| <?xml version="1.0"?> | |
| <!-- | |
| Copyright (C) Connectivity Standards Alliance (2026). All rights reserved. | |
| The information within this document is the property of the Connectivity | |
| Standards Alliance and its use and disclosure are restricted, except as | |
| expressly set forth herein. | |
| Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive, | |
| nontransferable, worldwide, limited and revocable license (without the right to | |
| sublicense), under Connectivity Standards Alliance's applicable copyright | |
| rights, to view, download, save, reproduce and use the document solely for your | |
| own internal purposes and in accordance with the terms of the license set forth | |
| herein. This license does not authorize you to, and you expressly warrant that | |
| you shall not: (a) permit others (outside your organization) to use this | |
| document; (b) post or publish this document; (c) modify, adapt, translate, or | |
| otherwise change this document in any manner or create any derivative work | |
| based on this document; (d) remove or modify any notice or label on this | |
| document, including this Copyright Notice, License and Disclaimer. The | |
| Connectivity Standards Alliance does not grant you any license hereunder other | |
| than as expressly stated herein. | |
| Elements of this document may be subject to third party intellectual property | |
| rights, including without limitation, patent, copyright or trademark rights, | |
| and any such third party may or may not be a member of the Connectivity | |
| Standards Alliance. Connectivity Standards Alliance members grant other | |
| Connectivity Standards Alliance members certain intellectual property rights as | |
| set forth in the Connectivity Standards Alliance IPR Policy. Connectivity | |
| Standards Alliance members do not grant you any rights under this license. The | |
| Connectivity Standards Alliance is not responsible for, and shall not be held | |
| responsible in any manner for, identifying or failing to identify any or all | |
| such third party intellectual property rights. Please visit www.csa-iot.org for | |
| more information on how to become a member of the Connectivity Standards | |
| Alliance. | |
| This document and the information contained herein are provided on an “AS IS” | |
| basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS | |
| OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE | |
| INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING | |
| WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT | |
| OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS | |
| FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE | |
| CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF | |
| BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER | |
| DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL | |
| DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT | |
| OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH | |
| LOSS OR DAMAGE. | |
| All company, brand and product names in this document may be trademarks that | |
| are the sole property of their respective owners. | |
| This notice and disclaimer must be included on all copies of this document. | |
| Connectivity Standards Alliance | |
| 508 Second Street, Suite 206 | |
| Davis, CA 95616, USA | |
| :xrefstyle: basic | |
| --> | |
| <cluster xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="types types.xsd cluster cluster.xsd" id="0x0090" name="Electrical Power Measurement Cluster" revision="3"> | |
| <revisionHistory> | |
| <revision revision="1" summary="Initial revision"/> | |
| <revision revision="2" summary="Changed reactive and apparent power fields to use new data types"/> | |
| <revision revision="3" summary="Changed range of apparent current field to allow negative apparent current"/> | |
| </revisionHistory> | |
| <clusterIds> | |
| <clusterId id="0x0090" name="Electrical Power Measurement"/> | |
| </clusterIds> | |
| <classification hierarchy="base" role="application" picsCode="EPM" scope="Endpoint"/> | |
| <features> | |
| <feature bit="0" code="DIRC" name="DirectCurrent" summary="Supports measurement of direct current"> | |
| <optionalConform choice="a" more="true" min="1"/> | |
| </feature> | |
| <feature bit="1" code="ALTC" name="AlternatingCurrent" summary="Supports measurement of alternating current"> | |
| <optionalConform choice="a" more="true" min="1"/> | |
| </feature> | |
| <feature bit="2" code="POLY" name="PolyphasePower" summary="Supports polyphase measurements"> | |
| <optionalConform> | |
| <feature name="ALTC"/> | |
| </optionalConform> | |
| </feature> | |
| <feature bit="3" code="HARM" name="Harmonics" summary="Supports measurement of AC harmonics"> | |
