<configurator>
<domain name="Energy Management"/>
<bitmap name="DeviceClassBitmap" type="bitmap32">
<cluster code="0x0096"/>
<field name="HVAC" mask="0x01"/>
<field name="StripHeater" mask="0x02"/>
<field name="WaterHeater" mask="0x04"/>
<field name="PoolPump" mask="0x08"/>
<field name="SmartAppliance" mask="0x10"/>
<field name="IrrigationPump" mask="0x20"/>
<field name="CommercialLoad" mask="0x40"/>
<field name="ResidentialLoad" mask="0x80"/>
<field name="ExteriorLighting" mask="0x0100"/>
<field name="InteriorLighting" mask="0x0200"/>
<field name="EV" mask="0x0400"/>
<field name="GenerationSystem" mask="0x0800"/>
<field name="SmartInverter" mask="0x1000"/>
<field name="EVSE" mask="0x2000"/>
<field name="RESU" mask="0x4000"/>
<field name="EMS" mask="0x8000"/>
<field name="SEM" mask="0x10000"/>
</bitmap>
<bitmap name="EventControlBitmap" type="bitmap16">
<cluster code="0x0096"/>
<field name="RandomStart" mask="0x01"/>
</bitmap>
<bitmap name="EventTransitionControlBitmap" type="bitmap16">
<cluster code="0x0096"/>
<field name="RandomDuration" mask="0x01"/>
<field name="IgnoreOptOut" mask="0x02"/>
</bitmap>
<bitmap name="CancelControlBitmap" type="bitmap16">
<cluster code="0x0096"/>
<field name="RandomEnd" mask="0x01"/>
</bitmap>
<enum name="LoadControlEventChangeSourceEnum" type="enum8">
<cluster code="0x0096"/>
<item name="Automatic" value="0x00"/>
<item name="UserAction" value="0x01"/>
</enum>
<enum name="LoadControlEventStatusEnum" type="enum8">
<cluster code="0x0096"/>
<item name="Unknown" value="0x00"/>
<item name="Received" value="0x01"/>
<item name="InProgress" value="0x02"/>
<item name="Completed" value="0x03"/>
<item name="OptedOut" value="0x04"/>
<item name="OptedIn" value="0x05"/>
<item name="Canceled" value="0x06"/>
<item name="Superseded" value="0x07"/>
<item name="PartialOptedOut" value="0x08"/>
<item name="PartialOptedIn" value="0x09"/>
<item name="NoParticipation" value="0x0A"/>
<item name="Unavailable" value="0x0B"/>
<item name="Failed" value="0x0C"/>
</enum>
<enum name="CriticalityLevelEnum" type="enum8">
<cluster code="0x0096"/>
<item name="Unknown" value="0x00"/>
<item name="Green" value="0x01"/>
<item name="Level1" value="0x02"/>
<item name="Level2" value="0x03"/>
<item name="Level3" value="0x04"/>
<item name="Level4" value="0x05"/>
<item name="Level5" value="0x06"/>
<item name="Emergency" value="0x07"/>
<item name="PlannedOutage" value="0x08"/>
<item name="ServiceDisconnect" value="0x09"/>
</enum>
<enum name="HeatingSourceEnum" type="enum8">
<cluster code="0x0096"/>
<item name="Any" value="0x0"/>
<item name="Electric" value="0x1"/>
<item name="NonElectric" value="0x2"/>
</enum>
<struct name="TemperatureControlStruct">
<cluster code="0x0096"/>
<!-- Note: No TemperatureDifference type available yet in ZAP XML -->
<item fieldId="0" name="CoolingTempOffset" type="int16u" isNullable="true" optional="true" />
<item fieldId="1" name="HeatingtTempOffset" type="int16u" isNullable="true" optional="true" />
<item fieldId="2" name="CoolingTempSetpoint" type="temperature" isNullable="true" optional="true" />
<item fieldId="3" name="HeatingTempSetpoint" type="temperature" isNullable="true" optional="true" />
</struct>
<struct name="AverageLoadControlStruct">
<cluster code="0x0096"/>
<item fieldId="0" name="LoadAdjustment" type="int8s" min="-100" max="100" />
</struct>
<struct name="DutyCycleControlStruct">
<cluster code="0x0096"/>
<item fieldId="0" name="DutyCycle" type="percent" />
</struct>
<struct name="PowerSavingsControlStruct">
<cluster code="0x0096"/>
<item fieldId="0" name="PowerSavings" type="percent" />
</struct>
<struct name="HeatingSourceControlStruct">
<cluster code="0x0096"/>
<item fieldId="0" name="HeatingSource" type="HeatingSourceEnum"/>
</struct>
<struct name="LoadControlEventTransitionStruct">
<cluster code="0x0096"/>
<item fieldId="0" name="Duration" type="int16u" max="1440"/>
<item fieldId="1" name="Control" type="EventTransitionControlBitmap"/>
<item fieldId="2" name="TemperatureControl" type="TemperatureControlStruct" optional="true"/>
