blob: 18bc00079a0dec5c58f5adad36aece8560f44578 [file] [log] [blame]
<?xml version="1.0" encoding="UTF-8"?>
<device schemaVersion="1.1" xmlns:xs="http://www.w3.org/2001/XMLSchema-instance" xs:noNamespaceSchemaLocation="CMSIS-SVD_Schema_1_1.xsd">
<vendor>Freescale Semiconductor, Inc.</vendor>
<vendorID>Freescale</vendorID>
<series>Kinetis_W</series>
<name>MKW40Z4</name>
<version>1.6</version>
<description>MKW40Z4 Freescale Microcontroller</description>
<licenseText>Redistribution and use in source and binary forms, with or without modification,\nare permitted provided that the following conditions are met:\n o Redistributions of source code must retain the above copyright notice, this list\n of conditions and the following disclaimer.\n o Redistributions in binary form must reproduce the above copyright notice, this\n list of conditions and the following disclaimer in the documentation and/or\n other materials provided with the distribution.\n o Neither the name of Freescale Semiconductor, Inc. nor the names of its\n contributors may be used to endorse or promote products derived from this\n software without specific prior written permission.\n THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS &quot;AS IS&quot; AND\n ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED\n WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE\n DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR\n ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES\n (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;\n LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON\n ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT\n (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS\n SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.</licenseText>
<cpu>
<name>CM0PLUS</name>
<revision>r0p0</revision>
<endian>little</endian>
<mpuPresent>false</mpuPresent>
<fpuPresent>false</fpuPresent>
<mpuPresent>false</mpuPresent>
<vtorPresent>true</vtorPresent>
<nvicPrioBits>2</nvicPrioBits>
<vendorSystickConfig>false</vendorSystickConfig>
</cpu>
<addressUnitBits>8</addressUnitBits>
<width>32</width>
<peripherals>
<peripheral>
<name>FTFA_FlashConfig</name>
<description>Flash configuration field</description>
<prependToName>NV_</prependToName>
<baseAddress>0x400</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0xE</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>BACKKEY3</name>
<description>Backdoor Comparison Key 3.</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>KEY</name>
<description>Backdoor Comparison Key.</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>BACKKEY2</name>
<description>Backdoor Comparison Key 2.</description>
<addressOffset>0x1</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>KEY</name>
<description>Backdoor Comparison Key.</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>BACKKEY1</name>
<description>Backdoor Comparison Key 1.</description>
<addressOffset>0x2</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>KEY</name>
<description>Backdoor Comparison Key.</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>BACKKEY0</name>
<description>Backdoor Comparison Key 0.</description>
<addressOffset>0x3</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>KEY</name>
<description>Backdoor Comparison Key.</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>BACKKEY7</name>
<description>Backdoor Comparison Key 7.</description>
<addressOffset>0x4</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>KEY</name>
<description>Backdoor Comparison Key.</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>BACKKEY6</name>
<description>Backdoor Comparison Key 6.</description>
<addressOffset>0x5</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>KEY</name>
<description>Backdoor Comparison Key.</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>BACKKEY5</name>
<description>Backdoor Comparison Key 5.</description>
<addressOffset>0x6</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>KEY</name>
<description>Backdoor Comparison Key.</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>BACKKEY4</name>
<description>Backdoor Comparison Key 4.</description>
<addressOffset>0x7</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>KEY</name>
<description>Backdoor Comparison Key.</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>FPROT3</name>
<description>Non-volatile P-Flash Protection 1 - Low Register</description>
<addressOffset>0x8</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>PROT</name>
<description>P-Flash Region Protect</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>FPROT2</name>
<description>Non-volatile P-Flash Protection 1 - High Register</description>
<addressOffset>0x9</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>PROT</name>
<description>P-Flash Region Protect</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>FPROT1</name>
<description>Non-volatile P-Flash Protection 0 - Low Register</description>
<addressOffset>0xA</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>PROT</name>
<description>P-Flash Region Protect</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>FPROT0</name>
<description>Non-volatile P-Flash Protection 0 - High Register</description>
<addressOffset>0xB</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>PROT</name>
<description>P-Flash Region Protect</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>FSEC</name>
<description>Non-volatile Flash Security Register</description>
<addressOffset>0xC</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>SEC</name>
<description>Flash Security</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>10</name>
<description>MCU security status is unsecure</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>MCU security status is secure</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FSLACC</name>
<description>Freescale Failure Analysis Access Code</description>
<bitOffset>2</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>10</name>
<description>Freescale factory access denied</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Freescale factory access granted</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MEEN</name>
<description>no description available</description>
<bitOffset>4</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>10</name>
<description>Mass erase is disabled</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Mass erase is enabled</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>KEYEN</name>
<description>Backdoor Key Security Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>10</name>
<description>Backdoor key access enabled</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Backdoor key access disabled</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FOPT</name>
<description>Non-volatile Flash Option Register</description>
<addressOffset>0xD</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>LPBOOT0</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Core and system clock divider (OUTDIV1) is 0x7 (divide by 8) when LPBOOT1=0 or 0x1 (divide by 2) when LPBOOT1=1.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Core and system clock divider (OUTDIV1) is 0x3 (divide by 4) when LPBOOT1=0 or 0x0 (divide by 1) when LPBOOT1=1.</description>
<value>#01</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>NMI_DIS</name>
<description>no description available</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>NMI interrupts are always blocked</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>NMI_b pin/interrupts reset default to enabled</description>
<value>#01</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RESET_PIN_CFG</name>
<description>no description available</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>RESET pin is disabled following a POR and cannot be enabled as reset function</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>RESET_b pin is dedicated</description>
<value>#01</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LPBOOT1</name>
<description>no description available</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Core and system clock divider (OUTDIV1) is 0x7 (divide by 8) when LPBOOT0=0 or 0x3 (divide by 4) when LPBOOT0=1.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Core and system clock divider (OUTDIV1) is 0x1 (divide by 2) when LPBOOT0=0 or 0x0 (divide by 1) when LPBOOT0=1.</description>
<value>#01</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FAST_INIT</name>
<description>no description available</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Slower initialization</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Fast Initialization</description>
<value>#01</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>DMA</name>
<description>DMA Controller</description>
<prependToName>DMA_</prependToName>
<baseAddress>0x40008000</baseAddress>
<addressBlock>
<offset>0x100</offset>
<size>0x40</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>DMA0</name>
<value>0</value>
</interrupt>
<interrupt>
<name>DMA1</name>
<value>1</value>
</interrupt>
<interrupt>
<name>DMA2</name>
<value>2</value>
</interrupt>
<interrupt>
<name>DMA3</name>
<value>3</value>
</interrupt>
<registers>
<register>
<dim>4</dim>
<dimIncrement>0x10</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>SAR%s</name>
<description>Source Address Register</description>
<addressOffset>0x100</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>SAR</name>
<description>SAR</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x10</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>DAR%s</name>
<description>Destination Address Register</description>
<addressOffset>0x104</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DAR</name>
<description>DAR</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x10</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>DSR_BCR%s</name>
<description>DMA Status Register / Byte Count Register</description>
<addressOffset>0x108</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>BCR</name>
<description>BCR</description>
<bitOffset>0</bitOffset>
<bitWidth>24</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DONE</name>
<description>Transactions Done</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DMA transfer is not yet complete. Writing a 0 has no effect.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA transfer completed. Writing a 1 to this bit clears all DMA status bits and should be used in an interrupt service routine to clear the DMA interrupt and error bits.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>BSY</name>
<description>Busy</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DMA channel is inactive. Cleared when the DMA has finished the last transaction.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>BSY is set the first time the channel is enabled after a transfer is initiated.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>REQ</name>
<description>Request</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No request is pending or the channel is currently active. Cleared when the channel is selected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DMA channel has a transfer remaining and the channel is not selected.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>BED</name>
<description>Bus Error on Destination</description>
<bitOffset>28</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No bus error occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DMA channel terminated with a bus error during the write portion of a transfer.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>BES</name>
<description>Bus Error on Source</description>
<bitOffset>29</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No bus error occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DMA channel terminated with a bus error during the read portion of a transfer.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CE</name>
<description>Configuration Error</description>
<bitOffset>30</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No configuration error exists.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A configuration error has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x10</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>DCR%s</name>
<description>DMA Control Register</description>
<addressOffset>0x10C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>LCH2</name>
<description>Link Channel 2</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>DMA Channel 0</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>DMA Channel 1</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>DMA Channel 2</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>DMA Channel 3</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LCH1</name>
<description>Link Channel 1</description>
<bitOffset>2</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>DMA Channel 0</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>DMA Channel 1</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>DMA Channel 2</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>DMA Channel 3</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LINKCC</name>
<description>Link Channel Control</description>
<bitOffset>4</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>No channel-to-channel linking</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Perform a link to channel LCH1 after each cycle-steal transfer followed by a link to LCH2 after the BCR decrements to 0.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Perform a link to channel LCH1 after each cycle-steal transfer</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Perform a link to channel LCH1 after the BCR decrements to 0.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>D_REQ</name>
<description>Disable Request</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>ERQ bit is not affected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>ERQ bit is cleared when the BCR is exhausted.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DMOD</name>
<description>Destination Address Modulo</description>
<bitOffset>8</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Buffer disabled</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0001</name>
<description>Circular buffer size is 16 bytes</description>
<value>#0001</value>
</enumeratedValue>
<enumeratedValue>
<name>0010</name>
<description>Circular buffer size is 32 bytes</description>
<value>#0010</value>
</enumeratedValue>
<enumeratedValue>
<name>0011</name>
<description>Circular buffer size is 64 bytes</description>
<value>#0011</value>
</enumeratedValue>
<enumeratedValue>
<name>0100</name>
<description>Circular buffer size is 128 bytes</description>
<value>#0100</value>
</enumeratedValue>
<enumeratedValue>
<name>0101</name>
<description>Circular buffer size is 256 bytes</description>
<value>#0101</value>
</enumeratedValue>
<enumeratedValue>
<name>0110</name>
<description>Circular buffer size is 512 bytes</description>
<value>#0110</value>
</enumeratedValue>
<enumeratedValue>
<name>0111</name>
<description>Circular buffer size is 1 KB</description>
<value>#0111</value>
</enumeratedValue>
<enumeratedValue>
<name>1000</name>
<description>Circular buffer size is 2 KB</description>
<value>#1000</value>
</enumeratedValue>
<enumeratedValue>
<name>1001</name>
<description>Circular buffer size is 4 KB</description>
<value>#1001</value>
</enumeratedValue>
<enumeratedValue>
<name>1010</name>
<description>Circular buffer size is 8 KB</description>
<value>#1010</value>
</enumeratedValue>
<enumeratedValue>
<name>1011</name>
<description>Circular buffer size is 16 KB</description>
<value>#1011</value>
</enumeratedValue>
<enumeratedValue>
<name>1100</name>
<description>Circular buffer size is 32 KB</description>
<value>#1100</value>
</enumeratedValue>
<enumeratedValue>
<name>1101</name>
<description>Circular buffer size is 64 KB</description>
<value>#1101</value>
</enumeratedValue>
<enumeratedValue>
<name>1110</name>
<description>Circular buffer size is 128 KB</description>
<value>#1110</value>
</enumeratedValue>
<enumeratedValue>
<name>1111</name>
<description>Circular buffer size is 256 KB</description>
<value>#1111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SMOD</name>
<description>Source Address Modulo</description>
<bitOffset>12</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Buffer disabled</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0001</name>
<description>Circular buffer size is 16 bytes.</description>
<value>#0001</value>
</enumeratedValue>
<enumeratedValue>
<name>0010</name>
<description>Circular buffer size is 32 bytes.</description>
<value>#0010</value>
</enumeratedValue>
<enumeratedValue>
<name>0011</name>
<description>Circular buffer size is 64 bytes.</description>
<value>#0011</value>
</enumeratedValue>
<enumeratedValue>
<name>0100</name>
<description>Circular buffer size is 128 bytes.</description>
<value>#0100</value>
</enumeratedValue>
<enumeratedValue>
<name>0101</name>
<description>Circular buffer size is 256 bytes.</description>
<value>#0101</value>
</enumeratedValue>
<enumeratedValue>
<name>0110</name>
<description>Circular buffer size is 512 bytes.</description>
<value>#0110</value>
</enumeratedValue>
<enumeratedValue>
<name>0111</name>
<description>Circular buffer size is 1 KB.</description>
<value>#0111</value>
</enumeratedValue>
<enumeratedValue>
<name>1000</name>
<description>Circular buffer size is 2 KB.</description>
<value>#1000</value>
</enumeratedValue>
<enumeratedValue>
<name>1001</name>
<description>Circular buffer size is 4 KB.</description>
<value>#1001</value>
</enumeratedValue>
<enumeratedValue>
<name>1010</name>
<description>Circular buffer size is 8 KB.</description>
<value>#1010</value>
</enumeratedValue>
<enumeratedValue>
<name>1011</name>
<description>Circular buffer size is 16 KB.</description>
<value>#1011</value>
</enumeratedValue>
<enumeratedValue>
<name>1100</name>
<description>Circular buffer size is 32 KB.</description>
<value>#1100</value>
</enumeratedValue>
<enumeratedValue>
<name>1101</name>
<description>Circular buffer size is 64 KB.</description>
<value>#1101</value>
</enumeratedValue>
<enumeratedValue>
<name>1110</name>
<description>Circular buffer size is 128 KB.</description>
<value>#1110</value>
</enumeratedValue>
<enumeratedValue>
<name>1111</name>
<description>Circular buffer size is 256 KB.</description>
<value>#1111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>START</name>
<description>Start Transfer</description>
<bitOffset>16</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DMA inactive</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DMA begins the transfer in accordance to the values in the TCDn. START is cleared automatically after one module clock and always reads as logic 0.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DSIZE</name>
<description>Destination Size</description>
<bitOffset>17</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>32-bit</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>8-bit</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>16-bit</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Reserved (generates a configuration error (DSRn[CE]) if incorrectly specified at time of channel activation)</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DINC</name>
<description>Destination Increment</description>
<bitOffset>19</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No change to the DAR after a successful transfer.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DAR increments by 1, 2, 4 depending upon the size of the transfer.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SSIZE</name>
<description>Source Size</description>
<bitOffset>20</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>32-bit</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>8-bit</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>16-bit</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Reserved (generates a configuration error (DSRn[CE]) if incorrectly specified at time of channel activation)</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SINC</name>
<description>Source Increment</description>
<bitOffset>22</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No change to SAR after a successful transfer.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The SAR increments by 1, 2, 4 as determined by the transfer size.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EADREQ</name>
<description>Enable asynchronous DMA requests</description>
<bitOffset>23</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>AA</name>
<description>Auto-align</description>
<bitOffset>28</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Auto-align disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>If SSIZE indicates a transfer no smaller than DSIZE, source accesses are auto-aligned; otherwise, destination accesses are auto-aligned. Source alignment takes precedence over destination alignment. If auto-alignment is enabled, the appropriate address register increments, regardless of DINC or SINC.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CS</name>
<description>Cycle Steal</description>
<bitOffset>29</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DMA continuously makes read/write transfers until the BCR decrements to 0.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Forces a single read/write transfer per request.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ERQ</name>
<description>Enable Peripheral Request</description>
<bitOffset>30</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Peripheral request is ignored.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enables peripheral request to initiate transfer. A software-initiated request (setting START) is always enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EINT</name>
<description>Enable Interrupt on Completion of Transfer</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No interrupt is generated.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Interrupt signal is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>FTFA</name>
<description>Flash Memory Interface</description>
<prependToName>FTFA_</prependToName>
<baseAddress>0x40020000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x2C</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>FTFA</name>
<value>5</value>
</interrupt>
<registers>
<register>
<name>FSTAT</name>
<description>Flash Status Register</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>MGSTAT0</name>
<description>Memory Controller Command Completion Status Flag</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
</field>
<field>
<name>FPVIOL</name>
<description>Flash Protection Violation Flag</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No protection violation detected</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Protection violation detected</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ACCERR</name>
<description>Flash Access Error Flag</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No access error detected</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Access error detected</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RDCOLERR</name>
<description>Flash Read Collision Error Flag</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No collision error detected</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Collision error detected</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CCIF</name>
<description>Command Complete Interrupt Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Flash command in progress</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Flash command has completed</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FCNFG</name>
<description>Flash Configuration Register</description>
<addressOffset>0x1</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>ERSSUSP</name>
<description>Erase Suspend</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No suspend requested</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Suspend the current Erase Flash Sector command execution.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ERSAREQ</name>
<description>Erase All Request</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No request or request complete</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Request to: run the Erase All Blocks command, verify the erased state, program the security byte in the Flash Configuration Field to the unsecure state, and release MCU security by setting the FSEC[SEC] field to the unsecure state.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RDCOLLIE</name>
<description>Read Collision Error Interrupt Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Read collision error interrupt disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Read collision error interrupt enabled. An interrupt request is generated whenever a flash memory read collision error is detected (see the description of FSTAT[RDCOLERR]).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CCIE</name>
<description>Command Complete Interrupt Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Command complete interrupt disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Command complete interrupt enabled. An interrupt request is generated whenever the FSTAT[CCIF] flag is set.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FSEC</name>
<description>Flash Security Register</description>
<addressOffset>0x2</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>SEC</name>
<description>Flash Security</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>MCU security status is secure.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>MCU security status is secure.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>MCU security status is unsecure. (The standard shipping condition of the flash memory module is unsecure.)</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>MCU security status is secure.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FSLACC</name>
<description>Freescale Failure Analysis Access Code</description>
<bitOffset>2</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Freescale factory access granted</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Freescale factory access denied</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Freescale factory access denied</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Freescale factory access granted</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MEEN</name>
<description>Mass Erase Enable Bits</description>
<bitOffset>4</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Mass erase is enabled</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Mass erase is enabled</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Mass erase is disabled</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Mass erase is enabled</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>KEYEN</name>
<description>Backdoor Key Security Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Backdoor key access disabled</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Backdoor key access disabled (preferred KEYEN state to disable backdoor key access)</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Backdoor key access enabled</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Backdoor key access disabled</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FOPT</name>
<description>Flash Option Register</description>
<addressOffset>0x3</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>OPT</name>
<description>Nonvolatile Option</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>12</dim>
<dimIncrement>0x1</dimIncrement>
<dimIndex>3,2,1,0,7,6,5,4,B,A,9,8</dimIndex>
<name>FCCOB%s</name>
<description>Flash Common Command Object Registers</description>
<addressOffset>0x4</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>CCOBn</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x1</dimIncrement>
<dimIndex>3,2,1,0</dimIndex>
<name>FPROT%s</name>
<description>Program Flash Protection Registers</description>
<addressOffset>0x10</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>PROT</name>
<description>Program Flash Region Protect</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Program flash region is protected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Program flash region is not protected</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<dim>8</dim>
<dimIncrement>0x1</dimIncrement>
<dimIndex>H3,H2,H1,H0,L3,L2,L1,L0</dimIndex>
<name>XACC%s</name>
<description>Execute-only Access Registers</description>
<addressOffset>0x18</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>XA</name>
<description>Execute-only access control</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Associated segment is accessible in execute mode only (as an instruction fetch)</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Associated segment is accessible as data or in execute mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<dim>8</dim>
<dimIncrement>0x1</dimIncrement>
<dimIndex>H3,H2,H1,H0,L3,L2,L1,L0</dimIndex>
<name>SACC%s</name>
<description>Supervisor-only Access Registers</description>
<addressOffset>0x20</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>SA</name>
<description>Supervisor-only access control</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Associated segment is accessible in supervisor mode only</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Associated segment is accessible in user or supervisor mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FACSS</name>
<description>Flash Access Segment Size Register</description>
<addressOffset>0x28</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>SGSIZE</name>
<description>Segment Size</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>FACSN</name>
<description>Flash Access Segment Number Register</description>
<addressOffset>0x2B</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>NUMSG</name>
<description>Number of Segments Indicator</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>100000</name>
<description>Program flash memory is divided into 32 segments (64 Kbytes, 128 Kbytes)</description>
<value>#100000</value>
</enumeratedValue>
<enumeratedValue>
<name>101000</name>
<description>Program flash memory is divided into 40 segments (160 Kbytes)</description>
<value>#101000</value>
</enumeratedValue>
<enumeratedValue>
<name>1000000</name>
<description>Program flash memory is divided into 64 segments (256 Kbytes, 512 Kbytes)</description>
<value>#1000000</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>DMAMUX</name>
<description>DMA channel multiplexor</description>
<prependToName>DMAMUX_</prependToName>
<baseAddress>0x40021000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x4</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<dim>4</dim>
<dimIncrement>0x1</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>CHCFG%s</name>
<description>Channel Configuration register</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>SOURCE</name>
<description>DMA Channel Source (Slot)</description>
<bitOffset>0</bitOffset>
<bitWidth>6</bitWidth>
<access>read-write</access>
</field>
<field>
<name>TRIG</name>
<description>DMA Channel Trigger Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Triggering is disabled. If triggering is disabled and ENBL is set, the DMA Channel will simply route the specified source to the DMA channel. (Normal mode)</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Triggering is enabled. If triggering is enabled and ENBL is set, the DMAMUX is in Periodic Trigger mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ENBL</name>
<description>DMA Channel Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DMA channel is disabled. This mode is primarily used during configuration of the DMAMux. The DMA has separate channel enables/disables, which should be used to disable or reconfigure a DMA channel.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA channel is enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>SPI0</name>
<description>Serial Peripheral Interface</description>
<groupName>SPI</groupName>
<prependToName>SPI0_</prependToName>
<baseAddress>0x4002C000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x8C</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>SPI0</name>
<value>10</value>
</interrupt>
<registers>
<register>
<name>MCR</name>
<description>Module Configuration Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x4001</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>HALT</name>
<description>Halt</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Start transfers.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Stop transfers.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SMPL_PT</name>
<description>Sample Point</description>
<bitOffset>8</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>0 protocol clock cycles between SCK edge and SIN sample</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>1 protocol clock cycle between SCK edge and SIN sample</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>2 protocol clock cycles between SCK edge and SIN sample</description>
<value>#10</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CLR_RXF</name>
<description>CLR_RXF</description>
<bitOffset>10</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Do not clear the RX FIFO counter.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clear the RX FIFO counter.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CLR_TXF</name>
<description>Clear TX FIFO</description>
<bitOffset>11</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Do not clear the TX FIFO counter.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clear the TX FIFO counter.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DIS_RXF</name>
<description>Disable Receive FIFO</description>
<bitOffset>12</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>RX FIFO is enabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>RX FIFO is disabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DIS_TXF</name>
<description>Disable Transmit FIFO</description>
<bitOffset>13</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TX FIFO is enabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TX FIFO is disabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MDIS</name>
<description>Module Disable</description>
<bitOffset>14</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Enables the module clocks.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Allows external logic to disable the module clocks.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DOZE</name>
<description>Doze Enable</description>
<bitOffset>15</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Doze mode has no effect on the module.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Doze mode disables the module.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PCSIS</name>
<description>Peripheral Chip Select x Inactive State</description>
<bitOffset>16</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The inactive state of PCSx is low.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The inactive state of PCSx is high.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ROOE</name>
<description>Receive FIFO Overflow Overwrite Enable</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Incoming data is ignored.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Incoming data is shifted into the shift register.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MTFE</name>
<description>Modified Timing Format Enable</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Modified SPI transfer format disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Modified SPI transfer format enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FRZ</name>
<description>Freeze</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Do not halt serial transfers in Debug mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Halt serial transfers in Debug mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DCONF</name>
<description>SPI Configuration.</description>
<bitOffset>28</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>SPI</description>
<value>#00</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CONT_SCKE</name>
<description>Continuous SCK Enable</description>
<bitOffset>30</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Continuous SCK disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Continuous SCK enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MSTR</name>
<description>Master/Slave Mode Select</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Enables Slave mode</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enables Master mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>TCR</name>
<description>Transfer Count Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>SPI_TCNT</name>
<description>SPI Transfer Counter</description>
<bitOffset>16</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<dim>2</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1</dimIndex>
<name>CTAR%s</name>
<description>Clock and Transfer Attributes Register (In Master Mode)</description>
<alternateGroup>SPI0</alternateGroup>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x78000000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>BR</name>
<description>Baud Rate Scaler</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DT</name>
<description>Delay After Transfer Scaler</description>
<bitOffset>4</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>ASC</name>
<description>After SCK Delay Scaler</description>
<bitOffset>8</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CSSCK</name>
<description>PCS to SCK Delay Scaler</description>
<bitOffset>12</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>PBR</name>
<description>Baud Rate Prescaler</description>
<bitOffset>16</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Baud Rate Prescaler value is 2.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Baud Rate Prescaler value is 3.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Baud Rate Prescaler value is 5.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Baud Rate Prescaler value is 7.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PDT</name>
<description>Delay after Transfer Prescaler</description>
<bitOffset>18</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Delay after Transfer Prescaler value is 1.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Delay after Transfer Prescaler value is 3.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Delay after Transfer Prescaler value is 5.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Delay after Transfer Prescaler value is 7.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PASC</name>
<description>After SCK Delay Prescaler</description>
<bitOffset>20</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Delay after Transfer Prescaler value is 1.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Delay after Transfer Prescaler value is 3.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Delay after Transfer Prescaler value is 5.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Delay after Transfer Prescaler value is 7.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PCSSCK</name>
<description>PCS to SCK Delay Prescaler</description>
<bitOffset>22</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>PCS to SCK Prescaler value is 1.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>PCS to SCK Prescaler value is 3.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>PCS to SCK Prescaler value is 5.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>PCS to SCK Prescaler value is 7.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LSBFE</name>
<description>LSB First</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Data is transferred MSB first.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Data is transferred LSB first.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CPHA</name>
