| <?xml version="1.0"?> |
| <!--
|
| Copyright (C) Connectivity Standards Alliance (2023). All rights reserved.
|
| The information within this document is the property of the Connectivity
|
| Standards Alliance and its use and disclosure are restricted, except as
|
| expressly set forth herein.
|
|
|
| Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive,
|
| nontransferable, worldwide, limited and revocable license (without the right to
|
| sublicense), under Connectivity Standards Alliance's applicable copyright
|
| rights, to view, download, save, reproduce and use the document solely for your
|
| own internal purposes and in accordance with the terms of the license set forth
|
| herein. This license does not authorize you to, and you expressly warrant that
|
| you shall not: (a) permit others (outside your organization) to use this
|
| document; (b) post or publish this document; (c) modify, adapt, translate, or
|
| otherwise change this document in any manner or create any derivative work
|
| based on this document; (d) remove or modify any notice or label on this
|
| document, including this Copyright Notice, License and Disclaimer. The
|
| Connectivity Standards Alliance does not grant you any license hereunder other
|
| than as expressly stated herein.
|
|
|
| Elements of this document may be subject to third party intellectual property
|
| rights, including without limitation, patent, copyright or trademark rights,
|
| and any such third party may or may not be a member of the Connectivity
|
| Standards Alliance. Connectivity Standards Alliance members grant other
|
| Connectivity Standards Alliance members certain intellectual property rights as
|
| set forth in the Connectivity Standards Alliance IPR Policy. Connectivity
|
| Standards Alliance members do not grant you any rights under this license. The
|
| Connectivity Standards Alliance is not responsible for, and shall not be held
|
| responsible in any manner for, identifying or failing to identify any or all
|
| such third party intellectual property rights. Please visit www.csa-iot.org for
|
| more information on how to become a member of the Connectivity Standards
|
| Alliance.
|
|
|
| This document and the information contained herein are provided on an “AS IS”
|
| basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS
|
| OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE
|
| INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING
|
| WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT
|
| OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS
|
| FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE
|
| CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF
|
| BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER
|
| DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL
|
| DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT
|
| OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
|
| LOSS OR DAMAGE.
|
|
|
| All company, brand and product names in this document may be trademarks that
|
| are the sole property of their respective owners.
|
|
|
| This notice and disclaimer must be included on all copies of this document.
|
|
|
| Connectivity Standards Alliance
|
| 508 Second Street, Suite 206
|
| Davis, CA 95616, USA
|
| --> |
| <cluster xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="types types.xsd cluster cluster.xsd" id="0x0090" name="Electrical Power Measurement" revision="1"> |
| <revisionHistory> |
| <revision revision="1" summary="Initial Release"/> |
| </revisionHistory> |
| <classification hierarchy="base" role="application" picsCode="EMR" scope="Endpoint"/> |
| <features> |
| <feature bit="0" code="DIRC" name="DirectCurrent" summary="Measurement of direct current"> |
| <optionalConform choice="a" more="true"/> |
| </feature> |
| <feature bit="1" code="ALTC" name="AlternatingCurrent" summary="Measurement of alternating current"> |
| <optionalConform choice="a" more="true"/> |
| </feature> |
| <feature bit="2" code="THRP" name="ThreePhasePower" summary="Represents a three-phase connection"> |
| <optionalConform> |
| <feature name="ALTC"/> |
| </optionalConform> |
| </feature> |
| <feature bit="3" code="HARM" name="Harmonics" summary="Measurement of AC harmonics"> |
| <optionalConform> |
| <feature name="ALTC"/> |
| </optionalConform> |
| </feature> |
| <feature bit="4" code="PWRQ" name="PowerQuality" summary="Measurement of AC harmonic phases"> |
| <optionalConform> |
| <feature name="ALTC"/> |
| </optionalConform> |
| </feature> |
| </features> |
| <dataTypes> |
| <enum name="MeasurementTypeEnum"> |
| <item value="0" name="Unspecified"> |
| <mandatoryConform/> |
| </item> |
| <item value="1" name="Voltage"> |
| <mandatoryConform/> |
| </item> |
| <item value="2" name="Current"> |
| <mandatoryConform/> |
| </item> |
| <item value="3" name="ActivePower"> |
| <mandatoryConform/> |
| </item> |
| <item value="4" name="RMSCurrent"> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| </item> |
| <item value="5" name="RMSPower"> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| </item> |
| <item value="6" name="ApparentPower"> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| </item> |
| <item value="7" name="ReactivePower"> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| </item> |
| <item value="8" name="Frequency"> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| </item> |
| <item value="9" name="PowerFactor"> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| </item> |
| <item value="10" name="LineCurrent"> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| </item> |
| <item value="11" name="NeutralCurrent"> |
| <mandatoryConform> |
| <feature name="THRP"/> |
| </mandatoryConform> |
| </item> |
| </enum> |
| <enum name="PowerModeEnum"> |
| <item value="0" name="Unspecified"> |
| <mandatoryConform/> |
| </item> |
| <item value="1" name="DC"/> |
| <item value="2" name="AC"/> |
