name:
3.4.2. [TC-SU-2.5] Handling different ApplyUpdateResponse scenarios on
Requestor
PICS:
- MCORE.OTA.Requestor
config:
nodeId: 0x12344321
cluster: "Basic Information"
endpoint: 0
tests:
- label:
"Step 1: OTA-P/TH sends the ApplyUpdateResponse Command to the DUT.
Action field is set to 'Proceed', DelayedActionTime is set to 0."
verification: |
./chip-ota-provider-app --discriminator 3840 --secured-device-port 5540 --KVS ~/provider/chip_kvs_provider --filepath ota-requestor-app.ota -a proceed -p 0
./chip-tool otasoftwareupdaterequestor announce-otaprovider 123 0 0 0 321 0
Where 321 is OTA Requestor node ID and 123 is OTA Provider node ID
Verify that the DUT starts updating its software.
Once the update is finished verify the software version on the DUT matches the version downloaded for the software update.
./chip-tool basicinformation read software-version 321 0
Verify the Software-Version value is 2 On TH(chip-tool) log:
[1653566686.505112][31729:31734] CHIP:TOO: Endpoint: 0 Cluster: 0x0000_0028 Attribute 0x0000_000A DataVersion: 259813380
[1653566686.505186][31729:31734] CHIP:TOO: SoftwareVersion: 2
Verify on the OTA-P/TH that there is no other ApplyUpdateRequest from the DUT.
disabled: true
- label:
"Step 2: OTA-P/TH sends the ApplyUpdateResponse Command to the DUT.
Action field is set to 'Proceed', DelayedActionTime is set to 3
minutes."
verification: |
Run the OTA Provider App using the command:
./chip-ota-provider-app --discriminator 22 --secured-device-port 5565 --KVS /tmp/chip_kvs_provider --filepath /tmp/test.bin -p 180
./chip-tool otasoftwareupdaterequestor announce-otaprovider 123 0 0 0 321 0
Where 321 is OTA Requestor node ID and 123 is OTA Provider node ID
Verify that the DUT starts updating its software after 3 minutes.Once the update is finished, verify the SoftwareVersion attribute from the Basic Information cluster on the DUT to match the version downloaded for the software update
[1653635778.270994][7933:7933] CHIP:SWU: ApplyUpdateResponse:
[1653635778.271015][7933:7933] CHIP:SWU: action: 0
[1653635778.271031][7933:7933] CHIP:SWU: delayedActionTime: 180 seconds
./chip-tool basicinformation read software-version 321 0
Verify the Software-Version value is 2 On TH(chip-tool) log:
[1653636406.637617][11116:11121] CHIP:TOO: Endpoint: 0 Cluster: 0x0000_0028 Attribute 0x0000_000A DataVersion: 1527020963
[1653636406.637708][11116:11121] CHIP:TOO: SoftwareVersion: 2
disabled: true
- label:
"Step 3: OTA-P/TH sends the ApplyUpdateResponse Command to the DUT.
Action field is set to 'AwaitNextAction', DelayedActionTime is set to
1 minute."
verification: |
Run the OTA Provider App using the command:
./chip-ota-provider-app --discriminator 22 --secured-device-port 5565 --KVS /tmp/chip_kvs_provider --filepath /tmp/test.bin -a awaitNextAction -p 60
./chip-tool otasoftwareupdaterequestor announce-otaprovider 123 0 0 0 321 0
Where 321 is OTA Requestor node ID and 123 is OTA Provider node ID
Verify that the DUT waits for the minimum interval defined by spec which is 2 minutes before re-sending the ApplyUpdateRequest to the OTA-P.
Verify that the DUT does not apply the software update within this time.
[1653640038.385848][8303:8303] CHIP:SWU: ApplyUpdateResponse:
[1653640038.385873][8303:8303] CHIP:SWU: action: 1
[1653640038.385895][8303:8303] CHIP:SWU: delayedActionTime: 60 seconds
disabled: true
- label:
"Step 4: OTA-P/TH sends the ApplyUpdateResponse Command to the DUT.
Action field is set to 'AwaitNextAction', DelayedActionTime is set to
3 minutes. On the subsequent ApplyUpdateRequest command, TH/OTA-P
sends the ApplyUpdateResponse back to DUT. Action field is set to
'Proceed'."
verification: |
Run the OTA Provider App using the command:
./chip-ota-provider-app --discriminator 22 --secured-device-port 5565 --KVS /tmp/chip_kvs_provider --filepath /tmp/test.bin -a awaitNextAction -p 180
./chip-tool otasoftwareupdaterequestor announce-otaprovider 123 0 0 0 321 0
Where 321 is OTA Requestor node ID and 123 is OTA Provider node ID
On OTA Requestor
Verify that the DUT waits for 3 minutes before sending the ApplyUpdateRequest to the OTA-P.
Verify that the DUT starts updating its software after the second ApplyUpdateResponse with Proceed action.
Once the update is finished, verify the software version from the Basic Information cluster on the DUT to match the version downloaded for the software update.
[1653651459.546867][9228:9228] CHIP:SWU: ApplyUpdateResponse:
[1653651459.546897][9228:9228] CHIP:SWU: action: 1
[1653651459.546923][9228:9228] CHIP:SWU: delayedActionTime: 180 seconds
./chip-tool basicinformation read software-version 321 0
Verify that SoftwareVersion value is 2 On TH(chip-tool) log:
[1653636406.637617][11116:11121] CHIP:TOO: Endpoint: 0 Cluster: 0x0000_0028 Attribute 0x0000_000A DataVersion: 1527020963
[1653636406.637708][11116:11121] CHIP:TOO: SoftwareVersion: 2
disabled: true
- label:
"Step 5: OTA-P/TH sends the ApplyUpdateResponse Command to the DUT.
Action field is set to 'Discontinue'."
verification: |
Run the OTA Provider App using the command:
./chip-ota-provider-app --discriminator 22 --secured-device-port 5565 --KVS /tmp/chip_kvs_provider --filepath /tmp/test.bin -a discontinue
./chip-tool otasoftwareupdaterequestor announce-otaprovider 123 0 0 0 321 0
Where 321 is OTA Requestor node ID and 123 is OTA Provider node ID
Verify that the DUT does not send the NotifyUpdateApplied within a reasonable time.
Verify that the DUT clears its previously downloaded software image and resets the UpdateState Attribute to Idle (Value 1)
./chip-tool otasoftwareupdaterequestor read update-state 321 0
Verify the UpdateSate value is 1 On TH(chip-tool) log:
[1655392988.539869][3147:3153] CHIP:TOO: Endpoint: 0 Cluster: 0x0000_002A Attribute 0x0000_0002 DataVersion: 1861243848
[1655392988.541680][3147:3153] CHIP:TOO: UpdateState: 1
Verify the software version from the Basic Information cluster of the DUT to be the same as it was previously.
./chip-tool basicinformation read software-version 321 0
Verify the SoftwareVersion value is 1 On TH(chip-tool) log:
[1653636406.637617][11116:11121] CHIP:TOO: Endpoint: 0 Cluster: 0x0000_0028 Attribute 0x0000_000A DataVersion: 1527020963
[1653636406.637708][11116:11121] CHIP:TOO: SoftwareVersion: 1
disabled: true