| * Copyright (c) 2025 Project CHIP Authors |
| * All rights reserved. |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| |
| #include <app/clusters/meter-identification-server/MeterIdentificationTestEventTriggerHandler.h> |
| #include <meter-identification-instance.h> |
| |
| using namespace chip; |
| using namespace chip::app; |
| using namespace chip::app::Clusters; |
| using namespace chip::app::Clusters::MeterIdentification; |
| |
| namespace { |
| |
| class OldMeterIdentificationAttributes |
| { |
| private: |
| Instance * mInstance = nullptr; |
| static constexpr size_t kMaximumStringSize = 64; |
| char mPointOfDeliveryBuf[kMaximumStringSize] = {}; |
| char mMeterSerialNumberBuf[kMaximumStringSize] = {}; |
| char mProtocolVersionBuf[kMaximumStringSize] = {}; |
| DataModel::Nullable<MeterTypeEnum> mMeterType; |
| DataModel::Nullable<CharSpan> mPointOfDelivery; |
| DataModel::Nullable<CharSpan> mMeterSerialNumber; |
| DataModel::Nullable<CharSpan> mProtocolVersion; |
| DataModel::Nullable<Globals::Structs::PowerThresholdStruct::Type> mPowerThreshold; |
| |
| struct DataPresets_s |
| { |
| DataModel::Nullable<MeterTypeEnum> meterType; |
| DataModel::Nullable<CharSpan> pointOfDelivery; |
| DataModel::Nullable<CharSpan> meterSerialNumber; |
| DataModel::Nullable<CharSpan> protocolVersion; |
| DataModel::Nullable<Globals::Structs::PowerThresholdStruct::Type> powerThreshold; |
| }; |
| |
| static constexpr uint8_t kMaxPresetItems = 2u; |
| uint8_t mPresetsIdx; |
| |
| const DataPresets_s TestsDataPresets[kMaxPresetItems] = { |
| { .meterType = DataModel::MakeNullable(MeterTypeEnum::kUtility), |
| .pointOfDelivery = DataModel::MakeNullable(CharSpan::fromCharString("Test delivery point")), |
| .meterSerialNumber = DataModel::MakeNullable(CharSpan::fromCharString("TST-123456789")), |
| .protocolVersion = DataModel::MakeNullable(CharSpan::fromCharString("1.2.3")), |
| .powerThreshold = DataModel::MakeNullable(Globals::Structs::PowerThresholdStruct::Type( |
| { Optional<int64_t>(2400000), Optional<int64_t>(120), Globals::PowerThresholdSourceEnum::kContract })) }, |
| { .meterType = DataModel::MakeNullable(MeterTypeEnum::kPrivate), |
| .pointOfDelivery = DataModel::MakeNullable(CharSpan::fromCharString("New delivery point")), |
| .meterSerialNumber = DataModel::MakeNullable(CharSpan::fromCharString("NEW-987654321")), |
| .protocolVersion = DataModel::MakeNullable(CharSpan::fromCharString("3.4.5")), |
| .powerThreshold = DataModel::MakeNullable(Globals::Structs::PowerThresholdStruct::Type( |
| { Optional<int64_t>(4800000), Optional<int64_t>(240), Globals::PowerThresholdSourceEnum::kRegulator })) } |
| }; |
| |
| static bool NullableCharSpansEqual(const DataModel::Nullable<CharSpan> & a, const DataModel::Nullable<CharSpan> & b) |
| { |
| if (a.IsNull() && b.IsNull()) |
| { |
| return true; |
| } |
| |
| if (!a.IsNull() && !b.IsNull()) |
| { |
| return a.Value().data_equal(b.Value()); |
| } |
| |
| return false; |
| } |
| |
| void SavePointOfDelivery(const DataModel::Nullable<CharSpan> & newValue) |
| { |
| if (NullableCharSpansEqual(newValue, mPointOfDelivery)) |
| { |
| return; |
| } |
| |
| if (!mPointOfDelivery.IsNull()) |
| { |
| mPointOfDelivery.SetNull(); |
| } |
| |
| if (!newValue.IsNull()) |
| { |
| const size_t len = newValue.IsNull() ? 0 |
| : newValue.Value().size() < kMaximumStringSize ? newValue.Value().size() |
| : kMaximumStringSize; |
| memmove(mPointOfDeliveryBuf, newValue.Value().data(), len); |
| mPointOfDelivery = DataModel::MakeNullable(CharSpan(mPointOfDeliveryBuf, len)); |
| } |
| } |
| |
| void SaveMeterSerialNumber(const DataModel::Nullable<CharSpan> & newValue) |
| { |
