| #pragma once |
| |
| #include <app-common/zap-generated/cluster-objects.h> |
| #include <app/clusters/water-heater-management-server/water-heater-management-server.h> |
| |
| #include <protocols/interaction_model/StatusCode.h> |
| |
| namespace chip { |
| namespace app { |
| namespace Clusters { |
| namespace WaterHeaterManagement { |
| |
| class WhmManufacturer; |
| |
| enum HeatingOp |
| { |
| TurnHeatingOn, |
| TurnHeatingOff, |
| LeaveHeatingUnchanged |
| }; |
| |
| // This is an application level delegate to handle operational state commands according to the specific business logic. |
| class WaterHeaterManagementDelegate : public WaterHeaterManagement::Delegate |
| { |
| public: |
| WaterHeaterManagementDelegate(EndpointId clustersEndpoint); |
| |
| virtual ~WaterHeaterManagementDelegate() = default; |
| |
| void SetWaterHeaterManagementInstance(WaterHeaterManagement::Instance & instance); |
| |
| void SetWhmManufacturer(WhmManufacturer & whmManufacturer); |
| |
| /********************************************************************************* |
| * |
| * Methods implementing the WaterHeaterManagement::Delegate interface |
| * |
| *********************************************************************************/ |
| |
| /** |
| * @brief Delegate should implement a handler to start boosting the water |
| * temperature as required. Upon receipt, the Water Heater SHALL |
| * transition into the BOOST state, which SHALL cause the water in |
| * the tank (or the TargetPercentage of the water, if included) to be |
| * heated towards the set point (or the TemporarySetpoint, if |
| * included), which in turn may cause a call for heat, even if the |
| * mode is OFF, or is TIMED and it is during one of the Off periods. |
| * |
| * @param duration Indicates the time period in seconds for which |
| * the BOOST state is activated before it |
| * automatically reverts to the previous mode |
| * (e.g. OFF, MANUAL or TIMED). |
| * |
| * @param oneShot Indicates whether the BOOST state should be |
| * automatically canceled once the hot water has |
| * first reached the set point temperature (or the |
| * TemporarySetpoint temperature, if specified) |
| * for the TargetPercentage (if specified). |
| * |
| * @param emergencyBoost Indicates that the consumer wants the water to |
| * be heated as quickly as practicable. This MAY |
| * cause multiple heat sources to be activated |
| * (e.g. a heat pump and direct electric heating |
| * element). |
| * |
| * @param temporarySetpoint Indicates the target temperature to which to |
| * heat the hot water for this Boost command. It |
| * SHALL be used instead of the normal set point |
| * temperature whilst the BOOST state is active. |
| * |
| * @param targetPercentage If the tank supports the TankPercent feature, |
| * this field indicates the amount of water that |
| * SHALL be heated by this Boost command before |
| * the heater is switched off. |
| * |
| * @param targetReheat If the tank supports the TankPercent feature, |
| * and the heating by this Boost command has |
| * ceased because the TargetPercentage of the |
| * water in the tank has been heated to the set |
| * point (or TemporarySetpoint if included), this |
| * field indicates the percentage to which the hot |
| * water in the tank SHALL be allowed to fall |
| * before again beginning to reheat it. |
| * |
| * @return Success if the boost command is accepted; otherwise the command |
| * SHALL be rejected with appropriate error. |
| */ |
| Protocols::InteractionModel::Status HandleBoost(uint32_t duration, Optional<bool> oneShot, Optional<bool> emergencyBoost, |
| Optional<int16_t> temporarySetpoint, Optional<Percent> targetPercentage, |
| Optional<Percent> targetReheat) override; |
| |
| /** |
| * @brief Delegate should implement a handler to cancel a boost command. |
| * Upon receipt, the Water Heater SHALL transition back from the |
| * BOOST state to the previous mode (e.g. OFF, MANUAL or TIMED). |
| * |
| * @return It should report SUCCESS if successful and FAILURE otherwise. |
| */ |
| Protocols::InteractionModel::Status HandleCancelBoost() override; |
| |
| // ------------------------------------------------------------------ |
| // Get attribute methods |
| BitMask<WaterHeaterHeatSourceBitmap> GetHeaterTypes() override; |
| BitMask<WaterHeaterHeatSourceBitmap> GetHeatDemand() override; |
| uint16_t GetTankVolume() override; |
| Energy_mWh GetEstimatedHeatRequired() override; |
| Percent GetTankPercentage() override; |
