blob: 8ac92edb429731985fc134e2bdadfc1ffac3bcb9 [file]
<?xml version="1.0"?>
<!--
Copyright (C) Connectivity Standards Alliance (2026). All rights reserved.
The information within this document is the property of the Connectivity
Standards Alliance and its use and disclosure are restricted, except as
expressly set forth herein.
Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive,
nontransferable, worldwide, limited and revocable license (without the right to
sublicense), under Connectivity Standards Alliance's applicable copyright
rights, to view, download, save, reproduce and use the document solely for your
own internal purposes and in accordance with the terms of the license set forth
herein. This license does not authorize you to, and you expressly warrant that
you shall not: (a) permit others (outside your organization) to use this
document; (b) post or publish this document; (c) modify, adapt, translate, or
otherwise change this document in any manner or create any derivative work
based on this document; (d) remove or modify any notice or label on this
document, including this Copyright Notice, License and Disclaimer. The
Connectivity Standards Alliance does not grant you any license hereunder other
than as expressly stated herein.
Elements of this document may be subject to third party intellectual property
rights, including without limitation, patent, copyright or trademark rights,
and any such third party may or may not be a member of the Connectivity
Standards Alliance. Connectivity Standards Alliance members grant other
Connectivity Standards Alliance members certain intellectual property rights as
set forth in the Connectivity Standards Alliance IPR Policy. Connectivity
Standards Alliance members do not grant you any rights under this license. The
Connectivity Standards Alliance is not responsible for, and shall not be held
responsible in any manner for, identifying or failing to identify any or all
such third party intellectual property rights. Please visit www.csa-iot.org for
more information on how to become a member of the Connectivity Standards
Alliance.
This document and the information contained herein are provided on an “AS IS”
basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE
INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING
WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT
OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS
FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE
CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF
BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER
DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL
DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT
OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
LOSS OR DAMAGE.
All company, brand and product names in this document may be trademarks that
are the sole property of their respective owners.
This notice and disclaimer must be included on all copies of this document.
Connectivity Standards Alliance
508 Second Street, Suite 206
Davis, CA 95616, USA
:xrefstyle: basic
-->
<cluster xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="types types.xsd cluster cluster.xsd" id="0x00A3" name="Electrical Protection Alarm Cluster" revision="1">
<revisionHistory>
<revision revision="1" summary="Initial revision"/>
</revisionHistory>
<clusterIds>
<clusterId id="0x00A3" name="Electrical Protection Alarm">
<provisionalConform/>
</clusterId>
</clusterIds>
<classification hierarchy="derived" baseCluster="Alarm Base" role="utility" picsCode="EPALM" scope="Endpoint"/>
<features>
<feature bit="0" code="RESET" name="Reset" summary="Supports the ability to reset alarms">
<disallowConform/>
</feature>
<feature bit="20" code="SHORT" name="ShortCircuit" summary="Supports activating alarms when current exceeds a safe threshold">
<optionalConform choice="a" more="true" min="1"/>
</feature>
<feature bit="21" code="OL" name="OverLoad" summary="Supports activating alarms when current exceeds a safe threshold for a period of time">
<optionalConform choice="a" more="true" min="1"/>
</feature>
<feature bit="22" code="OV" name="OverVoltage" summary="Supports activating alarms when voltage exceeds a safe threshold">
<optionalConform choice="a" more="true" min="1"/>
</feature>
<feature bit="23" code="SP" name="SurgeProtection" summary="Supports activating alarms when a transient voltage surge is detected">
<optionalConform choice="a" more="true" min="1"/>
</feature>
<feature bit="24" code="RC" name="ResidualCurrent" summary="Supports activating alarms when a residual current is detected">