<description>Clock Phase</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Data is captured on the leading edge of SCK and changed on the following edge.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Data is changed on the leading edge of SCK and captured on the following edge.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CPOL</name>
<description>Clock Polarity</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The inactive state value of SCK is low.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The inactive state value of SCK is high.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FMSZ</name>
<description>Frame Size</description>
<bitOffset>27</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DBR</name>
<description>Double Baud Rate</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The baud rate is computed normally with a 50/50 duty cycle.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The baud rate is doubled with the duty cycle depending on the Baud Rate Prescaler.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CTAR_SLAVE</name>
<description>Clock and Transfer Attributes Register (In Slave Mode)</description>
<alternateGroup>SPI0</alternateGroup>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x78000000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CPHA</name>
<description>Clock Phase</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Data is captured on the leading edge of SCK and changed on the following edge.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Data is changed on the leading edge of SCK and captured on the following edge.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CPOL</name>
<description>Clock Polarity</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The inactive state value of SCK is low.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The inactive state value of SCK is high.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FMSZ</name>
<description>Frame Size</description>
<bitOffset>27</bitOffset>
<bitWidth>5</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>SR</name>
<description>Status Register</description>
<addressOffset>0x2C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x2000000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>POPNXTPTR</name>
<description>Pop Next Pointer</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
<field>
<name>RXCTR</name>
<description>RX FIFO Counter</description>
<bitOffset>4</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
<field>
<name>TXNXTPTR</name>
<description>Transmit Next Pointer</description>
<bitOffset>8</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
<field>
<name>TXCTR</name>
<description>TX FIFO Counter</description>
<bitOffset>12</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
<field>
<name>RFDF</name>
<description>Receive FIFO Drain Flag</description>
<bitOffset>17</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>RX FIFO is empty.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>RX FIFO is not empty.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RFOF</name>
<description>Receive FIFO Overflow Flag</description>
<bitOffset>19</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No Rx FIFO overflow.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Rx FIFO overflow has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TFFF</name>
<description>Transmit FIFO Fill Flag</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TX FIFO is full.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TX FIFO is not full.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TFUF</name>
<description>Transmit FIFO Underflow Flag</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No TX FIFO underflow.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TX FIFO underflow has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EOQF</name>
<description>End of Queue Flag</description>
<bitOffset>28</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>EOQ is not set in the executing command.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>EOQ is set in the executing SPI command.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXRXS</name>
<description>TX and RX Status</description>
<bitOffset>30</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transmit and receive operations are disabled (The module is in Stopped state).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transmit and receive operations are enabled (The module is in Running state).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TCF</name>
<description>Transfer Complete Flag</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transfer not complete.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transfer complete.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>RSER</name>
<description>DMA/Interrupt Request Select and Enable Register</description>
<addressOffset>0x30</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>RFDF_DIRS</name>
<description>Receive FIFO Drain DMA or Interrupt Request Select</description>
<bitOffset>16</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Interrupt request.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA request.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RFDF_RE</name>
<description>Receive FIFO Drain Request Enable</description>
<bitOffset>17</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>RFDF interrupt or DMA requests are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>RFDF interrupt or DMA requests are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RFOF_RE</name>
<description>Receive FIFO Overflow Request Enable</description>
<bitOffset>19</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>RFOF interrupt requests are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>RFOF interrupt requests are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TFFF_DIRS</name>
<description>Transmit FIFO Fill DMA or Interrupt Request Select</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TFFF flag generates interrupt requests.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TFFF flag generates DMA requests.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TFFF_RE</name>
<description>Transmit FIFO Fill Request Enable</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TFFF interrupts or DMA requests are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TFFF interrupts or DMA requests are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TFUF_RE</name>
<description>Transmit FIFO Underflow Request Enable</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TFUF interrupt requests are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TFUF interrupt requests are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EOQF_RE</name>
<description>Finished Request Enable</description>
<bitOffset>28</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>EOQF interrupt requests are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>EOQF interrupt requests are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TCF_RE</name>
<description>Transmission Complete Request Enable</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TCF interrupt requests are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TCF interrupt requests are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PUSHR</name>
<description>PUSH TX FIFO Register In Master Mode</description>
<alternateGroup>SPI0</alternateGroup>
<addressOffset>0x34</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TXDATA</name>
<description>Transmit Data</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
<field>
<name>PCS</name>
<description>no description available</description>
<bitOffset>16</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Negate the PCS[x] signal</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Assert the PCS[x] signal.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CTCNT</name>
<description>Clear Transfer Counter</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Do not clear the TCR[TCNT] field.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clear the TCR[TCNT] field.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EOQ</name>
<description>End Of Queue</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The SPI data is not the last data to transfer.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The SPI data is the last data to transfer.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CTAS</name>
<description>Clock and Transfer Attributes Select</description>
<bitOffset>28</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>CTAR0</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>CTAR1</description>
<value>#001</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CONT</name>
<description>Continuous Peripheral Chip Select Enable</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Return PCSn signals to their inactive state between transfers.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Keep PCSn signals asserted between transfers.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PUSHR_SLAVE</name>
<description>PUSH TX FIFO Register In Slave Mode</description>
<alternateGroup>SPI0</alternateGroup>
<addressOffset>0x34</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TXDATA</name>
<description>Transmit Data</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>POPR</name>
<description>POP RX FIFO Register</description>
<addressOffset>0x38</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>RXDATA</name>
<description>Received Data</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>TXFR%s</name>
<description>Transmit FIFO Registers</description>
<addressOffset>0x3C</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TXDATA</name>
<description>Transmit Data</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-only</access>
</field>
<field>
<name>TXCMD_TXDATA</name>
<description>Transmit Command or Transmit Data</description>
<bitOffset>16</bitOffset>
<bitWidth>16</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>RXFR%s</name>
<description>Receive FIFO Registers</description>
<addressOffset>0x7C</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>RXDATA</name>
<description>Receive Data</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>SPI1</name>
<description>Serial Peripheral Interface</description>
<groupName>SPI</groupName>
<prependToName>SPI1_</prependToName>
<baseAddress>0x4002D000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x8C</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>SPI1</name>
<value>29</value>
</interrupt>
<registers>
<register>
<name>MCR</name>
<description>Module Configuration Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x4001</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>HALT</name>
<description>Halt</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Start transfers.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Stop transfers.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SMPL_PT</name>
<description>Sample Point</description>
<bitOffset>8</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>0 protocol clock cycles between SCK edge and SIN sample</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>1 protocol clock cycle between SCK edge and SIN sample</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>2 protocol clock cycles between SCK edge and SIN sample</description>
<value>#10</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CLR_RXF</name>
<description>CLR_RXF</description>
<bitOffset>10</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Do not clear the RX FIFO counter.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clear the RX FIFO counter.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CLR_TXF</name>
<description>Clear TX FIFO</description>
<bitOffset>11</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Do not clear the TX FIFO counter.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clear the TX FIFO counter.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DIS_RXF</name>
<description>Disable Receive FIFO</description>
<bitOffset>12</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>RX FIFO is enabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>RX FIFO is disabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DIS_TXF</name>
<description>Disable Transmit FIFO</description>
<bitOffset>13</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TX FIFO is enabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TX FIFO is disabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MDIS</name>
<description>Module Disable</description>
<bitOffset>14</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Enables the module clocks.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Allows external logic to disable the module clocks.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DOZE</name>
<description>Doze Enable</description>
<bitOffset>15</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Doze mode has no effect on the module.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Doze mode disables the module.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PCSIS</name>
<description>Peripheral Chip Select x Inactive State</description>
<bitOffset>16</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The inactive state of PCSx is low.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The inactive state of PCSx is high.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ROOE</name>
<description>Receive FIFO Overflow Overwrite Enable</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Incoming data is ignored.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Incoming data is shifted into the shift register.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MTFE</name>
<description>Modified Timing Format Enable</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Modified SPI transfer format disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Modified SPI transfer format enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FRZ</name>
<description>Freeze</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Do not halt serial transfers in Debug mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Halt serial transfers in Debug mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DCONF</name>
<description>SPI Configuration.</description>
<bitOffset>28</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>SPI</description>
<value>#00</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CONT_SCKE</name>
<description>Continuous SCK Enable</description>
<bitOffset>30</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Continuous SCK disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Continuous SCK enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MSTR</name>
<description>Master/Slave Mode Select</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Enables Slave mode</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enables Master mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>TCR</name>
<description>Transfer Count Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>SPI_TCNT</name>
<description>SPI Transfer Counter</description>
<bitOffset>16</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<dim>2</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1</dimIndex>
<name>CTAR%s</name>
<description>Clock and Transfer Attributes Register (In Master Mode)</description>
<alternateGroup>SPI1</alternateGroup>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x78000000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>BR</name>
<description>Baud Rate Scaler</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DT</name>
<description>Delay After Transfer Scaler</description>
<bitOffset>4</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>ASC</name>
<description>After SCK Delay Scaler</description>
<bitOffset>8</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CSSCK</name>
<description>PCS to SCK Delay Scaler</description>
<bitOffset>12</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>PBR</name>
<description>Baud Rate Prescaler</description>
<bitOffset>16</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Baud Rate Prescaler value is 2.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Baud Rate Prescaler value is 3.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Baud Rate Prescaler value is 5.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Baud Rate Prescaler value is 7.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PDT</name>
<description>Delay after Transfer Prescaler</description>
<bitOffset>18</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Delay after Transfer Prescaler value is 1.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Delay after Transfer Prescaler value is 3.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Delay after Transfer Prescaler value is 5.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Delay after Transfer Prescaler value is 7.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PASC</name>
<description>After SCK Delay Prescaler</description>
<bitOffset>20</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Delay after Transfer Prescaler value is 1.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Delay after Transfer Prescaler value is 3.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Delay after Transfer Prescaler value is 5.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Delay after Transfer Prescaler value is 7.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PCSSCK</name>
<description>PCS to SCK Delay Prescaler</description>
<bitOffset>22</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>PCS to SCK Prescaler value is 1.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>PCS to SCK Prescaler value is 3.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>PCS to SCK Prescaler value is 5.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>PCS to SCK Prescaler value is 7.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LSBFE</name>
<description>LSB First</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Data is transferred MSB first.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Data is transferred LSB first.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CPHA</name>
<description>Clock Phase</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Data is captured on the leading edge of SCK and changed on the following edge.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Data is changed on the leading edge of SCK and captured on the following edge.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CPOL</name>
<description>Clock Polarity</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The inactive state value of SCK is low.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The inactive state value of SCK is high.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FMSZ</name>
<description>Frame Size</description>
<bitOffset>27</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DBR</name>
<description>Double Baud Rate</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The baud rate is computed normally with a 50/50 duty cycle.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The baud rate is doubled with the duty cycle depending on the Baud Rate Prescaler.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CTAR_SLAVE</name>
<description>Clock and Transfer Attributes Register (In Slave Mode)</description>
<alternateGroup>SPI1</alternateGroup>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x78000000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CPHA</name>
<description>Clock Phase</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Data is captured on the leading edge of SCK and changed on the following edge.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Data is changed on the leading edge of SCK and captured on the following edge.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CPOL</name>
<description>Clock Polarity</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The inactive state value of SCK is low.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The inactive state value of SCK is high.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FMSZ</name>
<description>Frame Size</description>
<bitOffset>27</bitOffset>
<bitWidth>5</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>SR</name>
<description>Status Register</description>
<addressOffset>0x2C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x2000000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>POPNXTPTR</name>
<description>Pop Next Pointer</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
<field>
<name>RXCTR</name>
<description>RX FIFO Counter</description>
<bitOffset>4</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
<field>
<name>TXNXTPTR</name>
<description>Transmit Next Pointer</description>
<bitOffset>8</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
<field>
<name>TXCTR</name>
<description>TX FIFO Counter</description>
<bitOffset>12</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
<field>
<name>RFDF</name>
<description>Receive FIFO Drain Flag</description>
<bitOffset>17</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>RX FIFO is empty.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>RX FIFO is not empty.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RFOF</name>
<description>Receive FIFO Overflow Flag</description>
<bitOffset>19</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No Rx FIFO overflow.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Rx FIFO overflow has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TFFF</name>
<description>Transmit FIFO Fill Flag</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TX FIFO is full.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TX FIFO is not full.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TFUF</name>
<description>Transmit FIFO Underflow Flag</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No TX FIFO underflow.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TX FIFO underflow has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EOQF</name>
<description>End of Queue Flag</description>
<bitOffset>28</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>EOQ is not set in the executing command.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>EOQ is set in the executing SPI command.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXRXS</name>
<description>TX and RX Status</description>
<bitOffset>30</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transmit and receive operations are disabled (The module is in Stopped state).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transmit and receive operations are enabled (The module is in Running state).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TCF</name>
<description>Transfer Complete Flag</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transfer not complete.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transfer complete.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>RSER</name>
<description>DMA/Interrupt Request Select and Enable Register</description>
<addressOffset>0x30</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>RFDF_DIRS</name>
<description>Receive FIFO Drain DMA or Interrupt Request Select</description>
<bitOffset>16</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Interrupt request.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA request.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RFDF_RE</name>
<description>Receive FIFO Drain Request Enable</description>
<bitOffset>17</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>RFDF interrupt or DMA requests are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>RFDF interrupt or DMA requests are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RFOF_RE</name>
<description>Receive FIFO Overflow Request Enable</description>
<bitOffset>19</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>RFOF interrupt requests are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>RFOF interrupt requests are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TFFF_DIRS</name>
<description>Transmit FIFO Fill DMA or Interrupt Request Select</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TFFF flag generates interrupt requests.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TFFF flag generates DMA requests.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TFFF_RE</name>
<description>Transmit FIFO Fill Request Enable</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TFFF interrupts or DMA requests are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TFFF interrupts or DMA requests are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TFUF_RE</name>
<description>Transmit FIFO Underflow Request Enable</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TFUF interrupt requests are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TFUF interrupt requests are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EOQF_RE</name>
<description>Finished Request Enable</description>
<bitOffset>28</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>EOQF interrupt requests are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>EOQF interrupt requests are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TCF_RE</name>
<description>Transmission Complete Request Enable</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TCF interrupt requests are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TCF interrupt requests are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PUSHR</name>
<description>PUSH TX FIFO Register In Master Mode</description>
<alternateGroup>SPI1</alternateGroup>
<addressOffset>0x34</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TXDATA</name>
<description>Transmit Data</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
<field>
<name>PCS</name>
<description>no description available</description>
<bitOffset>16</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Negate the PCS[x] signal</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Assert the PCS[x] signal.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CTCNT</name>
<description>Clear Transfer Counter</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Do not clear the TCR[TCNT] field.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clear the TCR[TCNT] field.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EOQ</name>
<description>End Of Queue</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The SPI data is not the last data to transfer.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The SPI data is the last data to transfer.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CTAS</name>
<description>Clock and Transfer Attributes Select</description>
<bitOffset>28</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>CTAR0</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>CTAR1</description>
<value>#001</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CONT</name>
<description>Continuous Peripheral Chip Select Enable</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Return PCSn signals to their inactive state between transfers.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Keep PCSn signals asserted between transfers.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PUSHR_SLAVE</name>
<description>PUSH TX FIFO Register In Slave Mode</description>
<alternateGroup>SPI1</alternateGroup>
<addressOffset>0x34</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TXDATA</name>
<description>Transmit Data</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>POPR</name>
<description>POP RX FIFO Register</description>
<addressOffset>0x38</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>RXDATA</name>
<description>Received Data</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>TXFR%s</name>
<description>Transmit FIFO Registers</description>
<addressOffset>0x3C</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TXDATA</name>
<description>Transmit Data</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-only</access>
</field>
<field>
<name>TXCMD_TXDATA</name>
<description>Transmit Command or Transmit Data</description>
<bitOffset>16</bitOffset>
<bitWidth>16</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>RXFR%s</name>
<description>Receive FIFO Registers</description>
<addressOffset>0x7C</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>RXDATA</name>
<description>Receive Data</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>PIT</name>
<description>Periodic Interrupt Timer</description>
<prependToName>PIT_</prependToName>
<baseAddress>0x40037000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x120</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>PIT0</name>
<value>22</value>
</interrupt>
<registers>
<register>
<name>MCR</name>
<description>PIT Module Control Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x6</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>FRZ</name>
<description>Freeze</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Timers continue to run in Debug mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Timers are stopped in Debug mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MDIS</name>
<description>Module Disable - (PIT section)</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock for standard PIT timers is enabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock for standard PIT timers is disabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>LTMR64H</name>
<description>PIT Upper Lifetime Timer Register</description>
<addressOffset>0xE0</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>LTH</name>
<description>Life Timer value</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>LTMR64L</name>
<description>PIT Lower Lifetime Timer Register</description>
<addressOffset>0xE4</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>LTL</name>
<description>Life Timer value</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>2</dim>
<dimIncrement>0x10</dimIncrement>
<dimIndex>0,1</dimIndex>
<name>LDVAL%s</name>
<description>Timer Load Value Register</description>
<addressOffset>0x100</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TSV</name>
<description>Timer Start Value</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<dim>2</dim>
<dimIncrement>0x10</dimIncrement>
<dimIndex>0,1</dimIndex>
<name>CVAL%s</name>
<description>Current Timer Value Register</description>
<addressOffset>0x104</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TVL</name>
<description>Current Timer Value</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>2</dim>
<dimIncrement>0x10</dimIncrement>
<dimIndex>0,1</dimIndex>
<name>TCTRL%s</name>
<description>Timer Control Register</description>
<addressOffset>0x108</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TEN</name>
<description>Timer Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Timer n is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Timer n is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TIE</name>
<description>Timer Interrupt Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Interrupt requests from Timer n are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Interrupt will be requested whenever TIF is set.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CHN</name>
<description>Chain Mode</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Timer is not chained.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Timer is chained to previous timer. For example, for Channel 2, if this field is set, Timer 2 is chained to Timer 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<dim>2</dim>
<dimIncrement>0x10</dimIncrement>
<dimIndex>0,1</dimIndex>
<name>TFLG%s</name>
<description>Timer Flag Register</description>
<addressOffset>0x10C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TIF</name>
<description>Timer Interrupt Flag</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Timeout has not yet occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Timeout has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>TPM0</name>
<description>Timer/PWM Module</description>
<groupName>TPM</groupName>
<prependToName>TPM0_</prependToName>
<baseAddress>0x40038000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x88</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>TPM0</name>
<value>17</value>
</interrupt>
<registers>
<register>
<name>SC</name>
<description>Status and Control</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PS</name>
<description>Prescale Factor Selection</description>
<bitOffset>0</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Divide by 1</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>Divide by 2</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Divide by 4</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Divide by 8</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Divide by 16</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>Divide by 32</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Divide by 64</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>Divide by 128</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CMOD</name>
<description>Clock Mode Selection</description>
<bitOffset>3</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>TPM counter is disabled</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>TPM counter increments on every TPM counter clock</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>TPM counter increments on rising edge of TPM_EXTCLK synchronized to the TPM counter clock</description>
<value>#10</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CPWMS</name>
<description>Center-Aligned PWM Select</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter operates in up counting mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter operates in up-down counting mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOIE</name>
<description>Timer Overflow Interrupt Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable TOF interrupts. Use software polling or DMA request.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable TOF interrupts. An interrupt is generated when TOF equals one.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOF</name>
<description>Timer Overflow Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter has not overflowed.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter has overflowed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DMA</name>
<description>DMA Enable</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disables DMA transfers.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enables DMA transfers.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CNT</name>
<description>Counter</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>COUNT</name>
<description>Counter value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>MOD</name>
<description>Modulo</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0xFFFF</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>MOD</name>
<description>Modulo value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x8</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>C%sSC</name>
<description>Channel (n) Status and Control</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DMA</name>
<description>DMA Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable DMA transfers.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable DMA transfers.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ELSA</name>
<description>Edge or Level Select</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>ELSB</name>
<description>Edge or Level Select</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>MSA</name>
<description>Channel Mode Select</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>MSB</name>
<description>Channel Mode Select</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CHIE</name>
<description>Channel Interrupt Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable channel interrupts.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable channel interrupts.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CHF</name>
<description>Channel Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x8</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>C%sV</name>
<description>Channel (n) Value</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>VAL</name>
<description>Channel Value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>STATUS</name>
<description>Capture and Compare Status</description>
<addressOffset>0x50</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CH0F</name>
<description>Channel 0 Flag</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CH1F</name>
<description>Channel 1 Flag</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CH2F</name>
<description>Channel 2 Flag</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CH3F</name>
<description>Channel 3 Flag</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOF</name>
<description>Timer Overflow Flag</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter has not overflowed.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter has overflowed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>COMBINE</name>
<description>Combine Channel Register</description>
<addressOffset>0x64</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>COMBINE0</name>
<description>Combine Channels 0 and 1</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Channels 0 and 1 are independent.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Channels 0 and 1 are combined.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COMSWAP0</name>
<description>Combine Channel 0 and 1 Swap</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Even channel is used for input capture and 1st compare.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Odd channel is used for input capture and 1st compare.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COMBINE1</name>
<description>Combine Channels 2 and 3</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Channels 2 and 3 are independent.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Channels 2 and 3 are combined.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COMSWAP1</name>
<description>Combine Channels 2 and 3 Swap</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Even channel is used for input capture and 1st compare.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Odd channel is used for input capture and 1st compare.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FILTER</name>
<description>Filter Control</description>
<addressOffset>0x78</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CH0FVAL</name>
<description>Channel 0 Filter Value</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CH1FVAL</name>
<description>Channel 1 Filter Value</description>
<bitOffset>4</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CH2FVAL</name>
<description>Channel 2 Filter Value</description>
<bitOffset>8</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CH3FVAL</name>
<description>Channel 3 Filter Value</description>
<bitOffset>12</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>QDCTRL</name>
<description>Quadrature Decoder Control and Status</description>
<addressOffset>0x80</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>QUADEN</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Quadrature decoder mode is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Quadrature decoder mode is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOFDIR</name>
<description>no description available</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TOF bit was set on the bottom of counting. There was an FTM counter decrement and FTM counter changes from its minimum value (zero) to its maximum value (MOD register).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TOF bit was set on the top of counting. There was an FTM counter increment and FTM counter changes from its maximum value (MOD register) to its minimum value (zero).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>QUADIR</name>
<description>Counter Direction in Quadrature Decode Mode</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Counter direction is decreasing (counter decrement).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Counter direction is increasing (counter increment).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>QUADMODE</name>
