| <?xml version="1.0"?> |
| <!--
|
| Copyright (C) Connectivity Standards Alliance (2021). All rights reserved.
|
| The information within this document is the property of the Connectivity
|
| Standards Alliance and its use and disclosure are restricted, except as
|
| expressly set forth herein.
|
|
|
| Connectivity Standards Alliance hereby grants you a fully-paid, non-exclusive,
|
| nontransferable, worldwide, limited and revocable license (without the right to
|
| sublicense), under Connectivity Standards Alliance's applicable copyright
|
| rights, to view, download, save, reproduce and use the document solely for your
|
| own internal purposes and in accordance with the terms of the license set forth
|
| herein. This license does not authorize you to, and you expressly warrant that
|
| you shall not: (a) permit others (outside your organization) to use this
|
| document; (b) post or publish this document; (c) modify, adapt, translate, or
|
| otherwise change this document in any manner or create any derivative work
|
| based on this document; (d) remove or modify any notice or label on this
|
| document, including this Copyright Notice, License and Disclaimer. The
|
| Connectivity Standards Alliance does not grant you any license hereunder other
|
| than as expressly stated herein.
|
|
|
| Elements of this document may be subject to third party intellectual property
|
| rights, including without limitation, patent, copyright or trademark rights,
|
| and any such third party may or may not be a member of the Connectivity
|
| Standards Alliance. Connectivity Standards Alliance members grant other
|
| Connectivity Standards Alliance members certain intellectual property rights as
|
| set forth in the Connectivity Standards Alliance IPR Policy. Connectivity
|
| Standards Alliance members do not grant you any rights under this license. The
|
| Connectivity Standards Alliance is not responsible for, and shall not be held
|
| responsible in any manner for, identifying or failing to identify any or all
|
| such third party intellectual property rights. Please visit www.csa-iot.org for
|
| more information on how to become a member of the Connectivity Standards
|
| Alliance.
|
|
|
| This document and the information contained herein are provided on an “AS IS”
|
| basis and the Connectivity Standards Alliance DISCLAIMS ALL WARRANTIES EXPRESS
|
| OR IMPLIED, INCLUDING BUT NOT LIMITED TO (A) ANY WARRANTY THAT THE USE OF THE
|
| INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OF THIRD PARTIES (INCLUDING
|
| WITHOUT LIMITATION ANY INTELLECTUAL PROPERTY RIGHTS INCLUDING PATENT, COPYRIGHT
|
| OR TRADEMARK RIGHTS); OR (B) ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS
|
| FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT. IN NO EVENT WILL THE
|
| CONNECTIVITY STANDARDS ALLIANCE BE LIABLE FOR ANY LOSS OF PROFITS, LOSS OF
|
| BUSINESS, LOSS OF USE OF DATA, INTERRUPTION OF BUSINESS, OR FOR ANY OTHER
|
| DIRECT, INDIRECT, SPECIAL OR EXEMPLARY, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL
|
| DAMAGES OF ANY KIND, IN CONTRACT OR IN TORT, IN CONNECTION WITH THIS DOCUMENT
|
| OR THE INFORMATION CONTAINED HEREIN, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
|
| LOSS OR DAMAGE.
|
|
|
| All company, brand and product names in this document may be trademarks that
|
| are the sole property of their respective owners.
|
|
|
| This notice and disclaimer must be included on all copies of this document.
|
|
|
| Connectivity Standards Alliance
|
| 508 Second Street, Suite 206
|
| Davis, CA 95616, USA
|
| --> |
| <cluster xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="types types.xsd cluster cluster.xsd" id="0x0099" name="Energy EVSE" revision="2"> |
| <revisionHistory> |
| <revision revision="1" summary="Initial Release"/> |
| <revision revision="2" summary="Updates after 0.7 Ballot review"/> |
| </revisionHistory> |
| <classification hierarchy="base" role="application" picsCode="EEVSE" scope="Endpoint"/> |
| <features> |
| <feature bit="0" code="PREF" name="ChargingPreferences" summary="EVSE supports storing user charging preferences"> |
| <optionalConform/> |
| </feature> |
| <feature bit="1" code="SOC" name="SoCReporting" summary="EVSE supports reporting of vehicle State of Charge (SoC)"> |
| <provisionalConform/> |
| </feature> |
| <feature bit="2" code="PNC" name="PlugAndCharge" summary="EVSE supports PLC to support Plug and Charge"> |
| <provisionalConform/> |
| </feature> |
| <feature bit="3" code="RFID" name="RFID" summary="EVSE is fitted with an RFID reader"> |
| <optionalConform/> |
| </feature> |
| <feature bit="4" code="V2X" name="V2X" summary="EVSE supports bi-directional charging / discharging"> |
| <provisionalConform/> |
| </feature> |
| </features> |
| <dataTypes> |
| <number name="ChargingTargets Field" type=""/> |
| <number name="DayOfWeekForSequence Field" type=""/> |
| <enum name="EnergyTransferStoppedReasonEnum"> |
| <item value="0" name="EVStopped" summary="The EV decided to stop"> |
| <mandatoryConform/> |
| </item> |
| <item value="1" name="EVSEStopped" summary="The EVSE decided to stop"> |
| <mandatoryConform/> |
| </item> |
| <item value="2" name="Other" summary="An other unknown reason"> |
| <mandatoryConform/> |
| </item> |
| </enum> |
| <enum name="FaultStateEnum"> |
| <item value="0" name="NoError" summary="The EVSE is not in an error state."> |
| <mandatoryConform/> |
| </item> |
| <item value="1" name="MeterFailure" summary="The EVSE is unable to obtain electrical measurements."> |
| <mandatoryConform/> |
| </item> |
| <item value="2" name="OverVoltage" summary="The EVSE input voltage level is too high."> |
| <mandatoryConform/> |
| </item> |
| <item value="3" name="UnderVoltage" summary="The EVSE input voltage level is too low."> |
| <mandatoryConform/> |
| </item> |
| <item value="4" name="OverCurrent" summary="The EVSE detected charging current higher than allowed by charger."> |
| <mandatoryConform/> |
| </item> |
| <item value="5" name="ContactWetFailure" summary="The EVSE detected voltage on charging pins when the contactor is open."> |
| <mandatoryConform/> |
| </item> |
| <item value="6" name="ContactDryFailure" summary="The EVSE detected absence of voltage after enabling contactor."> |
| <mandatoryConform/> |
| </item> |
| <item value="7" name="GroundFault" summary="The EVSE has an unbalanced current supply."> |
| <mandatoryConform/> |
| </item> |
| <item value="8" name="PowerLoss" summary="The EVSE has detected a loss in power."> |
| <mandatoryConform/> |
| </item> |
| <item value="9" name="PowerQuality" summary="The EVSE has detected another power quality issue (e.g. phase imbalance)."> |
| <mandatoryConform/> |
| </item> |
| <item value="10" name="PilotShortCircuit" summary="The EVSE pilot signal amplitude short circuited to ground."> |
| <mandatoryConform/> |
| </item> |
| <item value="11" name="EmergencyStop" summary="The emergency stop button was pressed."> |
| <mandatoryConform/> |
| </item> |
| <item value="12" name="EVDisconnected" summary="The EVSE detected that the cable has been disconnected."> |
| <mandatoryConform/> |
| </item> |
| <item value="13" name="WrongPowerSupply" summary="The EVSE could not determine proper power supply level."> |
| <mandatoryConform/> |
| </item> |
| <item value="14" name="LiveNeutralSwap" summary="The EVSE detected Live and Neutral are swapped."> |
| <mandatoryConform/> |
| </item> |
| <item value="15" name="OverTemperature" summary="The EVSE internal temperature is too high."> |
| <mandatoryConform/> |
| </item> |
| <item value="255" name="Other" summary="Any other reason."> |
| <mandatoryConform/> |
| </item> |
| </enum> |
| <enum name="StateEnum"> |
| <item value="0" name="NotPluggedIn" summary="The EV is not plugged in."> |
| <mandatoryConform/> |
| </item> |
| <item value="1" name="PluggedInNoDemand" summary="The EV is plugged in, but not demanding current."> |
| <mandatoryConform/> |
| </item> |
| <item value="2" name="PluggedInDemand" summary="The EV is plugged in and is demanding current, but EVSE is not allowing current to flow."> |
