| .. _lps22hh_i3c: |
| |
| LPS22HH: Temperature and Pressure Monitor (I3C) |
| ############################################### |
| |
| Overview |
| ******** |
| This sample periodically reads pressure from the LPS22HH MEMS pressure |
| sensor and displays it on the console. |
| |
| Requirements |
| ************ |
| |
| This sample uses the LPS22HH sensor controlled using the I3C interface. |
| It has been tested using the LPS22HH on the evaluation board |
| STEVALMKI192-V1 connected to the I3C header on :ref:`mimxrt685_evk`. |
| |
| References |
| ********** |
| |
| - LPS22HH: http://www.st.com/en/mems-and-sensors/lps22hh.html |
| |
| Building and Running |
| ******************** |
| |
| This project outputs sensor data to the console. It requires an LPS22HH |
| sensor (for example, the one on evaluation board STEVALMKI192-V1). |
| |
| .. note:: |
| |
| If ``CONFIG_LPS22HH_TRIGGER`` is enabled, the trigger is using |
| I3C In-Band Interrupt (IBI) to signal new data being available. |
| Since IBI is initiated by the sensor, it will take over the I3C |
| bus. Therefore, when flashing a new image, a power cycle is needed |
| to reset the sensor so that it will not generate IBIs anymore. |
| Or else the I3C controller will not be able to be initialized, |
| resulting in the sample not being able to communicate with |
| the sensor. |
| |
| Building on mimxrt685_evk_cm33 board |
| ==================================== |
| |
| .. zephyr-app-commands:: |
| :zephyr-app: samples/sensor/lps22hh_i3c |
| :host-os: unix |
| :board: mimxrt685_evk_cm33 |
| :goals: build |
| :compact: |
| |
| Board Preparations |
| ================== |
| |
| mimxrt685_evk_cm33 |
| ------------------ |
| |
| On the board :ref:`mimxrt685_evk`, the I3C pins are exposed on the J18 |
| header, where: |
| |
| * SCL is on pin 1 |
| * SDA is on pin 2 |
| * Internal pull-up is on pin 3 (which is connected to pin 2 already) |
| * Ground is on pin4 |
| |
| LPS22HH |
| ^^^^^^^ |
| |
| A LPS22HH sensor needs to be connected to this header. For example, |
| the evaluation board STEVAL-MKI192V1 can be used. This needs to be |
| prepared so that the LPS22HH sensor has address 0x5D (i.e. 0xBA, |
| left-shifed). |
| |
| Sample Output |
| ============= |
| |
| .. code-block:: console |
| |
| Configured for triggered collection at 1 Hz |
| Observation: 1 |
| Pressure: 97.474 kPa |
| Temperature: 22.19 C |
| Observation: 2 |
| Pressure: 97.466 kPa |
| Temperature: 22.21 C |
| Observation: 3 |
| Pressure: 97.473 kPa |
| Temperature: 22.21 C |
| Observation: 4 |
| Pressure: 97.455 kPa |
| Temperature: 22.21 C |
| |
| <repeats endlessly every second> |