<description>Quadrature Decoder Mode</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Phase encoding mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Count and direction encoding mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CONF</name>
<description>Configuration</description>
<addressOffset>0x84</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DOZEEN</name>
<description>Doze Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal TPM counter continues in Doze mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal TPM counter is paused and does not increment during Doze mode. Trigger inputs and input capture events are also ignored.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DBGMODE</name>
<description>Debug Mode</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>TPM counter is paused and does not increment during debug mode. Trigger inputs and input capture events are also ignored.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>TPM counter continues in debug mode.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>GTBEEN</name>
<description>Global time base enable</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>All channels use the internally generated TPM counter as their timebase</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>All channels use an externally generated global timebase as their timebase</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CSOT</name>
<description>Counter Start on Trigger</description>
<bitOffset>16</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter starts to increment immediately, once it is enabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter only starts to increment when it a rising edge on the selected input trigger is detected, after it has been enabled or after it has stopped due to overflow.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CSOO</name>
<description>Counter Stop On Overflow</description>
<bitOffset>17</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter continues incrementing or decrementing after overflow</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter stops incrementing or decrementing after overflow.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CROT</name>
<description>Counter Reload On Trigger</description>
<bitOffset>18</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Counter is not reloaded due to a rising edge on the selected input trigger</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Counter is reloaded when a rising edge is detected on the selected input trigger</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TRGSEL</name>
<description>Trigger Select</description>
<bitOffset>24</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>TPM1</name>
<description>Timer/PWM Module</description>
<groupName>TPM</groupName>
<prependToName>TPM1_</prependToName>
<baseAddress>0x40039000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x88</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>TPM1</name>
<value>18</value>
</interrupt>
<registers>
<register>
<name>SC</name>
<description>Status and Control</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PS</name>
<description>Prescale Factor Selection</description>
<bitOffset>0</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Divide by 1</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>Divide by 2</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Divide by 4</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Divide by 8</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Divide by 16</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>Divide by 32</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Divide by 64</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>Divide by 128</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CMOD</name>
<description>Clock Mode Selection</description>
<bitOffset>3</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>TPM counter is disabled</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>TPM counter increments on every TPM counter clock</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>TPM counter increments on rising edge of TPM_EXTCLK synchronized to the TPM counter clock</description>
<value>#10</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CPWMS</name>
<description>Center-Aligned PWM Select</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter operates in up counting mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter operates in up-down counting mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOIE</name>
<description>Timer Overflow Interrupt Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable TOF interrupts. Use software polling or DMA request.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable TOF interrupts. An interrupt is generated when TOF equals one.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOF</name>
<description>Timer Overflow Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter has not overflowed.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter has overflowed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DMA</name>
<description>DMA Enable</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disables DMA transfers.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enables DMA transfers.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CNT</name>
<description>Counter</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>COUNT</name>
<description>Counter value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>MOD</name>
<description>Modulo</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0xFFFF</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>MOD</name>
<description>Modulo value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x8</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>C%sSC</name>
<description>Channel (n) Status and Control</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DMA</name>
<description>DMA Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable DMA transfers.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable DMA transfers.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ELSA</name>
<description>Edge or Level Select</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>ELSB</name>
<description>Edge or Level Select</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>MSA</name>
<description>Channel Mode Select</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>MSB</name>
<description>Channel Mode Select</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CHIE</name>
<description>Channel Interrupt Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable channel interrupts.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable channel interrupts.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CHF</name>
<description>Channel Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x8</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>C%sV</name>
<description>Channel (n) Value</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>VAL</name>
<description>Channel Value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>STATUS</name>
<description>Capture and Compare Status</description>
<addressOffset>0x50</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CH0F</name>
<description>Channel 0 Flag</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CH1F</name>
<description>Channel 1 Flag</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CH2F</name>
<description>Channel 2 Flag</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CH3F</name>
<description>Channel 3 Flag</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOF</name>
<description>Timer Overflow Flag</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter has not overflowed.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter has overflowed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>COMBINE</name>
<description>Combine Channel Register</description>
<addressOffset>0x64</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>COMBINE0</name>
<description>Combine Channels 0 and 1</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Channels 0 and 1 are independent.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Channels 0 and 1 are combined.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COMSWAP0</name>
<description>Combine Channel 0 and 1 Swap</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Even channel is used for input capture and 1st compare.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Odd channel is used for input capture and 1st compare.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COMBINE1</name>
<description>Combine Channels 2 and 3</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Channels 2 and 3 are independent.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Channels 2 and 3 are combined.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COMSWAP1</name>
<description>Combine Channels 2 and 3 Swap</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Even channel is used for input capture and 1st compare.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Odd channel is used for input capture and 1st compare.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FILTER</name>
<description>Filter Control</description>
<addressOffset>0x78</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CH0FVAL</name>
<description>Channel 0 Filter Value</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CH1FVAL</name>
<description>Channel 1 Filter Value</description>
<bitOffset>4</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CH2FVAL</name>
<description>Channel 2 Filter Value</description>
<bitOffset>8</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CH3FVAL</name>
<description>Channel 3 Filter Value</description>
<bitOffset>12</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>QDCTRL</name>
<description>Quadrature Decoder Control and Status</description>
<addressOffset>0x80</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>QUADEN</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Quadrature decoder mode is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Quadrature decoder mode is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOFDIR</name>
<description>no description available</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TOF bit was set on the bottom of counting. There was an FTM counter decrement and FTM counter changes from its minimum value (zero) to its maximum value (MOD register).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TOF bit was set on the top of counting. There was an FTM counter increment and FTM counter changes from its maximum value (MOD register) to its minimum value (zero).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>QUADIR</name>
<description>Counter Direction in Quadrature Decode Mode</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Counter direction is decreasing (counter decrement).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Counter direction is increasing (counter increment).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>QUADMODE</name>
<description>Quadrature Decoder Mode</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Phase encoding mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Count and direction encoding mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CONF</name>
<description>Configuration</description>
<addressOffset>0x84</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DOZEEN</name>
<description>Doze Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal TPM counter continues in Doze mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal TPM counter is paused and does not increment during Doze mode. Trigger inputs and input capture events are also ignored.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DBGMODE</name>
<description>Debug Mode</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>TPM counter is paused and does not increment during debug mode. Trigger inputs and input capture events are also ignored.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>TPM counter continues in debug mode.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>GTBEEN</name>
<description>Global time base enable</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>All channels use the internally generated TPM counter as their timebase</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>All channels use an externally generated global timebase as their timebase</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CSOT</name>
<description>Counter Start on Trigger</description>
<bitOffset>16</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter starts to increment immediately, once it is enabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter only starts to increment when it a rising edge on the selected input trigger is detected, after it has been enabled or after it has stopped due to overflow.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CSOO</name>
<description>Counter Stop On Overflow</description>
<bitOffset>17</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter continues incrementing or decrementing after overflow</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter stops incrementing or decrementing after overflow.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CROT</name>
<description>Counter Reload On Trigger</description>
<bitOffset>18</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Counter is not reloaded due to a rising edge on the selected input trigger</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Counter is reloaded when a rising edge is detected on the selected input trigger</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TRGSEL</name>
<description>Trigger Select</description>
<bitOffset>24</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>TPM2</name>
<description>Timer/PWM Module</description>
<groupName>TPM</groupName>
<prependToName>TPM2_</prependToName>
<baseAddress>0x4003A000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x88</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>TPM2</name>
<value>19</value>
</interrupt>
<registers>
<register>
<name>SC</name>
<description>Status and Control</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PS</name>
<description>Prescale Factor Selection</description>
<bitOffset>0</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Divide by 1</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>Divide by 2</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Divide by 4</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Divide by 8</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Divide by 16</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>Divide by 32</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Divide by 64</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>Divide by 128</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CMOD</name>
<description>Clock Mode Selection</description>
<bitOffset>3</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>TPM counter is disabled</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>TPM counter increments on every TPM counter clock</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>TPM counter increments on rising edge of TPM_EXTCLK synchronized to the TPM counter clock</description>
<value>#10</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CPWMS</name>
<description>Center-Aligned PWM Select</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter operates in up counting mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter operates in up-down counting mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOIE</name>
<description>Timer Overflow Interrupt Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable TOF interrupts. Use software polling or DMA request.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable TOF interrupts. An interrupt is generated when TOF equals one.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOF</name>
<description>Timer Overflow Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter has not overflowed.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter has overflowed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DMA</name>
<description>DMA Enable</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disables DMA transfers.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enables DMA transfers.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CNT</name>
<description>Counter</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>COUNT</name>
<description>Counter value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>MOD</name>
<description>Modulo</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0xFFFF</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>MOD</name>
<description>Modulo value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x8</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>C%sSC</name>
<description>Channel (n) Status and Control</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DMA</name>
<description>DMA Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable DMA transfers.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable DMA transfers.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ELSA</name>
<description>Edge or Level Select</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>ELSB</name>
<description>Edge or Level Select</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>MSA</name>
<description>Channel Mode Select</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>MSB</name>
<description>Channel Mode Select</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CHIE</name>
<description>Channel Interrupt Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable channel interrupts.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable channel interrupts.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CHF</name>
<description>Channel Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x8</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>C%sV</name>
<description>Channel (n) Value</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>VAL</name>
<description>Channel Value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>STATUS</name>
<description>Capture and Compare Status</description>
<addressOffset>0x50</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CH0F</name>
<description>Channel 0 Flag</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CH1F</name>
<description>Channel 1 Flag</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CH2F</name>
<description>Channel 2 Flag</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CH3F</name>
<description>Channel 3 Flag</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No channel event has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A channel event has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOF</name>
<description>Timer Overflow Flag</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter has not overflowed.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter has overflowed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>COMBINE</name>
<description>Combine Channel Register</description>
<addressOffset>0x64</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>COMBINE0</name>
<description>Combine Channels 0 and 1</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Channels 0 and 1 are independent.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Channels 0 and 1 are combined.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COMSWAP0</name>
<description>Combine Channel 0 and 1 Swap</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Even channel is used for input capture and 1st compare.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Odd channel is used for input capture and 1st compare.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COMBINE1</name>
<description>Combine Channels 2 and 3</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Channels 2 and 3 are independent.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Channels 2 and 3 are combined.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COMSWAP1</name>
<description>Combine Channels 2 and 3 Swap</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Even channel is used for input capture and 1st compare.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Odd channel is used for input capture and 1st compare.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FILTER</name>
<description>Filter Control</description>
<addressOffset>0x78</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CH0FVAL</name>
<description>Channel 0 Filter Value</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CH1FVAL</name>
<description>Channel 1 Filter Value</description>
<bitOffset>4</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CH2FVAL</name>
<description>Channel 2 Filter Value</description>
<bitOffset>8</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>CH3FVAL</name>
<description>Channel 3 Filter Value</description>
<bitOffset>12</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>QDCTRL</name>
<description>Quadrature Decoder Control and Status</description>
<addressOffset>0x80</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>QUADEN</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Quadrature decoder mode is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Quadrature decoder mode is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOFDIR</name>
<description>no description available</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TOF bit was set on the bottom of counting. There was an FTM counter decrement and FTM counter changes from its minimum value (zero) to its maximum value (MOD register).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TOF bit was set on the top of counting. There was an FTM counter increment and FTM counter changes from its maximum value (MOD register) to its minimum value (zero).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>QUADIR</name>
<description>Counter Direction in Quadrature Decode Mode</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Counter direction is decreasing (counter decrement).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Counter direction is increasing (counter increment).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>QUADMODE</name>
<description>Quadrature Decoder Mode</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Phase encoding mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Count and direction encoding mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CONF</name>
<description>Configuration</description>
<addressOffset>0x84</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DOZEEN</name>
<description>Doze Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal TPM counter continues in Doze mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal TPM counter is paused and does not increment during Doze mode. Trigger inputs and input capture events are also ignored.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DBGMODE</name>
<description>Debug Mode</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>TPM counter is paused and does not increment during debug mode. Trigger inputs and input capture events are also ignored.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>TPM counter continues in debug mode.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>GTBEEN</name>
<description>Global time base enable</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>All channels use the internally generated TPM counter as their timebase</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>All channels use an externally generated global timebase as their timebase</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CSOT</name>
<description>Counter Start on Trigger</description>
<bitOffset>16</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter starts to increment immediately, once it is enabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter only starts to increment when it a rising edge on the selected input trigger is detected, after it has been enabled or after it has stopped due to overflow.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CSOO</name>
<description>Counter Stop On Overflow</description>
<bitOffset>17</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM counter continues incrementing or decrementing after overflow</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM counter stops incrementing or decrementing after overflow.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CROT</name>
<description>Counter Reload On Trigger</description>
<bitOffset>18</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Counter is not reloaded due to a rising edge on the selected input trigger</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Counter is reloaded when a rising edge is detected on the selected input trigger</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TRGSEL</name>
<description>Trigger Select</description>
<bitOffset>24</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>ADC</name>
<description>Analog-to-Digital Converter</description>
<prependToName>ADC_</prependToName>
<baseAddress>0x4003B000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x70</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<dim>2</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>A,B</dimIndex>
<name>SC1%s</name>
<description>ADC Status and Control Registers 1</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x1F</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>ADCH</name>
<description>Input channel select</description>
<bitOffset>0</bitOffset>
<bitWidth>5</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00000</name>
<description>When DIFF=0, DADP0 is selected as input; when DIFF=1, DAD0 is selected as input.</description>
<value>#00000</value>
</enumeratedValue>
<enumeratedValue>
<name>00001</name>
<description>When DIFF=0, DADP1 is selected as input; when DIFF=1, DAD1 is selected as input.</description>
<value>#00001</value>
</enumeratedValue>
<enumeratedValue>
<name>00010</name>
<description>When DIFF=0, DADP2 is selected as input; when DIFF=1, DAD2 is selected as input.</description>
<value>#00010</value>
</enumeratedValue>
<enumeratedValue>
<name>00011</name>
<description>When DIFF=0, DADP3 is selected as input; when DIFF=1, DAD3 is selected as input.</description>
<value>#00011</value>
</enumeratedValue>
<enumeratedValue>
<name>00100</name>
<description>When DIFF=0, AD4 is selected as input; when DIFF=1, it is reserved.</description>
<value>#00100</value>
</enumeratedValue>
<enumeratedValue>
<name>00101</name>
<description>When DIFF=0, AD5 is selected as input; when DIFF=1, it is reserved.</description>
<value>#00101</value>
</enumeratedValue>
<enumeratedValue>
<name>00110</name>
<description>When DIFF=0, AD6 is selected as input; when DIFF=1, it is reserved.</description>
<value>#00110</value>
</enumeratedValue>
<enumeratedValue>
<name>00111</name>
<description>When DIFF=0, AD7 is selected as input; when DIFF=1, it is reserved.</description>
<value>#00111</value>
</enumeratedValue>
<enumeratedValue>
<name>01000</name>
<description>When DIFF=0, AD8 is selected as input; when DIFF=1, it is reserved.</description>
<value>#01000</value>
</enumeratedValue>
<enumeratedValue>
<name>01001</name>
<description>When DIFF=0, AD9 is selected as input; when DIFF=1, it is reserved.</description>
<value>#01001</value>
</enumeratedValue>
<enumeratedValue>
<name>01010</name>
<description>When DIFF=0, AD10 is selected as input; when DIFF=1, it is reserved.</description>
<value>#01010</value>
</enumeratedValue>
<enumeratedValue>
<name>01011</name>
<description>When DIFF=0, AD11 is selected as input; when DIFF=1, it is reserved.</description>
<value>#01011</value>
</enumeratedValue>
<enumeratedValue>
<name>01100</name>
<description>When DIFF=0, AD12 is selected as input; when DIFF=1, it is reserved.</description>
<value>#01100</value>
</enumeratedValue>
<enumeratedValue>
<name>01101</name>
<description>When DIFF=0, AD13 is selected as input; when DIFF=1, it is reserved.</description>
<value>#01101</value>
</enumeratedValue>
<enumeratedValue>
<name>01110</name>
<description>When DIFF=0, AD14 is selected as input; when DIFF=1, it is reserved.</description>
<value>#01110</value>
</enumeratedValue>
<enumeratedValue>
<name>01111</name>
<description>When DIFF=0, AD15 is selected as input; when DIFF=1, it is reserved.</description>
<value>#01111</value>
</enumeratedValue>
<enumeratedValue>
<name>10000</name>
<description>When DIFF=0, AD16 is selected as input; when DIFF=1, it is reserved.</description>
<value>#10000</value>
</enumeratedValue>
<enumeratedValue>
<name>10001</name>
<description>When DIFF=0, AD17 is selected as input; when DIFF=1, it is reserved.</description>
<value>#10001</value>
</enumeratedValue>
<enumeratedValue>
<name>10010</name>
<description>When DIFF=0, AD18 is selected as input; when DIFF=1, it is reserved.</description>
<value>#10010</value>
</enumeratedValue>
<enumeratedValue>
<name>10011</name>
<description>When DIFF=0, AD19 is selected as input; when DIFF=1, it is reserved.</description>
<value>#10011</value>
</enumeratedValue>
<enumeratedValue>
<name>10100</name>
<description>When DIFF=0, AD20 is selected as input; when DIFF=1, it is reserved.</description>
<value>#10100</value>
</enumeratedValue>
<enumeratedValue>
<name>10101</name>
<description>When DIFF=0, AD21 is selected as input; when DIFF=1, it is reserved.</description>
<value>#10101</value>
</enumeratedValue>
<enumeratedValue>
<name>10110</name>
<description>When DIFF=0, AD22 is selected as input; when DIFF=1, it is reserved.</description>
<value>#10110</value>
</enumeratedValue>
<enumeratedValue>
<name>10111</name>
<description>When DIFF=0, AD23 is selected as input; when DIFF=1, it is reserved.</description>
<value>#10111</value>
</enumeratedValue>
<enumeratedValue>
<name>11010</name>
<description>When DIFF=0, Temp Sensor (single-ended) is selected as input; when DIFF=1, Temp Sensor (differential) is selected as input.</description>
<value>#11010</value>
</enumeratedValue>
<enumeratedValue>
<name>11011</name>
<description>When DIFF=0, Bandgap (single-ended) is selected as input; when DIFF=1, Bandgap (differential) is selected as input.</description>
<value>#11011</value>
</enumeratedValue>
<enumeratedValue>
<name>11101</name>
<description>When DIFF=0,VREFSH is selected as input; when DIFF=1, -VREFSH (differential) is selected as input. Voltage reference selected is determined by SC2[REFSEL].</description>
<value>#11101</value>
</enumeratedValue>
<enumeratedValue>
<name>11110</name>
<description>When DIFF=0,VREFSL is selected as input; when DIFF=1, it is reserved. Voltage reference selected is determined by SC2[REFSEL].</description>
<value>#11110</value>
</enumeratedValue>
<enumeratedValue>
<name>11111</name>
<description>Module is disabled.</description>
<value>#11111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DIFF</name>
<description>Differential Mode Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Single-ended conversions and input channels are selected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Differential conversions and input channels are selected.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>AIEN</name>
<description>Interrupt Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Conversion complete interrupt is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Conversion complete interrupt is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COCO</name>
<description>Conversion Complete Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Conversion is not completed.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Conversion is completed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CFG1</name>
<description>ADC Configuration Register 1</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>ADICLK</name>
<description>Input Clock Select</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Bus clock</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Bus clock divided by 2(BUSCLK/DIV2)</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Alternate clock (ALTCLK)</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Asynchronous clock (ADACK)</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MODE</name>
<description>Conversion mode selection</description>
<bitOffset>2</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>When DIFF=0:It is single-ended 8-bit conversion; when DIFF=1, it is differential 9-bit conversion with 2&apos;s complement output.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>When DIFF=0:It is single-ended 12-bit conversion ; when DIFF=1, it is differential 13-bit conversion with 2&apos;s complement output.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>When DIFF=0:It is single-ended 10-bit conversion. ; when DIFF=1, it is differential 11-bit conversion with 2&apos;s complement output</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>When DIFF=0:It is single-ended 16-bit conversion..; when DIFF=1, it is differential 16-bit conversion with 2&apos;s complement output</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADLSMP</name>
<description>Sample Time Configuration</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Short sample time.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Long sample time.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADIV</name>
<description>Clock Divide Select</description>
<bitOffset>5</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>The divide ratio is 1 and the clock rate is input clock.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>The divide ratio is 2 and the clock rate is (input clock)/2.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>The divide ratio is 4 and the clock rate is (input clock)/4.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>The divide ratio is 8 and the clock rate is (input clock)/8.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADLPC</name>
<description>Low-Power Configuration</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal power configuration.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Low-power configuration. The power is reduced at the expense of maximum clock speed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CFG2</name>
<description>ADC Configuration Register 2</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>ADLSTS</name>
<description>Long Sample Time Select</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Default longest sample time; 20 extra ADCK cycles; 24 ADCK cycles total.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>12 extra ADCK cycles; 16 ADCK cycles total sample time.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>6 extra ADCK cycles; 10 ADCK cycles total sample time.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>2 extra ADCK cycles; 6 ADCK cycles total sample time.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADHSC</name>
<description>High-Speed Configuration</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal conversion sequence selected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>High-speed conversion sequence selected with 2 additional ADCK cycles to total conversion time.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADACKEN</name>
<description>Asynchronous Clock Output Enable</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Asynchronous clock output disabled; Asynchronous clock is enabled only if selected by ADICLK and a conversion is active.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Asynchronous clock and clock output is enabled regardless of the state of the ADC.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MUXSEL</name>
<description>ADC Mux Select</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>ADxxa channels are selected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>ADxxb channels are selected.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<dim>2</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>A,B</dimIndex>
<name>R%s</name>
<description>ADC Data Result Register</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>D</name>
<description>Data result</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>2</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>1,2</dimIndex>
<name>CV%s</name>
<description>Compare Value Registers</description>
<addressOffset>0x18</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CV</name>
<description>Compare Value.</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>SC2</name>
<description>Status and Control Register 2</description>
<addressOffset>0x20</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>REFSEL</name>
<description>Voltage Reference Selection</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Default voltage reference pin pair, that is, external pins VREFH and VREFL</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Alternate reference pair, that is, VALTH and VALTL . This pair may be additional external pins or internal sources depending on the MCU configuration. See the chip configuration information for details specific to this MCU</description>
<value>#01</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DMAEN</name>
<description>DMA Enable</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DMA is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA is enabled and will assert the ADC DMA request during an ADC conversion complete event noted when any of the SC1n[COCO] flags is asserted.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ACREN</name>
<description>Compare Function Range Enable</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Range function disabled. Only CV1 is compared.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Range function enabled. Both CV1 and CV2 are compared.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ACFGT</name>
<description>Compare Function Greater Than Enable</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Configures less than threshold, outside range not inclusive and inside range not inclusive; functionality based on the values placed in CV1 and CV2.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Configures greater than or equal to threshold, outside and inside ranges inclusive; functionality based on the values placed in CV1 and CV2.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ACFE</name>
<description>Compare Function Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Compare function disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Compare function enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADTRG</name>
<description>Conversion Trigger Select</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Software trigger selected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware trigger selected.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADACT</name>
<description>Conversion Active</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Conversion not in progress.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Conversion in progress.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SC3</name>
<description>Status and Control Register 3</description>
<addressOffset>0x24</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>AVGS</name>
<description>Hardware Average Select</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>4 samples averaged.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>8 samples averaged.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>16 samples averaged.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>32 samples averaged.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>AVGE</name>
<description>Hardware Average Enable</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Hardware average function disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware average function enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADCO</name>
