| <?xml version="1.0"?> |
| <!--
|
| Copyright (C) Connectivity Standards Alliance (2021). All rights reserved.
|
| The information within this document is the property of the Connectivity
|
| Standards Alliance and its use and disclosure are restricted, except as
|
| expressly set forth herein.
|
|
|
| Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive,
|
| nontransferable, worldwide, limited and revocable license (without the right to
|
| sublicense), under Connectivity Standards Alliance's applicable copyright
|
| rights, to view, download, save, reproduce and use the document solely for your
|
| own internal purposes and in accordance with the terms of the license set forth
|
| herein. This license does not authorize you to, and you expressly warrant that
|
| you shall not: (a) permit others (outside your organization) to use this
|
| document; (b) post or publish this document; (c) modify, adapt, translate, or
|
| otherwise change this document in any manner or create any derivative work
|
| based on this document; (d) remove or modify any notice or label on this
|
| document, including this Copyright Notice, License and Disclaimer. The
|
| Connectivity Standards Alliance does not grant you any license hereunder other
|
| than as expressly stated herein.
|
|
|
| Elements of this document may be subject to third party intellectual property
|
| rights, including without limitation, patent, copyright or trademark rights,
|
| and any such third party may or may not be a member of the Connectivity
|
| Standards Alliance. Connectivity Standards Alliance members grant other
|
| Connectivity Standards Alliance members certain intellectual property rights as
|
| set forth in the Connectivity Standards Alliance IPR Policy. Connectivity
|
| Standards Alliance members do not grant you any rights under this license. The
|
| Connectivity Standards Alliance is not responsible for, and shall not be held
|
| responsible in any manner for, identifying or failing to identify any or all
|
| such third party intellectual property rights. Please visit www.csa-iot.org for
|
| more information on how to become a member of the Connectivity Standards
|
| Alliance.
|
|
|
| This document and the information contained herein are provided on an “AS IS”
|
| basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS
|
| OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE
|
| INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING
|
| WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT
|
| OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS
|
| FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE
|
| CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF
|
| BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER
|
| DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL
|
| DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT
|
| OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
|
| LOSS OR DAMAGE.
|
|
|
| All company, brand and product names in this document may be trademarks that
|
| are the sole property of their respective owners.
|
|
|
| This notice and disclaimer must be included on all copies of this document.
|
|
|
| Connectivity Standards Alliance
|
| 508 Second Street, Suite 206
|
| Davis, CA 95616, USA
|
|
|
| // Update Name
|
| --> |
| <cluster xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="types types.xsd cluster cluster.xsd" id="0x0046" name="ICD Management Cluster" revision="3"> |
| <revisionHistory> |
| <revision revision="1" summary="Initial revision"/> |
| <revision revision="2" summary="Addition of LIT ICD support, UserActiveModeTrigger, ActiveModeDuration, StayActiveResponse; removal of field Key in MonitoringRegistrationStruct"/> |
| <revision revision="3" summary="Addition of the ClientType attribute; addition of the ICD Check-In Backoff support; addition of the DynamicSitLitSupport feature"/> |
| </revisionHistory> |
| <clusterIds> |
| <clusterId id="0x0046" name="ICDManagement"/> |
| </clusterIds> |
| <classification hierarchy="base" role="utility" picsCode="ICDM" scope="Node"/> |
| <features> |
| <feature bit="0" code="CIP" name="CheckInProtocolSupport" summary="Device supports attributes and commands for the Check-In Protocol support."> |
| <otherwiseConform> |
| <provisionalConform/> |
| <mandatoryConform> |
| <feature name="LITS"/> |
| </mandatoryConform> |
| <optionalConform/> |
| </otherwiseConform> |
| </feature> |
