| name: 3.2.1. [TC-DRYERCTRL-2.1] Optional Dryness attributes with server as DUT |
| |
| PICS: |
| - DRYERCTRL.S |
| |
| config: |
| nodeId: 0x12344321 |
| cluster: "Laundry Dryer Controls" |
| endpoint: 1 |
| |
| unsupportedSelectedDrynessLevel: |
| type: int8u |
| defaultValue: 4 |
| |
| SupportedDrynessLevel: |
| type: int8u |
| defaultValue: 1 |
| |
| tests: |
| - label: "Step 1: Wait for the commissioned device to be retrieved" |
| cluster: "DelayCommands" |
| command: "WaitForCommissionee" |
| arguments: |
| values: |
| - name: "nodeId" |
| value: nodeId |
| |
| - label: |
| "Step 2: TH reads from the DUT the mandatory attribute: |
| SupportedDrynessLevels" |
| PICS: DRYERCTRL.S.A0000 |
| command: "readAttribute" |
| attribute: "SupportedDrynessLevels" |
| response: |
| constraints: |
| type: list |
| maxLength: 4 |
| |
| - label: |
| "Step 3: TH reads from the DUT the mandatory attribute: |
| SelectedDrynessLevel" |
| PICS: DRYERCTRL.S.A0001 |
| command: "readAttribute" |
| attribute: "SelectedDrynessLevel" |
| response: |
| constraints: |
| type: enum8 |
| minValue: 0 |
| maxValue: 3 |
| |
| - label: |
| "Step 4:TH writes a supported SelectedDrynessLevel attribute that is |
| within the list of SupportedDrynessLevels" |
| PICS: DRYERCTRL.S.A0001 |
| command: "writeAttribute" |
| attribute: "SelectedDrynessLevel" |
| arguments: |
| value: SupportedDrynessLevel |
| |
| - label: "Wait 2 seconds" |
| cluster: "DelayCommands" |
| command: "WaitForMs" |
| arguments: |
| values: |
| - name: "ms" |
| value: 2000 |
| |
| - label: |
| "Step 5: after a few seconds, TH reads from the DUT the |
| SelectedDrynessLevel attribute" |
| PICS: DRYERCTRL.S.A0001 |
| command: "readAttribute" |
| attribute: "SelectedDrynessLevel" |
| response: |
| value: SupportedDrynessLevel |
| constraints: |
| type: enum8 |
| |
| - label: |
| "Step 6: TH writes an unsupported SelectedDrynessLevel attribute that |
| is not in list of SupportedDrynessLevels to DUT" |
| PICS: DRYERCTRL.S.A0001 |
| command: "writeAttribute" |
| attribute: "SelectedDrynessLevel" |
| arguments: |
| value: unsupportedSelectedDrynessLevel |
| response: |
| error: CONSTRAINT_ERROR |
| |
| - label: "Step 6: Operate device to set the condition to read only" |
| verification: | |
| Manual operation required |
| cluster: "LogCommands" |
| command: "UserPrompt" |
| PICS: PICS_SKIP_SAMPLE_APP && DRYERCTRL.S.M.ManuallyControlled |
| arguments: |
| values: |
| - name: "message" |
| value: "Please enter 'y' for success" |
| - name: "expectedValue" |
| value: "y" |
| |
| - label: |
| "Step 7: TH writes a supported SelectedDrynessLevel attribute to DUT |
| while DUT is not in a valid state." |
| PICS: DRYERCTRL.S.M.ManuallyControlled && DRYERCTRL.S.A0001 |
| command: "writeAttribute" |
| attribute: "SelectedDrynessLevel" |
| arguments: |
| value: SupportedDrynessLevel |
| response: |
| error: INVALID_IN_STATE |