<description>Continuous Conversion Enable</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>One conversion or one set of conversions if the hardware average function is enabled, that is, AVGE=1, after initiating a conversion.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Continuous conversions or sets of conversions if the hardware average function is enabled, that is, AVGE=1, after initiating a conversion.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CALF</name>
<description>Calibration Failed Flag</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Calibration completed normally.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Calibration failed. ADC accuracy specifications are not guaranteed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CAL</name>
<description>Calibration</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>OFS</name>
<description>ADC Offset Correction Register</description>
<addressOffset>0x28</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x4</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>OFS</name>
<description>Offset Error Correction Value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>PG</name>
<description>ADC Plus-Side Gain Register</description>
<addressOffset>0x2C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x8200</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PG</name>
<description>Plus-Side Gain</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>MG</name>
<description>ADC Minus-Side Gain Register</description>
<addressOffset>0x30</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x8200</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>MG</name>
<description>Minus-Side Gain</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLPD</name>
<description>ADC Plus-Side General Calibration Value Register</description>
<addressOffset>0x34</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0xA</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLPD</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>6</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLPS</name>
<description>ADC Plus-Side General Calibration Value Register</description>
<addressOffset>0x38</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x20</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLPS</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>6</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLP4</name>
<description>ADC Plus-Side General Calibration Value Register</description>
<addressOffset>0x3C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x200</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLP4</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>10</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLP3</name>
<description>ADC Plus-Side General Calibration Value Register</description>
<addressOffset>0x40</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x100</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLP3</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>9</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLP2</name>
<description>ADC Plus-Side General Calibration Value Register</description>
<addressOffset>0x44</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x80</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLP2</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLP1</name>
<description>ADC Plus-Side General Calibration Value Register</description>
<addressOffset>0x48</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x40</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLP1</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>7</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLP0</name>
<description>ADC Plus-Side General Calibration Value Register</description>
<addressOffset>0x4C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x20</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLP0</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>6</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLMD</name>
<description>ADC Minus-Side General Calibration Value Register</description>
<addressOffset>0x54</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0xA</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLMD</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>6</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLMS</name>
<description>ADC Minus-Side General Calibration Value Register</description>
<addressOffset>0x58</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x20</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLMS</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>6</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLM4</name>
<description>ADC Minus-Side General Calibration Value Register</description>
<addressOffset>0x5C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x200</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLM4</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>10</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLM3</name>
<description>ADC Minus-Side General Calibration Value Register</description>
<addressOffset>0x60</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x100</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLM3</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>9</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLM2</name>
<description>ADC Minus-Side General Calibration Value Register</description>
<addressOffset>0x64</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x80</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLM2</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLM1</name>
<description>ADC Minus-Side General Calibration Value Register</description>
<addressOffset>0x68</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x40</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLM1</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>7</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CLM0</name>
<description>ADC Minus-Side General Calibration Value Register</description>
<addressOffset>0x6C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x20</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLM0</name>
<description>Calibration Value</description>
<bitOffset>0</bitOffset>
<bitWidth>6</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>RTC</name>
<description>Secure Real Time Clock</description>
<prependToName>RTC_</prependToName>
<baseAddress>0x4003D000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x20</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>RTC</name>
<value>20</value>
</interrupt>
<interrupt>
<name>RTC_Seconds</name>
<value>21</value>
</interrupt>
<registers>
<register>
<name>TSR</name>
<description>RTC Time Seconds Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TSR</name>
<description>Time Seconds Register</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>TPR</name>
<description>RTC Time Prescaler Register</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TPR</name>
<description>Time Prescaler Register</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>TAR</name>
<description>RTC Time Alarm Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TAR</name>
<description>Time Alarm Register</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>TCR</name>
<description>RTC Time Compensation Register</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TCR</name>
<description>Time Compensation Register</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>10000000</name>
<description>Time Prescaler Register overflows every 32896 clock cycles.</description>
<value>#10000000</value>
</enumeratedValue>
<enumeratedValue>
<name>11111111</name>
<description>Time Prescaler Register overflows every 32769 clock cycles.</description>
<value>#11111111</value>
</enumeratedValue>
<enumeratedValue>
<name>0</name>
<description>Time Prescaler Register overflows every 32768 clock cycles.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Time Prescaler Register overflows every 32767 clock cycles.</description>
<value>#1</value>
</enumeratedValue>
<enumeratedValue>
<name>1111111</name>
<description>Time Prescaler Register overflows every 32641 clock cycles.</description>
<value>#1111111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CIR</name>
<description>Compensation Interval Register</description>
<bitOffset>8</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
<field>
<name>TCV</name>
<description>Time Compensation Value</description>
<bitOffset>16</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
<field>
<name>CIC</name>
<description>Compensation Interval Counter</description>
<bitOffset>24</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>CR</name>
<description>RTC Control Register</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>SWR</name>
<description>Software Reset</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No effect.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Resets all RTC registers except for the SWR bit . The SWR bit is cleared by POR and by software explicitly clearing it.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WPE</name>
<description>Wakeup Pin Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Wakeup pin is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Wakeup pin is enabled and wakeup pin asserts if the RTC interrupt asserts or the wakeup pin is turned on.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SUP</name>
<description>Supervisor Access</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Non-supervisor mode write accesses are not supported and generate a bus error.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Non-supervisor mode write accesses are supported.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>UM</name>
<description>Update Mode</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Registers cannot be written when locked.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Registers can be written when locked under limited conditions.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WPS</name>
<description>Wakeup Pin Select</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Wakeup pin asserts (active low, open drain) if the RTC interrupt asserts or the wakeup pin is turned on.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Wakeup pin instead outputs the RTC 32kHz clock, provided the wakeup pin is turned on and the 32kHz clock is output to other peripherals.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>OSCE</name>
<description>Oscillator Enable</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>32.768 kHz oscillator is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>32.768 kHz oscillator is enabled. After setting this bit, wait the oscillator startup time before enabling the time counter to allow the 32.768 kHz clock time to stabilize.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CLKO</name>
<description>Clock Output</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The 32 kHz clock is output to other peripherals.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The 32 kHz clock is not output to other peripherals.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SC16P</name>
<description>Oscillator 16pF Load Configure</description>
<bitOffset>10</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable the load.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable the additional load.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SC8P</name>
<description>Oscillator 8pF Load Configure</description>
<bitOffset>11</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable the load.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable the additional load.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SC4P</name>
<description>Oscillator 4pF Load Configure</description>
<bitOffset>12</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable the load.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable the additional load.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SC2P</name>
<description>Oscillator 2pF Load Configure</description>
<bitOffset>13</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable the load.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable the additional load.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SR</name>
<description>RTC Status Register</description>
<addressOffset>0x14</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x1</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TIF</name>
<description>Time Invalid Flag</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Time is valid.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Time is invalid and time counter is read as zero.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOF</name>
<description>Time Overflow Flag</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Time overflow has not occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Time overflow has occurred and time counter is read as zero.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TAF</name>
<description>Time Alarm Flag</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Time alarm has not occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Time alarm has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TCE</name>
<description>Time Counter Enable</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Time counter is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Time counter is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>LR</name>
<description>RTC Lock Register</description>
<addressOffset>0x18</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0xFF</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TCL</name>
<description>Time Compensation Lock</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Time Compensation Register is locked and writes are ignored.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Time Compensation Register is not locked and writes complete as normal.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CRL</name>
<description>Control Register Lock</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Control Register is locked and writes are ignored.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Control Register is not locked and writes complete as normal.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SRL</name>
<description>Status Register Lock</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Status Register is locked and writes are ignored.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Status Register is not locked and writes complete as normal.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LRL</name>
<description>Lock Register Lock</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Lock Register is locked and writes are ignored.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Lock Register is not locked and writes complete as normal.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>IER</name>
<description>RTC Interrupt Enable Register</description>
<addressOffset>0x1C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x7</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TIIE</name>
<description>Time Invalid Interrupt Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Time invalid flag does not generate an interrupt.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Time invalid flag does generate an interrupt.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TOIE</name>
<description>Time Overflow Interrupt Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Time overflow flag does not generate an interrupt.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Time overflow flag does generate an interrupt.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TAIE</name>
<description>Time Alarm Interrupt Enable</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Time alarm flag does not generate an interrupt.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Time alarm flag does generate an interrupt.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TSIE</name>
<description>Time Seconds Interrupt Enable</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Seconds interrupt is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Seconds interrupt is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WPON</name>
<description>Wakeup Pin On</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No effect.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>If the wakeup pin is enabled, then the wakeup pin will assert.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>DAC</name>
<description>12-Bit Digital-to-Analog Converter</description>
<prependToName>DAC_</prependToName>
<baseAddress>0x4003F000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x24</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<dim>2</dim>
<dimIncrement>0x2</dimIncrement>
<dimIndex>0,1</dimIndex>
<name>DAT%sL</name>
<description>DAC Data Low Register</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>DATA0</name>
<description>DATA0</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<dim>2</dim>
<dimIncrement>0x2</dimIncrement>
<dimIndex>0,1</dimIndex>
<name>DAT%sH</name>
<description>DAC Data High Register</description>
<addressOffset>0x1</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>DATA1</name>
<description>DATA1</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>SR</name>
<description>DAC Status Register</description>
<addressOffset>0x20</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0x2</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>DACBFRPBF</name>
<description>DAC Buffer Read Pointer Bottom Position Flag</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The DAC buffer read pointer is not equal to C2[DACBFUP].</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DAC buffer read pointer is equal to C2[DACBFUP].</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DACBFRPTF</name>
<description>DAC Buffer Read Pointer Top Position Flag</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The DAC buffer read pointer is not zero.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DAC buffer read pointer is zero.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>C0</name>
<description>DAC Control Register</description>
<addressOffset>0x21</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>DACBBIEN</name>
<description>DAC Buffer Read Pointer Bottom Flag Interrupt Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The DAC buffer read pointer bottom flag interrupt is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DAC buffer read pointer bottom flag interrupt is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DACBTIEN</name>
<description>DAC Buffer Read Pointer Top Flag Interrupt Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The DAC buffer read pointer top flag interrupt is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DAC buffer read pointer top flag interrupt is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LPEN</name>
<description>DAC Low Power Control</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>High-Power mode</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Low-Power mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DACSWTRG</name>
<description>DAC Software Trigger</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The DAC soft trigger is not valid.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DAC soft trigger is valid.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DACTRGSEL</name>
<description>DAC Trigger Select</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The DAC hardware trigger is selected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DAC software trigger is selected.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DACRFS</name>
<description>DAC Reference Select</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The DAC selects DACREF_1 as the reference voltage.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DAC selects DACREF_2 as the reference voltage.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DACEN</name>
<description>DAC Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The DAC system is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The DAC system is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>C1</name>
<description>DAC Control Register 1</description>
<addressOffset>0x22</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>DACBFEN</name>
<description>DAC Buffer Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Buffer read pointer is disabled. The converted data is always the first word of the buffer.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Buffer read pointer is enabled. The converted data is the word that the read pointer points to. It means converted data can be from any word of the buffer.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DACBFMD</name>
<description>DAC Buffer Work Mode Select</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal mode</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>One-Time Scan mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DMAEN</name>
<description>DMA Enable Select</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DMA is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA is enabled. When DMA is enabled, the DMA request will be generated by original interrupts. The interrupts will not be presented on this module at the same time.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>C2</name>
<description>DAC Control Register 2</description>
<addressOffset>0x23</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0x1</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>DACBFUP</name>
<description>DAC Buffer Upper Limit</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DACBFRP</name>
<description>DAC Buffer Read Pointer</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>LPTMR</name>
<description>Low Power Timer</description>
<prependToName>LPTMR_</prependToName>
<baseAddress>0x40040000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x10</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>CSR</name>
<description>Low Power Timer Control Status Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TEN</name>
<description>Timer Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LPTMR is disabled and internal logic is reset.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LPTMR is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TMS</name>
<description>Timer Mode Select</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Time Counter mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pulse Counter mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TFC</name>
<description>Timer Free-Running Counter</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>CNR is reset whenever TCF is set.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>CNR is reset on overflow.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TPP</name>
<description>Timer Pin Polarity</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pulse Counter input source is active-high, and the CNR will increment on the rising-edge.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pulse Counter input source is active-low, and the CNR will increment on the falling-edge.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TPS</name>
<description>Timer Pin Select</description>
<bitOffset>4</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Pulse counter input 0 is selected.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Pulse counter input 1 is selected.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Pulse counter input 2 is selected.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Pulse counter input 3 is selected.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TIE</name>
<description>Timer Interrupt Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Timer interrupt disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Timer interrupt enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TCF</name>
<description>Timer Compare Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The value of CNR is not equal to CMR and increments.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The value of CNR is equal to CMR and increments.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PSR</name>
<description>Low Power Timer Prescale Register</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PCS</name>
<description>Prescaler Clock Select</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Prescaler/glitch filter clock 0 selected.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Prescaler/glitch filter clock 1 selected.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Prescaler/glitch filter clock 2 selected.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Prescaler/glitch filter clock 3 selected.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PBYP</name>
<description>Prescaler Bypass</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Prescaler/glitch filter is enabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Prescaler/glitch filter is bypassed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PRESCALE</name>
<description>Prescale Value</description>
<bitOffset>3</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Prescaler divides the prescaler clock by 2; glitch filter does not support this configuration.</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0001</name>
<description>Prescaler divides the prescaler clock by 4; glitch filter recognizes change on input pin after 2 rising clock edges.</description>
<value>#0001</value>
</enumeratedValue>
<enumeratedValue>
<name>0010</name>
<description>Prescaler divides the prescaler clock by 8; glitch filter recognizes change on input pin after 4 rising clock edges.</description>
<value>#0010</value>
</enumeratedValue>
<enumeratedValue>
<name>0011</name>
<description>Prescaler divides the prescaler clock by 16; glitch filter recognizes change on input pin after 8 rising clock edges.</description>
<value>#0011</value>
</enumeratedValue>
<enumeratedValue>
<name>0100</name>
<description>Prescaler divides the prescaler clock by 32; glitch filter recognizes change on input pin after 16 rising clock edges.</description>
<value>#0100</value>
</enumeratedValue>
<enumeratedValue>
<name>0101</name>
<description>Prescaler divides the prescaler clock by 64; glitch filter recognizes change on input pin after 32 rising clock edges.</description>
<value>#0101</value>
</enumeratedValue>
<enumeratedValue>
<name>0110</name>
<description>Prescaler divides the prescaler clock by 128; glitch filter recognizes change on input pin after 64 rising clock edges.</description>
<value>#0110</value>
</enumeratedValue>
<enumeratedValue>
<name>0111</name>
<description>Prescaler divides the prescaler clock by 256; glitch filter recognizes change on input pin after 128 rising clock edges.</description>
<value>#0111</value>
</enumeratedValue>
<enumeratedValue>
<name>1000</name>
<description>Prescaler divides the prescaler clock by 512; glitch filter recognizes change on input pin after 256 rising clock edges.</description>
<value>#1000</value>
</enumeratedValue>
<enumeratedValue>
<name>1001</name>
<description>Prescaler divides the prescaler clock by 1024; glitch filter recognizes change on input pin after 512 rising clock edges.</description>
<value>#1001</value>
</enumeratedValue>
<enumeratedValue>
<name>1010</name>
<description>Prescaler divides the prescaler clock by 2048; glitch filter recognizes change on input pin after 1024 rising clock edges.</description>
<value>#1010</value>
</enumeratedValue>
<enumeratedValue>
<name>1011</name>
<description>Prescaler divides the prescaler clock by 4096; glitch filter recognizes change on input pin after 2048 rising clock edges.</description>
<value>#1011</value>
</enumeratedValue>
<enumeratedValue>
<name>1100</name>
<description>Prescaler divides the prescaler clock by 8192; glitch filter recognizes change on input pin after 4096 rising clock edges.</description>
<value>#1100</value>
</enumeratedValue>
<enumeratedValue>
<name>1101</name>
<description>Prescaler divides the prescaler clock by 16,384; glitch filter recognizes change on input pin after 8192 rising clock edges.</description>
<value>#1101</value>
</enumeratedValue>
<enumeratedValue>
<name>1110</name>
<description>Prescaler divides the prescaler clock by 32,768; glitch filter recognizes change on input pin after 16,384 rising clock edges.</description>
<value>#1110</value>
</enumeratedValue>
<enumeratedValue>
<name>1111</name>
<description>Prescaler divides the prescaler clock by 65,536; glitch filter recognizes change on input pin after 32,768 rising clock edges.</description>
<value>#1111</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CMR</name>
<description>Low Power Timer Compare Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>COMPARE</name>
<description>Compare Value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CNR</name>
<description>Low Power Timer Counter Register</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>COUNTER</name>
<description>Counter Value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>TSI</name>
<description>Touch sense input</description>
<prependToName>TSI_</prependToName>
<baseAddress>0x40045000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0xC</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>TSI</name>
<value>11</value>
</interrupt>
<registers>
<register>
<name>GENCS</name>
<description>TSI General Control and Status Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CURSW</name>
<description>CURSW</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The current source pair are not swapped.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The current source pair are swapped.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EOSF</name>
<description>End of Scan Flag</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Scan not complete.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Scan complete.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SCNIP</name>
<description>Scan In Progress Status</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No scan in progress.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Scan in progress.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>STM</name>
<description>Scan Trigger Mode</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Software trigger scan.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware trigger scan.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>STPE</name>
<description>TSI STOP Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TSI is disabled when MCU goes into low power mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Allows TSI to continue running in all low power modes.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TSIIEN</name>
<description>Touch Sensing Input Interrupt Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TSI interrupt is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TSI interrupt is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TSIEN</name>
<description>Touch Sensing Input Module Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TSI module disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TSI module enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>NSCN</name>
<description>NSCN</description>
<bitOffset>8</bitOffset>
<bitWidth>5</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00000</name>
<description>Once per electrode</description>
<value>#00000</value>
</enumeratedValue>
<enumeratedValue>
<name>00001</name>
<description>Twice per electrode</description>
<value>#00001</value>
</enumeratedValue>
<enumeratedValue>
<name>00010</name>
<description>3 times per electrode</description>
<value>#00010</value>
</enumeratedValue>
<enumeratedValue>
<name>00011</name>
<description>4 times per electrode</description>
<value>#00011</value>
</enumeratedValue>
<enumeratedValue>
<name>00100</name>
<description>5 times per electrode</description>
<value>#00100</value>
</enumeratedValue>
<enumeratedValue>
<name>00101</name>
<description>6 times per electrode</description>
<value>#00101</value>
</enumeratedValue>
<enumeratedValue>
<name>00110</name>
<description>7 times per electrode</description>
<value>#00110</value>
</enumeratedValue>
<enumeratedValue>
<name>00111</name>
<description>8 times per electrode</description>
<value>#00111</value>
</enumeratedValue>
<enumeratedValue>
<name>01000</name>
<description>9 times per electrode</description>
<value>#01000</value>
</enumeratedValue>
<enumeratedValue>
<name>01001</name>
<description>10 times per electrode</description>
<value>#01001</value>
</enumeratedValue>
<enumeratedValue>
<name>01010</name>
<description>11 times per electrode</description>
<value>#01010</value>
</enumeratedValue>
<enumeratedValue>
<name>01011</name>
<description>12 times per electrode</description>
<value>#01011</value>
</enumeratedValue>
<enumeratedValue>
<name>01100</name>
<description>13 times per electrode</description>
<value>#01100</value>
</enumeratedValue>
<enumeratedValue>
<name>01101</name>
<description>14 times per electrode</description>
<value>#01101</value>
</enumeratedValue>
<enumeratedValue>
<name>01110</name>
<description>15 times per electrode</description>
<value>#01110</value>
</enumeratedValue>
<enumeratedValue>
<name>01111</name>
<description>16 times per electrode</description>
<value>#01111</value>
</enumeratedValue>
<enumeratedValue>
<name>10000</name>
<description>17 times per electrode</description>
<value>#10000</value>
</enumeratedValue>
<enumeratedValue>
<name>10001</name>
<description>18 times per electrode</description>
<value>#10001</value>
</enumeratedValue>
<enumeratedValue>
<name>10010</name>
<description>19 times per electrode</description>
<value>#10010</value>
</enumeratedValue>
<enumeratedValue>
<name>10011</name>
<description>20 times per electrode</description>
<value>#10011</value>
</enumeratedValue>
<enumeratedValue>
<name>10100</name>
<description>21 times per electrode</description>
<value>#10100</value>
</enumeratedValue>
<enumeratedValue>
<name>10101</name>
<description>22 times per electrode</description>
<value>#10101</value>
</enumeratedValue>
<enumeratedValue>
<name>10110</name>
<description>23 times per electrode</description>
<value>#10110</value>
</enumeratedValue>
<enumeratedValue>
<name>10111</name>
<description>24 times per electrode</description>
<value>#10111</value>
</enumeratedValue>
<enumeratedValue>
<name>11000</name>
<description>25 times per electrode</description>
<value>#11000</value>
</enumeratedValue>
<enumeratedValue>
<name>11001</name>
<description>26 times per electrode</description>
<value>#11001</value>
</enumeratedValue>
<enumeratedValue>
<name>11010</name>
<description>27 times per electrode</description>
<value>#11010</value>
</enumeratedValue>
<enumeratedValue>
<name>11011</name>
<description>28 times per electrode</description>
<value>#11011</value>
</enumeratedValue>
<enumeratedValue>
<name>11100</name>
<description>29 times per electrode</description>
<value>#11100</value>
</enumeratedValue>
<enumeratedValue>
<name>11101</name>
<description>30 times per electrode</description>
<value>#11101</value>
</enumeratedValue>
<enumeratedValue>
<name>11110</name>
<description>31 times per electrode</description>
<value>#11110</value>
</enumeratedValue>
<enumeratedValue>
<name>11111</name>
<description>32 times per electrode</description>
<value>#11111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PS</name>
<description>PS</description>
<bitOffset>13</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Electrode Oscillator Frequency divided by 1</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>Electrode Oscillator Frequency divided by 2</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Electrode Oscillator Frequency divided by 4</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Electrode Oscillator Frequency divided by 8</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Electrode Oscillator Frequency divided by 16</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>Electrode Oscillator Frequency divided by 32</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Electrode Oscillator Frequency divided by 64</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>Electrode Oscillator Frequency divided by 128</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EXTCHRG</name>
<description>EXTCHRG</description>
<bitOffset>16</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>500 nA.</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>1 uA.</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>2 uA.</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>4 uA.</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>8 uA.</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>16 uA.</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>32 uA.</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>64 uA.</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DVOLT</name>
<description>DVOLT</description>
<bitOffset>19</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>DV = 1.026 V; VP = 1.328 V; Vm = 0.302 V.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>DV = 0.592 V; VP = 1.111 V; Vm = 0.519 V.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>DV = 0.342 V; VP = 0.986 V; Vm = 0.644 V.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>DV = 0.197 V; VP = 0.914 V; Vm = 0.716 V.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>REFCHRG</name>
<description>REFCHRG</description>
<bitOffset>21</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>500 nA.</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>1 uA.</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>2 uA.</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>4 uA.</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>8 uA.</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>16 uA.</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>32 uA.</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>64 uA.</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MODE</name>
<description>TSI analog modes setup and status bits.</description>
<bitOffset>24</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Set TSI in capacitive sensing(non-noise detection) mode.</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0100</name>
<description>Set TSI analog to work in single threshold noise detection mode and the frequency limitation circuit is disabled.</description>
<value>#0100</value>
</enumeratedValue>
<enumeratedValue>
<name>1000</name>
<description>Set TSI analog to work in single threshold noise detection mode and the frequency limitation circuit is enabled to work in higher frequencies operations.</description>
<value>#1000</value>
</enumeratedValue>
<enumeratedValue>
<name>1100</name>
<description>Set TSI analog to work in automatic noise detection mode.</description>
<value>#1100</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ESOR</name>
<description>End-of-scan or Out-of-Range Interrupt Selection</description>
<bitOffset>28</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Out-of-range interrupt is allowed.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>End-of-scan interrupt is allowed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>OUTRGF</name>
<description>Out of Range Flag.</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>DATA</name>
<description>TSI DATA Register</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TSICNT</name>
<description>TSI Conversion Counter Value</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-only</access>
</field>
<field>
<name>SWTS</name>
<description>Software Trigger Start</description>
<bitOffset>22</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No effect.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Start a scan to determine which channel is specified by TSI_DATA[TSICH].</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DMAEN</name>
<description>DMA Transfer Enabled</description>
<bitOffset>23</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Interrupt is selected when the interrupt enable bit is set and the corresponding TSI events assert.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA transfer request is selected when the interrupt enable bit is set and the corresponding TSI events assert.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TSICH</name>
