| <?xml version="1.0"?> |
| <!--
|
| Copyright (C) Connectivity Standards Alliance (2021). All rights reserved.
|
| The information within this document is the property of the Connectivity
|
| Standards Alliance and its use and disclosure are restricted, except as
|
| expressly set forth herein.
|
|
|
| Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive,
|
| nontransferable, worldwide, limited and revocable license (without the right to
|
| sublicense), under Connectivity Standards Alliance's applicable copyright
|
| rights, to view, download, save, reproduce and use the document solely for your
|
| own internal purposes and in accordance with the terms of the license set forth
|
| herein. This license does not authorize you to, and you expressly warrant that
|
| you shall not: (a) permit others (outside your organization) to use this
|
| document; (b) post or publish this document; (c) modify, adapt, translate, or
|
| otherwise change this document in any manner or create any derivative work
|
| based on this document; (d) remove or modify any notice or label on this
|
| document, including this Copyright Notice, License and Disclaimer. The
|
| Connectivity Standards Alliance does not grant you any license hereunder other
|
| than as expressly stated herein.
|
|
|
| Elements of this document may be subject to third party intellectual property
|
| rights, including without limitation, patent, copyright or trademark rights,
|
| and any such third party may or may not be a member of the Connectivity
|
| Standards Alliance. Connectivity Standards Alliance members grant other
|
| Connectivity Standards Alliance members certain intellectual property rights as
|
| set forth in the Connectivity Standards Alliance IPR Policy. Connectivity
|
| Standards Alliance members do not grant you any rights under this license. The
|
| Connectivity Standards Alliance is not responsible for, and shall not be held
|
| responsible in any manner for, identifying or failing to identify any or all
|
| such third party intellectual property rights. Please visit www.csa-iot.org for
|
| more information on how to become a member of the Connectivity Standards
|
| Alliance.
|
|
|
| This document and the information contained herein are provided on an “AS IS”
|
| basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS
|
| OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE
|
| INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING
|
| WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT
|
| OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS
|
| FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE
|
| CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF
|
| BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER
|
| DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL
|
| DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT
|
| OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
|
| LOSS OR DAMAGE.
|
|
|
| All company, brand and product names in this document may be trademarks that
|
| are the sole property of their respective owners.
|
|
|
| This notice and disclaimer must be included on all copies of this document.
|
|
|
| Connectivity Standards Alliance
|
| 508 Second Street, Suite 206
|
| Davis, CA 95616, USA
|
| --> |
| <cluster xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="types types.xsd cluster cluster.xsd" id="0x0200" name="Pump Configuration and Control" revision="4"> |
| <revisionHistory> |
| <revision revision="1" summary="Mandatory global ClusterRevision attribute added"/> |
| <revision revision="2" summary="All Hubs changes"/> |
| <revision revision="3" summary="New data model format and notation, added additional events"/> |
| <revision revision="4" summary="Added feature map"/> |
| </revisionHistory> |
| <clusterIds> |
| <clusterId id="0x0200" name="Pump Configuration and Control"/> |
| </clusterIds> |
| <classification hierarchy="base" role="application" picsCode="PCC" scope="Endpoint"/> |
| <features> |
| <feature bit="0" code="PRSCONST" name="ConstantPressure" summary="Supports operating in constant pressure mode"> |
| <optionalConform choice="a" more="true"/> |
| </feature> |
| <feature bit="1" code="PRSCOMP" name="CompensatedPressure" summary="Supports operating in compensated pressure mode"> |
| <optionalConform choice="a" more="true"/> |
| </feature> |
| <feature bit="2" code="FLW" name="ConstantFlow" summary="Supports operating in constant flow mode"> |
| <optionalConform choice="a" more="true"/> |
| </feature> |
| <feature bit="3" code="SPD" name="ConstantSpeed" summary="Supports operating in constant speed mode"> |
| <optionalConform choice="a" more="true"/> |
| </feature> |
| <feature bit="4" code="TEMP" name="ConstantTemperature" summary="Supports operating in constant temperature mode"> |
| <optionalConform choice="a" more="true"/> |
| </feature> |
| <feature bit="5" code="AUTO" name="Automatic" summary="Supports operating in automatic mode"> |
| <optionalConform/> |
| </feature> |
| <feature bit="6" code="LOCAL" name="LocalOperation" summary="Supports operating using local settings"> |
| <optionalConform/> |
| </feature> |
| </features> |
| <dataTypes> |
| <enum name="ControlModeEnum"> |
| <item value="0" name="ConstantSpeed" summary="The pump is running at a constant speed."> |
