| # Copyright (c) 2023 Project CHIP Authors |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| |
| name: 80.3.4. [TC-MOD-3.4] OnMode Overwriting StartUpMode (DUT as Server) |
| |
| PICS: |
| - MOD.S.A0004 |
| - MOD.S.A0005 |
| - OO.S.A4003 |
| |
| config: |
| nodeId: 0x12344321 |
| cluster: "Mode Select" |
| endpoint: 1 |
| #Configure newmode value |
| Step2dOnModeValue: |
| type: int8u |
| defaultValue: 4 |
| |
| tests: |
| - label: |
| "Step 0: Commission DUT to TH (can be skipped if done in a preceding |
| test)." |
| cluster: "DelayCommands" |
| command: "WaitForCommissionee" |
| arguments: |
| values: |
| - name: "nodeId" |
| value: nodeId |
| |
| - label: "Step 1: TH reads from the DUT the StartUpMode attribute." |
| PICS: MOD.S.A0004 |
| command: "readAttribute" |
| attribute: "StartUpMode" |
| response: |
| saveAs: startup_mode_dut |
| |
| - label: "Step 2a: TH reads from the DUT the OnMode attribute." |
| PICS: MOD.S.A0005 |
| command: "readAttribute" |
| attribute: "OnMode" |
| response: |
| saveAs: on_mode_dut |
| |
| - label: |
| "Step 2b: If the StartUpMode and OnMode attributes have the same |
| value, proceed to step 2c, Otherwise proceed to step 3." |
| PICS: MOD.S.A0004 && MOD.S.A0005 |
| cluster: "EqualityCommands" |
| command: "UnsignedNumberEquals" |
| arguments: |
| values: |
| - name: "Value1" |
| value: startup_mode_dut |
| - name: "Value2" |
| value: on_mode_dut |
| response: |
| - values: |
| - name: "Equals" |
| saveAs: IsExpectedValue |
| |
| - label: "Step 2c: TH reads the SupportedModes attribute from the DUT" |
| runIf: IsExpectedValue |
| PICS: MOD.S.A0002 |
| command: "readAttribute" |
| attribute: "SupportedModes" |
| response: |
| constraints: |
| type: list |
| |
| - label: |
| "Step 2d: Select a value from the list in step 2c with a different |
| value than the StartUpMode value read in step 1. TH sends a write |
| command for OnMode to the DUT with the selected value." |
| runIf: IsExpectedValue |
| PICS: MOD.S.A0002 && MOD.S.C00.Rsp |
| command: "writeAttribute" |
| attribute: "OnMode" |
| arguments: |
| value: Step2dOnModeValue |
| |
| - label: "Step 3: TH reads from the DUT the OnMode attribute." |
| PICS: MOD.S.A0005 && MOD.S.F00 |
| command: "readAttribute" |
| attribute: "OnMode" |
| response: |
| saveAs: Step3OnModeValue |
| |
| - label: |
| "Step 4: TH writes 1 to StartUpOnOff attribute of the OnOff Cluster of |
| the DUT" |
| PICS: OO.S.A4003 |
| cluster: "On/Off" |
| command: "writeAttribute" |
| attribute: "StartUpOnOff" |
| arguments: |
| value: 1 |
| |
| - label: "Step 5: Physically power cycle the device" |
| verification: | |
| Physically power cycle the device. |
| cluster: "LogCommands" |
| command: "UserPrompt" |
| PICS: PICS_USER_PROMPT |
| arguments: |
| values: |
| - name: "message" |
| value: "Please enter 'y' for success" |
| - name: "expectedValue" |
| value: "y" |
| |
| - label: "Wait for the commissioned device to be retrieved" |
| cluster: "DelayCommands" |
| command: "WaitForCommissionee" |
| arguments: |
| values: |
| - name: "nodeId" |
| value: nodeId |
| |
| - label: "Step 6: TH reads from the DUT the CurrentMode attribute." |
| PICS: MOD.S.A0003 && PICS_USER_PROMPT |
| command: "readAttribute" |
| attribute: "CurrentMode" |
| response: |
| value: Step3OnModeValue |