<description>TSICH</description>
<bitOffset>28</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Channel 0.</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0001</name>
<description>Channel 1.</description>
<value>#0001</value>
</enumeratedValue>
<enumeratedValue>
<name>0010</name>
<description>Channel 2.</description>
<value>#0010</value>
</enumeratedValue>
<enumeratedValue>
<name>0011</name>
<description>Channel 3.</description>
<value>#0011</value>
</enumeratedValue>
<enumeratedValue>
<name>0100</name>
<description>Channel 4.</description>
<value>#0100</value>
</enumeratedValue>
<enumeratedValue>
<name>0101</name>
<description>Channel 5.</description>
<value>#0101</value>
</enumeratedValue>
<enumeratedValue>
<name>0110</name>
<description>Channel 6.</description>
<value>#0110</value>
</enumeratedValue>
<enumeratedValue>
<name>0111</name>
<description>Channel 7.</description>
<value>#0111</value>
</enumeratedValue>
<enumeratedValue>
<name>1000</name>
<description>Channel 8.</description>
<value>#1000</value>
</enumeratedValue>
<enumeratedValue>
<name>1001</name>
<description>Channel 9.</description>
<value>#1001</value>
</enumeratedValue>
<enumeratedValue>
<name>1010</name>
<description>Channel 10.</description>
<value>#1010</value>
</enumeratedValue>
<enumeratedValue>
<name>1011</name>
<description>Channel 11.</description>
<value>#1011</value>
</enumeratedValue>
<enumeratedValue>
<name>1100</name>
<description>Channel 12.</description>
<value>#1100</value>
</enumeratedValue>
<enumeratedValue>
<name>1101</name>
<description>Channel 13.</description>
<value>#1101</value>
</enumeratedValue>
<enumeratedValue>
<name>1110</name>
<description>Channel 14.</description>
<value>#1110</value>
</enumeratedValue>
<enumeratedValue>
<name>1111</name>
<description>Channel 15.</description>
<value>#1111</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>TSHD</name>
<description>TSI Threshold Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>THRESL</name>
<description>TSI Wakeup Channel Low-threshold</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
<field>
<name>THRESH</name>
<description>TSI Wakeup Channel High-threshold</description>
<bitOffset>16</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>SIM</name>
<description>System Integration Module</description>
<prependToName>SIM_</prependToName>
<baseAddress>0x40047000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x1108</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>SOPT1</name>
<description>System Options Register 1</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>OSC32KOUT</name>
<description>32K oscillator clock output</description>
<bitOffset>16</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>ERCLK32K is not output.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>ERCLK32K is output on PTB3.</description>
<value>#01</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>OSC32KSEL</name>
<description>32K Oscillator Clock Select</description>
<bitOffset>18</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>32kHz oscillator (OSC32KCLK)</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>RTC_CLKIN</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>LPO 1kHz</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SOPT2</name>
<description>System Options Register 2</description>
<addressOffset>0x1004</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CLKOUTSEL</name>
<description>CLKOUT select</description>
<bitOffset>5</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>OSCERCLK DIV2</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>OSCERCLK DIV4</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Bus clock</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>LPO clock 1 kHz</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>MCGIRCLK</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>OSCERCLK DIV8</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>OSCERCLK</description>
<value>#110</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TPMSRC</name>
<description>TPM Clock Source Select</description>
<bitOffset>24</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Clock disabled</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>MCGFLLCLK clock</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>OSCERCLK clock</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>MCGIRCLK clock</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LPUART0SRC</name>
<description>LPUART0 Clock Source Select</description>
<bitOffset>26</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Clock disabled</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>MCGFLLCLK clock</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>OSCERCLK clock</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>MCGIRCLK clock</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SOPT4</name>
<description>System Options Register 4</description>
<addressOffset>0x100C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TPM1CH0SRC</name>
<description>TPM1 Channel 0 Input Capture Source Select</description>
<bitOffset>18</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM1_CH0 signal</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>CMP0 output</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TPM2CH0SRC</name>
<description>TPM2 Channel 0 Input Capture Source Select</description>
<bitOffset>20</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM2_CH0 signal</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>CMP0 output</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TPM0CLKSEL</name>
<description>TPM0 External Clock Pin Select</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM0 external clock driven by TPM_CLKIN0 pin.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM0 external clock driven by TPM_CLKIN1 pin.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TPM1CLKSEL</name>
<description>TPM1 External Clock Pin Select</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM1 external clock driven by TPM_CLKIN0 pin.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM1 external clock driven by TPM_CLKIN1 pin.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TPM2CLKSEL</name>
<description>TPM2 External Clock Pin Select</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TPM2 external clock driven by TPM_CLKIN0 pin.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TPM2 external clock driven by TPM_CLKIN1 pin.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SOPT5</name>
<description>System Options Register 5</description>
<addressOffset>0x1010</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>LPUART0TXSRC</name>
<description>LPUART0 Transmit Data Source Select</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>LPUART0_TX pin</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>LPUART0_TX pin modulated with TPM1 channel 0 output</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>LPUART0_TX pin modulated with TPM2 channel 0 output</description>
<value>#10</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LPUART0RXSRC</name>
<description>LPUART0 Receive Data Source Select</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LPUART_RX pin</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>CMP0 output</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LPUART0ODE</name>
<description>LPUART0 Open Drain Enable</description>
<bitOffset>16</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Open drain is disabled on LPUART0.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Open drain is enabled on LPUART0.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SOPT7</name>
<description>System Options Register 7</description>
<addressOffset>0x1018</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>ADC0TRGSEL</name>
<description>ADC0 Trigger Select</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>External trigger pin input (EXTRG_IN)</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0001</name>
<description>CMP0 output</description>
<value>#0001</value>
</enumeratedValue>
<enumeratedValue>
<name>0100</name>
<description>PIT trigger 0</description>
<value>#0100</value>
</enumeratedValue>
<enumeratedValue>
<name>0101</name>
<description>PIT trigger 1</description>
<value>#0101</value>
</enumeratedValue>
<enumeratedValue>
<name>1000</name>
<description>TPM0 overflow</description>
<value>#1000</value>
</enumeratedValue>
<enumeratedValue>
<name>1001</name>
<description>TPM1 overflow</description>
<value>#1001</value>
</enumeratedValue>
<enumeratedValue>
<name>1010</name>
<description>TPM2 overflow</description>
<value>#1010</value>
</enumeratedValue>
<enumeratedValue>
<name>1100</name>
<description>RTC alarm</description>
<value>#1100</value>
</enumeratedValue>
<enumeratedValue>
<name>1101</name>
<description>RTC seconds</description>
<value>#1101</value>
</enumeratedValue>
<enumeratedValue>
<name>1110</name>
<description>LPTMR0 trigger</description>
<value>#1110</value>
</enumeratedValue>
<enumeratedValue>
<name>1111</name>
<description>Radio TSM</description>
<value>#1111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADC0PRETRGSEL</name>
<description>ADC0 Pretrigger Select</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pre-trigger ADHDWTSA is selected, thus ADC0 will use ADC0_SC1A configuration for the next ADC conversion and store the result in ADC0_RA register.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pre-trigger ADHDWTSB is selected, thus ADC0 will use ADC0_SC1B configuration for the next ADC conversion and store the result in ADC0_RB register.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADC0ALTTRGEN</name>
<description>ADC0 Alternate Trigger Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>ADC ADHWT trigger comes from TPM1 channel 0 and channel1. Prior to the assertion of TPM1 channel 0, a pre-trigger pulse will be sent to ADHWTSA to initiate an ADC acquisition using ADCx_SC1A configuration and store ADC conversion in ADCx_RA Register. Prior to the assertion of TPM1 channel 1 a pre-trigger pulse will be sent to ADHWTSB to initiate an ADC acquisition using ADCx_SC1Bconfiguration and store ADC conversion in ADCx_RB Register.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>ADC ADHWT trigger comes from a peripheral event selected by ADC0TRGSEL bits.ADC0PRETRGSEL bit will select the optional ADHWTSA or ADHWTSB select lines for choosing the ADCx_SC1x config and ADCx_Rx result regsiter to store the ADC conversion.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SDID</name>
<description>System Device Identification Register</description>
<addressOffset>0x1024</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0x500000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PINID</name>
<description>Pin count Identification</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0010</name>
<description>32-pin</description>
<value>#0010</value>
</enumeratedValue>
<enumeratedValue>
<name>0100</name>
<description>48-pin</description>
<value>#0100</value>
</enumeratedValue>
<enumeratedValue>
<name>1011</name>
<description>CSP</description>
<value>#1011</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DIEID</name>
<description>Device Die Number</description>
<bitOffset>7</bitOffset>
<bitWidth>5</bitWidth>
<access>read-only</access>
</field>
<field>
<name>REVID</name>
<description>Device Revision Number</description>
<bitOffset>12</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
<field>
<name>SRAMSIZE</name>
<description>System SRAM Size</description>
<bitOffset>16</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
<field>
<name>SERIESID</name>
<description>Kinetis Series ID</description>
<bitOffset>20</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0101</name>
<description>KW family</description>
<value>#0101</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SUBFAMID</name>
<description>Kinetis Sub-Family ID.</description>
<bitOffset>24</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>KWx0 Subfamily</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>KWx1 Subfamily</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>KWx2 Subfamily</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>KWx3 Subfamily</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FAMID</name>
<description>Kinetis family ID</description>
<bitOffset>28</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0010</name>
<description>KW20 Family (802.15.4/ZigBee)</description>
<value>#0010</value>
</enumeratedValue>
<enumeratedValue>
<name>0011</name>
<description>KW30 Family (BTLE)</description>
<value>#0011</value>
</enumeratedValue>
<enumeratedValue>
<name>0100</name>
<description>KW40 Family (802.15.4/ZigBee or BTLE)</description>
<value>#0100</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SCGC4</name>
<description>System Clock Gating Control Register 4</description>
<addressOffset>0x1034</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0xF0000030</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CMT</name>
<description>CMT Clock Gate Control</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>I2C0</name>
<description>I2C0 Clock Gate Control</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>I2C1</name>
<description>I2C1 Clock Gate Control</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CMP</name>
<description>Comparator Clock Gate Control</description>
<bitOffset>19</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SCGC5</name>
<description>System Clock Gating Control Register 5</description>
<addressOffset>0x1038</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x2000182</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>LPTMR</name>
<description>Low Power Timer Access Control</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Access disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Access enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TSI</name>
<description>TSI Access Control</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Access disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Access enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PORTA</name>
<description>Port A Clock Gate Control</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PORTB</name>
<description>Port B Clock Gate Control</description>
<bitOffset>10</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PORTC</name>
<description>Port C Clock Gate Control</description>
<bitOffset>11</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LPUART0</name>
<description>LPUART0 Clock Gate Control</description>
<bitOffset>20</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>AESA</name>
<description>AESA Clock Gate Control</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RSIM</name>
<description>RSIM Clock Gate Control</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
</field>
<field>
<name>DCDC</name>
<description>DCDC Clock Gate Control</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>BTLL</name>
<description>BTLL System Clock Gate Control</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PHYDIG</name>
<description>PHY Digital Clock Gate Control</description>
<bitOffset>28</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ZigBee</name>
<description>ZigBee Clock Gate Control</description>
<bitOffset>29</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SCGC6</name>
<description>System Clock Gating Control Register 6</description>
<addressOffset>0x103C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x1</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>FTF</name>
<description>Flash Memory Clock Gate Control</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DMAMUX</name>
<description>DMA Mux Clock Gate Control</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TRNG</name>
<description>TRNG Clock Gate Control</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SPI0</name>
<description>SPI0 Clock Gate Control</description>
<bitOffset>12</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SPI1</name>
<description>SPI1 Clock Gate Control</description>
<bitOffset>13</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PIT</name>
<description>PIT Clock Gate Control</description>
<bitOffset>23</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TPM0</name>
<description>TPM0 Clock Gate Control</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TPM1</name>
<description>TPM1 Clock Gate Control</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TPM2</name>
<description>TPM2 Clock Gate Control</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADC0</name>
<description>ADC0 Clock Gate Control</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RTC</name>
<description>RTC Access Control</description>
<bitOffset>29</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Access and interrupts disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Access and interrupts enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DAC0</name>
<description>DAC0 Clock Gate Control</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SCGC7</name>
<description>System Clock Gating Control Register 7</description>
<addressOffset>0x1040</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x100</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DMA</name>
<description>DMA Clock Gate Control</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Clock disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Clock enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CLKDIV1</name>
<description>System Clock Divider Register 1</description>
<addressOffset>0x1044</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x10000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>OUTDIV4</name>
<description>Clock 4 Output Divider value</description>
<bitOffset>16</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Divide-by-1.</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>Divide-by-2.</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Divide-by-3.</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Divide-by-4.</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Divide-by-5.</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>Divide-by-6.</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Divide-by-7.</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>Divide-by-8.</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>OUTDIV1</name>
<description>Clock 1 Output Divider value</description>
<bitOffset>28</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Divide-by-1.</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0001</name>
<description>Divide-by-2.</description>
<value>#0001</value>
</enumeratedValue>
<enumeratedValue>
<name>0010</name>
<description>Divide-by-3.</description>
<value>#0010</value>
</enumeratedValue>
<enumeratedValue>
<name>0011</name>
<description>Divide-by-4.</description>
<value>#0011</value>
</enumeratedValue>
<enumeratedValue>
<name>0100</name>
<description>Divide-by-5.</description>
<value>#0100</value>
</enumeratedValue>
<enumeratedValue>
<name>0101</name>
<description>Divide-by-6.</description>
<value>#0101</value>
</enumeratedValue>
<enumeratedValue>
<name>0110</name>
<description>Divide-by-7.</description>
<value>#0110</value>
</enumeratedValue>
<enumeratedValue>
<name>0111</name>
<description>Divide-by-8.</description>
<value>#0111</value>
</enumeratedValue>
<enumeratedValue>
<name>1000</name>
<description>Divide-by-9.</description>
<value>#1000</value>
</enumeratedValue>
<enumeratedValue>
<name>1001</name>
<description>Divide-by-10.</description>
<value>#1001</value>
</enumeratedValue>
<enumeratedValue>
<name>1010</name>
<description>Divide-by-11.</description>
<value>#1010</value>
</enumeratedValue>
<enumeratedValue>
<name>1011</name>
<description>Divide-by-12.</description>
<value>#1011</value>
</enumeratedValue>
<enumeratedValue>
<name>1100</name>
<description>Divide-by-13.</description>
<value>#1100</value>
</enumeratedValue>
<enumeratedValue>
<name>1101</name>
<description>Divide-by-14.</description>
<value>#1101</value>
</enumeratedValue>
<enumeratedValue>
<name>1110</name>
<description>Divide-by-15.</description>
<value>#1110</value>
</enumeratedValue>
<enumeratedValue>
<name>1111</name>
<description>Divide-by-16.</description>
<value>#1111</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FCFG1</name>
<description>Flash Configuration Register 1</description>
<addressOffset>0x104C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>FLASHDIS</name>
<description>Flash Disable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Flash is enabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Flash is disabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FLASHDOZE</name>
<description>Flash Doze</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Flash remains enabled during Doze mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Flash is disabled for the duration of Doze mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PFSIZE</name>
<description>Program Flash Size</description>
<bitOffset>24</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>FCFG2</name>
<description>Flash Configuration Register 2</description>
<addressOffset>0x1050</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0x7FFF0000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>MAXADDR1</name>
<description>no description available</description>
<bitOffset>16</bitOffset>
<bitWidth>7</bitWidth>
<access>read-only</access>
</field>
<field>
<name>MAXADDR0</name>
<description>Max Address lock</description>
<bitOffset>24</bitOffset>
<bitWidth>7</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>UIDMH</name>
<description>Unique Identification Register Mid-High</description>
<addressOffset>0x1058</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>UID</name>
<description>Unique Identification</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>UIDML</name>
<description>Unique Identification Register Mid Low</description>
<addressOffset>0x105C</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>UID</name>
<description>Unique Identification</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>UIDL</name>
<description>Unique Identification Register Low</description>
<addressOffset>0x1060</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>UID</name>
<description>Unique Identification</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>COPC</name>
<description>COP Control Register</description>
<addressOffset>0x1100</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0xC</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>COPW</name>
<description>COP Windowed Mode</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal mode</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Windowed mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COPCLKS</name>
<description>COP Clock Select</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>COP configured for short timeout</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>COP configured for long timeout</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COPT</name>
<description>COP Watchdog Timeout</description>
<bitOffset>2</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>COP disabled</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>COP timeout after 25 cycles for short timeout or 213 cycles for long timeout</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>COP timeout after 28 cycles for short timeout or 216 cycles for long timeout</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>COP timeout after 210 cycles for short timeout or 218 cycles for long timeout</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COPSTPEN</name>
<description>COP Stop Enable</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>COP is disabled and the counter is reset in Stop modes</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>COP is enabled in Stop modes</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COPDBGEN</name>
<description>COP Debug Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>COP is disabled and the counter is reset in Debug mode</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>COP is enabled in Debug mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COPCLKSEL</name>
<description>COP Clock Select</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>LPO clock (1 kHz)</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>MCGIRCLK</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>OSCERCLK</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Bus clock</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SRVCOP</name>
<description>Service COP</description>
<addressOffset>0x1104</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>SRVCOP</name>
<description>Service COP Register</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>write-only</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>PORTA</name>
<description>Pin Control and Interrupts</description>
<groupName>PORT</groupName>
<prependToName>PORTA_</prependToName>
<baseAddress>0x40049000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0xA4</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>PORTA</name>
<value>30</value>
</interrupt>
<registers>
<register>
<dim>32</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31</dimIndex>
<name>PCR%s</name>
<description>Pin Control Register n</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PS</name>
<description>Pull Select</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal pulldown resistor is enabled on the corresponding pin, if the corresponding PE field is set.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal pullup resistor is enabled on the corresponding pin, if the corresponding PE field is set.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PE</name>
<description>Pull Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal pullup or pulldown resistor is not enabled on the corresponding pin.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal pullup or pulldown resistor is enabled on the corresponding pin, if the pin is configured as a digital input.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SRE</name>
<description>Slew Rate Enable</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Fast slew rate is configured on the corresponding pin, if the pin is configured as a digital output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Slow slew rate is configured on the corresponding pin, if the pin is configured as a digital output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PFE</name>
<description>Passive Filter Enable</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Passive input filter is disabled on the corresponding pin.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Passive input filter is enabled on the corresponding pin, if the pin is configured as a digital input. Refer to the device data sheet for filter characteristics.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DSE</name>
<description>Drive Strength Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Low drive strength is configured on the corresponding pin, if pin is configured as a digital output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>High drive strength is configured on the corresponding pin, if pin is configured as a digital output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MUX</name>
<description>Pin Mux Control</description>
<bitOffset>8</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Pin disabled (analog).</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>Alternative 1 (GPIO).</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Alternative 2 (chip-specific).</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Alternative 3 (chip-specific).</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Alternative 4 (chip-specific).</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>Alternative 5 (chip-specific).</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Alternative 6 (chip-specific).</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>Alternative 7 (chip-specific).</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IRQC</name>
<description>Interrupt Configuration</description>
<bitOffset>16</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Interrupt/DMA request disabled.</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0001</name>
<description>DMA request on rising edge.</description>
<value>#0001</value>
</enumeratedValue>
<enumeratedValue>
<name>0010</name>
<description>DMA request on falling edge.</description>
<value>#0010</value>
</enumeratedValue>
<enumeratedValue>
<name>0011</name>
<description>DMA request on either edge.</description>
<value>#0011</value>
</enumeratedValue>
<enumeratedValue>
<name>1000</name>
<description>Interrupt when logic 0.</description>
<value>#1000</value>
</enumeratedValue>
<enumeratedValue>
<name>1001</name>
<description>Interrupt on rising-edge.</description>
<value>#1001</value>
</enumeratedValue>
<enumeratedValue>
<name>1010</name>
<description>Interrupt on falling-edge.</description>
<value>#1010</value>
</enumeratedValue>
<enumeratedValue>
<name>1011</name>
<description>Interrupt on either edge.</description>
<value>#1011</value>
</enumeratedValue>
<enumeratedValue>
<name>1100</name>
<description>Interrupt when logic 1.</description>
<value>#1100</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ISF</name>
<description>Interrupt Status Flag</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Configured interrupt is not detected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Configured interrupt is detected. If the pin is configured to generate a DMA request, then the corresponding flag will be cleared automatically at the completion of the requested DMA transfer. Otherwise, the flag remains set until a logic 1 is written to the flag. If the pin is configured for a level sensitive interrupt and the pin remains asserted, then the flag is set again immediately after it is cleared.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>GPCLR</name>
<description>Global Pin Control Low Register</description>
<addressOffset>0x80</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>GPWD</name>
<description>Global Pin Write Data</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>write-only</access>
</field>
<field>
<name>GPWE</name>
<description>Global Pin Write Enable</description>
<bitOffset>16</bitOffset>
<bitWidth>16</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding Pin Control Register is not updated with the value in GPWD.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding Pin Control Register is updated with the value in GPWD.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>GPCHR</name>
<description>Global Pin Control High Register</description>
<addressOffset>0x84</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>GPWD</name>
<description>Global Pin Write Data</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>write-only</access>
</field>
<field>
<name>GPWE</name>
<description>Global Pin Write Enable</description>
<bitOffset>16</bitOffset>
<bitWidth>16</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding Pin Control Register is not updated with the value in GPWD.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding Pin Control Register is updated with the value in GPWD.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>ISFR</name>
<description>Interrupt Status Flag Register</description>
<addressOffset>0xA0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>ISF</name>
<description>Interrupt Status Flag</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Configured interrupt is not detected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Configured interrupt is detected. If the pin is configured to generate a DMA request, then the corresponding flag will be cleared automatically at the completion of the requested DMA transfer. Otherwise, the flag remains set until a logic 1 is written to the flag. If the pin is configured for a level sensitive interrupt and the pin remains asserted, then the flag is set again immediately after it is cleared.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>PORTB</name>
<description>Pin Control and Interrupts</description>
<groupName>PORT</groupName>
<prependToName>PORTB_</prependToName>
<baseAddress>0x4004A000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0xA4</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>PORTBC</name>
<value>31</value>
</interrupt>
<registers>
<register>
<dim>32</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31</dimIndex>
<name>PCR%s</name>
<description>Pin Control Register n</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PS</name>
<description>Pull Select</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal pulldown resistor is enabled on the corresponding pin, if the corresponding PE field is set.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal pullup resistor is enabled on the corresponding pin, if the corresponding PE field is set.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PE</name>
<description>Pull Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal pullup or pulldown resistor is not enabled on the corresponding pin.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal pullup or pulldown resistor is enabled on the corresponding pin, if the pin is configured as a digital input.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SRE</name>
<description>Slew Rate Enable</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Fast slew rate is configured on the corresponding pin, if the pin is configured as a digital output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Slow slew rate is configured on the corresponding pin, if the pin is configured as a digital output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PFE</name>
<description>Passive Filter Enable</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Passive input filter is disabled on the corresponding pin.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Passive input filter is enabled on the corresponding pin, if the pin is configured as a digital input. Refer to the device data sheet for filter characteristics.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DSE</name>
<description>Drive Strength Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Low drive strength is configured on the corresponding pin, if pin is configured as a digital output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>High drive strength is configured on the corresponding pin, if pin is configured as a digital output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MUX</name>
<description>Pin Mux Control</description>
<bitOffset>8</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Pin disabled (analog).</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>Alternative 1 (GPIO).</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Alternative 2 (chip-specific).</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Alternative 3 (chip-specific).</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Alternative 4 (chip-specific).</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>Alternative 5 (chip-specific).</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Alternative 6 (chip-specific).</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>Alternative 7 (chip-specific).</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IRQC</name>
<description>Interrupt Configuration</description>
<bitOffset>16</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Interrupt/DMA request disabled.</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0001</name>
<description>DMA request on rising edge.</description>
<value>#0001</value>
</enumeratedValue>
<enumeratedValue>
<name>0010</name>
<description>DMA request on falling edge.</description>
<value>#0010</value>
</enumeratedValue>
<enumeratedValue>
<name>0011</name>
<description>DMA request on either edge.</description>
<value>#0011</value>
</enumeratedValue>
<enumeratedValue>
<name>1000</name>
<description>Interrupt when logic 0.</description>
<value>#1000</value>
</enumeratedValue>
<enumeratedValue>
<name>1001</name>
<description>Interrupt on rising-edge.</description>
<value>#1001</value>
</enumeratedValue>
<enumeratedValue>
<name>1010</name>
<description>Interrupt on falling-edge.</description>
<value>#1010</value>
</enumeratedValue>
<enumeratedValue>
<name>1011</name>
<description>Interrupt on either edge.</description>
<value>#1011</value>
</enumeratedValue>
<enumeratedValue>
<name>1100</name>
<description>Interrupt when logic 1.</description>
<value>#1100</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ISF</name>
<description>Interrupt Status Flag</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Configured interrupt is not detected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Configured interrupt is detected. If the pin is configured to generate a DMA request, then the corresponding flag will be cleared automatically at the completion of the requested DMA transfer. Otherwise, the flag remains set until a logic 1 is written to the flag. If the pin is configured for a level sensitive interrupt and the pin remains asserted, then the flag is set again immediately after it is cleared.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>GPCLR</name>
<description>Global Pin Control Low Register</description>
<addressOffset>0x80</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>GPWD</name>
<description>Global Pin Write Data</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>write-only</access>
</field>
<field>
<name>GPWE</name>
<description>Global Pin Write Enable</description>
<bitOffset>16</bitOffset>
<bitWidth>16</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding Pin Control Register is not updated with the value in GPWD.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding Pin Control Register is updated with the value in GPWD.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>GPCHR</name>
<description>Global Pin Control High Register</description>
<addressOffset>0x84</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>GPWD</name>
<description>Global Pin Write Data</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>write-only</access>
</field>
<field>
<name>GPWE</name>
<description>Global Pin Write Enable</description>
<bitOffset>16</bitOffset>
<bitWidth>16</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding Pin Control Register is not updated with the value in GPWD.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding Pin Control Register is updated with the value in GPWD.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>ISFR</name>
<description>Interrupt Status Flag Register</description>
<addressOffset>0xA0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>ISF</name>
<description>Interrupt Status Flag</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Configured interrupt is not detected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Configured interrupt is detected. If the pin is configured to generate a DMA request, then the corresponding flag will be cleared automatically at the completion of the requested DMA transfer. Otherwise, the flag remains set until a logic 1 is written to the flag. If the pin is configured for a level sensitive interrupt and the pin remains asserted, then the flag is set again immediately after it is cleared.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>PORTC</name>
<description>Pin Control and Interrupts</description>
<groupName>PORT</groupName>
<prependToName>PORTC_</prependToName>
<baseAddress>0x4004B000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0xA4</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>PORTBC</name>
<value>31</value>
</interrupt>
<registers>
<register>
<dim>32</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31</dimIndex>
<name>PCR%s</name>
<description>Pin Control Register n</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PS</name>
<description>Pull Select</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal pulldown resistor is enabled on the corresponding pin, if the corresponding PE field is set.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal pullup resistor is enabled on the corresponding pin, if the corresponding PE field is set.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PE</name>