| <mandatoryConform> |
| <feature name="SPD"/> |
| </mandatoryConform> |
| </item> |
| <item value="1" name="ConstantPressure" summary="The pump will regulate its speed to maintain a constant differential pressure over its flanges."> |
| <mandatoryConform> |
| <feature name="PRSCONST"/> |
| </mandatoryConform> |
| </item> |
| <item value="2" name="ProportionalPressure" summary="The pump will regulate its speed to maintain a constant differential pressure over its flanges."> |
| <mandatoryConform> |
| <feature name="PRSCOMP"/> |
| </mandatoryConform> |
| </item> |
| <item value="3" name="ConstantFlow" summary="The pump will regulate its speed to maintain a constant flow through the pump."> |
| <mandatoryConform> |
| <feature name="FLW"/> |
| </mandatoryConform> |
| </item> |
| <item value="5" name="ConstantTemperature" summary="The pump will regulate its speed to maintain a constant temperature."> |
| <mandatoryConform> |
| <feature name="TEMP"/> |
| </mandatoryConform> |
| </item> |
| <item value="7" name="Automatic" summary="The operation of the pump is automatically optimized to provide the most suitable performance with respect to comfort and energy savings."> |
| <mandatoryConform> |
| <feature name="AUTO"/> |
| </mandatoryConform> |
| </item> |
| </enum> |
| <enum name="OperationModeEnum"> |
| <item value="0" name="Normal" summary="The pump is controlled by a setpoint, as defined by a connected remote sensor or by the ControlMode attribute."> |
| <mandatoryConform/> |
| </item> |
| <item value="1" name="Minimum" summary="This value sets the pump to run at the minimum possible speed it can without being stopped."> |
| <mandatoryConform> |
| <feature name="SPD"/> |
| </mandatoryConform> |
| </item> |
| <item value="2" name="Maximum" summary="This value sets the pump to run at its maximum possible speed."> |
| <mandatoryConform> |
| <feature name="SPD"/> |
| </mandatoryConform> |
| </item> |
| <item value="3" name="Local" summary="This value sets the pump to run with the local settings of the pump, regardless of what these are."> |
| <mandatoryConform> |
| <feature name="LOCAL"/> |
| </mandatoryConform> |
| </item> |
| </enum> |
| <bitmap name="PumpStatusBitmap"> |
| <bitfield name="DeviceFault" bit="0" summary="A fault related to the system or pump device is detected."> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="SupplyFault" bit="1" summary="A fault related to the supply to the pump is detected."> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="SpeedLow" bit="2" summary="Setpoint is too low to achieve."> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="SpeedHigh" bit="3" summary="Setpoint is too high to achieve."> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="LocalOverride" bit="4" summary="Device control is overridden by hardware, such as an external STOP button or via a local HMI."> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="Running" bit="5" summary="Pump is currently running"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="RemotePressure" bit="6" summary="A remote pressure sensor is used as the sensor for the regulation of the pump."> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="RemoteFlow" bit="7" summary="A remote flow sensor is used as the sensor for the regulation of the pump."> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="RemoteTemperature" bit="8" summary="A remote temperature sensor is used as the sensor for the regulation of the pump."> |
| <mandatoryConform/> |
| </bitfield> |
| </bitmap> |
| </dataTypes> |
| <attributes> |
| <attribute id="0x0000" name="MaxPressure" type="int16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0001" name="MaxSpeed" type="uint16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0002" name="MaxFlow" type="uint16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0003" name="MinConstPressure" type="int16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="PRSCONST"/> |
| </mandatoryConform> |
| <optionalConform> |
| <feature name="AUTO"/> |
| </optionalConform> |
| </otherwiseConform> |
| </attribute> |
| <attribute id="0x0004" name="MaxConstPressure" type="int16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="PRSCONST"/> |
| </mandatoryConform> |
| <optionalConform> |
| <feature name="AUTO"/> |
| </optionalConform> |
| </otherwiseConform> |
| </attribute> |
| <attribute id="0x0005" name="MinCompPressure" type="int16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="PRSCOMP"/> |
| </mandatoryConform> |
| <optionalConform> |
| <feature name="AUTO"/> |
| </optionalConform> |
| </otherwiseConform> |
| </attribute> |
| <attribute id="0x0006" name="MaxCompPressure" type="int16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="PRSCOMP"/> |
| </mandatoryConform> |
| <optionalConform> |
| <feature name="AUTO"/> |
| </optionalConform> |
| </otherwiseConform> |
| </attribute> |
| <attribute id="0x0007" name="MinConstSpeed" type="uint16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="SPD"/> |
| </mandatoryConform> |
| <optionalConform> |
| <feature name="AUTO"/> |
| </optionalConform> |
| </otherwiseConform> |
| </attribute> |
| <attribute id="0x0008" name="MaxConstSpeed" type="uint16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="SPD"/> |