| <mandatoryConform/> |
| </item> |
| <item value="3" name="PluggedInCharging" summary="The EV is plugged in, charging is in progress, and current is flowing"> |
| <mandatoryConform/> |
| </item> |
| <item value="4" name="PluggedInDischarging" summary="The EV is plugged in, discharging is in progress, and current is flowing"> |
| <mandatoryConform> |
| <feature name="V2X"/> |
| </mandatoryConform> |
| </item> |
| <item value="5" name="SessionEnding" summary="The EVSE is transitioning from any plugged-in state to NotPluggedIn"> |
| <mandatoryConform/> |
| </item> |
| <item value="6" name="Fault" summary="There is a fault (see FaultState Attribute attribute)"> |
| <mandatoryConform/> |
| </item> |
| </enum> |
| <enum name="SupplyStateEnum"> |
| <item value="0" name="Disabled" summary="The EV is not currently allowed to charge or discharge"> |
| <mandatoryConform/> |
| </item> |
| <item value="1" name="ChargingEnabled" summary="The EV is currently allowed to charge"> |
| <mandatoryConform/> |
| </item> |
| <item value="2" name="DischargingEnabled" summary="The EV is currently allowed to discharge"> |
| <optionalConform> |
| <feature name="V2X"/> |
| </optionalConform> |
| </item> |
| <item value="3" name="DisabledError" summary="The EV is not currently allowed to charge or discharge due to an error. |
| The error must be cleared before operation can continue."> |
| <mandatoryConform/> |
| </item> |
| <item value="4" name="DisabledDiagnostics" summary="The EV is not currently allowed to charge or discharge due |
| to Diagnostics Mode."> |
| <mandatoryConform/> |
| </item> |
| </enum> |
| <bitmap name="TargetDayOfWeekBitmap"> |
| <bitfield name="Sunday" bit="0" summary="Sunday"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="Monday" bit="1" summary="Monday"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="Tuesday" bit="2" summary="Tuesday"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="Wednesday" bit="3" summary="Wednesday"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="Thursday" bit="4" summary="Thursday"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="Friday" bit="5" summary="Friday"> |
| <mandatoryConform/> |
| </bitfield> |
| <bitfield name="Saturday" bit="6" summary="Saturday"> |
| <mandatoryConform/> |
| </bitfield> |
| </bitmap> |
| <struct name="ChargingTargetScheduleStruct"> |
| <field id="0" name="DayOfWeekForSequence" type="TargetDayOfWeekBitmap"> |
| <mandatoryConform/> |
| <constraint type="desc"/> |
| </field> |
| <field id="1" name="ChargingTargets" type="list"> |
| <entry type="ChargingTargetStruct"/> |
| <mandatoryConform/> |
| <constraint type="maxCount" value="10"/> |
| </field> |
| </struct> |
| <struct name="ChargingTargetStruct"> |
| <field id="0" name="TargetTimeMinutesPastMidnight" type="uint16" default="0"> |
| <access read="true" write="true"/> |
| <mandatoryConform/> |
| <constraint type="between" from="0" to="1439"/> |
| </field> |
| <field id="1" name="TargetSoC" type="percent" default="0"> |
| <access read="true" write="true"/> |
| <otherwiseConform> |
| <mandatoryConform> |
| <feature name="SOC"/> |
| </mandatoryConform> |
| <optionalConform choice="a" more="true"/> |
| </otherwiseConform> |
| </field> |
| <field id="2" name="AddedEnergy" type="energy-mWh" default="0"> |
| <access read="true" write="true"/> |
| <optionalConform choice="a" more="true"/> |
| <constraint type="min" value="0"/> |
| </field> |
| </struct> |
| </dataTypes> |
| <attributes> |
| <attribute id="0x0000" name="State" type="StateEnum"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0001" name="SupplyState" type="SupplyStateEnum"> |
| <access read="true" readPrivilege="view"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0002" name="FaultState" type="FaultStateEnum"> |
| <access read="true" readPrivilege="view"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0003" name="ChargingEnabledUntil" type="epoch-s" default="0"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0004" name="DischargingEnabledUntil" type="epoch-s" default="0"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="V2X"/> |
| </mandatoryConform> |
| </attribute> |
| <attribute id="0x0005" name="CircuitCapacity" type="amperage-mA" default="0"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform/> |
| <constraint type="between" from="0" to="80000"/> |
| </attribute> |
| <attribute id="0x0006" name="MinimumChargeCurrent" type="amperage-mA" default="6000"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform/> |
| <constraint type="between" from="0" to="80000"/> |
| </attribute> |
