| <?xml version="1.0"?> | |
| <!-- | |
| Copyright (C) Connectivity Standards Alliance (2026). All rights reserved. | |
| The information within this document is the property of the Connectivity | |
| Standards Alliance and its use and disclosure are restricted, except as | |
| expressly set forth herein. | |
| Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive, | |
| nontransferable, worldwide, limited and revocable license (without the right to | |
| sublicense), under Connectivity Standards Alliance's applicable copyright | |
| rights, to view, download, save, reproduce and use the document solely for your | |
| own internal purposes and in accordance with the terms of the license set forth | |
| herein. This license does not authorize you to, and you expressly warrant that | |
| you shall not: (a) permit others (outside your organization) to use this | |
| document; (b) post or publish this document; (c) modify, adapt, translate, or | |
| otherwise change this document in any manner or create any derivative work | |
| based on this document; (d) remove or modify any notice or label on this | |
| document, including this Copyright Notice, License and Disclaimer. The | |
| Connectivity Standards Alliance does not grant you any license hereunder other | |
| than as expressly stated herein. | |
| Elements of this document may be subject to third party intellectual property | |
| rights, including without limitation, patent, copyright or trademark rights, | |
| and any such third party may or may not be a member of the Connectivity | |
| Standards Alliance. Connectivity Standards Alliance members grant other | |
| Connectivity Standards Alliance members certain intellectual property rights as | |
| set forth in the Connectivity Standards Alliance IPR Policy. Connectivity | |
| Standards Alliance members do not grant you any rights under this license. The | |
| Connectivity Standards Alliance is not responsible for, and shall not be held | |
| responsible in any manner for, identifying or failing to identify any or all | |
| such third party intellectual property rights. Please visit www.csa-iot.org for | |
| more information on how to become a member of the Connectivity Standards | |
| Alliance. | |
| This document and the information contained herein are provided on an “AS IS” | |
| basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS | |
| OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE | |
| INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING | |
| WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT | |
| OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS | |
| FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE | |
| CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF | |
| BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER | |
| DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL | |
| DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT | |
| OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH | |
| LOSS OR DAMAGE. | |
| All company, brand and product names in this document may be trademarks that | |
| are the sole property of their respective owners. | |
| This notice and disclaimer must be included on all copies of this document. | |
| Connectivity Standards Alliance | |
| 508 Second Street, Suite 206 | |
| Davis, CA 95616, USA | |
| :xrefstyle: basic | |
| --> | |
| <cluster xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="types types.xsd cluster cluster.xsd" id="0x0094" name="Water Heater Management Cluster" revision="2"> | |
| <revisionHistory> | |
| <revision revision="1" summary="Initial revision"/> | |
| <revision revision="2" summary="Added events and simplified data types"/> | |
| </revisionHistory> | |
| <clusterIds> | |
| <clusterId id="0x0094" name="Water Heater Management"/> | |
| </clusterIds> | |
| <classification hierarchy="base" role="application" picsCode="EWATERHTR" scope="Endpoint"/> | |
| <features> | |
| <feature bit="0" code="EM" name="EnergyManagement" summary="Allows energy management control of the tank"> | |
| <optionalConform/> | |
| </feature> | |
| <feature bit="1" code="TP" name="TankPercent" summary="Supports monitoring the percentage of hot water in the tank"> | |
| <optionalConform/> | |
| </feature> | |
| </features> | |
| <dataTypes> | |
| <enum name="BoostStateEnum"> | |
| <item value="0" name="Inactive" summary="Boost is not currently active"> | |