| <feature bit="1" code="UAT" name="UserActiveModeTrigger" summary="Device supports the user active mode trigger feature."> |
| <otherwiseConform> |
| <provisionalConform/> |
| <mandatoryConform> |
| <feature name="LITS"/> |
| </mandatoryConform> |
| <optionalConform/> |
| </otherwiseConform> |
| </feature> |
| <feature bit="2" code="LITS" name="LongIdleTimeSupport" summary="Device supports operating as a Long Idle Time ICD."> |
| <otherwiseConform> |
| <provisionalConform/> |
| <optionalConform/> |
| </otherwiseConform> |
| </feature> |
| <feature bit="3" code="DSLS" name="DynamicSitLitSupport" summary="Device supports dynamic switching from SIT to LIT operating modes."> |
| <otherwiseConform> |
| <provisionalConform/> |
| <optionalConform> |
| <feature name="LITS"/> |
| </optionalConform> |
| </otherwiseConform> |
| </feature> |
| </features> |
| <dataTypes> |
| <number name="ClientType Field" type=""/> |
| <enum name="OperatingModeEnum"> |
| <item value="0" name="SIT" summary="ICD is operating as a Short Idle Time ICD."> |
| <mandatoryConform/> |
| </item> |
| <item value="1" name="LIT" summary="ICD is operating as a Long Idle Time ICD."> |
| <mandatoryConform/> |
| </item> |
| </enum> |
| <bitmap name="UserActiveModeTriggerBitmap"> |
| <bitfield name="PowerCycle" bit="0" summary="Power Cycle to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="SettingsMenu" bit="1" summary="Settings menu on the device informs how to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="CustomInstruction" bit="2" summary="Custom Instruction on how to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="DeviceManual" bit="3" summary="Device Manual informs how to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="ActuateSensor" bit="4" summary="Actuate Sensor to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="ActuateSensorSeconds" bit="5" summary="Actuate Sensor for N seconds to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="ActuateSensorTimes" bit="6" summary="Actuate Sensor N times to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="ActuateSensorLightsBlink" bit="7" summary="Actuate Sensor until light blinks to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="ResetButton" bit="8" summary="Press Reset Button to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="ResetButtonLightsBlink" bit="9" summary="Press Reset Button until light blinks to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="ResetButtonSeconds" bit="10" summary="Press Reset Button for N seconds to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="ResetButtonTimes" bit="11" summary="Press Reset Button N times to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="SetupButton" bit="12" summary="Press Setup Button to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="SetupButtonSeconds" bit="13" summary="Press Setup Button for N seconds to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="SetupButtonLightsBlink" bit="14" summary="Press Setup Button until light blinks to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="SetupButtonTimes" bit="15" summary="Press Setup Button N times to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="AppDefinedButton" bit="16" summary="Press the N Button to transition the device to ActiveMode"> |
| <mandatoryConform/> |
| </bitfield> |
| </bitmap> |
| <struct name="MonitoringRegistrationStruct"> |
| <field id="1" name="CheckInNodeID" type="node-id"> |
| <access fabricSensitive="true"/> |
| <mandatoryConform/> |
| </field> |
| <field id="2" name="MonitoredSubject" type="subject-id"> |
| <access fabricSensitive="true"/> |
| <mandatoryConform/> |
| </field> |
| <field id="3" name="Key"> |
| <deprecateConform/> |
| </field> |
| <field id="4" name="ClientType" type="ClientTypeEnum" default="0"> |
| <access fabricSensitive="true"/> |
| <mandatoryConform/> |
| </field> |
| <access fabricScoped="true"/> |
| </struct> |
| </dataTypes> |
| <attributes> |
| <attribute id="0x0000" name="IdleModeDuration" type="uint32" default="1"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/> |
| <mandatoryConform/> |
| <constraint type="between" from="1" to="64800"/> |
| </attribute> |
| <attribute id="0x0001" name="ActiveModeDuration" type="uint32" default="300"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0002" name="ActiveModeThreshold" type="uint16" default="300"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0003" name="RegisteredClients" type="list" default="[]"> |