| <attribute id="0x0007" name="MaximumChargeCurrent" type="amperage-mA" default="0"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform/> |
| <constraint type="between" from="0" to="80000"/> |
| </attribute> |
| <attribute id="0x0008" name="MaximumDischargeCurrent" type="amperage-mA" default="0"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="V2X"/> |
| </mandatoryConform> |
| <constraint type="between" from="0" to="80000"/> |
| </attribute> |
| <attribute id="0x0009" name="UserMaximumChargeCurrent" type="amperage-mA" default="0"> |
| <access read="true" write="true" readPrivilege="view" writePrivilege="manage"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false"/> |
| <optionalConform/> |
| <constraint type="desc"/> |
| </attribute> |
| <attribute id="0x000A" name="RandomizationDelayWindow" type="elapsed-s" default="600"> |
| <access read="true" write="true" readPrivilege="view" writePrivilege="manage"/> |
| <quality changeOmitted="false" nullable="false" scene="false" persistence="nonVolatile" reportable="false"/> |
| <optionalConform/> |
| <constraint type="between" from="0" to="86400"/> |
| </attribute> |
| <attribute id="0x0023" name="NextChargeStartTime" type="epoch-s" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="PREF"/> |
| </mandatoryConform> |
| </attribute> |
| <attribute id="0x0024" name="NextChargeTargetTime" type="epoch-s" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="PREF"/> |
| </mandatoryConform> |
| </attribute> |
| <attribute id="0x0025" name="NextChargeRequiredEnergy" type="energy-mWh" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="PREF"/> |
| </mandatoryConform> |
| <constraint type="min" value="0"/> |
| </attribute> |
| <attribute id="0x0026" name="NextChargeTargetSoC" type="percent" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="PREF"/> |
| </mandatoryConform> |
| </attribute> |
| <attribute id="0x0027" name="ApproximateEVEfficiency" type="uint16" default="null"> |
| <access read="true" write="true" readPrivilege="view" writePrivilege="manage"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false"/> |
| <optionalConform> |
| <feature name="PREF"/> |
| </optionalConform> |
| <constraint type="desc"/> |
| </attribute> |
| <attribute id="0x0030" name="StateOfCharge" type="percent" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="SOC"/> |
| </mandatoryConform> |
| </attribute> |
| <attribute id="0x0031" name="BatteryCapacity" type="energy-mWh" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="SOC"/> |
| </mandatoryConform> |
| <constraint type="min" value="0"/> |
| </attribute> |
| <attribute id="0x0032" name="VehicleID" type="string" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="volatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="PNC"/> |
| </mandatoryConform> |
| <constraint type="maxLength" value="32"/> |
| </attribute> |
| <attribute id="0x0040" name="SessionID" type="uint32" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0041" name="SessionDuration" type="elapsed-s" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform/> |
| </attribute> |
| <attribute id="0x0042" name="SessionEnergyCharged" type="energy-mWh" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform/> |
| <constraint type="min" value="0"/> |
| </attribute> |
| <attribute id="0x0043" name="SessionEnergyDischarged" type="energy-mWh" default="null"> |
| <access read="true" readPrivilege="view"/> |
| <quality changeOmitted="false" nullable="true" scene="false" persistence="nonVolatile" reportable="false"/> |
| <mandatoryConform> |
| <feature name="V2X"/> |
| </mandatoryConform> |
| <constraint type="min" value="0"/> |
| </attribute> |
| </attributes> |
| <commands> |
| <command id="0x00" name="GetTargetsResponse" direction="responseFromServer"> |
| <access invokePrivilege="operate"/> |
| <mandatoryConform> |
| <feature name="PREF"/> |
| </mandatoryConform> |
| <field id="0" name="ChargingTargetSchedules" type="list"> |
| <entry type="ChargingTargetScheduleStruct"/> |
| <mandatoryConform/> |
| <constraint type="maxCount" value="7"/> |
| </field> |
| </command> |
| <command id="0x01" name="Disable" response="Y"> |
| <access invokePrivilege="operate" timed="true"/> |
| <mandatoryConform/> |
| </command> |
| <command id="0x02" name="EnableCharging" response="Y"> |
| <access invokePrivilege="operate" timed="true"/> |
| <mandatoryConform/> |
| <field id="0" name="ChargingEnabledUntil" type="epoch-s" default="null"> |
| <quality nullable="true"/> |
| <mandatoryConform/> |
| </field> |
| <field id="1" name="MinimumChargeCurrent" type="amperage-mA"> |