| <mandatoryConform/> | |
| </item> | |
| <item value="1" name="Active" summary="Boost is currently active"> | |
| <mandatoryConform/> | |
| </item> | |
| </enum> | |
| <bitmap name="WaterHeaterHeatSourceBitmap"> | |
| <bitfield name="ImmersionElement1" bit="0" summary="Immersion Heating Element 1"> | |
| <mandatoryConform/> | |
| </bitfield> | |
| <bitfield name="ImmersionElement2" bit="1" summary="Immersion Heating Element 2"> | |
| <mandatoryConform/> | |
| </bitfield> | |
| <bitfield name="HeatPump" bit="2" summary="Heat pump Heating"> | |
| <mandatoryConform/> | |
| </bitfield> | |
| <bitfield name="Boiler" bit="3" summary="Boiler Heating (e.g. Gas or Oil)"> | |
| <mandatoryConform/> | |
| </bitfield> | |
| <bitfield name="Other" bit="4" summary="Other Heating"> | |
| <mandatoryConform/> | |
| </bitfield> | |
| </bitmap> | |
| <struct name="WaterHeaterBoostInfoStruct"> | |
| <field id="0" name="Duration" type="elapsed-s"> | |
| <mandatoryConform/> | |
| <constraint> | |
| <min value="1"/> | |
| </constraint> | |
| </field> | |
| <field id="1" name="OneShot" type="bool" default="false"> | |
| <otherwiseConform> | |
| <optionalConform> | |
| <notTerm> | |
| <feature name="TP"/> | |
| </notTerm> | |
| </optionalConform> | |
| <optionalConform choice="a" max="1"> | |
| <feature name="TP"/> | |
| </optionalConform> | |
| </otherwiseConform> | |
| </field> | |
| <field id="2" name="EmergencyBoost" type="bool" default="false"> | |
| <optionalConform/> | |
| </field> | |
| <field id="3" name="TemporarySetpoint" type="temperature"> | |
| <optionalConform/> | |
| <constraint> | |
| <desc/> | |
| </constraint> | |
| </field> | |
| <field id="4" name="TargetPercentage" type="percent"> | |
| <otherwiseConform> | |
| <mandatoryConform> | |
| <field name="TargetReheat"/> | |
| </mandatoryConform> | |
| <optionalConform> | |
| <feature name="TP"/> | |
| </optionalConform> | |
| </otherwiseConform> | |
| </field> | |
| <field id="5" name="TargetReheat" type="percent"> | |
| <optionalConform choice="a" max="1"> | |
| <feature name="TP"/> | |
| </optionalConform> | |
| <constraint> | |
| <max> | |
| <field name="TargetPercentage"/> | |
| </max> | |
| </constraint> | |
| </field> | |
| </struct> | |
| </dataTypes> | |
| <attributes> | |
| <attribute id="0x0000" name="HeaterTypes" type="WaterHeaterHeatSourceBitmap"> | |
| <access read="true" readPrivilege="view"/> | |
| <quality persistence="fixed"/> | |
| <mandatoryConform/> | |
| </attribute> | |
| <attribute id="0x0001" name="HeatDemand" type="WaterHeaterHeatSourceBitmap"> | |
| <access read="true" readPrivilege="view"/> | |
| <mandatoryConform/> | |
| </attribute> | |
| <attribute id="0x0002" name="TankVolume" type="uint16"> | |
| <access read="true" readPrivilege="view"/> | |
| <mandatoryConform> | |
| <feature name="EM"/> | |
| </mandatoryConform> | |
| </attribute> | |
| <attribute id="0x0003" name="EstimatedHeatRequired" type="energy-mWh"> | |
| <access read="true" readPrivilege="view"/> | |
| <mandatoryConform> | |
| <feature name="EM"/> | |
| </mandatoryConform> | |
| <constraint> | |
| <min value="0"/> | |
| </constraint> | |
| </attribute> | |
| <attribute id="0x0004" name="TankPercentage" type="percent"> | |
| <access read="true" readPrivilege="view"/> | |
| <mandatoryConform> | |
| <feature name="TP"/> | |
| </mandatoryConform> | |
| </attribute> | |
| <attribute id="0x0005" name="BoostState" type="BoostStateEnum"> | |
| <access read="true" readPrivilege="view"/> | |
| <mandatoryConform/> | |
| </attribute> | |
| </attributes> | |
| <commands> | |
| <command id="0x00" name="Boost" direction="commandToServer" response="Y"> | |
| <access invokePrivilege="manage"/> | |
| <mandatoryConform/> | |
| <field id="0" name="BoostInfo" type="WaterHeaterBoostInfoStruct"> | |
| <mandatoryConform/> | |
| </field> | |
| </command> | |
| <command id="0x01" name="CancelBoost" direction="commandToServer" response="Y"> | |
| <access invokePrivilege="manage"/> | |
| <mandatoryConform/> | |
| </command> | |
| </commands> | |
| <events> | |
| <event id="0x00" name="BoostStarted" priority="info"> | |
| <access readPrivilege="view"/> | |
| <mandatoryConform/> | |
| <field id="0" name="BoostInfo" type="WaterHeaterBoostInfoStruct"> | |
| <mandatoryConform/> | |
| </field> | |
| </event> | |
| <event id="0x01" name="BoostEnded" priority="info"> | |
| <access readPrivilege="view"/> | |
| <mandatoryConform/> | |
| </event> | |
| </events> | |