blob: 887d6451867dd48b7db68a83a62d084ad0000e5b [file] [log] [blame]
# Copyright (c) 2021 Project CHIP Authors
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
name: 16.2.2. [TC-PCC-2.2] Operation Mode with Server as DUT
PICS:
- PCC.S
config:
nodeId: 0x12344321
cluster: "Pump Configuration and Control"
endpoint: 1
tests:
- label:
"Step 1: Commission DUT to TH (can be skipped if done in a preceding
test)."
cluster: "DelayCommands"
command: "WaitForCommissionee"
arguments:
values:
- name: "nodeId"
value: nodeId
- label:
"Step 2a: TH write 0 (Normal) to the OperationMode attribute to DUT"
command: "writeAttribute"
attribute: "OperationMode"
PICS: PCC.S.A0020
arguments:
value: 0
- label:
"Step 2b: TH reads from the DUT the EffectiveOperationMode attribute"
command: "readAttribute"
attribute: "EffectiveOperationMode"
PICS: PCC.S.A0011
response:
value: 0
- label:
"Step 3a: TH write 1 (Minimum) to the OperationMode attribute to DUT"
command: "writeAttribute"
attribute: "OperationMode"
PICS: PCC.S.F03 && PCC.S.A0020
arguments:
value: 1
- label:
"Step 3b: TH reads from the DUT the EffectiveOperationMode attribute"
command: "readAttribute"
attribute: "EffectiveOperationMode"
PICS: PCC.S.F03 && PCC.S.A0011
response:
value: 1
- label:
"Step 4a: TH write 2 (Maximum) to the OperationMode attribute to DUT
one at a time."
command: "writeAttribute"
attribute: "OperationMode"
PICS: PCC.S.F03 && PCC.S.A0020
arguments:
value: 2
- label:
"Step 4b: TH reads from the DUT the EffectiveOperationMode attribute"
command: "readAttribute"
attribute: "EffectiveOperationMode"
PICS: PCC.S.F03 && PCC.S.A0011
response:
value: 2
- label: "Step 5a: TH write 3 (Local) to the OperationMode attribute to DUT"
command: "writeAttribute"
attribute: "OperationMode"
PICS: PCC.S.F06 && PCC.S.A0020
arguments:
value: 3
- label:
"Step 5b: TH reads from the DUT the EffectiveOperationMode attribute"
command: "readAttribute"
attribute: "EffectiveOperationMode"
PICS: PCC.S.F06 && PCC.S.A0011
response:
value: 3