| #include "DeviceEnergyManagementDelegateImpl.h" |
| |
| #include <app-common/zap-generated/attributes/Accessors.h> |
| #include <app-common/zap-generated/cluster-objects.h> |
| #include <app/EventLogging.h> |
| |
| using namespace chip; |
| using namespace chip::app; |
| using namespace chip::app::Clusters; |
| using namespace chip::app::Clusters::DeviceEnergyManagement; |
| using namespace chip::app::Clusters::DeviceEnergyManagement::Attributes; |
| |
| using chip::Optional; |
| using namespace chip::app; |
| using CostsList = DataModel::List<const Structs::CostStruct::Type>; |
| |
| /** |
| * @brief Delegate handler for PowerAdjustRequest |
| * |
| * Note: checking of the validity of the PowerAdjustRequest has been done by the lower layer |
| * |
| * This function needs to notify the appliance that it should apply a new power setting. |
| * It should: |
| * 1) notify the appliance - if the appliance hardware cannot be adjusted, then return Failure |
| * 2) start a timer (or restart the existing PowerAdjust timer) for duration seconds |
| * 3) generate a PowerAdjustStart event (if there is not an existing PowerAdjustRequest running) |
| * 4) if appropriate, update the forecast with the new expected end time |
| * |
| * and when the timer expires: |
| * 5) notify the appliance's that it can resume its intended power setting (or go idle) |
| * 6) generate a PowerAdjustEnd event with cause NormalCompletion |
| * 7) if necessary, update the forecast with new expected end time |
| */ |
| Status DeviceEnergyManagementDelegate::PowerAdjustRequest(const int64_t power, const uint32_t duration, AdjustmentCauseEnum cause) |
| { |
| Status status = Status::UnsupportedCommand; // Status::Success; |
| |
| // TODO: implement |
| mEsaState = ESAStateEnum::kPowerAdjustActive; |
| |
| // TODO: Generate a PowerAdjustStart Event, then begins to adjust its power |
| // When done, raise PowerAdjustEnd & ESAState set to kOnline. |
| |
| MatterReportingAttributeChangeCallback(mEndpointId, DeviceEnergyManagement::Id, ESAState::Id); |
| |
| return status; |
| } |
| /** |
| * @brief Delegate handler for CancelPowerAdjustRequest |
| * |
| * Note: checking of the validity of the CancelPowerAdjustRequest has been done by the lower layer |
| * |
| * This function needs to notify the appliance that it should resume its intended power setting (or go idle). |
| |
| * It should: |
| * 1) notify the appliance's that it can resume its intended power setting (or go idle) |
| * 2) generate a PowerAdjustEnd event with cause code Cancelled |
| * 3) if necessary, update the forecast with new expected end time |
| */ |
| Status DeviceEnergyManagementDelegate::CancelPowerAdjustRequest() |
| { |
| Status status = Status::UnsupportedCommand; // Status::Success; |
| |
| // TODO: implement |
| /* TODO: If the command is accepted, the ESA SHALL generate an PowerAdjustEnd Event. */ |
| mEsaState = ESAStateEnum::kOnline; |
| MatterReportingAttributeChangeCallback(mEndpointId, DeviceEnergyManagement::Id, ESAState::Id); |
| |
| return status; |
| } |
| |
| /** |
| * @brief Delegate handler for StartTimeAdjustRequest |
| * |
| * Note: checking of the validity of the StartTimeAdjustRequest has been done by the lower layer |
| * |
| * This function needs to notify the appliance that the forecast has been updated by a client. |
| * |
| * It should: |
| * 1) update the forecast attribute with the revised start time |
| * 2) send a callback notification to the appliance so it can refresh its internal schedule |
| */ |
| Status DeviceEnergyManagementDelegate::StartTimeAdjustRequest(const uint32_t requestedStartTime, AdjustmentCauseEnum cause) |
| { |
| DataModel::Nullable<Structs::ForecastStruct::Type> forecast = GetForecast(); |
| |
| if (forecast.IsNull()) |
| { |
| return Status::Failure; |
| } |
| |
| uint32_t duration = forecast.Value().endTime - forecast.Value().startTime; // the current entire forecast duration |
| |
| /* Modify start time and end time */ |
| forecast.Value().startTime = requestedStartTime; |
| forecast.Value().endTime = requestedStartTime + duration; |
| |
| SetForecast(forecast); // This will increment forecast ID |
| |