| <entry type="MonitoringRegistrationStruct"/> |
| <access read="true" readPrivilege="admin" fabricScoped="true"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/> |
| <mandatoryConform> |
| <feature name="CIP"/> |
| </mandatoryConform> |
| <constraint type="desc"/> |
| </attribute> |
| <attribute id="0x0004" name="ICDCounter" type="uint32" default="0"> |
| <access read="true" readPrivilege="admin"/> |
| <quality changeOmitted="true" nullable="false" scene="false" persistence="nonVolatile" reportable="false" sourceAttribution="false" quieterReporting="false"/> |
| <mandatoryConform> |
| <feature name="CIP"/> |
| </mandatoryConform> |
| </attribute> |
| <attribute id="0x0005" name="ClientsSupportedPerFabric" type="uint16" default="1"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/> |
| <mandatoryConform> |
| <feature name="CIP"/> |
| </mandatoryConform> |
| <constraint type="min" value="1"/> |
| </attribute> |
| <attribute id="0x0006" name="UserActiveModeTriggerHint" type="UserActiveModeTriggerBitmap" default="0"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/> |
| <otherwiseConform> |
| <provisionalConform/> |
| <mandatoryConform> |
| <feature name="UAT"/> |
| </mandatoryConform> |
| </otherwiseConform> |
| <constraint type="desc"/> |
| </attribute> |
| <attribute id="0x0007" name="UserActiveModeTriggerInstruction" type="string" default="""> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/> |
| <constraint type="maxLength" value="128"/> |
| </attribute> |
| <attribute id="0x0008" name="OperatingMode" type="OperatingModeEnum"> |
| <access read="true" readPrivilege="view"/> |
| <otherwiseConform> |
| <provisionalConform/> |
| <mandatoryConform> |
| <feature name="LITS"/> |
| </mandatoryConform> |
| </otherwiseConform> |
| </attribute> |
| <attribute id="0x0009" name="MaximumCheckInBackoff" type="uint32" default="1"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false" sourceAttribution="false" quieterReporting="false"/> |
| <mandatoryConform> |
| <feature name="CIP"/> |
| </mandatoryConform> |
| <constraint type="between" from="IdleModeDuration" to="64800"/> |
| </attribute> |
| </attributes> |
| <commands> |
| <command id="0x00" name="RegisterClient" direction="commandToServer" response="RegisterClientResponse"> |
| <access invokePrivilege="manage" fabricScoped="true"/> |
| <mandatoryConform> |
| <feature name="CIP"/> |
| </mandatoryConform> |
| <field id="0" name="CheckInNodeID" type="node-id"> |
| <mandatoryConform/> |
| </field> |
| <field id="1" name="MonitoredSubject" type="subject-id"> |
| <mandatoryConform/> |
| </field> |
| <field id="2" name="Key" type="octstr"> |
| <mandatoryConform/> |
| <constraint type="maxLength" value="16"/> |
| </field> |
| <field id="3" name="VerificationKey" type="octstr"> |
| <optionalConform/> |
| <constraint type="maxLength" value="16"/> |
| </field> |
| <field id="4" name="ClientType" type="ClientTypeEnum"> |
| <mandatoryConform/> |
| </field> |
| </command> |
| <command id="0x01" name="RegisterClientResponse" direction="responseFromServer"> |
| <mandatoryConform> |
| <feature name="CIP"/> |
| </mandatoryConform> |
| <field id="0" name="ICDCounter" type="uint32"> |
| <mandatoryConform/> |
| </field> |
| </command> |
| <command id="0x02" name="UnregisterClient" direction="commandToServer" response="Y"> |
| <access invokePrivilege="manage" fabricScoped="true"/> |
| <mandatoryConform> |
| <feature name="CIP"/> |
| </mandatoryConform> |
| <field id="0" name="CheckInNodeID" type="node-id"> |
| <mandatoryConform/> |
| </field> |
| <field id="1" name="VerificationKey" type="octstr"> |
| <optionalConform/> |
| <constraint type="maxLength" value="16"/> |
| </field> |
| </command> |
| <command id="0x03" name="StayActiveRequest" direction="commandToServer" response="StayActiveResponse"> |
| <access invokePrivilege="operate"/> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="LITS"/> |
| </mandatoryConform> |
| <optionalConform/> |
| </otherwiseConform> |
| <field id="0" name="StayActiveDuration" type="uint32"> |
| <mandatoryConform/> |
| </field> |
| </command> |
| <command id="0x04" name="StayActiveResponse" direction="responseFromServer"> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="LITS"/> |
| </mandatoryConform> |
| <optionalConform/> |
| </otherwiseConform> |
| <field id="0" name="PromisedActiveDuration" type="uint32"> |
| <mandatoryConform/> |
| <constraint type="desc"/> |
| </field> |
| </command> |
| </commands> |
| </cluster> |