| .. _ams_iaqcore: |
| |
| ams iAQcore Indoor air quality sensor |
| ##################################### |
| |
| Overview |
| ******** |
| |
| This sample application demonstrates how to use the ams iAQcore sensor to |
| measure CO2 equivalent and VOC. The CO2 value is a predicted value derived from |
| VOC. The values are fetched and printed every second. |
| |
| Building and Running |
| ******************** |
| |
| This sample application uses the sensor connected to the i2c stated in the |
| iaq_core.overlay file. |
| Flash the binary to a board of choice with a sensor connected. |
| This sample can run on every board with i2c. |
| For example build for a nucleo_f446re board: |
| |
| .. zephyr-app-commands:: |
| :zephyr-app: samples/sensor/ams_iAQcore |
| :board: nucleo_f446re |
| :goals: build flash |
| :compact: |
| |
| Sample Output |
| ============= |
| |
| .. code-block:: console |
| |
| device is 0x20001a08, name is IAQ_CORE |
| Co2: 882.000000ppm; VOC: 244.000000ppb |
| Co2: 863.000000ppm; VOC: 239.000000ppb |
| Co2: 836.000000ppm; VOC: 232.000000ppb |