<optionalConform choice="a" more="true" min="1"/>
</feature>
<feature bit="25" code="ARC" name="ArcFault" summary="Supports activating alarms when an arc fault is detected">
<optionalConform choice="a" more="true" min="1"/>
</feature>
<feature bit="26" code="SELFTEST" name="SelfTest" summary="Supports activating alarms when a self test is performed">
<optionalConform/>
</feature>
</features>
<dataTypes>
<enum name="CurrentTripCurveEnum">
<item value="0" name="TypeZ" summary="Trips when operating current is 2 to 3 times rated current">
<mandatoryConform/>
</item>
<item value="1" name="TypeB" summary="Trips when operating current is 3 to 5 times rated current">
<mandatoryConform/>
</item>
<item value="2" name="TypeC" summary="Trips when operating current is 5 to 10 times rated current">
<mandatoryConform/>
</item>
<item value="3" name="TypeK" summary="Trips when operating current is 10 to 12 times rated current">
<mandatoryConform/>
</item>
<item value="4" name="TypeD" summary="Trips when operating current is 10 to 20 times rated current">
<mandatoryConform/>
</item>
</enum>
<enum name="CurrentWaveformEnum">
<item value="0" name="AC" summary="Alternating current only">
<mandatoryConform/>
</item>
<item value="1" name="A" summary="Alternating current and pulsating residual direct currents">
<mandatoryConform/>
</item>
<item value="2" name="F" summary="Alternating current and pulsating residual direct currents with mixed frequencies (e.g. Smart Inverters)">
<mandatoryConform/>
</item>
<item value="3" name="B" summary="Alternating current, smooth residual direct currents, and pulsating residual direct currents with mixed frequencies">
<mandatoryConform/>
</item>
</enum>
<enum name="GroundFaultClassEnum">
<item value="0" name="ClassA" summary="Trips when the residual current is 6mA or more">
<mandatoryConform/>
</item>
<item value="1" name="ClassB" summary="Trips when the residual current is 20mA or more">
<mandatoryConform/>
</item>
<item value="2" name="ClassC" summary="Trips when the residual current is 20mA or more, on circuits with no conductor having a voltage to ground greater than 300V">
<mandatoryConform/>
</item>
<item value="3" name="ClassD" summary="Trips when the residual current is 20mA or more, on circuits with one or more conductors having a voltage to ground greater than 300V and a touch voltage that does not exceed 150V">
<mandatoryConform/>
</item>
<item value="4" name="ClassE" summary="Trips when the residual current is 20mA or more, on circuits with one or more conductors having a voltage to ground greater than 300V and a touch voltage that may exceed 150V">
<mandatoryConform/>
</item>
</enum>
<enum name="UtilizationCategoryEnum">
<item value="0" name="CategoryA" summary="No short time-delay">
<mandatoryConform/>
</item>
<item value="1" name="CategoryB" summary="Intentional short time-delay">
<mandatoryConform/>
</item>
</enum>
<bitmap name="AlarmBitmap">
<bitfield name="ShortCircuitFault" bit="0" summary="A short circuit fault is detected">
<mandatoryConform>
<feature name="SHORT"/>
</mandatoryConform>
</bitfield>
<bitfield name="OverLoadFault" bit="1" summary="An over load fault is detected">
<mandatoryConform>
<feature name="OL"/>
</mandatoryConform>
</bitfield>
<bitfield name="OverVoltageFault" bit="2" summary="An over voltage fault is detected">
<mandatoryConform>
<feature name="OV"/>
</mandatoryConform>
</bitfield>
<bitfield name="VoltageSurgeFault" bit="3" summary="A voltage surge fault is detected">
<mandatoryConform>
<feature name="SP"/>
</mandatoryConform>
</bitfield>
<bitfield name="ResidualCurrentFault" bit="4" summary="A residual current is detected">
<mandatoryConform>
<feature name="RC"/>
</mandatoryConform>
</bitfield>
<bitfield name="ArcFault" bit="5" summary="The Arc fault is detected">
<mandatoryConform>
<feature name="ARC"/>
</mandatoryConform>
</bitfield>
<bitfield name="SelfTest" bit="6" summary="A self test has been performed">
<mandatoryConform>
<feature name="SELFTEST"/>
</mandatoryConform>
</bitfield>
</bitmap>
<bitmap name="ArcCauseBitmap">
<bitfield name="Series" bit="0" summary="An arc fault along a single conductor">
<mandatoryConform/>
</bitfield>
<bitfield name="ParallelToNeutral" bit="1" summary="An arc fault between line and neutral">
<mandatoryConform/>
</bitfield>
<bitfield name="ParallelToGround" bit="2" summary="An arc fault between line and ground">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="CurrentTripMechanismBitmap">
<bitfield name="Thermal" bit="0" summary="Over current is detected through thermal means">
