| # Copyright (c) 2024 Project CHIP Authors |
| # All rights reserved. |
| # |
| # Licensed under the Apache License, Version 2.0 (the "License"); |
| # you may not use this file except in compliance with the License. |
| # You may obtain a copy of the License at |
| # |
| # http://www.apache.org/licenses/LICENSE-2.0 |
| # |
| # Unless required by applicable law or agreed to in writing, software |
| # distributed under the License is distributed on an "AS IS" BASIS, |
| # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| # See the License for the specific language governing permissions and |
| # limitations under the License. |
| |
| # See https://github.com/project-chip/connectedhomeip/blob/master/docs/testing/python.md#defining-the-ci-test-arguments |
| # for details about the block below. |
| # |
| # === BEGIN CI TEST ARGUMENTS === |
| # test-runner-runs: run1 |
| # test-runner-run/run1/app: ${ENERGY_MANAGEMENT_APP} |
| # test-runner-run/run1/factoryreset: True |
| # test-runner-run/run1/quiet: True |
| # test-runner-run/run1/app-args: --discriminator 1234 --KVS kvs1 --trace-to json:${TRACE_APP}.json --enable-key 000102030405060708090a0b0c0d0e0f |
| # test-runner-run/run1/script-args: --storage-path admin_storage.json --commissioning-method on-network --discriminator 1234 --passcode 20202021 --hex-arg enableKey:000102030405060708090a0b0c0d0e0f --endpoint 1 --trace-to json:${TRACE_TEST_JSON}.json --trace-to perfetto:${TRACE_TEST_PERFETTO}.perfetto |
| # === END CI TEST ARGUMENTS === |
| |
| import logging |
| import time |
| |
| from matter_testing_support import MatterBaseTest, TestStep, async_test_body, default_matter_test_main |
| from mobly import asserts |
| from TC_EnergyReporting_Utils import EnergyReportingBaseTestHelper |
| |
| logger = logging.getLogger(__name__) |
| |
| |
| class TC_EPM_2_2(MatterBaseTest, EnergyReportingBaseTestHelper): |
| |
| def desc_TC_EPM_2_2(self) -> str: |
| """Returns a description of this test""" |
| return "5.1.3. [TC-EPM-2.2] Primary functionality with DUT as Server" |
| |
| def pics_TC_EPM_2_2(self): |
| """ This function returns a list of PICS for this test case that must be True for the test to be run""" |
| # In this case - there is no feature flags needed to run this test case |
| return ["EPM.S"] |
| |
| def steps_TC_EPM_2_2(self) -> list[TestStep]: |
| steps = [ |
| TestStep("1", "Commissioning, already done", |
| is_commissioning=True), |
| TestStep("2", "TH reads TestEventTriggersEnabled attribute from General Diagnostics Cluster", |
| "Verify that TestEventTriggersEnabled attribute has a value of 1 (True)"), |
| TestStep("3", "TH sends TestEventTrigger command to General Diagnostics Cluster on Endpoint 0 with EnableKey field set to PIXIT.EPM.TEST_EVENT_TRIGGER_KEY and EventTrigger field set to PIXIT.EPM.TEST_EVENT_TRIGGER for Start Fake Load Test 1kW Event"), |
| TestStep("4", "Wait 3 seconds"), |
| TestStep("4a", "TH reads from the DUT the ActivePower attribute", |
| "Verify the read is successful and that the value is between 980'000 and 1'020'000 mW. Note the value read."), |
| TestStep("4b", "TH reads from the DUT the ActiveCurrent attribute", |
| "Verify the read is successful and that the value is between 3'848 and 4'848 mA. Note the value read."), |
| TestStep("4c", "TH reads from the DUT the Voltage attribute", |
| "Verify the read is successful and that the value is between 229'000 and 231'000 mV. Note the value read."), |
| TestStep("5", "Wait 5 seconds"), |
| TestStep("5a", "TH reads from the DUT the ActivePower attribute", |
| "Verify the read is successful, that the value is between '980'000 and 1'020'000 mW, and the value is different from the value read in step 4a."), |
| TestStep("5b", "TH reads from the DUT the ActiveCurrent attribute", |
| "Verify the read is successful, that the value is between 3'848 and 4'848 mA, and the value is different from the value read in step 4b."), |
| TestStep("5c", "TH reads from the DUT the Voltage attribute", |
| "Verify the read is successful, that the value is between 229'000 and 231'000 mV, and the value is different from the value read in step 4c."), |
| TestStep("6", "TH sends TestEventTrigger command to General Diagnostics Cluster on Endpoint 0 with EnableKey field set to PIXIT.EPM.TEST_EVENT_TRIGGER_KEY and EventTrigger field set to PIXIT.EPM.TEST_EVENT_TRIGGER for Stop Fake Readings Test Event."), |
| ] |
| |
| return steps |
| |
| @async_test_body |
| async def test_TC_EPM_2_2(self): |
| |
| self.step("1") |
| # Commission DUT - already done |
| |
| self.step("2") |
| await self.check_test_event_triggers_enabled() |
| |
| self.step("3") |
| await self.send_test_event_trigger_start_fake_1kw_load_2s() |
| |
| # After 3 seconds... |
| self.step("4") |
| time.sleep(3) |
| |
| self.step("4a") |
| # Active power is Mandatory |
| # 1kW +/- 20W |
| active_power = await self.check_epm_attribute_in_range("ActivePower", 980000, 1020000) |
| |
| self.step("4b") |
| if self.pics_guard(self.check_pics("EPM.S.A0005")): |
| # 4.348 A +/- 500mA |
| active_current = await self.check_epm_attribute_in_range("ActiveCurrent", 3848, 4848) |
| |
| self.step("4c") |
| if self.pics_guard(self.check_pics("EPM.S.A0004")): |
| # 230V +/- 1V |
| voltage = await self.check_epm_attribute_in_range("Voltage", 229000, 231000) |
| |
| self.step("5") |
| # After 5 seconds... |
| time.sleep(5) |
| |
| self.step("5a") |
| # Active power is Mandatory |
| # 1kW +/- 20W |
| active_power2 = await self.check_epm_attribute_in_range("ActivePower", 980000, 1020000) |
| asserts.assert_not_equal(active_power, active_power2, |
| f"Expected ActivePower readings to have changed {active_power}, {active_power2}") |
| |
| self.step("5b") |
| if self.pics_guard(self.check_pics("EPM.S.A0005")): |
| # 4.348 A +/- 500mA |
| active_current2 = await self.check_epm_attribute_in_range("ActiveCurrent", 3848, 4848) |
| asserts.assert_not_equal(active_current, active_current2, |
| f"Expected ActiveCurrent readings to have changed {active_current}, {active_current2}") |
| |
| self.step("5c") |
| if self.pics_guard(self.check_pics("EPM.S.A0004")): |
| # 230V +/- 1V |
| voltage2 = await self.check_epm_attribute_in_range("Voltage", 229000, 231000) |
| asserts.assert_not_equal( |
| voltage, voltage2, f"Expected Voltage readings to have changed {voltage}, {voltage2}") |
| |
| self.step("6") |
| await self.send_test_event_trigger_stop_fake_readings() |
| |
| |
| if __name__ == "__main__": |
| default_matter_test_main() |