| </enum> |
| <struct name="HarmonicMeasurementStruct"> |
| <field id="0" name="Order" type="uint8" default="1"> |
| <access read="true"/> |
| <mandatoryConform/> |
| <constraint type="min" value="1"/> |
| </field> |
| <field id="1" name="Measurement" type="int32" default="null"> |
| <access read="true"/> |
| <quality nullable="true"/> |
| <mandatoryConform/> |
| </field> |
| </struct> |
| <struct name="MeasurementAccuracyStruct"> |
| <field id="0" name="MeasurementType" type="MeasurementTypeEnum"> |
| <access read="true"/> |
| <mandatoryConform/> |
| </field> |
| <field id="1" name="Measured" type="bool" default="false"> |
| <access read="true"/> |
| <mandatoryConform/> |
| </field> |
| <field id="2" name="PercentTypical" type="percent100ths" default="0"> |
| <access read="true"/> |
| <quality nullable="true"/> |
| <optionalConform choice="a"/> |
| </field> |
| <field id="3" name="FixedTypical" type="int64" default="0"> |
| <access read="true"/> |
| <quality nullable="true"/> |
| <optionalConform choice="a"/> |
| <constraint type="min" value="0"/> |
| </field> |
| <field id="4" name="PercentMin" type="percent100ths" default="0"> |
| <access read="true"/> |
| <optionalConform/> |
| </field> |
| <field id="4" name="FixedMin" type="int64" default="0"> |
| <access read="true"/> |
| <optionalConform/> |
| <constraint type="min" value="0"/> |
| </field> |
| <field id="5" name="PercentMax" type="percent100ths" default="0"> |
| <access read="true"/> |
| <optionalConform/> |
| </field> |
| <field id="5" name="FixedMax" type="int64" default="0"> |
| <access read="true"/> |
| <optionalConform/> |
| <constraint type="min" value="0"/> |
| </field> |
| </struct> |
| <struct name="MeasurementRangeStruct"> |
| <field id="0" name="MeasurementType" type="MeasurementTypeEnum" default="0"> |
| <access read="true"/> |
| <mandatoryConform/> |
| </field> |
| <field id="1" name="Min" type="int64" default="null"> |
| <access read="true"/> |
| <quality nullable="true"/> |
| <mandatoryConform/> |
| </field> |
| <field id="2" name="MinTimestamp" type="epoch-s" default="null"> |
| <access read="true"/> |
| <quality nullable="true"/> |
| <mandatoryConform/> |
| </field> |
| <field id="3" name="Max" type="int64" default="null"> |
| <access read="true"/> |
| <quality nullable="true"/> |
| <mandatoryConform/> |
| </field> |
| <field id="4" name="MaxTimestamp" type="epoch-s" default="null"> |
| <access read="true"/> |
| <quality nullable="true"/> |
| <mandatoryConform/> |
| </field> |
| </struct> |
| </dataTypes> |
| <attributes> |
| <attribute id="0x0000" name="PowerMode" type="PowerModeEnum"> |
| <access read="true" readPrivilege="view"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0001" name="Accuracy" type="list"> |
| <entry type="MeasurementAccuracyStruct"/> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="fixed" reportable="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0002" name="Ranges" type="list"> |
| <entry type="MeasurementRangeStruct"/> |
| <access read="true" readPrivilege="view"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0003" name="Voltage" type="int64" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0004" name="Current" type="int64" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0005" name="ActivePower" type="int64" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0006" name="RMSCurrent" type="int64" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| </attribute> |
| <attribute id="0x0007" name="RMSPower" type="int64" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| </attribute> |
| <attribute id="0x0008" name="ApparentPower" type="int64" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| </attribute> |
| <attribute id="0x0009" name="ReactivePower" type="int64" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| </attribute> |
| <attribute id="0x000A" name="Frequency" type="int64" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| <constraint type="between" from="0" to="1000000"/> |
| </attribute> |
| <attribute id="0x000B" name="HarmonicCurrents" type="list" default="null"> |
| <entry type="HarmonicMeasurementStruct"/> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="HARM"/> |
| </mandatoryConform> |
| <constraint type="desc"/> |
| </attribute> |
| <attribute id="0x000C" name="HarmonicPhases" type="list" default="null"> |
| <entry type="HarmonicMeasurementStruct"/> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="PWRQ"/> |
| </mandatoryConform> |
| <constraint type="desc"/> |
| </attribute> |
| <attribute id="0x000D" name="PowerFactor" type="int64" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <optionalConform/> |
| <constraint type="between" from="-10000" to="+10000"/> |
| </attribute> |
| <attribute id="0x000E" name="LineCurrent" type="int64" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="ALTC"/> |
| </mandatoryConform> |
| <constraint type="min" value="0"/> |
| </attribute> |
| <attribute id="0x000F" name="NeutralCurrent" type="int64" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="THRP"/> |
| </mandatoryConform> |
| </attribute> |
| </attributes> |
| <events> |
| <event id="0x00" name="MeasurementPeriodRange" priority="info"> |
| <access readPrivilege="view"/> |
| <mandatoryConform/> |
| <field id="0" name="MeasurementType" type="MeasurementTypeEnum"> |
| <mandatoryConform/> |
| </field> |
| <field id="1" name="PeriodStart" type="epoch-s"> |
| <mandatoryConform/> |
| </field> |
| <field id="2" name="PeriodEnd" type="epoch-s"> |
| <mandatoryConform/> |
| </field> |
| <field id="3" name="Min" type="int64"> |
| <mandatoryConform/> |
| </field> |
| <field id="4" name="MinTimestamp" type="epoch-s"> |
| <mandatoryConform/> |
| </field> |
| <field id="5" name="Max" type="int64"> |
| <mandatoryConform/> |
| </field> |
| <field id="6" name="MaxTimestamp" type="epoch-s"> |
| <mandatoryConform/> |
| </field> |
| </event> |
| </events> |
| </cluster> |