blob: 6d6477cc72fb7c1a24eb5a27d85425022efbaead [file] [log] [blame]
<?xml version="1.0"?>
<!--
Copyright (C) Connectivity Standards Alliance (2023). All rights reserved.
The information within this document is the property of the Connectivity
Standards Alliance and its use and disclosure are restricted, except as
expressly set forth herein.
Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive,
nontransferable, worldwide, limited and revocable license (without the right to
sublicense), under Connectivity Standards Alliance's applicable copyright
rights, to view, download, save, reproduce and use the document solely for your
own internal purposes and in accordance with the terms of the license set forth
herein. This license does not authorize you to, and you expressly warrant that
you shall not: (a) permit others (outside your organization) to use this
document; (b) post or publish this document; (c) modify, adapt, translate, or
otherwise change this document in any manner or create any derivative work
based on this document; (d) remove or modify any notice or label on this
document, including this Copyright Notice, License and Disclaimer. The
Connectivity Standards Alliance does not grant you any license hereunder other
than as expressly stated herein.
Elements of this document may be subject to third party intellectual property
rights, including without limitation, patent, copyright or trademark rights,
and any such third party may or may not be a member of the Connectivity
Standards Alliance. Connectivity Standards Alliance members grant other
Connectivity Standards Alliance members certain intellectual property rights as
set forth in the Connectivity Standards Alliance IPR Policy. Connectivity
Standards Alliance members do not grant you any rights under this license. The
Connectivity Standards Alliance is not responsible for, and shall not be held
responsible in any manner for, identifying or failing to identify any or all
such third party intellectual property rights. Please visit www.csa-iot.org for
more information on how to become a member of the Connectivity Standards
Alliance.
This document and the information contained herein are provided on an “AS IS”
basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS
OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE
INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING
WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT
OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS
FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE
CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF
BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER
DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL
DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT
OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
LOSS OR DAMAGE.
All company, brand and product names in this document may be trademarks that
are the sole property of their respective owners.
This notice and disclaimer must be included on all copies of this document.
Connectivity Standards Alliance
508 Second Street, Suite 206
Davis, CA 95616, USA
-->
<cluster xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="types types.xsd cluster cluster.xsd" id="0x0098" name="Device Energy Management" revision="3">
<revisionHistory>
<revision revision="1" summary="Initial Release"/>
<revision revision="2" summary="Updates after 0.7 Ballot review"/>
<revision revision="3" summary="Updates to match cluster spec updates"/>
</revisionHistory>
<classification hierarchy="base" role="application" picsCode="DEM" scope="Endpoint"/>
<features>
<feature bit="0" code="PA" name="PowerAdjustment" summary="Allows an EMS to make a temporary power
adjustment (within the limits offered by the ESA).">
<optionalConform choice="a" more="true"/>
</feature>
<feature bit="1" code="PFR" name="PowerForecastReporting" summary="Allows an ESA to advertise its indicative
future power consumption vs time.">
