| # Copyright (c) 2021 Project CHIP Authors |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| |
| name: 15.2.1. [TC-PCC-2.1] Attributes with server as DUT |
| |
| PICS: |
| - PCC.S |
| |
| config: |
| nodeId: 0x12344321 |
| cluster: "Pump Configuration and Control" |
| endpoint: 1 |
| |
| tests: |
| - label: |
| "Step 1: Commission DUT to TH (can be skipped if done in a preceding |
| test)." |
| cluster: "DelayCommands" |
| command: "WaitForCommissionee" |
| arguments: |
| values: |
| - name: "nodeId" |
| value: nodeId |
| |
| - label: "Step 2: TH reads from the DUT the MaxPressure attribute." |
| PICS: PCC.S.A0000 |
| command: "readAttribute" |
| attribute: "MaxPressure" |
| response: |
| constraints: |
| type: int16s |
| minValue: -32768 |
| maxValue: 32767 |
| |
| - label: "Step 3: TH reads from the DUT the MaxSpeed attribute." |
| PICS: PCC.S.A0001 |
| command: "readAttribute" |
| attribute: "MaxSpeed" |
| response: |
| constraints: |
| type: int16u |
| minValue: 0 |
| maxValue: 65535 |
| |
| - label: "Step 4: TH reads from the DUT the MaxFlow attribute." |
| PICS: PCC.S.A0002 |
| command: "readAttribute" |
| attribute: "MaxFlow" |
| response: |
| constraints: |
| type: int16u |
| minValue: 0 |
| maxValue: 65535 |
| |
| - label: "Step 5: TH reads from the DUT the MinConstPressure attribute." |
| PICS: PCC.S.A0003 |
| command: "readAttribute" |
| attribute: "MinConstPressure" |
| response: |
| constraints: |
| type: int16s |
| minValue: -32768 |
| maxValue: 32767 |
| |
| - label: "Step 6: TH reads from the DUT the MaxConstPressure attribute." |
| PICS: PCC.S.A0004 |
| command: "readAttribute" |
| attribute: "MaxConstPressure" |
| response: |
| constraints: |
| type: int16s |
| minValue: -32768 |
| maxValue: 32767 |
| |
| - label: "Step 7: TH reads from the DUT the MinCompPressure attribute." |
| PICS: PCC.S.A0005 |
| command: "readAttribute" |
| attribute: "MinCompPressure" |
| response: |
| constraints: |
| type: int16s |
| minValue: -32768 |
| maxValue: 32767 |
| |
| - label: "Step 8: TH reads from the DUT the MaxCompPressure attribute." |
| PICS: PCC.S.A0006 |
| command: "readAttribute" |
| attribute: "MaxCompPressure" |
| response: |
| constraints: |
| type: int16s |
| minValue: -32768 |
| maxValue: 32767 |
| |
| - label: "Step 9: TH reads from the DUT the MinConstSpeed attribute." |
| PICS: PCC.S.A0007 |
| command: "readAttribute" |
| attribute: "MinConstSpeed" |
| response: |
| constraints: |
| type: int16u |
| minValue: 0 |
| maxValue: 65535 |
| |
| - label: "Step 10: TH reads from the DUT the MaxConstSpeed attribute." |
| PICS: PCC.S.A0008 |
| command: "readAttribute" |
| attribute: "MaxConstSpeed" |
| response: |
| constraints: |
| type: int16u |
| minValue: 0 |
| maxValue: 65535 |
| |
| - label: "Step 11: TH reads from the DUT the MinConstFlow attribute." |
| PICS: PCC.S.A0009 |
| command: "readAttribute" |
| attribute: "MinConstFlow" |
| response: |
| constraints: |
| type: int16u |
| minValue: 0 |
| maxValue: 65535 |
| |
| - label: "Step 12: TH reads from the DUT the MaxConstFlow attribute." |
| PICS: PCC.S.A000a |