| <mandatoryConform/> |
| <constraint type="between" from="0" to="80000"/> |
| </field> |
| <field id="2" name="MaximumChargeCurrent" type="amperage-mA"> |
| <mandatoryConform/> |
| <constraint type="between" from="0" to="80000"/> |
| </field> |
| </command> |
| <command id="0x03" name="EnableDischarging" response="Y"> |
| <access invokePrivilege="operate" timed="true"/> |
| <mandatoryConform> |
| <feature name="V2X"/> |
| </mandatoryConform> |
| <field id="0" name="DischargingEnabledUntil" type="epoch-s" default="null"> |
| <quality nullable="true"/> |
| <mandatoryConform/> |
| </field> |
| <field id="1" name="MaximumDischargeCurrent" type="amperage-mA"> |
| <mandatoryConform/> |
| <constraint type="between" from="0" to="80000"/> |
| </field> |
| </command> |
| <command id="0x04" name="StartDiagnostics" response="Y"> |
| <access invokePrivilege="operate" timed="true"/> |
| <optionalConform/> |
| </command> |
| <command id="0x05" name="SetTargets" response="Y"> |
| <access invokePrivilege="operate" timed="true"/> |
| <mandatoryConform> |
| <feature name="PREF"/> |
| </mandatoryConform> |
| <field id="0" name="ChargingTargetSchedules" type="list"> |
| <entry type="ChargingTargetScheduleStruct"/> |
| <mandatoryConform/> |
| <constraint type="maxCount" value="7"/> |
| </field> |
| </command> |
| <command id="0x06" name="GetTargets" response="GetTargetsResponse"> |
| <access invokePrivilege="operate" timed="true"/> |
| <mandatoryConform> |
| <feature name="PREF"/> |
| </mandatoryConform> |
| </command> |
| <command id="0x07" name="ClearTargets" response="Y"> |
| <access invokePrivilege="operate" timed="true"/> |
| <mandatoryConform> |
| <feature name="PREF"/> |
| </mandatoryConform> |
| </command> |
| </commands> |
| <events> |
| <event id="0x00" name="EVConnected" priority="info"> |
| <access readPrivilege="view"/> |
| <mandatoryConform/> |
| <field id="0" name="SessionID" type="uint32"> |
| <mandatoryConform/> |
| </field> |
| </event> |
| <event id="0x01" name="EVNotDetected" priority="info"> |
| <access readPrivilege="view"/> |
| <mandatoryConform/> |
| <field id="0" name="SessionID" type="uint32"> |
| <mandatoryConform/> |
| </field> |
| <field id="1" name="State" type="StateEnum"> |
| <mandatoryConform/> |
| </field> |
| <field id="2" name="SessionDuration" type="elapsed-s"> |
| <mandatoryConform/> |
| </field> |
| <field id="3" name="SessionEnergyCharged" type="energy-mWh"> |
| <mandatoryConform/> |
| <constraint type="min" value="0"/> |
| </field> |
| <field id="4" name="SessionEnergyDischarged" type="energy-mWh"> |
| <mandatoryConform> |
| <feature name="V2X"/> |
| </mandatoryConform> |
| <constraint type="min" value="0"/> |
| </field> |
| </event> |
| <event id="0x02" name="EnergyTransferStarted" priority="info"> |
| <access readPrivilege="view"/> |
| <mandatoryConform/> |
| <field id="0" name="SessionID" type="uint32"> |
| <mandatoryConform/> |
| </field> |
| <field id="1" name="State" type="StateEnum"> |
| <mandatoryConform/> |
| </field> |
| <field id="2" name="MaximumCurrent" type="amperage-mA"> |
| <mandatoryConform/> |
| <constraint type="between" from="0" to="80000"/> |
| </field> |
| </event> |
| <event id="0x03" name="EnergyTransferStopped" priority="info"> |
| <access readPrivilege="view"/> |
| <mandatoryConform/> |
| <field id="0" name="SessionID" type="uint32"> |
| <mandatoryConform/> |
| </field> |
| <field id="1" name="State" type="StateEnum"> |
| <mandatoryConform/> |
| </field> |
| <field id="2" name="Reason" type="EnergyTransferStoppedReasonEnum"> |
| <mandatoryConform/> |
| </field> |
| <field id="4" name="EnergyTransferred" type="energy-mWh"> |
| <mandatoryConform/> |
| <constraint type="min" value="0"/> |
| </field> |
| </event> |
| <event id="0x04" name="Fault" priority="critical"> |
| <access readPrivilege="view"/> |
| <mandatoryConform/> |
| <field id="0" name="SessionID" type="uint32"> |
| <quality nullable="true"/> |
| <mandatoryConform/> |
| </field> |
| <field id="1" name="State" type="StateEnum"> |
| <mandatoryConform/> |
| </field> |
| <field id="2" name="FaultStatePreviousState" type="FaultStateEnum"> |
| <mandatoryConform/> |
| </field> |
| <field id="4" name="FaultStateCurrentState" type="FaultStateEnum"> |
| <mandatoryConform/> |
| </field> |
| </event> |
| <event id="0x05" name="RFID" priority="info"> |
| <access readPrivilege="view"/> |
| <optionalConform> |
| <feature name="RFID"/> |
| </optionalConform> |
| <field id="0" name="UID" type="octstr"> |
| <mandatoryConform/> |
| <constraint type="maxLength" value="10"/> |
| </field> |
| </event> |
| </events> |
| </cluster> |