| if (NullableCharSpansEqual(newValue, mMeterSerialNumber)) |
| { |
| return; |
| } |
| |
| if (!mMeterSerialNumber.IsNull()) |
| { |
| mMeterSerialNumber.SetNull(); |
| } |
| |
| if (!newValue.IsNull()) |
| { |
| const size_t len = newValue.IsNull() ? 0 |
| : newValue.Value().size() < kMaximumStringSize ? newValue.Value().size() |
| : kMaximumStringSize; |
| memmove(mMeterSerialNumberBuf, newValue.Value().data(), len); |
| mMeterSerialNumber = DataModel::MakeNullable(CharSpan(mMeterSerialNumberBuf, len)); |
| } |
| } |
| |
| void SaveProtocolVersion(const DataModel::Nullable<CharSpan> & newValue) |
| { |
| if (NullableCharSpansEqual(newValue, mProtocolVersion)) |
| { |
| return; |
| } |
| |
| if (!mProtocolVersion.IsNull()) |
| { |
| mProtocolVersion.SetNull(); |
| } |
| |
| if (!newValue.IsNull()) |
| { |
| const size_t len = newValue.IsNull() ? 0 |
| : newValue.Value().size() < kMaximumStringSize ? newValue.Value().size() |
| : kMaximumStringSize; |
| memmove(mProtocolVersionBuf, newValue.Value().data(), len); |
| mProtocolVersion = DataModel::MakeNullable(CharSpan(mProtocolVersionBuf, len)); |
| } |
| } |
| |
| void SaveAttributes() |
| { |
| mInstance = GetInstance(); |
| VerifyOrDieWithMsg(mInstance, AppServer, "Meter Identification instance is null"); |
| mMeterType = mInstance->GetMeterType(); |
| SavePointOfDelivery(mInstance->GetPointOfDelivery()); |
| SaveMeterSerialNumber(mInstance->GetMeterSerialNumber()); |
| SaveProtocolVersion(mInstance->GetProtocolVersion()); |
| mPowerThreshold = mInstance->GetPowerThreshold(); |
| } |
| |
| void ClearAttributes() |
| { |
| mPointOfDelivery.SetNull(); |
| mMeterSerialNumber.SetNull(); |
| mProtocolVersion.SetNull(); |
| mMeterType.SetNull(); |
| mPowerThreshold.SetNull(); |
| mInstance = nullptr; |
| } |
| |
| void RestoreAttributes() const |
| { |
| if (mInstance) |
| { |
| mInstance->SetMeterType(mMeterType); |
| mInstance->SetPointOfDelivery(mPointOfDelivery); |
| mInstance->SetMeterSerialNumber(mMeterSerialNumber); |
| mInstance->SetProtocolVersion(mProtocolVersion); |
| mInstance->SetPowerThreshold(mPowerThreshold); |
| } |
| } |
| |
| void UpdAttrsByPresetIdx() |
| { |
| mInstance->SetMeterType(TestsDataPresets[mPresetsIdx].meterType); |
| mInstance->SetPointOfDelivery(TestsDataPresets[mPresetsIdx].pointOfDelivery); |
| mInstance->SetMeterSerialNumber(TestsDataPresets[mPresetsIdx].meterSerialNumber); |
| mInstance->SetProtocolVersion(TestsDataPresets[mPresetsIdx].protocolVersion); |
| mInstance->SetPowerThreshold(TestsDataPresets[mPresetsIdx].powerThreshold); |
| |
| mPresetsIdx = !mPresetsIdx; |
| } |
| |
| public: |
| OldMeterIdentificationAttributes() { mPresetsIdx = 0; }; |
| ~OldMeterIdentificationAttributes() = default; |
| |
| void Update() |
| { |
| if (!mInstance) |
| { |
| SaveAttributes(); |
| } |
| |
| UpdAttrsByPresetIdx(); |
| } |
| |
| void Clear() |
| { |
| RestoreAttributes(); |
| ClearAttributes(); |
| } |
| }; |
| |
| OldMeterIdentificationAttributes mOldMeterIdentificationAttributes; |
| } // namespace |
| |
| bool HandleMeterIdentificationTestEventTrigger(uint64_t eventTrigger) |
| { |
| MeterIdentificationTrigger trigger = static_cast<MeterIdentificationTrigger>(eventTrigger); |
| |
| switch (trigger) |
| { |
| case MeterIdentificationTrigger::kAttributesValueUpdate: |
| ChipLogProgress(Support, "[MTRID-Test-Event] => Attributes value update"); |
| mOldMeterIdentificationAttributes.Update(); |
| break; |
| case MeterIdentificationTrigger::kAttributesValueUpdateClear: |
| ChipLogProgress(Support, "[MTRID-Test-Event] => Attributes value clear"); |
| mOldMeterIdentificationAttributes.Clear(); |
| break; |
| default: |
| return false; |
| } |
| |
| return true; |
| } |