<description>Pull Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal pullup or pulldown resistor is not enabled on the corresponding pin.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal pullup or pulldown resistor is enabled on the corresponding pin, if the pin is configured as a digital input.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SRE</name>
<description>Slew Rate Enable</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Fast slew rate is configured on the corresponding pin, if the pin is configured as a digital output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Slow slew rate is configured on the corresponding pin, if the pin is configured as a digital output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PFE</name>
<description>Passive Filter Enable</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Passive input filter is disabled on the corresponding pin.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Passive input filter is enabled on the corresponding pin, if the pin is configured as a digital input. Refer to the device data sheet for filter characteristics.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DSE</name>
<description>Drive Strength Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Low drive strength is configured on the corresponding pin, if pin is configured as a digital output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>High drive strength is configured on the corresponding pin, if pin is configured as a digital output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MUX</name>
<description>Pin Mux Control</description>
<bitOffset>8</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Pin disabled (analog).</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>Alternative 1 (GPIO).</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Alternative 2 (chip-specific).</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Alternative 3 (chip-specific).</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Alternative 4 (chip-specific).</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>Alternative 5 (chip-specific).</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Alternative 6 (chip-specific).</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>Alternative 7 (chip-specific).</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IRQC</name>
<description>Interrupt Configuration</description>
<bitOffset>16</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Interrupt/DMA request disabled.</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0001</name>
<description>DMA request on rising edge.</description>
<value>#0001</value>
</enumeratedValue>
<enumeratedValue>
<name>0010</name>
<description>DMA request on falling edge.</description>
<value>#0010</value>
</enumeratedValue>
<enumeratedValue>
<name>0011</name>
<description>DMA request on either edge.</description>
<value>#0011</value>
</enumeratedValue>
<enumeratedValue>
<name>1000</name>
<description>Interrupt when logic 0.</description>
<value>#1000</value>
</enumeratedValue>
<enumeratedValue>
<name>1001</name>
<description>Interrupt on rising-edge.</description>
<value>#1001</value>
</enumeratedValue>
<enumeratedValue>
<name>1010</name>
<description>Interrupt on falling-edge.</description>
<value>#1010</value>
</enumeratedValue>
<enumeratedValue>
<name>1011</name>
<description>Interrupt on either edge.</description>
<value>#1011</value>
</enumeratedValue>
<enumeratedValue>
<name>1100</name>
<description>Interrupt when logic 1.</description>
<value>#1100</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ISF</name>
<description>Interrupt Status Flag</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Configured interrupt is not detected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Configured interrupt is detected. If the pin is configured to generate a DMA request, then the corresponding flag will be cleared automatically at the completion of the requested DMA transfer. Otherwise, the flag remains set until a logic 1 is written to the flag. If the pin is configured for a level sensitive interrupt and the pin remains asserted, then the flag is set again immediately after it is cleared.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>GPCLR</name>
<description>Global Pin Control Low Register</description>
<addressOffset>0x80</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>GPWD</name>
<description>Global Pin Write Data</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>write-only</access>
</field>
<field>
<name>GPWE</name>
<description>Global Pin Write Enable</description>
<bitOffset>16</bitOffset>
<bitWidth>16</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding Pin Control Register is not updated with the value in GPWD.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding Pin Control Register is updated with the value in GPWD.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>GPCHR</name>
<description>Global Pin Control High Register</description>
<addressOffset>0x84</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>GPWD</name>
<description>Global Pin Write Data</description>
<bitOffset>0</bitOffset>
<bitWidth>16</bitWidth>
<access>write-only</access>
</field>
<field>
<name>GPWE</name>
<description>Global Pin Write Enable</description>
<bitOffset>16</bitOffset>
<bitWidth>16</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding Pin Control Register is not updated with the value in GPWD.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding Pin Control Register is updated with the value in GPWD.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>ISFR</name>
<description>Interrupt Status Flag Register</description>
<addressOffset>0xA0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>ISF</name>
<description>Interrupt Status Flag</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Configured interrupt is not detected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Configured interrupt is detected. If the pin is configured to generate a DMA request, then the corresponding flag will be cleared automatically at the completion of the requested DMA transfer. Otherwise, the flag remains set until a logic 1 is written to the flag. If the pin is configured for a level sensitive interrupt and the pin remains asserted, then the flag is set again immediately after it is cleared.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>LPUART0</name>
<description>Universal Asynchronous Receiver/Transmitter</description>
<prependToName>LPUART0_</prependToName>
<baseAddress>0x40054000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x20</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>BAUD</name>
<description>LPUART Baud Rate Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0xF000004</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>SBR</name>
<description>Baud Rate Modulo Divisor.</description>
<bitOffset>0</bitOffset>
<bitWidth>13</bitWidth>
<access>read-write</access>
</field>
<field>
<name>SBNS</name>
<description>Stop Bit Number Select</description>
<bitOffset>13</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>One stop bit.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Two stop bits.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RXEDGIE</name>
<description>RX Input Active Edge Interrupt Enable</description>
<bitOffset>14</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Hardware interrupts from LPUART_STAT[RXEDGIF] disabled (use polling).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware interrupt requested when LPUART_STAT[RXEDGIF] flag is 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LBKDIE</name>
<description>LIN Break Detect Interrupt Enable</description>
<bitOffset>15</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Hardware interrupts from LPUART_STAT[LBKDIF] disabled (use polling).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware interrupt requested when LPUART_STAT[LBKDIF] flag is 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RESYNCDIS</name>
<description>Resynchronization Disable</description>
<bitOffset>16</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Resynchronization during received data word is supported</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Resynchronization during received data word is disabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>BOTHEDGE</name>
<description>Both Edge Sampling</description>
<bitOffset>17</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Receiver samples input data using the rising edge of the baud rate clock.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Receiver samples input data using the rising and falling edge of the baud rate clock.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MATCFG</name>
<description>Match Configuration</description>
<bitOffset>18</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Address Match Wakeup</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Idle Match Wakeup</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Match On and Match Off</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Enables RWU on Data Match and Match On/Off for transmitter CTS input</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RDMAE</name>
<description>Receiver Full DMA Enable</description>
<bitOffset>21</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DMA request disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA request enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TDMAE</name>
<description>Transmitter DMA Enable</description>
<bitOffset>23</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DMA request disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA request enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>OSR</name>
<description>Over Sampling Ratio</description>
<bitOffset>24</bitOffset>
<bitWidth>5</bitWidth>
<access>read-write</access>
</field>
<field>
<name>M10</name>
<description>10-bit Mode select</description>
<bitOffset>29</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Receiver and transmitter use 8-bit or 9-bit data characters.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Receiver and transmitter use 10-bit data characters.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MAEN2</name>
<description>Match Address Mode Enable 2</description>
<bitOffset>30</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal operation.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enables automatic address matching or data matching mode for MATCH[MA2].</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MAEN1</name>
<description>Match Address Mode Enable 1</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal operation.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enables automatic address matching or data matching mode for MATCH[MA1].</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>STAT</name>
<description>LPUART Status Register</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0xC00000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>MA2F</name>
<description>Match 2 Flag</description>
<bitOffset>14</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Received data is not equal to MA2</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Received data is equal to MA2</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MA1F</name>
<description>Match 1 Flag</description>
<bitOffset>15</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Received data is not equal to MA1</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Received data is equal to MA1</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PF</name>
<description>Parity Error Flag</description>
<bitOffset>16</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No parity error.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Parity error.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FE</name>
<description>Framing Error Flag</description>
<bitOffset>17</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No framing error detected. This does not guarantee the framing is correct.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Framing error.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>NF</name>
<description>Noise Flag</description>
<bitOffset>18</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No noise detected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Noise detected in the received character in LPUART_DATA.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>OR</name>
<description>Receiver Overrun Flag</description>
<bitOffset>19</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No overrun.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Receive overrun (new LPUART data lost).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IDLE</name>
<description>Idle Line Flag</description>
<bitOffset>20</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No idle line detected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Idle line was detected.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RDRF</name>
<description>Receive Data Register Full Flag</description>
<bitOffset>21</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Receive data buffer empty.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Receive data buffer full.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TC</name>
<description>Transmission Complete Flag</description>
<bitOffset>22</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transmitter active (sending data, a preamble, or a break).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transmitter idle (transmission activity complete).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TDRE</name>
<description>Transmit Data Register Empty Flag</description>
<bitOffset>23</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transmit data buffer full.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transmit data buffer empty.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RAF</name>
<description>Receiver Active Flag</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LPUART receiver idle waiting for a start bit.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LPUART receiver active (LPUART_RX input not idle).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LBKDE</name>
<description>LIN Break Detection Enable</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Break character is detected at length 10 bit times (if M = 0, SBNS = 0) or 11 (if M = 1, SBNS = 0 or M = 0, SBNS = 1) or 12 (if M = 1, SBNS = 1 or M10 = 1, SNBS = 0) or 13 (if M10 = 1, SNBS = 1).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Break character is detected at length of 11 bit times (if M = 0, SBNS = 0) or 12 (if M = 1, SBNS = 0 or M = 0, SBNS = 1) or 14 (if M = 1, SBNS = 1 or M10 = 1, SNBS = 0) or 15 (if M10 = 1, SNBS = 1).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>BRK13</name>
<description>Break Character Generation Length</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Break character is transmitted with length of 10 bit times (if M = 0, SBNS = 0) or 11 (if M = 1, SBNS = 0 or M = 0, SBNS = 1) or 12 (if M = 1, SBNS = 1 or M10 = 1, SNBS = 0) or 13 (if M10 = 1, SNBS = 1).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Break character is transmitted with length of 13 bit times (if M = 0, SBNS = 0) or 14 (if M = 1, SBNS = 0 or M = 0, SBNS = 1) or 15 (if M = 1, SBNS = 1 or M10 = 1, SNBS = 0) or 16 (if M10 = 1, SNBS = 1).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RWUID</name>
<description>Receive Wake Up Idle Detect</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>During receive standby state (RWU = 1), the IDLE bit does not get set upon detection of an idle character. During address match wakeup, the IDLE bit does not get set when an address does not match.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>During receive standby state (RWU = 1), the IDLE bit gets set upon detection of an idle character. During address match wakeup, the IDLE bit does get set when an address does not match.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RXINV</name>
<description>Receive Data Inversion</description>
<bitOffset>28</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Receive data not inverted.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Receive data inverted.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MSBF</name>
<description>MSB First</description>
<bitOffset>29</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LSB (bit0) is the first bit that is transmitted following the start bit. Further, the first bit received after the start bit is identified as bit0.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>MSB (bit9, bit8, bit7 or bit6) is the first bit that is transmitted following the start bit depending on the setting of CTRL[M], CTRL[PE] and BAUD[M10]. Further, the first bit received after the start bit is identified as bit9, bit8, bit7 or bit6 depending on the setting of CTRL[M] and CTRL[PE].</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RXEDGIF</name>
<description>LPUART_RX Pin Active Edge Interrupt Flag</description>
<bitOffset>30</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No active edge on the receive pin has occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>An active edge on the receive pin has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LBKDIF</name>
<description>LIN Break Detect Interrupt Flag</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No LIN break character has been detected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LIN break character has been detected.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CTRL</name>
<description>LPUART Control Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PT</name>
<description>Parity Type</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Even parity.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Odd parity.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PE</name>
<description>Parity Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No hardware parity generation or checking.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Parity enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ILT</name>
<description>Idle Line Type Select</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Idle character bit count starts after start bit.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Idle character bit count starts after stop bit.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WAKE</name>
<description>Receiver Wakeup Method Select</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Configures RWU for idle-line wakeup.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Configures RWU with address-mark wakeup.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>M</name>
<description>9-Bit or 8-Bit Mode Select</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Receiver and transmitter use 8-bit data characters.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Receiver and transmitter use 9-bit data characters.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RSRC</name>
<description>Receiver Source Select</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Provided LOOPS is set, RSRC is cleared, selects internal loop back mode and the LPUART does not use the LPUART_RX pin.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Single-wire LPUART mode where the LPUART_TX pin is connected to the transmitter output and receiver input.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DOZEEN</name>
<description>Doze Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LPUART is enabled in Doze mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LPUART is disabled in Doze mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LOOPS</name>
<description>Loop Mode Select</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal operation - LPUART_RX and LPUART_TX use separate pins.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Loop mode or single-wire mode where transmitter outputs are internally connected to receiver input (see RSRC bit).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IDLECFG</name>
<description>Idle Configuration</description>
<bitOffset>8</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>1 idle character</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>2 idle characters</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>4 idle characters</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>8 idle characters</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>16 idle characters</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>32 idle characters</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>64 idle characters</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>128 idle characters</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MA2IE</name>
<description>Match 2 Interrupt Enable</description>
<bitOffset>14</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>MA2F interrupt disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>MA2F interrupt enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MA1IE</name>
<description>Match 1 Interrupt Enable</description>
<bitOffset>15</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>MA1F interrupt disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>MA1F interrupt enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SBK</name>
<description>Send Break</description>
<bitOffset>16</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal transmitter operation.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Queue break character(s) to be sent.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RWU</name>
<description>Receiver Wakeup Control</description>
<bitOffset>17</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal receiver operation.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LPUART receiver in standby waiting for wakeup condition.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RE</name>
<description>Receiver Enable</description>
<bitOffset>18</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Receiver disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Receiver enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TE</name>
<description>Transmitter Enable</description>
<bitOffset>19</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transmitter disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transmitter enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ILIE</name>
<description>Idle Line Interrupt Enable</description>
<bitOffset>20</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Hardware interrupts from IDLE disabled; use polling.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware interrupt requested when IDLE flag is 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RIE</name>
<description>Receiver Interrupt Enable</description>
<bitOffset>21</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Hardware interrupts from RDRF disabled; use polling.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware interrupt requested when RDRF flag is 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TCIE</name>
<description>Transmission Complete Interrupt Enable for</description>
<bitOffset>22</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Hardware interrupts from TC disabled; use polling.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware interrupt requested when TC flag is 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TIE</name>
<description>Transmit Interrupt Enable</description>
<bitOffset>23</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Hardware interrupts from TDRE disabled; use polling.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware interrupt requested when TDRE flag is 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PEIE</name>
<description>Parity Error Interrupt Enable</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>PF interrupts disabled; use polling).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware interrupt requested when PF is set.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FEIE</name>
<description>Framing Error Interrupt Enable</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>FE interrupts disabled; use polling.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware interrupt requested when FE is set.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>NEIE</name>
<description>Noise Error Interrupt Enable</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>NF interrupts disabled; use polling.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware interrupt requested when NF is set.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ORIE</name>
<description>Overrun Interrupt Enable</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>OR interrupts disabled; use polling.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Hardware interrupt requested when OR is set.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXINV</name>
<description>Transmit Data Inversion</description>
<bitOffset>28</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transmit data not inverted.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transmit data inverted.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXDIR</name>
<description>LPUART_TX Pin Direction in Single-Wire Mode</description>
<bitOffset>29</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LPUART_TX pin is an input in single-wire mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LPUART_TX pin is an output in single-wire mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>R9T8</name>
<description>Receive Bit 9 / Transmit Bit 8</description>
<bitOffset>30</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>R8T9</name>
<description>Receive Bit 8 / Transmit Bit 9</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>DATA</name>
<description>LPUART Data Register</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x1000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>R0T0</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>R1T1</name>
<description>no description available</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>R2T2</name>
<description>no description available</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>R3T3</name>
<description>no description available</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>R4T4</name>
<description>no description available</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>R5T5</name>
<description>no description available</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>R6T6</name>
<description>no description available</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>R7T7</name>
<description>no description available</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>R8T8</name>
<description>no description available</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>R9T9</name>
<description>no description available</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>IDLINE</name>
<description>Idle Line</description>
<bitOffset>11</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Receiver was not idle before receiving this character.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Receiver was idle before receiving this character.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RXEMPT</name>
<description>Receive Buffer Empty</description>
<bitOffset>12</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Receive buffer contains valid data.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Receive buffer is empty, data returned on read is not valid.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FRETSC</name>
<description>Frame Error / Transmit Special Character</description>
<bitOffset>13</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The dataword was received without a frame error on read, transmit a normal character on write.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The dataword was received with a frame error, transmit an idle or break character on transmit.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PARITYE</name>
<description>no description available</description>
<bitOffset>14</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The dataword was received without a parity error.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The dataword was received with a parity error.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>NOISY</name>
<description>no description available</description>
<bitOffset>15</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The dataword was received without noise.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The data was received with noise.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>MATCH</name>
<description>LPUART Match Address Register</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>MA1</name>
<description>Match Address 1</description>
<bitOffset>0</bitOffset>
<bitWidth>10</bitWidth>
<access>read-write</access>
</field>
<field>
<name>MA2</name>
<description>Match Address 2</description>
<bitOffset>16</bitOffset>
<bitWidth>10</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>MODIR</name>
<description>LPUART Modem IrDA Register</description>
<addressOffset>0x14</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TXCTSE</name>
<description>Transmitter clear-to-send enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>CTS has no effect on the transmitter.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enables clear-to-send operation. The transmitter checks the state of CTS each time it is ready to send a character. If CTS is asserted, the character is sent. If CTS is deasserted, the signal TXD remains in the mark state and transmission is delayed until CTS is asserted. Changes in CTS as a character is being sent do not affect its transmission.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXRTSE</name>
<description>Transmitter request-to-send enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The transmitter has no effect on RTS.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>When a character is placed into an empty transmitter data buffer , RTS asserts one bit time before the start bit is transmitted. RTS deasserts one bit time after all characters in the transmitter data buffer and shift register are completely sent, including the last stop bit.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXRTSPOL</name>
<description>Transmitter request-to-send polarity</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transmitter RTS is active low.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transmitter RTS is active high.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RXRTSE</name>
<description>Receiver request-to-send enable</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The receiver has no effect on RTS.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>RTS assertion is configured by the RTSWATER field</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXCTSC</name>
<description>Transmit CTS Configuration</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>CTS input is sampled at the start of each character.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>CTS input is sampled when the transmitter is idle.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXCTSSRC</name>
<description>Transmit CTS Source</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>CTS input is the LPUART_CTS pin.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>CTS input is the inverted Receiver Match result.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RTSWATER</name>
<description>Receive RTS Configuration</description>
<bitOffset>8</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>RTS asserts when the receiver FIFO is full or receiving a character that causes the FIFO to become full.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>RTS asserts when the receive FIFO is less than or equal to the RXWATER configuration and negates when the receive FIFO is greater than the RXWATER configuration.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TNP</name>
<description>Transmitter narrow pulse</description>
<bitOffset>16</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>1/OSR.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>2/OSR.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>3/OSR.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>4/OSR.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IREN</name>
<description>Infrared enable</description>
<bitOffset>18</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>IR disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>IR enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FIFO</name>
<description>LPUART FIFO Register</description>
<addressOffset>0x18</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>RXFIFOSIZE</name>
<description>Receive FIFO. Buffer Depth</description>
<bitOffset>0</bitOffset>
<bitWidth>3</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Receive FIFO/Buffer depth = 1 dataword.</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>Receive FIFO/Buffer depth = 4 datawords.</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Receive FIFO/Buffer depth = 8 datawords.</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Receive FIFO/Buffer depth = 16 datawords.</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Receive FIFO/Buffer depth = 32 datawords.</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>Receive FIFO/Buffer depth = 64 datawords.</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Receive FIFO/Buffer depth = 128 datawords.</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>Receive FIFO/Buffer depth = 256 datawords.</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RXFE</name>
<description>Receive FIFO Enable</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Receive FIFO is not enabled. Buffer is depth 1. (Legacy support)</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Receive FIFO is enabled. Buffer is depth indicted by RXFIFOSIZE.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXFIFOSIZE</name>
<description>Transmit FIFO. Buffer Depth</description>
<bitOffset>4</bitOffset>
<bitWidth>3</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Transmit FIFO/Buffer depth = 1 dataword.</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>Transmit FIFO/Buffer depth = 4 datawords.</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Transmit FIFO/Buffer depth = 8 datawords.</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Transmit FIFO/Buffer depth = 16 datawords.</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Transmit FIFO/Buffer depth = 32 datawords.</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>Transmit FIFO/Buffer depth = 64 datawords.</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Transmit FIFO/Buffer depth = 128 datawords.</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>Transmit FIFO/Buffer depth = 256 datawords</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXFE</name>
<description>Transmit FIFO Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transmit FIFO is not enabled. Buffer is depth 1. (Legacy support).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transmit FIFO is enabled. Buffer is depth indicated by TXFIFOSIZE.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RXUFE</name>
<description>Receive FIFO Underflow Interrupt Enable</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>RXUF flag does not generate an interrupt to the host.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>RXUF flag generates an interrupt to the host.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXOFE</name>
<description>Transmit FIFO Overflow Interrupt Enable</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>TXOF flag does not generate an interrupt to the host.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>TXOF flag generates an interrupt to the host.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RXIDEN</name>
<description>Receiver Idle Empty Enable</description>
<bitOffset>10</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Disable RDRF assertion due to partially filled FIFO when receiver is idle.</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>Enable RDRF assertion due to partially filled FIFO when receiver is idle for 1 character.</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Enable RDRF assertion due to partially filled FIFO when receiver is idle for 2 characters.</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Enable RDRF assertion due to partially filled FIFO when receiver is idle for 4 characters.</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Enable RDRF assertion due to partially filled FIFO when receiver is idle for 8 characters.</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>Enable RDRF assertion due to partially filled FIFO when receiver is idle for 16 characters.</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Enable RDRF assertion due to partially filled FIFO when receiver is idle for 32 characters.</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>Enable RDRF assertion due to partially filled FIFO when receiver is idle for 64 characters.</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RXFLUSH</name>
<description>Receive FIFO/Buffer Flush</description>
<bitOffset>14</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No flush operation occurs.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>All data in the receive FIFO/buffer is cleared out.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXFLUSH</name>
<description>Transmit FIFO/Buffer Flush</description>
<bitOffset>15</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No flush operation occurs.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>All data in the transmit FIFO/Buffer is cleared out.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RXUF</name>
<description>Receiver Buffer Underflow Flag</description>
<bitOffset>16</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No receive buffer underflow has occurred since the last time the flag was cleared.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>At least one receive buffer underflow has occurred since the last time the flag was cleared.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXOF</name>
<description>Transmitter Buffer Overflow Flag</description>
<bitOffset>17</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No transmit buffer overflow has occurred since the last time the flag was cleared.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>At least one transmit buffer overflow has occurred since the last time the flag was cleared.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RXEMPT</name>
<description>Receive Buffer/FIFO Empty</description>
<bitOffset>22</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Receive buffer is not empty.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Receive buffer is empty.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TXEMPT</name>
<description>Transmit Buffer/FIFO Empty</description>
<bitOffset>23</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transmit buffer is not empty.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transmit buffer is empty.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>WATER</name>
<description>LPUART Watermark Register</description>
<addressOffset>0x1C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TXWATER</name>
<description>Transmit Watermark</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
<field>
<name>TXCOUNT</name>
<description>Transmit Counter</description>
<bitOffset>8</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
<field>
<name>RXWATER</name>
<description>Receive Watermark</description>
<bitOffset>16</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
<field>
<name>RXCOUNT</name>
<description>Receive Counter</description>
<bitOffset>24</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>DCDC</name>
<description>DC to DC Converter</description>
<prependToName>DCDC_</prependToName>
<baseAddress>0x4005A000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x20</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>REG0</name>