| <optionalConform> | |
| <feature name="ALTC"/> | |
| </optionalConform> | |
| </feature> | |
| <feature bit="4" code="PWRQ" name="PowerQuality" summary="Supports measurement of AC harmonic phases"> | |
| <optionalConform> | |
| <feature name="ALTC"/> | |
| </optionalConform> | |
| </feature> | |
| </features> | |
| <dataTypes> | |
| <enum name="MeasurementTypeEnum"> | |
| <item value="0" name="Unspecified"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="1" name="Voltage" summary="Voltage in millivolts (mV)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="2" name="ActiveCurrent" summary="Active current in milliamps (mA)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="3" name="ReactiveCurrent" summary="Reactive current in milliamps (mA)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="4" name="ApparentCurrent" summary="Apparent current in milliamps (mA)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="5" name="ActivePower" summary="Active power in milliwatts (mW)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="6" name="ReactivePower" summary="Reactive power in millivolt-amps reactive (mVAR)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="7" name="ApparentPower" summary="Apparent power in millivolt-amps (mVA)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="8" name="RMSVoltage" summary="Root mean squared voltage in millivolts (mV)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="9" name="RMSCurrent" summary="Root mean squared current in milliamps (mA)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="10" name="RMSPower" summary="Root mean squared power in milliwatts (mW)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="11" name="Frequency" summary="AC frequency in millihertz (mHz)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="12" name="PowerFactor" summary="Power Factor ratio in +/- 1/100ths of a percent."> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="13" name="NeutralCurrent" summary="AC neutral current in milliamps (mA)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="14" name="ElectricalEnergy" summary="Electrical energy in milliwatt-hours (mWh)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="15" name="ReactiveEnergy" summary="Reactive power in millivolt-amp-hours reactive (mVARh)"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="16" name="ApparentEnergy" summary="Apparent power in millivolt-amp-hours (mVAh)"> | |
| <mandatoryConform/> | |
| </item> | |
| </enum> | |
| <enum name="PowerModeEnum"> | |
| <item value="0" name="Unknown"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="1" name="DC" summary="Direct current"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="2" name="AC" summary="Alternating current, either single-phase or polyphase"> | |
| <mandatoryConform/> | |
| </item> | |
| </enum> | |
| <struct name="HarmonicMeasurementStruct"> | |
| <field id="0" name="Order" type="uint8"> | |
| <mandatoryConform/> | |
| <constraint> | |
| <min value="1"/> | |
| </constraint> | |
| </field> | |
| <field id="1" name="Measurement" type="int64"> | |
| <quality nullable="true"/> | |
| <mandatoryConform/> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </field> | |
| </struct> | |
| <struct name="MeasurementAccuracyRangeStruct"> | |
| <field id="0" name="RangeMin" type="int64"> | |
| <mandatoryConform/> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </field> | |
| <field id="1" name="RangeMax" type="int64"> | |
| <mandatoryConform/> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </field> | |
| <field id="2" name="PercentMax" type="percent100ths"> | |
| <optionalConform choice="a" more="true" min="1"/> | |
| </field> | |
| <field id="3" name="PercentMin" type="percent100ths"> | |
| <optionalConform> | |
| <field name="PercentMax"/> | |
| </optionalConform> | |
| <constraint> | |
| <max> | |
| <field name="PercentTypical"/> | |
| </max> | |
| </constraint> | |
| </field> | |
| <field id="4" name="PercentTypical" type="percent100ths"> | |
| <optionalConform> | |
| <field name="PercentMin"/> | |
| </optionalConform> | |
| <constraint> | |
| <between> | |
| <from> | |
| <field name="PercentMin"/> | |
| </from> | |
| <to> | |
| <field name="PercentMax"/> | |
| </to> | |
| </between> | |
| </constraint> | |
| </field> | |
| <field id="5" name="FixedMax" type="uint64"> | |
| <optionalConform choice="a" more="true" min="1"/> | |
| <constraint> | |
| <max> | |
| <compute> | |
| <operation>subtract</operation> | |
| <left value="4611686018427387904"/> | |
| <right value="1"/> | |
| </compute> | |
| </max> | |
| </constraint> | |
| </field> | |
| <field id="6" name="FixedMin" type="uint64"> | |
| <optionalConform> | |
