| # Copyright (c) 2021 Project CHIP Authors |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| # Auto-generated scripts for harness use only, please review before automation. The endpoints and cluster names are currently set to default |
| |
| name: |
| 3.4.8. [TC-SC-4.8] Compressed Fabric ID remains the same for Nodes |
| commissioned to the same fabric [DUT - Commissioner] |
| |
| PICS: |
| - MCORE.ROLE.COMMISSIONER |
| |
| config: |
| nodeId: 0x12344321 |
| cluster: "Basic" |
| endpoint: 0 |
| |
| tests: |
| - label: "Commission TH1 to DUTs Fabric" |
| verification: | |
| 1. Provision the device using 1st controller chip-tool (as example commissioner) on the raspi (use above instructions) |
| |
| |
| ./chip-tool pairing onnetwork 2 20202021 |
| |
| |
| avahi-browse _matter._tcp -rt |
| |
| Verify on the TH Log: |
| |
| eth0 IPv6 8840D142C33AB653-0000000000000001 _matter._tcp local |
| disabled: true |
| |
| - label: "Commission TH2 to DUTs Fabric" |
| verification: | |
| Using your DUT Controller connect to the accessory. |
| |
| Below is the example when using chip tool as controller |
| |
| ./chip-tool pairing ble-wifi 1 chipsetup4 matter123 20202021 3841 |
| |
| |
| |
| Verify you got below message |
| Device commissioning completed with success |
| |
| |
| avahi-browse _matter._tcp -rt |
| |
| Verify on the TH Log: |
| |
| + eth0 IPv6 8840D142C33AB653-0000000000000001 _matter._tcp local |
| disabled: true |
| |
| - label: "Send RemoveFabric from DUT to TH1 and comission DUT to TH1 again" |
| verification: | |
| ./chip-tool operationalcredentials remove-fabric 1 1 0 |
| |
| Verify in TH all-clusters-app log |
| |
| |
| |
| CHIP:DMG: Received Command Response Data, Endpoint=0 Cluster=0x0000_003E Command=0x0000_0008 |
| [1651571274.154864][10562:10567] CHIP:TOO: Endpoint: 0 Cluster: 0x0000_003E Command 0x0000_0008 |
| [1651571274.155030][10562:10567] CHIP:TOO: NOCResponse: { |
| [1651571274.155102][10562:10567] CHIP:TOO: statusCode: 0 |
| [1651571274.155159][10562:10567] CHIP:TOO: fabricIndex: 1 |
| [1651571274.155215][10562:10567] CHIP:TOO: } |
| |
| |
| ./chip-tool pairing ble-wifi 1 chipsetup4 matter123 20202021 3841 |
| |
| avahi-browse _matter._tcp -rt |
| |
| Verify on the TH Log: |
| |
| + eth0 IPv6 8840D142C33AB653-0000000000000001 _matter._tcp local |
| disabled: true |
| |
| - label: "Send RemoveFabric from DUT to TH2 and comission DUT to TH2 again" |
| verification: | |
| ./chip-tool operationalcredentials remove-fabric 1 2 0 |
| |
| Verify in TH all-clusters-app log |
| |
| [1657628679275] [78509:912135] CHIP: [DMG] Received Command Response Data, Endpoint=0 Cluster=0x0000_003E Command=0x0000_0008 |
| [1657628679275] [78509:912135] CHIP: [TOO] Endpoint: 0 Cluster: 0x0000_003E Command 0x0000_0008 |
| [1657628679275] [78509:912135] CHIP: [TOO] NOCResponse: { |
| [1657628679275] [78509:912135] CHIP: [TOO] statusCode: 0 |
| [1657628679275] [78509:912135] CHIP: [TOO] fabricIndex: 1 |
| [1657628679275] [78509:912135] CHIP: [TOO] } |
| [1657628679275] [78509:912135] CHIP: [DMG] ICR mov |
| |
| ./chip-tool pairing ble-wifi 1 chipsetup4 matter123 20202021 3841 |
| |
| ./chip-tool pairing onnetwork 2 20202021 |
| |
| avahi-browse _matter._tcp -rt |
| |
| Verify on the TH Log: |
| |
| + eth0 IPv6 8840D142C33AB653-0000000000000002 |
| disabled: true |