| BoostStateEnum GetBoostState() override; |
| |
| // ------------------------------------------------------------------ |
| // Set attribute methods |
| void SetHeaterTypes(BitMask<WaterHeaterHeatSourceBitmap> heaterTypes); |
| void SetHeatDemand(BitMask<WaterHeaterHeatSourceBitmap> heatDemand); |
| void SetTankVolume(uint16_t tankVolume); |
| void SetEstimatedHeatRequired(Energy_mWh estimatedHeatRequired); |
| void SetTankPercentage(Percent tankPercentage); |
| void SetBoostState(BoostStateEnum boostState); |
| |
| /*************************************************************************** |
| * |
| * WaterHeaterManagementDelegate specific methods |
| * |
| ***************************************************************************/ |
| |
| /** |
| * @brief Set the Water Header Mode and act accordingly. |
| * |
| * @param mode The Water Heater Mode (e.g. OFF, MANUAL or TIMED). |
| */ |
| Protocols::InteractionModel::Status SetWaterHeaterMode(uint8_t mode); |
| |
| /** |
| * @brief Set the water temperature of the tank |
| * |
| * @param waterTemperature The water temperature in 100th's Celsius |
| */ |
| void SetWaterTemperature(int16_t waterTemperature); |
| |
| /** |
| * @brief Set the target water temperature of the tank |
| * |
| * @param targetWaterTemperature The water temperature in 100th's Celsius |
| */ |
| void SetTargetWaterTemperature(int16_t targetWaterTemperature); |
| |
| /** |
| * @brief Determine whether the heating sources need to be turned on or off or left unchanged. |
| * |
| * @return Success if the heating was successfully turned on or off or left unchanged otherwise an error |
| * code is returned if turning the heating on or off failed. |
| */ |
| Protocols::InteractionModel::Status ChangeHeatingIfNecessary(); |
| |
| /** |
| * @brief Static timer callback for when Boost timer expires. |
| */ |
| static void BoostTimerExpiry(System::Layer * systemLayer, void * delegate); |
| |
| /** |
| * @brief Object timer callback for when Boost timer expires. |
| */ |
| void HandleBoostTimerExpiry(); |
| |
| /** |
| * Determines whether the tank water temperature has reached the target |
| * temperature. |
| * |
| * @return Returns True is tank water temperature has reached the target |
| * temperature, False otherwise. |
| */ |
| bool HasWaterTemperatureReachedTarget() const; |
| |
| /** |
| * Simulates water being drawn from the water tank. |
| * |
| * @param percentageReplaced The % of water being replaced with water with |
| * a temperature of replacedWaterTemperature. |
| * |
| * @param replacedWaterTemperature The temperature of the |
| * percentageReplaced water. |
| */ |
| void DrawOffHotWater(Percent percentageReplaced, int16_t replacedWaterTemperature); |
| |
| /** |
| * Set the temperature of the cold water that fills the tank as the hot water |
| * is drawn off. |
| * |
| * @param coldWaterTemperature The cold water temperature in 100th of a C |
| */ |
| void SetColdWaterTemperature(int16_t coldWaterTemperature); |
| |
| private: |
| /** |
| * Return the target temperature. |
| * If a boost command is in progress and has a mBoostTemporarySetpoint value use that as the |
| * target temperature otherwise use the temperature set via SetTargetWaterTemperature(). |
| * |
| * @return the target temperature |
| */ |
| int16_t GetActiveTargetWaterTemperature() const; |
| |
| /** |
| * @brief Calculate the percentage of the water in the tank at the target |
| * temperature. |
| * |
| * @return Percentage of water at the target temperature |
| */ |
| uint8_t CalculateTankPercentage() const; |
| |
| /** |
| * @brief Determine whether heating needs to be turned on or off or left as |
| * is. |
| * |
| * @param heatingOp[out] Set as determined whether heating needs to be |
| * turned on/off or left unchanged. |
| * |
| * @return Success if the heating operation could be determined otherwise |
| * returns with appropriate error. |
| */ |
| Protocols::InteractionModel::Status DetermineIfChangingHeatingState(HeatingOp & heatingOp); |
| |
| private: |
| /*************************************************************************** |
| * |
| * WaterHeaterManagementDelegate specific attributes |
| * |
| ***************************************************************************/ |
| |
| // Need the following so can determine which features are supported |
| WaterHeaterManagement::Instance * mpWhmInstance; |
| |
| // Pointer to the manufacturer specific object which understand the hardware |
