| # Copyright 2021 Grinn |
| # |
| # SPDX-License-Identifier: Apache-2.0 |
| # |
| |
| description: | |
| TI INA237 Bidirectional Current and Power Monitor. |
| The <zephyr/dt-bindings/sensor/ina237.h> file should be included in the |
| DeviceTree and it provides macros that can be used for initializing the |
| configuration registers. |
| |
| compatible: "ti,ina237" |
| |
| include: ti,ina23x-common.yaml |
| |
| properties: |
| config: |
| type: int |
| deprecated: true |
| default: 0x0000 |
| description: | |
| Value of the configuration register |
| e.g shunt voltage and bus voltage ADC conversion |
| times and averaging, operating mode for INA230 or |
| delay for initial ADC conversion, shunt full scale range |
| for INA237. |
| |
| Deprecated, please use new properties instead. |
| |
| adc-config: |
| type: int |
| deprecated: true |
| default: 0x0000 |
| description: | |
| Value of the ADC configuration register (ADC conversion times, |
| averaging, operating mode and etc). |
| |
| Deprecated, please use new properties instead. |
| |
| alert-config: |
| type: int |
| description: Diag alert register, default matches the power-on reset value |
| |
| adc-mode: |
| type: string |
| description: | |
| ADC channel conversion configuration. |
| Default is the power-on reset value. |
| default: "Temperature, bus, and shunt voltage continuous" |
| enum: |
| - "Shutdown single shot" |
| - "Bus Voltage single shot" |
| - "Shunt Voltage single shot" |
| - "Bus and Shunt Voltage single shot" |
| - "Temperature Single shot" |
| - "Temperature and bus voltage single shot" |
| - "Temperature and shunt voltage single shot" |
| - "Temperature, bus, and shunt voltage single shot" |
| - "Shutdown continuous" |
| - "Bus voltage continuous" |
| - "Shunt voltage continuous" |
| - "Bus and shunt voltage continuous" |
| - "Temperature continuous" |
| - "Temperature and bus voltage continuous" |
| - "Temperature and shunt voltage continuous" |
| - "Temperature, bus, and shunt voltage continuous" |
| |
| vbus-conversion-time-us: |
| type: int |
| description: | |
| Vbus conversion time in microseconds. |
| Default is the power-on reset value. |
| default: 1052 |
| enum: [50, 84, 150, 280, 540, 1052, 2074, 4120] |
| |
| vshunt-conversion-time-us: |
| type: int |
| description: | |
| Vshunt conversion time in microseconds. |
| Default is the power-on reset value. |
| default: 1052 |
| enum: [50, 84, 150, 280, 540, 1052, 2074, 4120] |
| |
| temp-conversion-time-us: |
| type: int |
| description: | |
| Temperature conversion time in microseconds. |
| Default is the power-on reset value. |
| default: 1052 |
| enum: [50, 84, 150, 280, 540, 1052, 2074, 4120] |
| |
| avg-count: |
| type: int |
| description: | |
| Number of samples to average (applies to all inputs). |
| Default is the power-on reset value. |
| default: 1 |
| enum: [1, 4, 16, 64, 128, 256, 512, 1024] |
| |
| high-precision: |
| type: boolean |
| description: | |
| Enable high precision mode (4x the resolution). |