<otherwiseConform>
<mandatoryConform>
<andTerm>
<orTerm>
<feature name="STA"/>
<feature name="PAU"/>
<feature name="FA"/>
<feature name="CON"/>
</orTerm>
<notTerm>
<feature name="SFR"/>
</notTerm>
</andTerm>
</mandatoryConform>
<optionalConform choice="a" more="true"/>
</otherwiseConform>
</feature>
<feature bit="2" code="SFR" name="StateForecastReporting" summary="Allows an ESA to advertise its indicative
future state vs time.">
<otherwiseConform>
<mandatoryConform>
<andTerm>
<orTerm>
<feature name="STA"/>
<feature name="PAU"/>
<feature name="FA"/>
<feature name="CON"/>
</orTerm>
<notTerm>
<feature name="PFR"/>
</notTerm>
</andTerm>
</mandatoryConform>
<optionalConform choice="a" more="true"/>
</otherwiseConform>
</feature>
<feature bit="3" code="STA" name="StartTimeAdjustment" summary="Allows an EMS to delay an ESA's
planned operation.">
<optionalConform choice="a" more="true"/>
</feature>
<feature bit="4" code="PAU" name="Pausable" summary="Allows an EMS to pause an ESA's
planned operation.">
<optionalConform choice="a" more="true"/>
</feature>
<feature bit="5" code="FA" name="ForecastAdjustment" summary="Allows an EMS to adjust an ESA's
planned operation.">
<otherwiseConform>
<provisionalConform/>
<optionalConform choice="a" more="true"/>
</otherwiseConform>
</feature>
<feature bit="6" code="CON" name="ConstraintBasedAdjustment" summary="Allows an EMS to request constraints to an ESA's
planned operation.">
<otherwiseConform>
<provisionalConform/>
<optionalConform choice="a" more="true"/>
</otherwiseConform>
</feature>
</features>
<dataTypes>
<enum name="AdjustmentCauseEnum">
<item value="0" name="Local" summary="The adjustment is to optimize the local energy usage">
<optionalConform/>
</item>
<item value="1" name="Grid" summary="The adjustment is to optimize the grid energy usage">
<optionalConform/>
</item>
</enum>
<enum name="CauseEnum">
<item value="0" name="NormalCompletion" summary="The ESA completed the power adjustment as requested">
<optionalConform/>
</item>
<item value="1" name="Offline" summary="The ESA was set to offline">
<optionalConform/>
</item>
<item value="2" name="Fault" summary="The ESA has developed a fault could not complete the adjustment">
<optionalConform/>
</item>
<item value="3" name="UserOptOut" summary="The user has disabled the ESA's flexibility capability">
<optionalConform/>
</item>
<item value="4" name="Cancelled" summary="The adjustment was cancelled by a client">
<optionalConform/>
</item>
</enum>
<enum name="CostTypeEnum">
<item value="0" name="Financial" summary="Financial cost">
<mandatoryConform/>
</item>
<item value="1" name="GHGEmissions" summary="Grid CO2e grams cost">
<mandatoryConform/>
</item>
<item value="2" name="Comfort" summary="Consumer comfort impact cost">
<mandatoryConform/>
</item>
<item value="3" name="Temperature" summary="Temperature impact cost">
<mandatoryConform/>
</item>
</enum>
<enum name="ESAStateEnum">
<item value="0" name="Offline" summary="The ESA is not available to the EMS (e.g. start-up, maintenance mode)">
<mandatoryConform/>
</item>
<item value="1" name="Online" summary="The ESA is working normally and can be controlled by the EMS">
<mandatoryConform/>
</item>
<item value="2" name="Fault" summary="The ESA has developed a fault and cannot provide service">
<mandatoryConform/>
</item>
<item value="3" name="PowerAdjustActive" summary="The ESA is in the middle of a power adjustment event">
<mandatoryConform>
<feature name="PA"/>
</mandatoryConform>
</item>
<item value="4" name="Paused" summary="The ESA is currently paused by a client using the PauseRequest command">
<optionalConform>
<feature name="FA"/>
</optionalConform>
</item>
</enum>
<enum name="ESATypeEnum">
<item value="0" name="EVSE" summary="EV Supply Equipment">
<optionalConform/>
</item>
<item value="1" name="SpaceHeating" summary="Space heating appliance">
<optionalConform/>
</item>
<item value="2" name="WaterHeating" summary="Water heating appliance">
<optionalConform/>
