "OpenCommissioningWindow" |
| PICS: CADMIN.S.C00.Rsp && PICS_SDK_CI_ONLY |
| timedInteractionTimeoutMs: 10000 |
| arguments: |
| values: |
| - name: "CommissioningTimeout" |
| value: 179 |
| - name: "PAKEPasscodeVerifier" |
| value: PakeVerifier |
| - name: "Discriminator" |
| value: discriminator |
| - name: "Iterations" |
| value: 1000 |
| - name: "Salt" |
| value: "SPAKE2P Key Salt" |
| response: |
| error: INVALID_COMMAND |
| |
| - label: |
| "Step 6: TH_CR1 reads the window status to verify the DUT_CE window is |
| closed" |
| cluster: "Administrator Commissioning" |
| command: "readAttribute" |
| attribute: "WindowStatus" |
| PICS: CADMIN.S.A0000 |
| response: |
| value: 0 |