<description>DCDC REGISTER 0</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x4180000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DCDC_DISABLE_AUTO_CLK_SWITCH</name>
<description>no description available</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_SEL_CLK</name>
<description>no description available</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_PWD_OSC_INT</name>
<description>no description available</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_LP_DF_CMP_ENABLE</name>
<description>no description available</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_VBAT_DIV_CTRL</name>
<description>no description available</description>
<bitOffset>10</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_LP_STATE_HYS_L</name>
<description>no description available</description>
<bitOffset>17</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Target voltage value - 0 mV</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Target voltage value - 25 mV</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Target voltage value - 50 mV</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Target voltage value - 75 mV</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DCDC_LP_STATE_HYS_H</name>
<description>no description available</description>
<bitOffset>19</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Target voltage value + 0 mV</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Target voltage value + 25 mV</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Target voltage value + 50 mV</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Target voltage value + 75 mV</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>HYST_LP_COMP_ADJ</name>
<description>no description available</description>
<bitOffset>21</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>HYST_LP_CMP_DISABLE</name>
<description>no description available</description>
<bitOffset>22</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>OFFSET_RSNS_LP_ADJ</name>
<description>no description available</description>
<bitOffset>23</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>OFFSET_RSNS_LP_DISABLE</name>
<description>no description available</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_LESS_I</name>
<description>no description available</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>PWD_CMP_OFFSET</name>
<description>no description available</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_XTALOK_DISABLE</name>
<description>no description available</description>
<bitOffset>27</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>PSWITCH_STATUS</name>
<description>no description available</description>
<bitOffset>28</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
</field>
<field>
<name>VLPS_CONFIG_DCDC_HP</name>
<description>no description available</description>
<bitOffset>29</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>VLPR_VLPW_CONFIG_DCDC_HP</name>
<description>no description available</description>
<bitOffset>30</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_STS_DC_OK</name>
<description>no description available</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>REG1</name>
<description>DCDC REGISTER 1</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x17C21C</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>POSLIMIT_BUCK_IN</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>7</bitWidth>
<access>read-write</access>
</field>
<field>
<name>POSLIMIT_BOOST_IN</name>
<description>no description available</description>
<bitOffset>7</bitOffset>
<bitWidth>7</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_LOOPCTRL_CM_HST_THRESH</name>
<description>no description available</description>
<bitOffset>21</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_LOOPCTRL_DF_HST_THRESH</name>
<description>no description available</description>
<bitOffset>22</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_LOOPCTRL_EN_CM_HYST</name>
<description>no description available</description>
<bitOffset>23</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_LOOPCTRL_EN_DF_HYST</name>
<description>no description available</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>REG2</name>
<description>DCDC REGISTER 2</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x4009</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DCDC_LOOPCTRL_DC_C</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
</field>
<field>
<name>DCDC_LOOPCTRL_DC_FF</name>
<description>no description available</description>
<bitOffset>6</bitOffset>
<bitWidth>3</bitWidth>
<access>read-only</access>
</field>
<field>
<name>DCDC_LOOPCTRL_HYST_SIGN</name>
<description>no description available</description>
<bitOffset>13</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_LOOPCTRL_TOGGLE_DIF</name>
<description>no description available</description>
<bitOffset>14</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_BATTMONITOR_EN_BATADJ</name>
<description>no description available</description>
<bitOffset>15</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_BATTMONITOR_BATT_VAL</name>
<description>no description available</description>
<bitOffset>16</bitOffset>
<bitWidth>10</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>REG3</name>
<description>DCDC REGISTER 3</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0xA9C6</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DCDC_VDD1P8CTRL_TRG</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>6</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>1.65 V</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>1.8 V</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>10001</name>
<description>2.075 V</description>
<value>#10001</value>
</enumeratedValue>
<enumeratedValue>
<name>100000</name>
<description>2.8 V</description>
<value>#100000</value>
</enumeratedValue>
<enumeratedValue>
<name>110100</name>
<description>3.3 V</description>
<value>#110100</value>
</enumeratedValue>
<enumeratedValue>
<name>111111</name>
<description>3.575 V</description>
<value>#111111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DCDC_VDD1P45CTRL_TRG_BUCK</name>
<description>no description available</description>
<bitOffset>6</bitOffset>
<bitWidth>5</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>1111</name>
<description>1.65 V</description>
<value>#1111</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>1.45 V</description>
<value>#111</value>
</enumeratedValue>
<enumeratedValue>
<name>0</name>
<description>1.275 V</description>
<value>#0</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DCDC_VDD1P45CTRL_TRG_BOOST</name>
<description>no description available</description>
<bitOffset>11</bitOffset>
<bitWidth>5</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>10101</name>
<description>1.8 V</description>
<value>#10101</value>
</enumeratedValue>
<enumeratedValue>
<name>1111</name>
<description>1.65 V</description>
<value>#1111</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>1.45 V</description>
<value>#111</value>
</enumeratedValue>
<enumeratedValue>
<name>0</name>
<description>1.275 V</description>
<value>#0</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DCDC_VDD1P45CTRL_ADJTN</name>
<description>no description available</description>
<bitOffset>17</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_MINPWR_DC_HALFCLK_LIMP</name>
<description>no description available</description>
<bitOffset>21</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_MINPWR_DOUBLE_FETS_LIMP</name>
<description>no description available</description>
<bitOffset>22</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_MINPWR_HALF_FETS_LIMP</name>
<description>no description available</description>
<bitOffset>23</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_MINPWR_DC_HALFCLK</name>
<description>no description available</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_MINPWR_DOUBLE_FETS</name>
<description>no description available</description>
<bitOffset>25</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_MINPWR_HALF_FETS</name>
<description>no description available</description>
<bitOffset>26</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_VDD1P45CTRL_DISABLE_STEP</name>
<description>no description available</description>
<bitOffset>29</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DCDC_VDD1P8CTRL_DISABLE_STEP</name>
<description>no description available</description>
<bitOffset>30</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>REG4</name>
<description>DCDC REGISTER 4</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DCDC_SW_SHUTDOWN</name>
<description>Shut down DCDC</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>UNLOCK</name>
<description>no description available</description>
<bitOffset>16</bitOffset>
<bitWidth>16</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>REG6</name>
<description>DCDC REGISTER 6</description>
<addressOffset>0x18</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PSWITCH_INT_RISE_EN</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>PSWITCH_INT_FALL_EN</name>
<description>no description available</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>PSWITCH_INT_CLEAR</name>
<description>no description available</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>PSWITCH_INT_MUTE</name>
<description>no description available</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>PSWITCH_INT_STS</name>
<description>no description available</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>REG7</name>
<description>DCDC REGISTER 7</description>
<addressOffset>0x1C</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>INTEGRATOR_VALUE</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>19</bitWidth>
<access>read-write</access>
</field>
<field>
<name>INTEGRATOR_VALUE_SEL</name>
<description>no description available</description>
<bitOffset>19</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>PULSE_RUN_SPEEDUP</name>
<description>no description available</description>
<bitOffset>20</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>CMT</name>
<description>Carrier Modulator Transmitter</description>
<prependToName>CMT_</prependToName>
<baseAddress>0x40062000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0xC</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>CGH1</name>
<description>CMT Carrier Generator High Data Register 1</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>PH</name>
<description>Primary Carrier High Time Data Value</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CGL1</name>
<description>CMT Carrier Generator Low Data Register 1</description>
<addressOffset>0x1</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>PL</name>
<description>Primary Carrier Low Time Data Value</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CGH2</name>
<description>CMT Carrier Generator High Data Register 2</description>
<addressOffset>0x2</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>SH</name>
<description>Secondary Carrier High Time Data Value</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CGL2</name>
<description>CMT Carrier Generator Low Data Register 2</description>
<addressOffset>0x3</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>SL</name>
<description>Secondary Carrier Low Time Data Value</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>OC</name>
<description>CMT Output Control Register</description>
<addressOffset>0x4</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>IROPEN</name>
<description>IRO Pin Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The IRO signal is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The IRO signal is enabled as output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CMTPOL</name>
<description>CMT Output Polarity</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The IRO signal is active-low.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The IRO signal is active-high.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IROL</name>
<description>IRO Latch Control</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>MSC</name>
<description>CMT Modulator Status and Control Register</description>
<addressOffset>0x5</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>MCGEN</name>
<description>Modulator and Carrier Generator Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Modulator and carrier generator disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Modulator and carrier generator enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EOCIE</name>
<description>End of Cycle Interrupt Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>CPU interrupt is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>CPU interrupt is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FSK</name>
<description>FSK Mode Select</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The CMT operates in Time or Baseband mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The CMT operates in FSK mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>BASE</name>
<description>Baseband Enable</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Baseband mode is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Baseband mode is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EXSPC</name>
<description>Extended Space Enable</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Extended space is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Extended space is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CMTDIV</name>
<description>CMT Clock Divide Prescaler</description>
<bitOffset>5</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>IF * 1</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>IF * 2</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>IF * 4</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>IF * 8</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EOCF</name>
<description>End Of Cycle Status Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>End of modulation cycle has not occured since the flag last cleared.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>End of modulator cycle has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CMD1</name>
<description>CMT Modulator Data Register Mark High</description>
<addressOffset>0x6</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>MB</name>
<description>MB[15:8]</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CMD2</name>
<description>CMT Modulator Data Register Mark Low</description>
<addressOffset>0x7</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>MB</name>
<description>MB[7:0]</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CMD3</name>
<description>CMT Modulator Data Register Space High</description>
<addressOffset>0x8</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>SB</name>
<description>SB[15:8]</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>CMD4</name>
<description>CMT Modulator Data Register Space Low</description>
<addressOffset>0x9</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>SB</name>
<description>SB[7:0]</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>PPS</name>
<description>CMT Primary Prescaler Register</description>
<addressOffset>0xA</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>PPSDIV</name>
<description>Primary Prescaler Divider</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Bus clock * 1</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0001</name>
<description>Bus clock * 2</description>
<value>#0001</value>
</enumeratedValue>
<enumeratedValue>
<name>0010</name>
<description>Bus clock * 3</description>
<value>#0010</value>
</enumeratedValue>
<enumeratedValue>
<name>0011</name>
<description>Bus clock * 4</description>
<value>#0011</value>
</enumeratedValue>
<enumeratedValue>
<name>0100</name>
<description>Bus clock * 5</description>
<value>#0100</value>
</enumeratedValue>
<enumeratedValue>
<name>0101</name>
<description>Bus clock * 6</description>
<value>#0101</value>
</enumeratedValue>
<enumeratedValue>
<name>0110</name>
<description>Bus clock * 7</description>
<value>#0110</value>
</enumeratedValue>
<enumeratedValue>
<name>0111</name>
<description>Bus clock * 8</description>
<value>#0111</value>
</enumeratedValue>
<enumeratedValue>
<name>1000</name>
<description>Bus clock * 9</description>
<value>#1000</value>
</enumeratedValue>
<enumeratedValue>
<name>1001</name>
<description>Bus clock * 10</description>
<value>#1001</value>
</enumeratedValue>
<enumeratedValue>
<name>1010</name>
<description>Bus clock * 11</description>
<value>#1010</value>
</enumeratedValue>
<enumeratedValue>
<name>1011</name>
<description>Bus clock * 12</description>
<value>#1011</value>
</enumeratedValue>
<enumeratedValue>
<name>1100</name>
<description>Bus clock * 13</description>
<value>#1100</value>
</enumeratedValue>
<enumeratedValue>
<name>1101</name>
<description>Bus clock * 14</description>
<value>#1101</value>
</enumeratedValue>
<enumeratedValue>
<name>1110</name>
<description>Bus clock * 15</description>
<value>#1110</value>
</enumeratedValue>
<enumeratedValue>
<name>1111</name>
<description>Bus clock * 16</description>
<value>#1111</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>DMA</name>
<description>CMT Direct Memory Access Register</description>
<addressOffset>0xB</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>DMA</name>
<description>DMA Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DMA transfer request and done are disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA transfer request and done are enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>MCG</name>
<description>Multipurpose Clock Generator module</description>
<prependToName>MCG_</prependToName>
<baseAddress>0x40064000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0xE</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>MCG</name>
<value>27</value>
</interrupt>
<registers>
<register>
<name>C1</name>
<description>MCG Control 1 Register</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0x4</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>IREFSTEN</name>
<description>Internal Reference Stop Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal reference clock is disabled in Stop mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal reference clock is enabled in Stop mode if IRCLKEN is set or if MCG is in FEI, FBI, or BLPI modes before entering Stop mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IRCLKEN</name>
<description>Internal Reference Clock Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>MCGIRCLK inactive.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>MCGIRCLK active.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IREFS</name>
<description>Internal Reference Select</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>External reference clock is selected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The slow internal reference clock is selected.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FRDIV</name>
<description>FLL External Reference Divider</description>
<bitOffset>3</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>If RANGE = 0 or OSCSEL=1 , Divide Factor is 1; for all other RANGE values, Divide Factor is 32.</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>If RANGE = 0 or OSCSEL=1 , Divide Factor is 2; for all other RANGE values, Divide Factor is 64.</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>If RANGE = 0 or OSCSEL=1 , Divide Factor is 4; for all other RANGE values, Divide Factor is 128.</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>If RANGE = 0 or OSCSEL=1 , Divide Factor is 8; for all other RANGE values, Divide Factor is 256.</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>If RANGE = 0 or OSCSEL=1 , Divide Factor is 16; for all other RANGE values, Divide Factor is 512.</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>If RANGE = 0 or OSCSEL=1 , Divide Factor is 32; for all other RANGE values, Divide Factor is 1024.</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>If RANGE = 0 or OSCSEL=1 , Divide Factor is 64; for all other RANGE values, Divide Factor is 1280 .</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>If RANGE = 0 or OSCSEL=1 , Divide Factor is 128; for all other RANGE values, Divide Factor is 1536 .</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CLKS</name>
<description>Clock Source Select</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Encoding 0 - Output of FLL is selected.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Encoding 1 - Internal reference clock is selected.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Encoding 2 - External reference clock is selected.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Encoding 3 - Reserved.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>C2</name>
<description>MCG Control 2 Register</description>
<addressOffset>0x1</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0xC0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>IRCS</name>
<description>Internal Reference Clock Select</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Slow internal reference clock selected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Fast internal reference clock selected.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LP</name>
<description>Low Power Select</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>FLL is not disabled in bypass modes.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>FLL is disabled in bypass modes (lower power)</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EREFS</name>
<description>External Reference Select</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>External reference clock requested.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Oscillator requested.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>HGO</name>
<description>High Gain Oscillator Select</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Configure crystal oscillator for low-power operation.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Configure crystal oscillator for high-gain operation.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RANGE</name>
<description>Frequency Range Select</description>
<bitOffset>4</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Encoding 0 - Low frequency range selected for the crystal oscillator .</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Encoding 1 - High frequency range selected for the crystal oscillator .</description>
<value>#01</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FCFTRIM</name>
<description>Fast Internal Reference Clock Fine Trim</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>LOCRE0</name>
<description>Loss of Clock Reset Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Interrupt request is generated on a loss of OSC0 external reference clock.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Generate a reset request on a loss of OSC0 external reference clock.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>C3</name>
<description>MCG Control 3 Register</description>
<addressOffset>0x2</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>SCTRIM</name>
<description>Slow Internal Reference Clock Trim Setting</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>C4</name>
<description>MCG Control 4 Register</description>
<addressOffset>0x3</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xE0</resetMask>
<fields>
<field>
<name>SCFTRIM</name>
<description>Slow Internal Reference Clock Fine Trim</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>FCTRIM</name>
<description>Fast Internal Reference Clock Trim Setting</description>
<bitOffset>1</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>DRST_DRS</name>
<description>DCO Range Select</description>
<bitOffset>5</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Encoding 0 - Low range (reset default).</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Encoding 1 - Mid range.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Encoding 2 - Mid-high range.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Encoding 3 - High range.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DMX32</name>
<description>DCO Maximum Frequency with 32.768 kHz Reference</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DCO has a default range of 25%.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DCO is fine-tuned for maximum frequency with 32.768 kHz reference.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>C5</name>
<description>MCG Control 5 Register</description>
<addressOffset>0x4</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
</register>
<register>
<name>C6</name>
<description>MCG Control 6 Register</description>
<addressOffset>0x5</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>CME</name>
<description>Clock Monitor Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>External clock monitor is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Generate a reset request on loss of external clock.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>S</name>
<description>MCG Status Register</description>
<addressOffset>0x6</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0x10</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>IRCST</name>
<description>Internal Reference Clock Status</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Source of internal reference clock is the slow clock (32 kHz IRC).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Source of internal reference clock is the fast clock (4 MHz IRC).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>OSCINIT0</name>
<description>OSC Initialization</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
</field>
<field>
<name>CLKST</name>
<description>Clock Mode Status</description>
<bitOffset>2</bitOffset>
<bitWidth>2</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Encoding 0 - Output of the FLL is selected (reset default).</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Encoding 1 - Internal reference clock is selected.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Encoding 2 - External reference clock is selected.</description>
<value>#10</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IREFST</name>
<description>Internal Reference Status</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Source of FLL reference clock is the external reference clock.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Source of FLL reference clock is the internal reference clock.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SC</name>
<description>MCG Status and Control Register</description>
<addressOffset>0x8</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0x2</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>LOCS0</name>
<description>OSC0 Loss of Clock Status</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Loss of OSC0 has not occurred.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Loss of OSC0 has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FCRDIV</name>
<description>Fast Clock Internal Reference Divider</description>
<bitOffset>1</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Divide Factor is 1</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>Divide Factor is 2.</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Divide Factor is 4.</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Divide Factor is 8.</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Divide Factor is 16</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>Divide Factor is 32</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Divide Factor is 64</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>Divide Factor is 128.</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FLTPRSRV</name>
<description>FLL Filter Preserve Enable</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>FLL filter and FLL frequency will reset on changes to currect clock mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Fll filter and FLL frequency retain their previous values during new clock mode change.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ATMF</name>
<description>Automatic Trim Machine Fail Flag</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Automatic Trim Machine completed normally.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Automatic Trim Machine failed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ATMS</name>
<description>Automatic Trim Machine Select</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>32 kHz Internal Reference Clock selected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>4 MHz Internal Reference Clock selected.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ATME</name>
<description>Automatic Trim Machine Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Auto Trim Machine disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Auto Trim Machine enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>ATCVH</name>
<description>MCG Auto Trim Compare Value High Register</description>
<addressOffset>0xA</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>ATCVH</name>
<description>ATM Compare Value High</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>ATCVL</name>
<description>MCG Auto Trim Compare Value Low Register</description>
<addressOffset>0xB</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>ATCVL</name>
<description>ATM Compare Value Low</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>C7</name>
<description>MCG Control 7 Register</description>
<addressOffset>0xC</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>OSCSEL</name>
<description>MCG OSC Clock Select</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Selects Oscillator (OSCCLK).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Selects 32 kHz RTC Oscillator.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>C8</name>
<description>MCG Control 8 Register</description>
<addressOffset>0xD</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0x80</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>LOCS1</name>
<description>RTC Loss of Clock Status</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Loss of RTC has not occur.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Loss of RTC has occur</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CME1</name>
<description>Clock Monitor Enable1</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>External clock monitor is disabled for RTC clock.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>External clock monitor is enabled for RTC clock.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LOCRE1</name>
<description>Loss of Clock Reset Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Interrupt request is generated on a loss of RTC external reference clock.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Generate a reset request on a loss of RTC external reference clock</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>I2C0</name>
<description>Inter-Integrated Circuit</description>
<groupName>I2C</groupName>
<prependToName>I2C0_</prependToName>
<baseAddress>0x40066000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0xD</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>I2C0</name>
<value>8</value>
</interrupt>
<registers>
<register>
<name>A1</name>
<description>I2C Address Register 1</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>AD</name>
<description>Address</description>
<bitOffset>1</bitOffset>
<bitWidth>7</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>F</name>
<description>I2C Frequency Divider register</description>
<addressOffset>0x1</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>ICR</name>
<description>ClockRate</description>
<bitOffset>0</bitOffset>
<bitWidth>6</bitWidth>
<access>read-write</access>
</field>
<field>
<name>MULT</name>
<description>Multiplier Factor</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>mul = 1</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>mul = 2</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>mul = 4</description>
<value>#10</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>C1</name>
<description>I2C Control Register 1</description>
<addressOffset>0x2</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>DMAEN</name>
<description>DMA Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>All DMA signalling disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA transfer is enabled. While SMB[FACK] = 0, the following conditions trigger the DMA request: a data byte is received, and either address or data is transmitted. (ACK/NACK is automatic) the first byte received matches the A1 register or is a general call address. If any address matching occurs, S[IAAS] and S[TCF] are set. If the direction of transfer is known from master to slave, then it is not required to check S[SRW]. With this assumption, DMA can also be used in this case. In other cases, if the master reads data from the slave, then it is required to rewrite the C1 register operation. With this assumption, DMA cannot be used. When FACK = 1, an address or a data byte is transmitted.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUEN</name>
<description>Wakeup Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal operation. No interrupt generated when address matching in low power mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enables the wakeup function in low power mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RSTA</name>
<description>Repeat START</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
</field>
<field>
<name>TXAK</name>
<description>Transmit Acknowledge Enable</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>An acknowledge signal is sent to the bus on the following receiving byte (if FACK is cleared) or the current receiving byte (if FACK is set).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>No acknowledge signal is sent to the bus on the following receiving data byte (if FACK is cleared) or the current receiving data byte (if FACK is set).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TX</name>
<description>Transmit Mode Select</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Receive</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transmit</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MST</name>
<description>Master Mode Select</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Slave mode</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Master mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IICIE</name>
<description>I2C Interrupt Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IICEN</name>
<description>I2C Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>S</name>
<description>I2C Status register</description>
<addressOffset>0x3</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0x80</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>RXAK</name>
<description>Receive Acknowledge</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Acknowledge signal was received after the completion of one byte of data transmission on the bus</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>No acknowledge signal detected</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IICIF</name>
<description>Interrupt Flag</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No interrupt pending</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Interrupt pending</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SRW</name>
<description>Slave Read/Write</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Slave receive, master writing to slave</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Slave transmit, master reading from slave</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RAM</name>
<description>Range Address Match</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Not addressed</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Addressed as a slave</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ARBL</name>
<description>Arbitration Lost</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Standard bus operation.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Loss of arbitration.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>BUSY</name>
<description>Bus Busy</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Bus is idle</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Bus is busy</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IAAS</name>
<description>Addressed As A Slave</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Not addressed</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Addressed as a slave</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TCF</name>
<description>Transfer Complete Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transfer in progress</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transfer complete</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>D</name>
<description>I2C Data I/O register</description>
<addressOffset>0x4</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>DATA</name>
<description>Data</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>C2</name>
<description>I2C Control Register 2</description>
<addressOffset>0x5</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>AD</name>
<description>Slave Address</description>
<bitOffset>0</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
</field>
<field>
<name>RMEN</name>
<description>Range Address Matching Enable</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Range mode disabled. No address matching occurs for an address within the range of values of the A1 and RA registers.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Range mode enabled. Address matching occurs when a slave receives an address within the range of values of the A1 and RA registers.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SBRC</name>
<description>Slave Baud Rate Control</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The slave baud rate follows the master baud rate and clock stretching may occur</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Slave baud rate is independent of the master baud rate</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>HDRS</name>
<description>High Drive Select</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal drive mode</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>High drive mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADEXT</name>
<description>Address Extension</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>7-bit address scheme</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>10-bit address scheme</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>GCAEN</name>
<description>General Call Address Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FLT</name>
<description>I2C Programmable Input Glitch Filter Register</description>
<addressOffset>0x6</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>FLT</name>
<description>I2C Programmable Filter Factor</description>
<bitOffset>0</bitOffset>
<bitWidth>5</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No filter/bypass</description>
<value>#0</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>STOPIE</name>
<description>I2C Bus Stop Interrupt Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Stop detection interrupt is disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Stop detection interrupt is enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>STOPF</name>
<description>I2C Bus Stop Detect Flag</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No stop happens on I2C bus</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Stop detected on I2C bus</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SHEN</name>
<description>Stop Hold Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Stop holdoff is disabled. The MCU&apos;s entry to stop mode is not gated.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Stop holdoff is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>RA</name>
<description>I2C Range Address register</description>
<addressOffset>0x7</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>RAD</name>
<description>Range Slave Address</description>
<bitOffset>1</bitOffset>
<bitWidth>7</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>SMB</name>