</item>
<item value="3" name="SpaceCooling" summary="Space cooling appliance">
<optionalConform/>
</item>
<item value="4" name="SpaceHeatingCooling" summary="Space heating and cooling appliance">
<optionalConform/>
</item>
<item value="5" name="BatteryStorage" summary="Battery Electric Storage System">
<optionalConform/>
</item>
<item value="6" name="SolarPV" summary="Solar PV inverter">
<optionalConform/>
</item>
<item value="7" name="FridgeFreezer" summary="Fridge / Freezer">
<optionalConform/>
</item>
<item value="8" name="WashingMachine" summary="Washing Machine">
<optionalConform/>
</item>
<item value="9" name="Dishwasher" summary="Dishwasher">
<optionalConform/>
</item>
<item value="10" name="Cooking" summary="Cooking appliance">
<optionalConform/>
</item>
<item value="11" name="HomeWaterPump" summary="Home water pump (e.g. drinking well)">
<optionalConform/>
</item>
<item value="12" name="IrrigationWaterPump" summary="Irrigation water pump">
<optionalConform/>
</item>
<item value="13" name="PoolPump" summary="Pool pump">
<optionalConform/>
</item>
<item value="255" name="Other" summary="Other appliance type">
<optionalConform/>
</item>
</enum>
<enum name="ForecastUpdateReasonEnum">
<item value="0" name="Internal" summary="The update was due to internal ESA device optimization">
<optionalConform/>
</item>
<item value="1" name="Local" summary="The update was due to local EMS optimization">
<optionalConform/>
</item>
<item value="2" name="Grid" summary="The update was due to grid optimization">
<optionalConform/>
</item>
</enum>
<enum name="OptOutStateEnum">
<item value="0" name="NoOptOut" summary="The user has not opted out of either local or grid optimizations">
<mandatoryConform/>
</item>
<item value="1" name="LocalOptOut" summary="The user has opted out of local EMS optimizations only">
<mandatoryConform/>
</item>
<item value="2" name="GridOptOut" summary="The user has opted out of grid EMS optimizations only">
<mandatoryConform/>
</item>
<item value="3" name="OptOut" summary="The user has opted out of all optimizations">
<mandatoryConform/>
</item>
</enum>
<struct name="ConstraintsStruct">
<field id="0" name="StartTime" type="epoch-s">
<access read="true" write="true"/>
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="1" name="Duration" type="elapsed-s">
<access read="true" write="true"/>
<mandatoryConform/>
<constraint type="between" from="0" to="86400"/>
</field>
<field id="2" name="NominalPower" type="power-mW">
<access read="true" write="true"/>
<mandatoryConform>
<feature name="PFR"/>
</mandatoryConform>
<constraint type="desc"/>
</field>
<field id="3" name="MaximumEnergy" type="energy-mWh">
<access read="true" write="true"/>
<mandatoryConform>
<feature name="PFR"/>
</mandatoryConform>
</field>
<field id="4" name="LoadControl" type="int8">
<access read="true" write="true"/>
<mandatoryConform>
<feature name="SFR"/>
</mandatoryConform>
</field>
</struct>
<struct name="CostStruct">
<field id="0" name="CostType" type="CostTypeEnum" default="0">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="1" name="Value" type="int32" default="0">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="2" name="DecimalPoints" type="uint8" default="0">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="3" name="Currency" type="uint16" default="0">
<access read="true"/>
<optionalConform/>
<constraint type="max" value="999"/>
</field>
</struct>
<struct name="ForecastStruct">
<field id="0" name="ForecastId" type="uint16" default="0">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="1" name="ActiveSlotNumber" type="uint16" default="0">
<access read="true"/>
<quality nullable="true"/>
<mandatoryConform/>
</field>
<field id="2" name="StartTime" type="epoch-s">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="3" name="EndTime" type="epoch-s">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="4" name="EarliestStartTime" type="epoch-s">
<access read="true"/>
<quality nullable="true"/>