| // TODO: callback to the appliance to notify it of a new start time |
| |
| return Status::Success; |
| } |
| /** |
| * @brief Delegate handler for Pause Request |
| * |
| * Note: checking of the validity of the Pause Request has been done by the lower layer |
| * |
| * This function needs to notify the appliance that it should now pause. |
| * It should: |
| * 1) pause the appliance - if the appliance hardware cannot be paused, then return Failure |
| * 2) start a timer for duration seconds |
| * 3) generate a Paused event |
| * 4) update the forecast with the new expected end time |
| * |
| * and when the timer expires: |
| * 5) restore the appliance's operational state |
| * 6) generate a Resumed event |
| * 7) if necessary, update the forecast with new expected end time |
| */ |
| Status DeviceEnergyManagementDelegate::PauseRequest(const uint32_t duration, AdjustmentCauseEnum cause) |
| { |
| Status status = Status::UnsupportedCommand; // Status::Success; |
| // TODO: implement the behaviour above |
| return status; |
| } |
| |
| /** |
| * @brief Delegate handler for ResumeRequest |
| * |
| * Note: checking of the validity of the ResumeRequest has been done by the lower layer |
| * |
| * This function needs to notify the appliance that it should now resume operation |
| * |
| * It should: |
| * 1) restore the appliance's operational state |
| * 2) generate a Resumed event |
| * 3) update the forecast with new expected end time (given that the pause duration was shorter than originally requested) |
| * |
| */ |
| Status DeviceEnergyManagementDelegate::ResumeRequest() |
| { |
| Status status = Status::UnsupportedCommand; // Status::Success; |
| |
| // TODO: implement the behaviour above |
| SetESAState(ESAStateEnum::kOnline); |
| |
| return status; |
| } |
| |
| /** |
| * @brief Delegate handler for ModifyForecastRequest |
| * |
| * Note: Only basic checking of the validity of the ModifyForecastRequest has been |
| * done by the lower layer. This is a more complex use-case and requires higher-level |
| * work by the delegate. |
| * |
| * It should: |
| * 1) determine if the new forecast adjustments are acceptable to the appliance |
| * - if not return Failure. For example, if it may cause the home to be too hot |
| * or too cold, or a battery to be insufficiently charged |
| * 2) if the slot adjustments are acceptable, then update the forecast |
| * 3) notify the appliance to follow the revised schedule |
| */ |
| Status DeviceEnergyManagementDelegate::ModifyForecastRequest( |
| const uint32_t forecastId, const DataModel::DecodableList<Structs::SlotAdjustmentStruct::DecodableType> & slotAdjustments, |
| AdjustmentCauseEnum cause) |
| { |
| Status status = Status::UnsupportedCommand; // Status::Success; |
| |
| // TODO: implement the behaviour above |
| return status; |
| } |
| |
| /** |
| * @brief Delegate handler for RequestConstraintBasedForecast |
| * |
| * Note: Only basic checking of the validity of the RequestConstraintBasedForecast has been |
| * done by the lower layer. This is a more complex use-case and requires higher-level |
| * work by the delegate. |
| * |
| * It should: |
| * 1) perform a higher level optimization (e.g. using tariff information, and user preferences) |
| * 2) if a solution can be found, then update the forecast, else return Failure |
| * 3) notify the appliance to follow the revised schedule |
| */ |
| Status DeviceEnergyManagementDelegate::RequestConstraintBasedForecast( |
| const DataModel::DecodableList<Structs::ConstraintsStruct::DecodableType> & constraints, AdjustmentCauseEnum cause) |
| { |
| Status status = Status::UnsupportedCommand; // Status::Success; |
| // TODO: implement the behaviour above |
| return status; |
| } |
| |
| /** |
| * @brief Delegate handler for CancelRequest |
| * |
| * Note: This is a more complex use-case and requires higher-level work by the delegate. |
| * |
| * It SHALL: |
| * 1) Check if the forecastUpdateReason was already InternalOptimization (and reject the command) |
| * 2) Update its forecast (based on its optimization strategy) ignoring previous requests |
| * 3) Update its Forecast attribute to match its new intended operation, and update the |
