| # Copyright (c), 2021 NXP |
| # SPDX -License-Identifier: Apache-2.0 |
| |
| description: | |
| NXP PCA9420 PMIC |
| |
| The PMIC has two buck converters and two LDOs. All need to be defined as |
| children nodes, strictly following the BUCK1, BUCK2, LDO1 and LDO2 node names. |
| For example: |
| |
| pmic@61 { |
| reg = <0x61>; |
| ... |
| BUCK1 { |
| /* all properties for BUCK1 */ |
| }; |
| BUCK2 { |
| /* all properties for BUCK2 */ |
| }; |
| LDO1 { |
| /* all properties for LDO1 */ |
| }; |
| LDO2 { |
| /* all properties for LDO2 */ |
| }; |
| }; |
| |
| |
| compatible: "nxp,pca9420" |
| |
| include: base.yaml |
| |
| properties: |
| nxp,enable-modesel-pins: |
| type: boolean |
| description: |
| When enabled, the PMIC will be configured to allow mode selection using |
| the MODESEL0/1 inputs. |
| |
| nxp,vin-ilim-microamp: |
| type: int |
| default: 425000 |
| enum: |
| - 85000 |
| - 255000 |
| - 425000 |
| - 595000 |
| - 765000 |
| - 935000 |
| - 1105000 |
| description: | |
| VIN input current limit, in microamperes. Value reflects typical value, |
| below you can find min/typical/max values: |
| |
| - 74 mA/85 mA/98 mA |
| - 222 mA/255 mA/293 mA |
| - 370 mA/425 mA/489 mA |
| - 517 mA/595 mA/684 mA |
| - 665 mA/765 mA/880 mA |
| - 813 mA/935 mA/1075 mA |
| - 961 mA/1105 mA/1271 mA |
| |
| To disable current limit, set property to zero. Defaults to 425mA, the IC |
| default value. |
| |
| child-binding: |
| include: |
| - name: regulator.yaml |
| property-allowlist: |
| - regulator-always-on |
| - regulator-boot-on |
| - regulator-min-microvolt |
| - regulator-max-microvolt |
| |
| description: Voltage output of PMIC controller regulator |
| properties: |
| enable-inverted: |
| type: boolean |
| description: | |
| If the enable bit should be zero to turn the regulator on, add this |
| property. |
| |
| nxp,mode0-microvolt: |
| type: int |
| description: | |
| The voltage level to be configured for mode 0, in microvolts. Setting |
| this value to zero will disable the source in mode 0. |
| |
| nxp,mode1-microvolt: |
| type: int |
| description: | |
| The voltage level to be configured for mode 1, in microvolts. Setting |
| this value to zero will disable the source in mode 1. |
| |
| nxp,mode2-microvolt: |
| type: int |
| description: | |
| The voltage level to be configured for mode 2, in microvolts. Setting |
| this value to zero will disable the source in mode 2. |
| |
| nxp,mode3-microvolt: |
| type: int |
| description: | |
| The voltage level to be configured for mode 3, in microvolts. Setting |
| this value to zero will disable the source in mode 3. |