<mandatoryConform>
<feature name="STA"/>
</mandatoryConform>
</field>
<field id="5" name="LatestEndTime" type="epoch-s">
<access read="true"/>
<mandatoryConform>
<feature name="STA"/>
</mandatoryConform>
</field>
<field id="6" name="IsPauseable" type="bool">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="7" name="Slots" type="list">
<entry type="SlotStruct"/>
<access read="true"/>
<mandatoryConform/>
<constraint type="maxCount" value="10"/>
</field>
<field id="8" name="ForecastUpdateReason" type="ForecastUpdateReasonEnum">
<access read="true"/>
<mandatoryConform/>
</field>
</struct>
<struct name="PowerAdjustStruct">
<field id="0" name="MinPower" type="power-mW" default="0">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="1" name="MaxPower" type="power-mW" default="0">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="2" name="MinDuration" type="elapsed-s" default="0">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="3" name="MaxDuration" type="elapsed-s">
<access read="true"/>
<mandatoryConform/>
</field>
</struct>
<struct name="SlotAdjustmentStruct">
<field id="0" name="SlotIndex" type="uint8">
<access read="true" write="true"/>
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="1" name="NominalPower" type="power-mW">
<access read="true" write="true"/>
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="2" name="Duration" type="elapsed-s">
<access read="true" write="true"/>
<mandatoryConform/>
<constraint type="desc"/>
</field>
</struct>
<struct name="SlotStruct">
<field id="0" name="MinDuration" type="elapsed-s">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="1" name="MaxDuration" type="elapsed-s">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="2" name="DefaultDuration" type="elapsed-s">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="3" name="ElapsedSlotTime" type="elapsed-s">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="4" name="RemainingSlotTime" type="elapsed-s">
<access read="true"/>
<mandatoryConform/>
</field>
<field id="5" name="SlotIsPauseable" type="bool">
<access read="true"/>
<mandatoryConform>
<feature name="PAU"/>
</mandatoryConform>
</field>
<field id="6" name="MinPauseDuration" type="elapsed-s">
<access read="true"/>
<mandatoryConform>
<feature name="PAU"/>
</mandatoryConform>
</field>
<field id="7" name="MaxPauseDuration" type="elapsed-s">
<access read="true"/>
<mandatoryConform>
<feature name="PAU"/>
</mandatoryConform>
</field>
<field id="8" name="ManufacturerESAState" type="uint16">
<access read="true"/>
<mandatoryConform>
<feature name="SFR"/>
</mandatoryConform>
</field>
<field id="9" name="NominalPower" type="power-mW">
<access read="true"/>
<mandatoryConform>
<feature name="PFR"/>
</mandatoryConform>
</field>
<field id="10" name="MinPower" type="power-mW">
<access read="true"/>
<mandatoryConform>
<feature name="PFR"/>
</mandatoryConform>
</field>
<field id="11" name="MaxPower" type="power-mW">
<access read="true"/>
<mandatoryConform>
<feature name="PFR"/>
</mandatoryConform>
</field>
<field id="12" name="NominalEnergy" type="energy-mWh">
<access read="true"/>
<mandatoryConform>
<feature name="PFR"/>
</mandatoryConform>
</field>
<field id="13" name="Costs" type="list">
<entry type="CostStruct"/>
<access read="true"/>
<optionalConform/>
<constraint type="maxCount" value="5"/>
</field>
<field id="14" name="MinPowerAdjustment" type="power-mW">
<access read="true"/>
<mandatoryConform>
<andTerm>
<feature name="FA"/>
<feature name="PFR"/>
</andTerm>
</mandatoryConform>
</field>
<field id="15" name="MaxPowerAdjustment" type="power-mW">
<access read="true"/>
<mandatoryConform>
<andTerm>
<feature name="FA"/>
<feature name="PFR"/>
</andTerm>
</mandatoryConform>
</field>
<field id="16" name="MinDurationAdjustment" type="elapsed-s">
<access read="true"/>
<mandatoryConform>
<andTerm>
<feature name="FA"/>
<orTerm>
<feature name="PFR"/>
<feature name="SFR"/>
</orTerm>
</andTerm>
</mandatoryConform>
</field>
