| name: 15.2.3. [TC-PCC-2.3] Primary functionality with server as DUT |
| |
| PICS: |
| - PCC.S |
| |
| config: |
| nodeId: 0x12344321 |
| cluster: "Pump Configuration and Control" |
| endpoint: 1 |
| |
| tests: |
| - label: "Wait for the commissioned device to be retrieved" |
| cluster: "DelayCommands" |
| command: "WaitForCommissionee" |
| arguments: |
| values: |
| - name: "nodeId" |
| value: nodeId |
| |
| - label: "Write 0 to the OperationMode attribute to DUT" |
| command: "writeAttribute" |
| attribute: "OperationMode" |
| PICS: PCC.S.A0020 |
| arguments: |
| value: 0 |
| |
| - label: "Reads the attribute: EffectiveOperationMode" |
| command: "readAttribute" |
| attribute: "EffectiveOperationMode" |
| PICS: PCC.S.A0011 |
| response: |
| value: 0 |
| |
| - label: "Write 0 to the ControlMode attribute to DUT" |
| command: "writeAttribute" |
| attribute: "ControlMode" |
| PICS: PCC.S.A0021 && PCC.M.ControlModeConstSpeed |
| arguments: |
| value: 0 |
| |
| - label: "Reads the attribute: EffectiveControlMode" |
| command: "readAttribute" |
| attribute: "EffectiveControlMode" |
| PICS: PCC.S.A0012 && PCC.M.ControlModeConstSpeed |
| response: |
| value: 0 |
| |
| - label: "Write 1 to the ControlMode attribute to DUT" |
| command: "writeAttribute" |
| attribute: "ControlMode" |
| PICS: PCC.S.A0021 && PCC.M.ControlModeConstPressure |
| arguments: |
| value: 1 |
| |
| - label: "Reads the attribute: EffectiveControlMode" |
| command: "readAttribute" |
| attribute: "EffectiveControlMode" |
| PICS: PCC.S.A0012 && PCC.M.ControlModeConstPressure |
| response: |
| value: 1 |
| |
| - label: "Write 2 to the ControlMode attribute to DUT" |
| command: "writeAttribute" |
| attribute: "ControlMode" |
| PICS: PCC.S.A0021 && PCC.M.ControlModeCompPressure |
| arguments: |
| value: 2 |
| |
| - label: "Reads the attribute: EffectiveControlMode" |
| command: "readAttribute" |
| attribute: "EffectiveControlMode" |
| PICS: PCC.S.A0012 && PCC.M.ControlModeCompPressure |
| response: |
| value: 2 |
| |
| - label: "Write 3 to the ControlMode attribute to DUT" |
| command: "writeAttribute" |
| attribute: "ControlMode" |
| PICS: PCC.S.A0021 && PCC.M.ControlModeConstFlow |
| arguments: |
| value: 3 |
| |
| - label: "Reads the attribute: EffectiveControlMode" |
| command: "readAttribute" |
| attribute: "EffectiveControlMode" |
| PICS: PCC.S.A0012 && PCC.M.ControlModeConstFlow |
| response: |
| value: 3 |
| |
| - label: "Write 5 to the ControlMode attribute to DUT" |
| command: "writeAttribute" |
| attribute: "ControlMode" |
| PICS: PCC.S.A0021 && PCC.M.ControlModeConstTemp |
| arguments: |
| value: 5 |
| |
| - label: "Reads the attribute: EffectiveControlMode" |
| command: "readAttribute" |
| attribute: "EffectiveControlMode" |
| PICS: PCC.S.A0012 && PCC.M.ControlModeConstTemp |
| response: |
| value: 5 |
| |
| - label: "Write 7 to the ControlMode attribute to DUT" |
| command: "writeAttribute" |
| attribute: "ControlMode" |
| PICS: PCC.S.A0021 && PCC.M.ControlModeAuto |
| arguments: |
| value: 7 |
| |
| - label: "Reads the attribute: EffectiveControlMode" |
| command: "readAttribute" |
| attribute: "EffectiveControlMode" |
| PICS: PCC.S.A0012 && PCC.M.ControlModeAuto |
| response: |
| value: 7 |