| <field name="FixedMax"/> | |
| </optionalConform> | |
| <constraint> | |
| <max> | |
| <field name="FixedMax"/> | |
| </max> | |
| </constraint> | |
| </field> | |
| <field id="7" name="FixedTypical" type="uint64"> | |
| <optionalConform> | |
| <field name="FixedMin"/> | |
| </optionalConform> | |
| <constraint> | |
| <between> | |
| <from> | |
| <field name="FixedMin"/> | |
| </from> | |
| <to> | |
| <field name="FixedMax"/> | |
| </to> | |
| </between> | |
| </constraint> | |
| </field> | |
| </struct> | |
| <struct name="MeasurementAccuracyStruct"> | |
| <field id="0" name="MeasurementType" type="MeasurementTypeEnum"> | |
| <mandatoryConform/> | |
| </field> | |
| <field id="1" name="Measured" type="bool"> | |
| <mandatoryConform/> | |
| </field> | |
| <field id="2" name="MinMeasuredValue" type="int64"> | |
| <mandatoryConform/> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </field> | |
| <field id="3" name="MaxMeasuredValue" type="int64"> | |
| <mandatoryConform/> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </field> | |
| <field id="4" name="AccuracyRanges" type="list"> | |
| <entry type="MeasurementAccuracyRangeStruct"/> | |
| <mandatoryConform/> | |
| <constraint> | |
| <minCount value="1"/> | |
| </constraint> | |
| </field> | |
| </struct> | |
| <struct name="MeasurementRangeStruct"> | |
| <field id="0" name="MeasurementType" type="MeasurementTypeEnum"> | |
| <mandatoryConform/> | |
| </field> | |
| <field id="1" name="Min" type="int64"> | |
| <mandatoryConform/> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </field> | |
| <field id="2" name="Max" type="int64"> | |
| <mandatoryConform/> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </field> | |
| <field id="3" name="StartTimestamp" type="epoch-s"> | |
| <mandatoryConform> | |
| <field name="EndTimestamp"/> | |
| </mandatoryConform> | |
| </field> | |
| <field id="4" name="EndTimestamp" type="epoch-s"> | |
| <describedConform/> | |
| <constraint> | |
| <min> | |
| <compute> | |
| <operation>add</operation> | |
| <left> | |
| <field name="StartTimestamp"/> | |
| </left> | |
| <right value="1"/> | |
| </compute> | |
| </min> | |
| </constraint> | |
| </field> | |
| <field id="5" name="MinTimestamp" type="epoch-s"> | |
| <mandatoryConform> | |
| <field name="EndTimestamp"/> | |
| </mandatoryConform> | |
| </field> | |
| <field id="6" name="MaxTimestamp" type="epoch-s"> | |
| <mandatoryConform> | |
| <field name="EndTimestamp"/> | |
| </mandatoryConform> | |
| <constraint> | |
| <min> | |
| <compute> | |
| <operation>add</operation> | |
| <left> | |
| <field name="MinTimestamp"/> | |
| </left> | |
| <right value="1"/> | |
| </compute> | |
| </min> | |
| </constraint> | |
| </field> | |
| <field id="7" name="StartSystime" type="systime-ms"> | |
| <mandatoryConform> | |
| <field name="EndSystime"/> | |
| </mandatoryConform> | |
| </field> | |
| <field id="8" name="EndSystime" type="systime-ms"> | |
| <describedConform/> | |
| <constraint> | |
| <min> | |
| <compute> | |
| <operation>add</operation> | |
| <left> | |
| <field name="StartSystime"/> | |
| </left> | |
| <right value="1"/> | |
| </compute> | |
| </min> | |
| </constraint> | |
| </field> | |
| <field id="9" name="MinSystime" type="systime-ms"> | |
| <mandatoryConform> | |
| <field name="EndSystime"/> | |
| </mandatoryConform> | |
| </field> | |
| <field id="10" name="MaxSystime" type="systime-ms"> | |
| <mandatoryConform> | |
| <field name="EndSystime"/> | |
| </mandatoryConform> | |
| <constraint> | |
| <min> | |
| <compute> | |
| <operation>add</operation> | |
| <left> | |
| <field name="MinSystime"/> | |
| </left> | |
| <right value="1"/> | |
| </compute> | |
| </min> | |
| </constraint> | |
| </field> | |
| </struct> | |
| </dataTypes> | |
| <attributes> | |
| <attribute id="0x0000" name="PowerMode" type="PowerModeEnum"> | |
| <access read="true" readPrivilege="view"/> | |
| <mandatoryConform/> | |
| </attribute> | |
| <attribute id="0x0001" name="NumberOfMeasurementTypes" type="uint8"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality persistence="fixed"/> | |
| <mandatoryConform/> | |
| <constraint> | |
| <max value="32"/> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x0002" name="Accuracy" type="list"> | |
| <entry type="MeasurementAccuracyStruct"/> | |
| <access read="true" readPrivilege="view"/> | |
| <quality persistence="fixed"/> | |
| <mandatoryConform/> | |
| <constraint> | |
| <countBetween> | |
| <from value="1"/> | |
| <to> | |
| <attribute name="NumberOfMeasurementTypes"/> | |
| </to> | |
| </countBetween> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x0003" name="Ranges" type="list" default="empty"> | |
| <entry type="MeasurementRangeStruct"/> | |
| <access read="true" readPrivilege="view"/> | |