<mandatoryConform/>
</bitfield>
<bitfield name="Magnetic" bit="1" summary="Over current is detected via a magnetic field">
<mandatoryConform/>
</bitfield>
<bitfield name="Electronic" bit="2" summary="Over current is detected electronically">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="SurgeProtectionClassBitmap">
<bitfield name="ClassI" bit="0" summary="Protection tested with a 10/350µs impulse waveform">
<mandatoryConform/>
</bitfield>
<bitfield name="ClassII" bit="1" summary="Protection tested with a 8/20µs surge waveform">
<mandatoryConform/>
</bitfield>
<bitfield name="ClassIII" bit="2" summary="Protection tested with a combination waveform (1.2/50µs voltage / 8/20µs current)">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="SurgeProtectionTypeBitmap">
<bitfield name="Type1" bit="0" summary="Protection installed before the main breaker">
<mandatoryConform/>
</bitfield>
<bitfield name="Type2" bit="1" summary="Protection installed on the load side of the main breaker">
<mandatoryConform/>
</bitfield>
<bitfield name="Type3" bit="2" summary="Protection installed at the point of use">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="TrippingCharacteristicsBitmap">
<bitfield name="ShortDelay" bit="0" summary="G Protection has a short delay before tripping">
<mandatoryConform/>
</bitfield>
<bitfield name="Selective" bit="1" summary="S Protection has a longer delay before tripping">
<mandatoryConform/>
</bitfield>
<bitfield name="SuperImmune" bit="2" summary="SI Protection has active filtering to avoid nuisance tripping">
<mandatoryConform/>
</bitfield>
</bitmap>
<bitmap name="VoltageTripMechanismBitmap">
<bitfield name="MOV" bit="0" summary="Metal oxide varistor">
<mandatoryConform/>
</bitfield>
<bitfield name="SAD" bit="1" summary="Silicon Avalanche Diode">
<mandatoryConform/>
</bitfield>
<bitfield name="GDT" bit="2" summary="Gas discharge tube">
<mandatoryConform/>
</bitfield>
</bitmap>
<struct name="ArcFaultRatingsStruct">
<field id="0" name="SeriesArcCurrentSensitivity" type="amperage-mA">
<optionalConform choice="a" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="1" name="ParallelArcCurrentSensitivity" type="amperage-mA">
<optionalConform choice="a" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="2" name="SupportedArcCauses" type="ArcCauseBitmap">
<optionalConform choice="a" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
</struct>
<struct name="OverLoadRatingsStruct">
<field id="0" name="TripCurrent" type="amperage-mA">
<optionalConform choice="c" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="1" name="TripCurve" type="CurrentTripCurveEnum">
<optionalConform choice="c" more="true" min="1"/>
</field>
<field id="2" name="TripMechanism" type="CurrentTripMechanismBitmap">
<optionalConform choice="c" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="3" name="UltimateMaxCurrent" type="amperage-mA">
<optionalConform choice="c" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="4" name="ServiceMaxCurrent" type="amperage-mA">
<optionalConform choice="c" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
</struct>
<struct name="OverVoltageRatingsStruct">
<field id="0" name="TripMechanism" type="VoltageTripMechanismBitmap">
<optionalConform choice="d" more="true" min="1">
<feature name="SP"/>
</optionalConform>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="1" name="TripVoltage" type="voltage-mV">
<optionalConform choice="d" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="2" name="MaxContinuousOperatingVoltage" type="voltage-mV">
<optionalConform choice="d" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="3" name="ResponseTime" type="uint64">
<optionalConform choice="d" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
</struct>
<struct name="ResidualCurrentFaultRatingsStruct">
<field id="0" name="CurrentSensitivity" type="amperage-mA">
<optionalConform choice="b" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="1" name="TripMechanism" type="CurrentTripMechanismBitmap">
<optionalConform choice="b" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="2" name="VoltageDependent" type="bool">
<optionalConform choice="b" more="true" min="1"/>
</field>
<field id="3" name="GroundFaultClass" type="GroundFaultClassEnum">
<optionalConform choice="b" more="true" min="1"/>
</field>
<field id="4" name="Waveform" type="CurrentWaveformEnum">
<optionalConform choice="b" more="true" min="1"/>
</field>
<field id="5" name="TrippingCharacteristic" type="TrippingCharacteristicsBitmap">