<field id="17" name="MaxDurationAdjustment" type="elapsed-s">
<access read="true"/>
<mandatoryConform>
<andTerm>
<feature name="FA"/>
<orTerm>
<feature name="PFR"/>
<feature name="SFR"/>
</orTerm>
</andTerm>
</mandatoryConform>
</field>
</struct>
</dataTypes>
<commands>
<command id="0x00" name="PowerAdjustRequest" response="Y">
<access invokePrivilege="operate"/>
<mandatoryConform>
<feature name="PA"/>
</mandatoryConform>
<field id="0" name="Power" type="power-mW">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="1" name="Duration" type="elapsed-s">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="2" name="Cause" type="AdjustmentCauseEnum">
<mandatoryConform/>
<constraint type="desc"/>
</field>
</command>
<command id="0x01" name="CancelPowerAdjustRequest" response="Y">
<access invokePrivilege="operate"/>
<mandatoryConform>
<feature name="PA"/>
</mandatoryConform>
</command>
<command id="0x02" name="StartTimeAdjustRequest" response="Y">
<access invokePrivilege="operate"/>
<mandatoryConform>
<feature name="STA"/>
</mandatoryConform>
<field id="0" name="RequestedStartTime" type="epoch-s">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="1" name="Cause" type="AdjustmentCauseEnum">
<mandatoryConform/>
<constraint type="desc"/>
</field>
</command>
<command id="0x03" name="PauseRequest" response="Y">
<access invokePrivilege="operate"/>
<mandatoryConform>
<feature name="PAU"/>
</mandatoryConform>
<field id="0" name="Duration" type="elapsed-s">
<mandatoryConform/>
<constraint type="desc"/>
</field>
<field id="1" name="Cause" type="AdjustmentCauseEnum">
<mandatoryConform/>
<constraint type="desc"/>
</field>
</command>
<command id="0x04" name="ResumeRequest" response="Y">
<access invokePrivilege="operate"/>
<mandatoryConform>
<feature name="PAU"/>
</mandatoryConform>
</command>
<command id="0x05" name="ModifyForecastRequest" response="Y">
<access invokePrivilege="operate"/>
<mandatoryConform>
<feature name="FA"/>
</mandatoryConform>
<field id="0" name="ForecastId" type="uint32">
<mandatoryConform/>
</field>
<field id="1" name="SlotAdjustments" type="list">
<entry type="SlotAdjustmentStruct"/>
<mandatoryConform/>
<constraint type="maxCount" value="10"/>
</field>
<field id="2" name="Cause" type="AdjustmentCauseEnum">
<mandatoryConform/>
<constraint type="desc"/>
</field>
</command>
<command id="0x06" name="RequestConstraintBasedForecast" response="Y">
<access invokePrivilege="operate"/>
<mandatoryConform>
<feature name="CON"/>
</mandatoryConform>
<field id="0" name="Constraints" type="list">
<entry type="ConstraintsStruct"/>
<mandatoryConform/>
<constraint type="maxCount" value="10"/>
</field>
<field id="1" name="Cause" type="AdjustmentCauseEnum">
<mandatoryConform/>
<constraint type="desc"/>
</field>
</command>
<command id="0x07" name="CancelRequest" response="Y">
<access invokePrivilege="operate"/>
<mandatoryConform>
<orTerm>
<feature name="STA"/>
<feature name="FA"/>
<feature name="CON"/>
</orTerm>
</mandatoryConform>
</command>
</commands>
<events>
<event id="0x00" name="PowerAdjustStart" priority="info">
<access readPrivilege="view"/>
<mandatoryConform>
<feature name="PA"/>
</mandatoryConform>
</event>
<event id="0x01" name="PowerAdjustEnd" priority="info">
<access readPrivilege="view"/>
<mandatoryConform>
<feature name="PA"/>
</mandatoryConform>
<field id="0" name="Cause" type="CauseEnum" default="NormalCompletion">
<mandatoryConform/>
</field>
<field id="1" name="Duration" type="elapsed-s">
<mandatoryConform/>
</field>
<field id="2" name="EnergyUse" type="energy-mWh">
<mandatoryConform/>
</field>
</event>
<event id="0x02" name="Paused" priority="info">
<access readPrivilege="view"/>
<mandatoryConform>
<feature name="PAU"/>
</mandatoryConform>
</event>
<event id="0x03" name="Resumed" priority="info">
<access readPrivilege="view"/>
<mandatoryConform>
<feature name="PAU"/>
</mandatoryConform>
<field id="0" name="Cause" type="CauseEnum" default="NormalCompletion">
<mandatoryConform/>
</field>
</event>
</events>
</cluster>