| </mandatoryConform> |
| <optionalConform> |
| <feature name="AUTO"/> |
| </optionalConform> |
| </otherwiseConform> |
| </attribute> |
| <attribute id="0x0009" name="MinConstFlow" type="uint16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="FLW"/> |
| </mandatoryConform> |
| <optionalConform> |
| <feature name="AUTO"/> |
| </optionalConform> |
| </otherwiseConform> |
| </attribute> |
| <attribute id="0x000A" name="MaxConstFlow" type="uint16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="FLW"/> |
| </mandatoryConform> |
| <optionalConform> |
| <feature name="AUTO"/> |
| </optionalConform> |
| </otherwiseConform> |
| </attribute> |
| <attribute id="0x000B" name="MinConstTemp" type="int16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="TEMP"/> |
| </mandatoryConform> |
| <optionalConform> |
| <feature name="AUTO"/> |
| </optionalConform> |
| </otherwiseConform> |
| <constraint type="min" value="-27315"/> |
| </attribute> |
| <attribute id="0x000C" name="MaxConstTemp" type="int16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="fixed" reportable="false"/> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="TEMP"/> |
| </mandatoryConform> |
| <optionalConform> |
| <feature name="AUTO"/> |
| </optionalConform> |
| </otherwiseConform> |
| <constraint type="min" value="-27315"/> |
| </attribute> |
| <attribute id="0x0010" name="PumpStatus" type="PumpStatusBitmap" default="0"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="volatile" reportable="true"/> |
| <optionalConform/> |
| <constraint type="desc"/> |
| </attribute> |
| <attribute id="0x0011" name="EffectiveOperationMode" type="OperationModeEnum" default="desc"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform/> |
| <constraint type="desc"/> |
| </attribute> |
| <attribute id="0x0012" name="EffectiveControlMode" type="ControlModeEnum" default="desc"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform/> |
| <constraint type="desc"/> |
| </attribute> |
| <attribute id="0x0013" name="Capacity" type="int16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="true"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0014" name="Speed" type="uint16" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <optionalConform/> |
| </attribute> |
| <attribute id="0x0015" name="LifetimeRunningHours" type="uint24" default="0"> |
| <access read="true" write="true" readPrivilege="view" writePrivilege="manage"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false"/> |
| <optionalConform/> |
| </attribute> |
| <attribute id="0x0016" name="Power" type="uint24" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <optionalConform/> |
| </attribute> |
| <attribute id="0x0017" name="LifetimeEnergyConsumed" type="uint32" default="0"> |
| <access read="true" write="true" readPrivilege="view" writePrivilege="manage"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false"/> |
| <optionalConform/> |
| </attribute> |
| <attribute id="0x0020" name="OperationMode" type="OperationModeEnum" default="0"> |
| <access read="true" write="true" readPrivilege="view" writePrivilege="manage"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform/> |
| <constraint type="desc"/> |
| </attribute> |
| <attribute id="0x0021" name="ControlMode" type="ControlModeEnum" default="0"> |
| <access read="true" write="true" readPrivilege="view" writePrivilege="manage"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false"/> |
| <optionalConform/> |
| <constraint type="desc"/> |
| </attribute> |
| <attribute id="0x0022" name="AlarmMask" type="map16" default="0"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false"/> |
| <deprecateConform/> |
| <constraint type="desc"/> |
| </attribute> |
| </attributes> |
| <events> |
| <event id="0x00" name="SupplyVoltageLow" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x01" name="SupplyVoltageHigh" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x02" name="PowerMissingPhase" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x03" name="SystemPressureLow" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x04" name="SystemPressureHigh" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x05" name="DryRunning" priority="critical"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x06" name="MotorTemperatureHigh" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x07" name="PumpMotorFatalFailure" priority="critical"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x08" name="ElectronicTemperatureHigh" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x09" name="PumpBlocked" priority="critical"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x0A" name="SensorFailure" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x0B" name="ElectronicNonFatalFailure" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x0C" name="ElectronicFatalFailure" priority="critical"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x0D" name="GeneralFault" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x0E" name="Leakage" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x0F" name="AirDetection" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| <event id="0x10" name="TurbineOperation" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform/> |
| </event> |
| </events> |
| </cluster> |