<item fieldId="3" name="AverageLoadControl" type="AverageLoadControlStruct" optional="true"/>
<item fieldId="4" name="DutyCycleControl" type="DutyCycleControlStruct" optional="true"/>
<item fieldId="5" name="PowerSavingsControl" type="PowerSavingsControlStruct" optional="true"/>
<item fieldId="6" name="HeatingSourceControl" type="HeatingSourceControlStruct" optional="true"/>
</struct>
<!-- This does not quite match the spec, which has LoadControlEventStruct as a
fabric-scoped struct with some fabric-sensitive fields, but that doesn't
really make sense in all the places where the struct is used, and the spec
does not really define other things in a way that would work with that at
the moment. -->
<struct name="LoadControlEventStruct">
<cluster code="0x0096"/>
<item fieldId="0" name="EventID" type="octet_string" length="16"/>
<item fieldId="1" name="ProgramID" type="octet_string" length="16" isNullable="true"/>
<item fieldId="2" name="Control" type="EventControlBitmap" />
<item fieldId="3" name="DeviceClass" type="DeviceClassBitmap" />
<item fieldId="4" name="EnrollmentGroup" type="int8u" optional="true" />
<item fieldId="5" name="Criticality" type="CriticalityLevelEnum" defaut="0" />
<item fieldId="6" name="StartTime" type="epoch_s" isNullable="true" />
<item fieldId="7" name="Transitions" array="true" type="LoadControlEventTransitionStruct" />
</struct>
<struct name="LoadControlProgramStruct">
<cluster code="0x0096"/>
<item fieldId="0" name="ProgramID" type="octet_string" length="16"/>
<item fieldId="1" name="Name" type="long_char_string" length="32"/>
<item fieldId="2" name="EnrollmentGroup" type="int8u" isNullable="true" min="1" max="0xFF"/>
<item fieldId="3" name="RandomStartMinutes" type="int8u" isNullable="true" min="0x00" max="0x3C"/>
<item fieldId="4" name="RandomDurationMinutes" type="int8u" isNullable="true" min="0x00" max="0x3C"/>
</struct>
<cluster apiMaturity="provisional">
<name>Demand Response Load Control</name>
<domain>Energy Management</domain>
<description>This cluster provides an interface to the functionality of Smart Energy Demand Response and Load Control.</description>
<code>0x0096</code>
<define>DEMAND_RESPONSE_LOAD_CONTROL_CLUSTER</define>
<client tick="false" init="false">true</client>
<server tick="false" init="false">true</server>
<globalAttribute side="either" code="0xFFFD" value="4"/>
<features>
<feature bit="0" code="ENRLG" name="Enrollment Groups" summary="Supports enrollment groups">
<optionalConform/>
</feature>
<feature bit="1" code="TEMPO" name="TemperatureOffset" summary="Supports temperature offsets">
<optionalConform choice="a" more="true"/>
</feature>
<feature bit="2" code="TEMPS" name="TemperatureSetpoint" summary="Supports temperature setpoints">
<optionalConform choice="a" more="true"/>
</feature>
<feature bit="3" code="LOADA" name="LoadAdjustment" summary="Supports average load adjustment percentage">
<optionalConform choice="a" more="true"/>
</feature>
<feature bit="4" code="DUTYC" name="DutyCycle" summary="Supports duty cycle adjustment">
<optionalConform choice="a" more="true"/>
</feature>
<feature bit="5" code="PWRSV" name="PowerSavings" summary="Supports power savings">
<optionalConform choice="a" more="true"/>
</feature>
<feature bit="6" code="HEATS" name="HeatingSource" summary="Supports selecting heating source">
<optionalConform choice="a" more="true"/>
</feature>
</features>
<attribute side="server" code="0x0000" define="LOAD_CONTROL_PROGRAMS" type="array" entryType="LoadControlProgramStruct" writable="false">LoadControlPrograms</attribute>
<attribute side="server" code="0x0001" define="NUMBER_OF_LOAD_CONTROL_PROGRAMS" type="int8u" min="5" writable="false" default="5">NumberOfLoadControlPrograms</attribute>
<attribute side="server" code="0x0002" define="LOAD_CONTROL_EVENTS" type="array" entryType="LoadControlEventStruct" writable="false">Events</attribute>
<attribute side="server" code="0x0003" define="LOAD_CONTROL_ACTIVE_EVENTS" type="array" entryType="LoadControlEventStruct" writable="false">ActiveEvents</attribute>