<mandatoryConform>
<field name="Waveform"/>
</mandatoryConform>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="6" name="UltimateMaxCurrent" type="amperage-mA">
<optionalConform choice="b" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="7" name="ServiceMaxCurrent" type="amperage-mA">
<optionalConform choice="b" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
</struct>
<struct name="ShortCircuitRatingsStruct">
<field id="0" name="TripCurrent" type="amperage-mA">
<optionalConform choice="e" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="1" name="TripMechanism" type="CurrentTripMechanismBitmap">
<optionalConform choice="e" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="2" name="TripCurve" type="CurrentTripCurveEnum">
<optionalConform choice="e" more="true" min="1"/>
</field>
<field id="3" name="UltimateMaxCurrent" type="amperage-mA">
<optionalConform choice="e" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="4" name="ServiceMaxCurrent" type="amperage-mA">
<optionalConform choice="e" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="5" name="MaxCurrent" type="amperage-mA">
<optionalConform choice="e" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
</struct>
<struct name="SurgeProtectionRatingsStruct">
<field id="0" name="TripMechanism" type="VoltageTripMechanismBitmap">
<optionalConform choice="f" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="1" name="ProtectionClass" type="SurgeProtectionClassBitmap">
<optionalConform choice="f" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="2" name="ProtectionType" type="SurgeProtectionTypeBitmap">
<optionalConform choice="f" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="3" name="MaxContinuousOperatingVoltage" type="voltage-mV">
<optionalConform choice="f" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="4" name="MaxVoltageProtection" type="voltage-mV">
<optionalConform choice="f" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="5" name="MaxTemporaryVoltage" type="voltage-mV">
<optionalConform choice="f" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="6" name="NominalDischargeCurrent" type="amperage-mA">
<optionalConform choice="f" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="7" name="MaximumDischargeCurrent" type="amperage-mA">
<optionalConform choice="f" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="8" name="RatedShortCircuitCurrent" type="amperage-mA">
<optionalConform choice="f" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="9" name="RatedShortTimeWithstandCurrent" type="amperage-mA">
<optionalConform choice="f" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="10" name="EnergyAbsorptionCapability" type="uint64">
<optionalConform choice="f" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
<field id="11" name="ResponseTime" type="uint64">
<optionalConform choice="f" more="true" min="1"/>
<constraint>
<min value="1"/>
</constraint>
</field>
</struct>
</dataTypes>
<attributes>
<attribute id="0x0080" name="ArcCause" type="ArcCauseBitmap">
<access read="true" readPrivilege="view"/>
<quality nullable="true"/>
<mandatoryConform>
<feature name="ARC"/>
</mandatoryConform>
</attribute>
<attribute id="0x0081" name="OverLoadRating" type="OverLoadRatingsStruct">
<access read="true" readPrivilege="view"/>
<quality nullable="true"/>
<mandatoryConform>
<feature name="OL"/>
</mandatoryConform>
</attribute>
<attribute id="0x0082" name="OverVoltageRating" type="OverVoltageRatingsStruct">
<access read="true" readPrivilege="view"/>
<quality nullable="true"/>
<mandatoryConform>
<feature name="OV"/>
</mandatoryConform>
</attribute>
<attribute id="0x0083" name="SurgeProtectionRating" type="SurgeProtectionRatingsStruct">
<access read="true" readPrivilege="view"/>
<quality nullable="true"/>
<mandatoryConform>
<feature name="SP"/>
</mandatoryConform>
</attribute>
<attribute id="0x0084" name="ShortCircuitRating" type="ShortCircuitRatingsStruct">
<access read="true" readPrivilege="view"/>
<quality nullable="true"/>
<mandatoryConform>
<feature name="SHORT"/>
</mandatoryConform>
</attribute>
<attribute id="0x0085" name="ResidualCurrentRating" type="ResidualCurrentFaultRatingsStruct">
<access read="true" readPrivilege="view"/>
<quality nullable="true"/>
<mandatoryConform>
<feature name="RC"/>
</mandatoryConform>
</attribute>
<attribute id="0x0086" name="ArcFaultRating" type="ArcFaultRatingsStruct">
<access read="true" readPrivilege="view"/>
<quality nullable="true"/>
<mandatoryConform>
<feature name="ARC"/>
</mandatoryConform>
</attribute>
</attributes>