| command: "readAttribute" |
| attribute: "MaxConstFlow" |
| response: |
| constraints: |
| type: int16u |
| minValue: 0 |
| maxValue: 65535 |
| |
| - label: "Step 13: TH reads from the DUT the MinConstTemp attribute." |
| PICS: PCC.S.A000b |
| command: "readAttribute" |
| attribute: "MinConstTemp" |
| response: |
| constraints: |
| type: int16s |
| minValue: -32768 |
| maxValue: 32767 |
| |
| - label: "Step 14: TH reads from the DUT the MaxConstTemp attribute." |
| PICS: PCC.S.A000c |
| command: "readAttribute" |
| attribute: "MaxConstTemp" |
| response: |
| constraints: |
| type: int16s |
| minValue: -32768 |
| maxValue: 32767 |
| |
| - label: "Step 15: TH reads from the DUT the PumpStatus attribute." |
| PICS: PCC.S.A0010 |
| command: "readAttribute" |
| attribute: "PumpStatus" |
| response: |
| constraints: |
| type: bitmap16 |
| minValue: 0 |
| maxValue: 8 |
| |
| - label: |
| "Step 16: TH reads from the DUT the EffectiveOperationMode attribute." |
| PICS: PCC.S.A0011 |
| command: "readAttribute" |
| attribute: "EffectiveOperationMode" |
| response: |
| constraints: |
| type: enum8 |
| minValue: 0 |
| maxValue: 3 |
| |
| - label: |
| "Step 17: TH reads from the DUT the EffectiveControlMode attribute." |
| PICS: PCC.S.A0012 |
| command: "readAttribute" |
| attribute: "EffectiveControlMode" |
| response: |
| constraints: |
| type: enum8 |
| minValue: 0 |
| maxValue: 7 |
| |
| - label: "Step 18: TH reads from the DUT the Capacity attribute." |
| PICS: PCC.S.A0013 |
| command: "readAttribute" |
| attribute: "Capacity" |
| response: |
| constraints: |
| type: int16s |
| minValue: -32768 |
| maxValue: 32767 |
| |
| - label: "Step 19: TH reads from the DUT the Speed attribute." |
| PICS: PCC.S.A0014 |
| command: "readAttribute" |
| attribute: "Speed" |
| response: |
| constraints: |
| type: int16u |
| minValue: 0 |
| maxValue: 65535 |
| |
| - label: |
| "Step 20: TH reads from the DUT the LifetimeRunningHours attribute." |
| PICS: PCC.S.A0015 |
| command: "readAttribute" |
| attribute: "LifetimeRunningHours" |
| response: |
| constraints: |
| type: int24u |
| minValue: 0 |
| maxValue: 16777215 |
| |
| - label: "Step 21: TH reads from the DUT the Power attribute." |
| PICS: PCC.S.A0016 |
| command: "readAttribute" |
| attribute: "Power" |
| response: |
| constraints: |
| type: int24u |
| minValue: 0 |
| maxValue: 16777215 |
| |
| - label: |
| "Step 22: TH reads from the DUT the LifetimeEnergyConsumed attribute." |
| PICS: PCC.S.A0017 |
| command: "readAttribute" |
| attribute: "LifetimeEnergyConsumed" |
| response: |
| constraints: |
| type: int32u |
| minValue: 0 |
| maxValue: 4294967295 |
| |
| - label: "Step 23: TH reads from the DUT the OperationMode attribute." |
| PICS: PCC.S.A0020 |
| command: "readAttribute" |
| attribute: "OperationMode" |
| response: |
| constraints: |
| type: enum8 |
| minValue: 0 |
| maxValue: 3 |
| |
| - label: "Step 24: TH reads from the DUT the ControlMode attribute." |
| PICS: PCC.S.A0021 |
| command: "readAttribute" |
| attribute: "ControlMode" |
| response: |
| constraints: |
| type: enum8 |
| minValue: 0 |
| maxValue: 7 |