name: 80.3.4. [TC-MOD-3.4] OnMode Overwriting StartUpMode (DUT as Server)
PICS:
- MOD.S.A0004
- MOD.S.A0005
- OO.S.A4003
config:
nodeId: 0x12344321
cluster: "Mode Select"
endpoint: 1
#Configure newmode value
Step2dOnModeValue:
type: int8u
defaultValue: 4
tests:
- label:
"Step 0: Commission DUT to TH (can be skipped if done in a preceding
test)."
cluster: "DelayCommands"
command: "WaitForCommissionee"
arguments:
values:
- name: "nodeId"
value: nodeId
- label: "Step 1: TH reads from the DUT the StartUpMode attribute."
PICS: MOD.S.A0004
command: "readAttribute"
attribute: "StartUpMode"
response:
saveAs: startup_mode_dut
- label: "Step 2a: TH reads from the DUT the OnMode attribute."
PICS: MOD.S.A0005
command: "readAttribute"
attribute: "OnMode"
response:
saveAs: on_mode_dut
- label:
"Step 2b: If the StartUpMode and OnMode attributes have the same
value, proceed to step 2c, Otherwise proceed to step 3."
PICS: MOD.S.A0004 && MOD.S.A0005
cluster: "EqualityCommands"
command: "UnsignedNumberEquals"
arguments:
values:
- name: "Value1"
value: startup_mode_dut
- name: "Value2"
value: on_mode_dut
response:
- values:
- name: "Equals"
saveAs: IsExpectedValue
- label: "Step 2c: TH reads the SupportedModes attribute from the DUT"
runIf: IsExpectedValue
PICS: MOD.S.A0002
command: "readAttribute"
attribute: "SupportedModes"
response:
constraints:
type: list
- label:
"Step 2d: Select a value from the list in step 2c with a different
value than the StartUpMode value read in step 1. TH sends a write
command for OnMode to the DUT with the selected value."
runIf: IsExpectedValue
PICS: MOD.S.A0002 && MOD.S.C00.Rsp
command: "writeAttribute"
attribute: "OnMode"
arguments:
value: Step2dOnModeValue
- label: "Step 3: TH reads from the DUT the OnMode attribute."
PICS: MOD.S.A0005 && MOD.S.F00
command: "readAttribute"
attribute: "OnMode"
response:
saveAs: Step3OnModeValue
- label:
"Step 4: TH writes 1 to StartUpOnOff attribute of the OnOff Cluster of
the DUT"
PICS: OO.S.A4003
cluster: "On/Off"
command: "writeAttribute"
attribute: "StartUpOnOff"
arguments:
value: 1
- label: "Step 5: Physically power cycle the device"
verification: |
Physically power cycle the device.
cluster: "LogCommands"
command: "UserPrompt"
PICS: PICS_USER_PROMPT
arguments:
values:
- name: "message"
value: "Please enter 'y' for success"
- name: "expectedValue"
value: "y"
- label: "Wait for the commissioned device to be retrieved"
cluster: "DelayCommands"
command: "WaitForCommissionee"
arguments:
values:
- name: "nodeId"
value: nodeId
- label: "Step 6: TH reads from the DUT the CurrentMode attribute."
PICS: MOD.S.A0003 && PICS_USER_PROMPT
command: "readAttribute"
attribute: "CurrentMode"
response: