| * Copyright (c) 2023 Alvaro Garcia Gomez <maxpowel@gmail.com> |
| * |
| * SPDX-License-Identifier: Apache-2.0 |
| */ |
| |
| #include <zephyr/device.h> |
| #include <zephyr/drivers/fuel_gauge.h> |
| #include <zephyr/drivers/i2c.h> |
| #include <zephyr/logging/log.h> |
| #include <zephyr/sys/byteorder.h> |
| #include <zephyr/sys/util.h> |
| #include <zephyr/ztest.h> |
| #include <zephyr/ztest_assert.h> |
| |
| struct max17048_fixture { |
| const struct device *dev; |
| const struct fuel_gauge_driver_api *api; |
| }; |
| |
| void emul_max17048_set_crate_status(int value); |
| |
| static void *max17048_setup(void) |
| { |
| static ZTEST_DMEM struct max17048_fixture fixture; |
| |
| fixture.dev = DEVICE_DT_GET_ANY(maxim_max17048); |
| k_object_access_all_grant(fixture.dev); |
| |
| zassert_true(device_is_ready(fixture.dev), "Fuel Gauge not found"); |
| |
| return &fixture; |
| } |
| |
| ZTEST_USER_F(max17048, test_get_some_props_failed_returns_bad_status) |
| { |
| fuel_gauge_prop_t prop_types[] = { |
| /* First invalid property */ |
| FUEL_GAUGE_PROP_MAX, |
| /* Second invalid property */ |
| FUEL_GAUGE_PROP_MAX, |
| /* Valid property */ |
| FUEL_GAUGE_VOLTAGE, |
| }; |
| union fuel_gauge_prop_val props[ARRAY_SIZE(prop_types)]; |
| |
| int ret = fuel_gauge_get_props(fixture->dev, prop_types, props, ARRAY_SIZE(props)); |
| |
| zassert_equal(ret, -ENOTSUP, "Getting bad property has a good status."); |
| } |
| |
| ZTEST_USER_F(max17048, test_get_props__returns_ok) |
| { |
| /* Validate what props are supported by the driver */ |
| |
| fuel_gauge_prop_t prop_types[] = { |
| FUEL_GAUGE_VOLTAGE, |
| FUEL_GAUGE_RUNTIME_TO_EMPTY, |
| FUEL_GAUGE_RUNTIME_TO_FULL, |
| FUEL_GAUGE_RELATIVE_STATE_OF_CHARGE, |
| }; |
| |
| union fuel_gauge_prop_val props[ARRAY_SIZE(prop_types)]; |
| |
| zassert_ok(fuel_gauge_get_props(fixture->dev, prop_types, props, ARRAY_SIZE(props))); |
| } |
| |
| ZTEST_USER_F(max17048, test_current_rate_zero) |
| { |
| /* Test when crate is 0, which is a special case */ |
| |
| fuel_gauge_prop_t prop_types[] = { |
| FUEL_GAUGE_RUNTIME_TO_EMPTY, |
| FUEL_GAUGE_RUNTIME_TO_FULL, |
| }; |
| union fuel_gauge_prop_val props[ARRAY_SIZE(prop_types)]; |
| |
| /** Null value, not charging either discharging. If not handled correctly, |
| * it will cause a division by zero |
| */ |
| emul_max17048_set_crate_status(0); |
| int ret = fuel_gauge_get_props(fixture->dev, prop_types, props, ARRAY_SIZE(props)); |
| |
| zassert_equal(props[0].runtime_to_empty, 0, "Runtime to empty is %d but it should be 0.", |
| props[0].runtime_to_full); |
| zassert_equal(props[1].runtime_to_full, 0, "Runtime to full is %d but it should be 0.", |
| props[1].runtime_to_full); |
| |
| zassert_ok(ret); |
| /* Return value to the original state */ |
| emul_max17048_set_crate_status(0x4000); |
| } |
| |
| ZTEST_SUITE(max17048, NULL, max17048_setup, NULL, NULL, NULL); |