| * ForecastStruct.ForecastUpdateReason to `Internal Optimization`. |
| */ |
| Status DeviceEnergyManagementDelegate::CancelRequest() |
| { |
| Status status = Status::UnsupportedCommand; // Status::Success; |
| // TODO: implement the behaviour above |
| return status; |
| } |
| |
| // ------------------------------------------------------------------ |
| // Get attribute methods |
| ESATypeEnum DeviceEnergyManagementDelegate::GetESAType() |
| { |
| return mEsaType; |
| } |
| |
| bool DeviceEnergyManagementDelegate::GetESACanGenerate() |
| { |
| return mEsaCanGenerate; |
| } |
| |
| ESAStateEnum DeviceEnergyManagementDelegate::GetESAState() |
| { |
| return mEsaState; |
| } |
| |
| int64_t DeviceEnergyManagementDelegate::GetAbsMinPower() |
| { |
| return mAbsMinPower; |
| } |
| |
| int64_t DeviceEnergyManagementDelegate::GetAbsMaxPower() |
| { |
| return mAbsMaxPower; |
| } |
| |
| PowerAdjustmentCapability::TypeInfo::Type DeviceEnergyManagementDelegate::GetPowerAdjustmentCapability() |
| { |
| return mPowerAdjustmentCapability; |
| } |
| |
| DataModel::Nullable<Structs::ForecastStruct::Type> DeviceEnergyManagementDelegate::GetForecast() |
| { |
| return mForecast; |
| } |
| |
| OptOutStateEnum DeviceEnergyManagementDelegate::GetOptOutState() |
| { |
| return mOptOutState; |
| } |
| |
| // ------------------------------------------------------------------ |
| // Set attribute methods |
| |
| CHIP_ERROR DeviceEnergyManagementDelegate::SetESAType(ESATypeEnum newValue) |
| { |
| ESATypeEnum oldValue = mEsaType; |
| |
| if (newValue >= ESATypeEnum::kUnknownEnumValue) |
| { |
| return CHIP_IM_GLOBAL_STATUS(ConstraintError); |
| } |
| |
| mEsaType = newValue; |
| if (oldValue != newValue) |
| { |
| ChipLogDetail(AppServer, "mEsaType updated to %d", static_cast<int>(mEsaType)); |
| MatterReportingAttributeChangeCallback(mEndpointId, DeviceEnergyManagement::Id, ESAType::Id); |
| } |
| |
| return CHIP_NO_ERROR; |
| } |
| |
| CHIP_ERROR DeviceEnergyManagementDelegate::SetESACanGenerate(bool newValue) |
| { |
| bool oldValue = mEsaCanGenerate; |
| |
| mEsaCanGenerate = newValue; |
| if (oldValue != newValue) |
| { |
| ChipLogDetail(AppServer, "mEsaCanGenerate updated to %d", static_cast<int>(mEsaCanGenerate)); |
| MatterReportingAttributeChangeCallback(mEndpointId, DeviceEnergyManagement::Id, ESACanGenerate::Id); |
| } |
| |
| return CHIP_NO_ERROR; |
| } |
| |
| CHIP_ERROR DeviceEnergyManagementDelegate::SetESAState(ESAStateEnum newValue) |
| { |
| ESAStateEnum oldValue = mEsaState; |
| |
| if (newValue >= ESAStateEnum::kUnknownEnumValue) |
| { |
| return CHIP_IM_GLOBAL_STATUS(ConstraintError); |
| } |
| |
| mEsaState = newValue; |
| if (oldValue != newValue) |
| { |
| ChipLogDetail(AppServer, "mEsaState updated to %d", static_cast<int>(mEsaState)); |
| MatterReportingAttributeChangeCallback(mEndpointId, DeviceEnergyManagement::Id, ESAState::Id); |
| } |
| |
| return CHIP_NO_ERROR; |
| } |
| |
| CHIP_ERROR DeviceEnergyManagementDelegate::SetAbsMinPower(int64_t newValue) |
| { |
| int64_t oldValue = mAbsMinPower; |
| |
| mAbsMinPower = newValue; |
| if (oldValue != newValue) |
| { |
| ChipLogDetail(AppServer, "mAbsMinPower updated to %d", static_cast<int>(mAbsMinPower)); |
| MatterReportingAttributeChangeCallback(mEndpointId, DeviceEnergyManagement::Id, AbsMinPower::Id); |
| } |
| |
| return CHIP_NO_ERROR; |
| } |
| |
| CHIP_ERROR DeviceEnergyManagementDelegate::SetAbsMaxPower(int64_t newValue) |
| { |
| int64_t oldValue = mAbsMaxPower; |
| |
| mAbsMaxPower = newValue; |
| if (oldValue != newValue) |
| { |
| ChipLogDetail(AppServer, "mAbsMaxPower updated to %d", static_cast<int>(mAbsMaxPower)); |
| MatterReportingAttributeChangeCallback(mEndpointId, DeviceEnergyManagement::Id, AbsMaxPower::Id); |
| } |
| |
| return CHIP_NO_ERROR; |
| } |
| |
| CHIP_ERROR |
| DeviceEnergyManagementDelegate::SetPowerAdjustmentCapability(PowerAdjustmentCapability::TypeInfo::Type powerAdjustmentCapability) |
| { |
| // TODO see Issue #31147 |
| return CHIP_NO_ERROR; |
| } |
| |
| CHIP_ERROR DeviceEnergyManagementDelegate::SetForecast(DataModel::Nullable<Structs::ForecastStruct::Type> forecast) |
| { |
| // TODO see Issue #31147 |
| |
| return CHIP_NO_ERROR; |
| } |