<attribute side="server" code="0x0004" define="NUMBER_OF_EVENTS_PER_PROGRAM" type="int8u" min="10" writable="false" default="10">NumberOfEventsPerProgram</attribute>
<attribute side="server" code="0x0005" define="NUMBER_OF_TRANSITIONS" type="int8u" min="3" writable="false" default="3">NumberOfTransitions</attribute>
<attribute side="server" code="0x0006" define="DEFAULT_RANDOM_START" type="int8u" min="0" max="0x3C" default="0x1E" writable="true">
<description>DefaultRandomStart</description>
<access op="read" privilege="view"/>
<access op="write" privilege="manage"/>
</attribute>
<attribute side="server" code="0x0007" define="DEFAULT_RANDOM_DURATION" type="int8u" min="0" max="0x3C" default="0" writable="true">
<description>DefaultRandomDuration</description>
<access op="read" privilege="view"/>
<access op="write" privilege="manage"/>
</attribute>
<command source="client" code="0x00" name="RegisterLoadControlProgramRequest" optional="false">
<description>
Upon receipt, this SHALL insert a new LoadControlProgramStruct into LoadControlPrograms, or if the ProgramID matches an existing LoadControlProgramStruct, then the provider SHALL be updated with the provided values.
</description>
<arg name="LoadControlProgram" type="LoadControlProgramStruct"/>
</command>
<command source="client" code="0x01" name="UnregisterLoadControlProgramRequest" optional="false">
<description>
Upon receipt, this SHALL remove a the LoadControlProgramStruct from LoadControlPrograms with the matching ProgramID.
</description>
<arg name="LoadControlProgramID" type="octet_string" length="16"/>
</command>
<command source="client" code="0x02" name="AddLoadControlEventRequest" optional="false">
<description>
On receipt of the AddLoadControlEventsRequest command, the server SHALL add a load control event.
</description>
<arg name="Event" type="LoadControlEventStruct"/>
</command>
<command source="client" code="0x03" name="RemoveLoadControlEventRequest" optional="false">
<description>
Upon receipt, this SHALL remove the LoadControlEventStruct with the matching EventID from LoadEventPrograms.
</description>
<arg name="EventID" type="octet_string" length="16"/>
<arg name="CancelControl" type="CancelControlBitmap"/>
</command>
<command source="client" code="0x04" name="ClearLoadControlEventsRequest" optional="true">
<!-- Note: Maybe this command needs to have fields? Who knows!
Spec does not define anything about it other than its existence.
See https://github.com/CHIP-Specifications/connectedhomeip-spec/issues/8514 -->
<description>
Upon receipt, this SHALL clear all the load control events.
</description>
</command>
<event side="server" code="0x00" name="LoadControlEventStatusChange" priority="info" optional="false">
<description>This event SHALL be generated when the status of a LoadControlEventStruct changes.</description>
<field id="0" name="EventID" type="octet_string" length="16"/>
<field id="1" name="TransitionIndex" type="int8u" isNullable="true"/>
<field id="2" name="Status" type="LoadControlEventStatusEnum"/>
<field id="3" name="Criticality" type="CriticalityLevelEnum"/>
<field id="4" name="Control" type="EventControlBitmap"/>
<field id="5" name="TemperatureControl" type="TemperatureControlStruct" isNullable="true" optional="true" />
<field id="6" name="AverageLoadControl" type="AverageLoadControlStruct" isNullable="true" optional="true" />
<field id="7" name="DutyCycleControl" type="DutyCycleControlStruct" isNullable="true" optional="true" />
<field id="8" name="PowerSavingsControl" type="PowerSavingsControlStruct" isNullable="true" optional="true" />
<field id="9" name="HeatingSourceControl" type="HeatingSourceControlStruct" isNullable="true" optional="true" />
<!-- Spec has an invalid field ID that cannot be used, so not enabling the Signature field for now. See
https://github.com/CHIP-Specifications/connectedhomeip-spec/issues/8515 -->
<!-- <field id="0xFF" name="Signature" type="octet_string" length="48" isNullable="true"/> -->
</event>
</cluster>