| WhmManufacturer * mpWhmManufacturer; |
| |
| // Target water temperature in 100ths of a C |
| int16_t mTargetWaterTemperature; |
| |
| // Actual water temperature in 100ths of a C |
| int16_t mWaterTemperature; |
| |
| // The cold water temperature in 100ths of a C |
| int16_t mColdWaterTemperature; |
| |
| // Boost command parameters |
| |
| // This field SHALL indicate whether the BOOST state should be automatically |
| // canceled once the hot water has first reached the set point temperature |
| // (or the TemporarySetpoint temperature, if specified) for the |
| // TargetPercentage (if specified). |
| Optional<bool> mBoostOneShot; |
| |
| // This field indicates that the consumer wants the water to be heated as |
| // quickly as practicable. This MAY cause multiple heat sources to be |
| // activated (e.g. a heat pump and direct electric heating element). |
| Optional<bool> mBoostEmergencyBoost; |
| |
| // This field indicates the target temperature to which to heat the hot |
| // water for this Boost command. It SHALL be used instead of the normal set |
| // point temperature whilst the BOOST state is active. |
| Optional<int16_t> mBoostTemporarySetpoint; |
| |
| // If the tank supports the TankPercent feature, this field indicates the |
| // amount of water that SHALL be heated by this Boost command before the |
| // heater is switched off. This field is optional, however it SHALL be |
| // included if the TargetReheat field is included. |
| Optional<Percent> mBoostTargetPercentage; |
| |
| // If the tank supports the TankPercent feature, and the heating by this |
| // Boost command has ceased because the TargetPercentage of the water in the |
| // tank has been heated to the set point (or TemporarySetpoint if included), |
| // this field indicates the percentage to which the hot water in the tank |
| // SHALL be allowed to fall before again beginning to reheat it. For example |
| // if the TargetPercentage was 80%, and the TargetReheat was 40%, then after |
| // initial heating to 80% hot water, the tank may have hot water drawn off |
| // until only 40% hot water remains. At this point the heater will begin to |
| // heat back up to 80% of hot water. If this field and the OneShot field |
| // were both omitted, heating would begin again after any water draw which |
| // reduced the TankPercentage below 80%. |
| Optional<Percent> mBoostTargetReheat; |
| |
| // Track whether the water temperature has reached the water temperature |
| // specified in the boost command. Used in conjunction with the boost |
| // command boostTargetReheat parameter |
| bool mBoostTargetTemperatureReached; |
| |
| /********************************************************************************* |
| * |
| * Member variables implementing the WaterHeaterManagement::Delegate interface |
| * |
| *********************************************************************************/ |
| |
| // This attribute SHALL indicate the methods to call for heat that the |
| // controller supports. If a bit is set then the controller supports the |
| // corresponding method. |
| BitMask<WaterHeaterHeatSourceBitmap> mHeaterTypes; |
| |
| // This attribute SHALL indicate if the controller is asking for heat. If a |
| // bit is set then the corresponding call for heat is active. |
| BitMask<WaterHeaterHeatSourceBitmap> mHeatDemand; |
| |
| // This attribute SHALL indicate the volume of water that the hot water tank |
| // can hold (in units of Litres). This allows an energy management system to |
| // estimate the required heating energy needed to reach the target |
| // temperature. |
| uint16_t mTankVolume; |
| |
| // This attribute SHALL indicate the estimated heat energy needed to raise |
| // the water temperature to the target setpoint. This can be computed by |
| // taking the specific heat capacity of water (4182 J/kg °C) and by knowing |
| // the current temperature of the water, the tank volume and target |
| // temperature. |
| Energy_mWh mEstimatedHeatRequired; |
| |
| // This attribute SHALL indicate an approximate level of hot water stored in |
| // the tank, which may help consumers understand the amount of hot water |
| // remaining in the tank. |
| Percent mTankPercentage; |
| |
| // This attribute SHALL indicate if the BOOST state, as triggered by a Boost |
| // command, is currently active. |
| BoostStateEnum mBoostState; |
| }; |
| |
| } // namespace WaterHeaterManagement |
| } // namespace Clusters |
| } // namespace app |
| } // namespace chip |