| <quality quieterReporting="true"/> | |
| <optionalConform/> | |
| <constraint> | |
| <countBetween> | |
| <from value="0"/> | |
| <to> | |
| <attribute name="NumberOfMeasurementTypes"/> | |
| </to> | |
| </countBetween> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x0004" name="Voltage" type="voltage-mV" default="null"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <optionalConform/> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x0005" name="ActiveCurrent" type="amperage-mA" default="null"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <optionalConform/> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x0006" name="ReactiveCurrent" type="amperage-mA" default="null"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <optionalConform> | |
| <feature name="ALTC"/> | |
| </optionalConform> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x0007" name="ApparentCurrent" type="amperage-mA" default="null"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <optionalConform> | |
| <feature name="ALTC"/> | |
| </optionalConform> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x0008" name="ActivePower" type="power-mW"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <mandatoryConform/> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x0009" name="ReactivePower" type="power-mVAR" default="null"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <optionalConform> | |
| <feature name="ALTC"/> | |
| </optionalConform> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x000A" name="ApparentPower" type="power-mVA" default="null"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <optionalConform> | |
| <feature name="ALTC"/> | |
| </optionalConform> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x000B" name="RMSVoltage" type="voltage-mV" default="null"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <optionalConform> | |
| <feature name="ALTC"/> | |
| </optionalConform> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x000C" name="RMSCurrent" type="amperage-mA" default="null"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <optionalConform> | |
| <feature name="ALTC"/> | |
| </optionalConform> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x000D" name="RMSPower" type="power-mW" default="null"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <optionalConform> | |
| <feature name="ALTC"/> | |
| </optionalConform> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x000E" name="Frequency" type="int64" default="null"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <optionalConform> | |
| <feature name="ALTC"/> | |
| </optionalConform> | |
| <constraint> | |
| <between> | |
| <from value="0"/> | |
| <to value="1000000"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x000F" name="HarmonicCurrents" type="list"> | |
| <entry type="HarmonicMeasurementStruct"/> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <mandatoryConform> | |
| <feature name="HARM"/> | |
| </mandatoryConform> | |
| <constraint> | |
| <maxCount value="25"/> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x0010" name="HarmonicPhases" type="list"> | |
| <entry type="HarmonicMeasurementStruct"/> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <mandatoryConform> | |
| <feature name="PWRQ"/> | |
| </mandatoryConform> | |
| <constraint> | |
| <maxCount value="25"/> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x0011" name="PowerFactor" type="int64" default="null"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <optionalConform> | |
| <feature name="ALTC"/> | |
| </optionalConform> | |
| <constraint> | |
| <between> | |
| <from value="-10000"/> | |
| <to value="10000"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x0012" name="NeutralCurrent" type="amperage-mA" default="null"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality nullable="true" quieterReporting="true"/> | |
| <optionalConform> | |
| <feature name="POLY"/> | |
| </optionalConform> | |
| <constraint> | |
| <between> | |
| <from value="-4611686018427387904"/> | |
| <to value="4611686018427387904"/> | |
| </between> | |
| </constraint> | |
| </attribute> | |
| </attributes> | |
| <events> | |
| <event id="0x00" name="MeasurementPeriodRanges" priority="info"> | |
| <access readPrivilege="view"/> | |
| <mandatoryConform> | |
| <attribute name="Ranges"/> | |
| </mandatoryConform> | |
| <field id="0" name="Ranges" type="list"> | |
| <entry type="MeasurementRangeStruct"/> | |
| <mandatoryConform/> | |
| <constraint> | |
| <countBetween> | |
| <from value="1"/> | |
| <to> | |
| <attribute name="NumberOfMeasurementTypes"/> | |
| </to> | |
| </countBetween> | |
| </constraint> | |
| </field> | |
| </event> | |
| </events> | |
| </cluster> |