<description>I2C SMBus Control and Status register</description>
<addressOffset>0x8</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>SHTF2IE</name>
<description>SHTF2 Interrupt Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>SHTF2 interrupt is disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>SHTF2 interrupt is enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SHTF2</name>
<description>SCL High Timeout Flag 2</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No SCL high and SDA low timeout occurs</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>SCL high and SDA low timeout occurs</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SHTF1</name>
<description>SCL High Timeout Flag 1</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No SCL high and SDA high timeout occurs</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>SCL high and SDA high timeout occurs</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SLTF</name>
<description>SCL Low Timeout Flag</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No low timeout occurs</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Low timeout occurs</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TCKSEL</name>
<description>Timeout Counter Clock Select</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Timeout counter counts at the frequency of the I2C module clock / 64</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Timeout counter counts at the frequency of the I2C module clock</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SIICAEN</name>
<description>Second I2C Address Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>I2C address register 2 matching is disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>I2C address register 2 matching is enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ALERTEN</name>
<description>SMBus Alert Response Address Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>SMBus alert response address matching is disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>SMBus alert response address matching is enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FACK</name>
<description>Fast NACK/ACK Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>An ACK or NACK is sent on the following receiving data byte</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Writing 0 to TXAK after receiving a data byte generates an ACK. Writing 1 to TXAK after receiving a data byte generates a NACK.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>A2</name>
<description>I2C Address Register 2</description>
<addressOffset>0x9</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0xC2</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>SAD</name>
<description>SMBus Address</description>
<bitOffset>1</bitOffset>
<bitWidth>7</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>SLTH</name>
<description>I2C SCL Low Timeout Register High</description>
<addressOffset>0xA</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>SSLT</name>
<description>SSLT[15:8]</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>SLTL</name>
<description>I2C SCL Low Timeout Register Low</description>
<addressOffset>0xB</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>SSLT</name>
<description>SSLT[7:0]</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>S2</name>
<description>I2C Status register 2</description>
<addressOffset>0xC</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0x1</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>EMPTY</name>
<description>Empty flag</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Tx or Rx buffer is not empty and cannot be written to, that is new data cannot be loaded into the buffer.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Tx or Rx buffer is empty and can be written to, that is new data can be loaded into the buffer.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ERROR</name>
<description>Error flag</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The buffer is not full and all write/read operations have no errors.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>There are 3 or more write/read errors during the data transfer phase (when the Empty flag is not set and the buffer is busy).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>I2C1</name>
<description>Inter-Integrated Circuit</description>
<groupName>I2C</groupName>
<prependToName>I2C1_</prependToName>
<baseAddress>0x40067000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0xD</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>I2C1</name>
<value>9</value>
</interrupt>
<registers>
<register>
<name>A1</name>
<description>I2C Address Register 1</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>AD</name>
<description>Address</description>
<bitOffset>1</bitOffset>
<bitWidth>7</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>F</name>
<description>I2C Frequency Divider register</description>
<addressOffset>0x1</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>ICR</name>
<description>ClockRate</description>
<bitOffset>0</bitOffset>
<bitWidth>6</bitWidth>
<access>read-write</access>
</field>
<field>
<name>MULT</name>
<description>Multiplier Factor</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>mul = 1</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>mul = 2</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>mul = 4</description>
<value>#10</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>C1</name>
<description>I2C Control Register 1</description>
<addressOffset>0x2</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>DMAEN</name>
<description>DMA Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>All DMA signalling disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA transfer is enabled. While SMB[FACK] = 0, the following conditions trigger the DMA request: a data byte is received, and either address or data is transmitted. (ACK/NACK is automatic) the first byte received matches the A1 register or is a general call address. If any address matching occurs, S[IAAS] and S[TCF] are set. If the direction of transfer is known from master to slave, then it is not required to check S[SRW]. With this assumption, DMA can also be used in this case. In other cases, if the master reads data from the slave, then it is required to rewrite the C1 register operation. With this assumption, DMA cannot be used. When FACK = 1, an address or a data byte is transmitted.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUEN</name>
<description>Wakeup Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal operation. No interrupt generated when address matching in low power mode.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enables the wakeup function in low power mode.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RSTA</name>
<description>Repeat START</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
</field>
<field>
<name>TXAK</name>
<description>Transmit Acknowledge Enable</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>An acknowledge signal is sent to the bus on the following receiving byte (if FACK is cleared) or the current receiving byte (if FACK is set).</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>No acknowledge signal is sent to the bus on the following receiving data byte (if FACK is cleared) or the current receiving data byte (if FACK is set).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TX</name>
<description>Transmit Mode Select</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Receive</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transmit</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MST</name>
<description>Master Mode Select</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Slave mode</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Master mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IICIE</name>
<description>I2C Interrupt Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IICEN</name>
<description>I2C Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>S</name>
<description>I2C Status register</description>
<addressOffset>0x3</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0x80</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>RXAK</name>
<description>Receive Acknowledge</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Acknowledge signal was received after the completion of one byte of data transmission on the bus</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>No acknowledge signal detected</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IICIF</name>
<description>Interrupt Flag</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No interrupt pending</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Interrupt pending</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SRW</name>
<description>Slave Read/Write</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Slave receive, master writing to slave</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Slave transmit, master reading from slave</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RAM</name>
<description>Range Address Match</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Not addressed</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Addressed as a slave</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ARBL</name>
<description>Arbitration Lost</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Standard bus operation.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Loss of arbitration.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>BUSY</name>
<description>Bus Busy</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Bus is idle</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Bus is busy</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IAAS</name>
<description>Addressed As A Slave</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Not addressed</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Addressed as a slave</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TCF</name>
<description>Transfer Complete Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Transfer in progress</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Transfer complete</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>D</name>
<description>I2C Data I/O register</description>
<addressOffset>0x4</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>DATA</name>
<description>Data</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>C2</name>
<description>I2C Control Register 2</description>
<addressOffset>0x5</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>AD</name>
<description>Slave Address</description>
<bitOffset>0</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
</field>
<field>
<name>RMEN</name>
<description>Range Address Matching Enable</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Range mode disabled. No address matching occurs for an address within the range of values of the A1 and RA registers.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Range mode enabled. Address matching occurs when a slave receives an address within the range of values of the A1 and RA registers.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SBRC</name>
<description>Slave Baud Rate Control</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The slave baud rate follows the master baud rate and clock stretching may occur</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Slave baud rate is independent of the master baud rate</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>HDRS</name>
<description>High Drive Select</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Normal drive mode</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>High drive mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ADEXT</name>
<description>Address Extension</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>7-bit address scheme</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>10-bit address scheme</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>GCAEN</name>
<description>General Call Address Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FLT</name>
<description>I2C Programmable Input Glitch Filter Register</description>
<addressOffset>0x6</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>FLT</name>
<description>I2C Programmable Filter Factor</description>
<bitOffset>0</bitOffset>
<bitWidth>5</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No filter/bypass</description>
<value>#0</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>STOPIE</name>
<description>I2C Bus Stop Interrupt Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Stop detection interrupt is disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Stop detection interrupt is enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>STOPF</name>
<description>I2C Bus Stop Detect Flag</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No stop happens on I2C bus</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Stop detected on I2C bus</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SHEN</name>
<description>Stop Hold Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Stop holdoff is disabled. The MCU&apos;s entry to stop mode is not gated.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Stop holdoff is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>RA</name>
<description>I2C Range Address register</description>
<addressOffset>0x7</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>RAD</name>
<description>Range Slave Address</description>
<bitOffset>1</bitOffset>
<bitWidth>7</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>SMB</name>
<description>I2C SMBus Control and Status register</description>
<addressOffset>0x8</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>SHTF2IE</name>
<description>SHTF2 Interrupt Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>SHTF2 interrupt is disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>SHTF2 interrupt is enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SHTF2</name>
<description>SCL High Timeout Flag 2</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No SCL high and SDA low timeout occurs</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>SCL high and SDA low timeout occurs</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SHTF1</name>
<description>SCL High Timeout Flag 1</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No SCL high and SDA high timeout occurs</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>SCL high and SDA high timeout occurs</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SLTF</name>
<description>SCL Low Timeout Flag</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No low timeout occurs</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Low timeout occurs</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TCKSEL</name>
<description>Timeout Counter Clock Select</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Timeout counter counts at the frequency of the I2C module clock / 64</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Timeout counter counts at the frequency of the I2C module clock</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SIICAEN</name>
<description>Second I2C Address Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>I2C address register 2 matching is disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>I2C address register 2 matching is enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ALERTEN</name>
<description>SMBus Alert Response Address Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>SMBus alert response address matching is disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>SMBus alert response address matching is enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FACK</name>
<description>Fast NACK/ACK Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>An ACK or NACK is sent on the following receiving data byte</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Writing 0 to TXAK after receiving a data byte generates an ACK. Writing 1 to TXAK after receiving a data byte generates a NACK.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>A2</name>
<description>I2C Address Register 2</description>
<addressOffset>0x9</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0xC2</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>SAD</name>
<description>SMBus Address</description>
<bitOffset>1</bitOffset>
<bitWidth>7</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>SLTH</name>
<description>I2C SCL Low Timeout Register High</description>
<addressOffset>0xA</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>SSLT</name>
<description>SSLT[15:8]</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>SLTL</name>
<description>I2C SCL Low Timeout Register Low</description>
<addressOffset>0xB</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>SSLT</name>
<description>SSLT[7:0]</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>S2</name>
<description>I2C Status register 2</description>
<addressOffset>0xC</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0x1</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>EMPTY</name>
<description>Empty flag</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Tx or Rx buffer is not empty and cannot be written to, that is new data cannot be loaded into the buffer.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Tx or Rx buffer is empty and can be written to, that is new data can be loaded into the buffer.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ERROR</name>
<description>Error flag</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The buffer is not full and all write/read operations have no errors.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>There are 3 or more write/read errors during the data transfer phase (when the Empty flag is not set and the buffer is busy).</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>CMP0</name>
<description>High-Speed Comparator (CMP), Voltage Reference (VREF) Digital-to-Analog Converter (DAC), and Analog Mux (ANMUX)</description>
<prependToName>CMP0_</prependToName>
<baseAddress>0x40073000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x6</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>CMP0</name>
<value>16</value>
</interrupt>
<registers>
<register>
<name>CR0</name>
<description>CMP Control Register 0</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>HYSTCTR</name>
<description>Comparator hard block hysteresis control</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Level 0</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Level 1</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Level 2</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Level 3</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FILTER_CNT</name>
<description>Filter Sample Count</description>
<bitOffset>4</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Filter is disabled. SE = 0, COUT = COUTA.</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>One sample must agree. The comparator output is simply sampled.</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>2 consecutive samples must agree.</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>3 consecutive samples must agree.</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>4 consecutive samples must agree.</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>5 consecutive samples must agree.</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>6 consecutive samples must agree.</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>7 consecutive samples must agree.</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CR1</name>
<description>CMP Control Register 1</description>
<addressOffset>0x1</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>EN</name>
<description>Comparator Module Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Analog Comparator is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Analog Comparator is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>OPE</name>
<description>Comparator Output Pin Enable</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>CMPO is not available on the associated CMPO output pin. If the comparator does not own the pin, this field has no effect.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>CMPO is available on the associated CMPO output pin. The comparator output (CMPO) is driven out on the associated CMPO output pin if the comparator owns the pin. If the comparator does not own the field, this bit has no effect.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>COS</name>
<description>Comparator Output Select</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Set the filtered comparator output (CMPO) to equal COUT.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Set the unfiltered comparator output (CMPO) to equal COUTA.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>INV</name>
<description>Comparator INVERT</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Does not invert the comparator output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Inverts the comparator output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PMODE</name>
<description>Power Mode Select</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Low-Speed (LS) Comparison mode selected. In this mode, CMP has slower output propagation delay and lower current consumption.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>High-Speed (HS) Comparison mode selected. In this mode, CMP has faster output propagation delay and higher current consumption.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>TRIGM</name>
<description>Trigger Mode Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Trigger mode is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Trigger mode is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WE</name>
<description>Windowing Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Windowing mode is not selected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Windowing mode is selected.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SE</name>
<description>Sample Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Sampling mode is not selected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Sampling mode is selected.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FPR</name>
<description>CMP Filter Period Register</description>
<addressOffset>0x2</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>FILT_PER</name>
<description>Filter Sample Period</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>SCR</name>
<description>CMP Status and Control Register</description>
<addressOffset>0x3</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>COUT</name>
<description>Analog Comparator Output</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
</field>
<field>
<name>CFF</name>
<description>Analog Comparator Flag Falling</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Falling-edge on COUT has not been detected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Falling-edge on COUT has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CFR</name>
<description>Analog Comparator Flag Rising</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Rising-edge on COUT has not been detected.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Rising-edge on COUT has occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IEF</name>
<description>Comparator Interrupt Enable Falling</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Interrupt is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Interrupt is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>IER</name>
<description>Comparator Interrupt Enable Rising</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Interrupt is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Interrupt is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DMAEN</name>
<description>DMA Enable Control</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DMA is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DMA is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>DACCR</name>
<description>DAC Control Register</description>
<addressOffset>0x4</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>VOSEL</name>
<description>DAC Output Voltage Select</description>
<bitOffset>0</bitOffset>
<bitWidth>6</bitWidth>
<access>read-write</access>
</field>
<field>
<name>VRSEL</name>
<description>Supply Voltage Reference Source Select</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Vin1 is selected as resistor ladder network supply reference.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Vin2 is selected as resistor ladder network supply reference.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DACEN</name>
<description>DAC Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>DAC is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>DAC is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>MUXCR</name>
<description>MUX Control Register</description>
<addressOffset>0x5</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>MSEL</name>
<description>Minus Input Mux Control</description>
<bitOffset>0</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>IN0</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>IN1</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>IN2</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>IN3</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>IN4</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>IN5</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>IN6</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>IN7</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PSEL</name>
<description>Plus Input Mux Control</description>
<bitOffset>3</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>IN0</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>IN1</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>IN2</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>IN3</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>IN4</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>101</name>
<description>IN5</description>
<value>#101</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>IN6</description>
<value>#110</value>
</enumeratedValue>
<enumeratedValue>
<name>111</name>
<description>IN7</description>
<value>#111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PSTM</name>
<description>Pass Through Mode Enable</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pass Through Mode is disabled.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pass Through Mode is enabled.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>LLWU</name>
<description>Low leakage wakeup unit</description>
<prependToName>LLWU_</prependToName>
<baseAddress>0x4007C000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0xA</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>LLWU</name>
<value>7</value>
</interrupt>
<registers>
<register>
<name>PE1</name>
<description>LLWU Pin Enable 1 register</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>WUPE0</name>
<description>Wakeup Pin Enable For LLWU_P0</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUPE1</name>
<description>Wakeup Pin Enable For LLWU_P1</description>
<bitOffset>2</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUPE2</name>
<description>Wakeup Pin Enable For LLWU_P2</description>
<bitOffset>4</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUPE3</name>
<description>Wakeup Pin Enable For LLWU_P3</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PE2</name>
<description>LLWU Pin Enable 2 register</description>
<addressOffset>0x1</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>WUPE4</name>
<description>Wakeup Pin Enable For LLWU_P4</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUPE5</name>
<description>Wakeup Pin Enable For LLWU_P5</description>
<bitOffset>2</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUPE6</name>
<description>Wakeup Pin Enable For LLWU_P6</description>
<bitOffset>4</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUPE7</name>
<description>Wakeup Pin Enable For LLWU_P7</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PE3</name>
<description>LLWU Pin Enable 3 register</description>
<addressOffset>0x2</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>WUPE8</name>
<description>Wakeup Pin Enable For LLWU_P8</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUPE9</name>
<description>Wakeup Pin Enable For LLWU_P9</description>
<bitOffset>2</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUPE10</name>
<description>Wakeup Pin Enable For LLWU_P10</description>
<bitOffset>4</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUPE11</name>
<description>Wakeup Pin Enable For LLWU_P11</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PE4</name>
<description>LLWU Pin Enable 4 register</description>
<addressOffset>0x3</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>WUPE12</name>
<description>Wakeup Pin Enable For LLWU_P12</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUPE13</name>
<description>Wakeup Pin Enable For LLWU_P13</description>
<bitOffset>2</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUPE14</name>
<description>Wakeup Pin Enable For LLWU_P14</description>
<bitOffset>4</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUPE15</name>
<description>Wakeup Pin Enable For LLWU_P15</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>External input pin disabled as wakeup input</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>External input pin enabled with rising edge detection</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>External input pin enabled with falling edge detection</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>External input pin enabled with any change detection</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>ME</name>
<description>LLWU Module Enable register</description>
<addressOffset>0x4</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>WUME0</name>
<description>Wakeup Module Enable For Module 0</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal module flag not used as wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal module flag used as wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUME1</name>
<description>Wakeup Module Enable for Module 1</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal module flag not used as wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal module flag used as wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUME2</name>
<description>Wakeup Module Enable For Module 2</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal module flag not used as wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal module flag used as wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUME3</name>
<description>Wakeup Module Enable For Module 3</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal module flag not used as wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal module flag used as wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUME4</name>
<description>Wakeup Module Enable For Module 4</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal module flag not used as wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal module flag used as wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUME5</name>
<description>Wakeup Module Enable For Module 5</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal module flag not used as wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal module flag used as wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUME6</name>
<description>Wakeup Module Enable For Module 6</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal module flag not used as wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal module flag used as wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUME7</name>
<description>Wakeup Module Enable For Module 7</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Internal module flag not used as wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Internal module flag used as wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>F1</name>
<description>LLWU Flag 1 register</description>
<addressOffset>0x5</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>WUF0</name>
<description>Wakeup Flag For LLWU_P0</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P0 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P0 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF1</name>
<description>Wakeup Flag For LLWU_P1</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P1 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P1 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF2</name>
<description>Wakeup Flag For LLWU_P2</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P2 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P2 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF3</name>
<description>Wakeup Flag For LLWU_P3</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P3 input was not a wake-up source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P3 input was a wake-up source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF4</name>
<description>Wakeup Flag For LLWU_P4</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P4 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P4 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF5</name>
<description>Wakeup Flag For LLWU_P5</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P5 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P5 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF6</name>
<description>Wakeup Flag For LLWU_P6</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P6 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P6 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF7</name>
<description>Wakeup Flag For LLWU_P7</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P7 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P7 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>F2</name>
<description>LLWU Flag 2 register</description>
<addressOffset>0x6</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>WUF8</name>
<description>Wakeup Flag For LLWU_P8</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P8 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P8 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF9</name>
<description>Wakeup Flag For LLWU_P9</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P9 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P9 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF10</name>
<description>Wakeup Flag For LLWU_P10</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P10 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P10 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF11</name>
<description>Wakeup Flag For LLWU_P11</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P11 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P11 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF12</name>
<description>Wakeup Flag For LLWU_P12</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P12 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P12 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF13</name>
<description>Wakeup Flag For LLWU_P13</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P13 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P13 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF14</name>
<description>Wakeup Flag For LLWU_P14</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P14 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P14 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WUF15</name>
<description>Wakeup Flag For LLWU_P15</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LLWU_P15 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LLWU_P15 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>F3</name>
<description>LLWU Flag 3 register</description>
<addressOffset>0x7</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>MWUF0</name>
<description>Wakeup flag For module 0</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Module 0 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Module 0 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MWUF1</name>
<description>Wakeup flag For module 1</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Module 1 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Module 1 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MWUF2</name>
<description>Wakeup flag For module 2</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Module 2 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Module 2 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MWUF3</name>
<description>Wakeup flag For module 3</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Module 3 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Module 3 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MWUF4</name>
<description>Wakeup flag For module 4</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Module 4 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Module 4 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MWUF5</name>
<description>Wakeup flag For module 5</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Module 5 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Module 5 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MWUF6</name>
<description>Wakeup flag For module 6</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Module 6 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Module 6 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MWUF7</name>
<description>Wakeup flag For module 7</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Module 7 input was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Module 7 input was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FILT1</name>
<description>LLWU Pin Filter 1 register</description>
<addressOffset>0x8</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>FILTSEL</name>
<description>Filter Pin Select</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Select LLWU_P0 for filter</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>1111</name>
<description>Select LLWU_P15 for filter</description>
<value>#1111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FILTE</name>
<description>Digital Filter On External Pin</description>
<bitOffset>5</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Filter disabled</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Filter posedge detect enabled</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Filter negedge detect enabled</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Filter any edge detect enabled</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FILTF</name>
<description>Filter Detect Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin Filter 1 was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin Filter 1 was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FILT2</name>
<description>LLWU Pin Filter 2 register</description>
<addressOffset>0x9</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>FILTSEL</name>
<description>Filter Pin Select</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Select LLWU_P0 for filter</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>1111</name>
<description>Select LLWU_P15 for filter</description>
<value>#1111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FILTE</name>
<description>Digital Filter On External Pin</description>
<bitOffset>5</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Filter disabled</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Filter posedge detect enabled</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Filter negedge detect enabled</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Filter any edge detect enabled</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>FILTF</name>
<description>Filter Detect Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin Filter 2 was not a wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin Filter 2 was a wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>PMC</name>
<description>Power Management Controller</description>
<prependToName>PMC_</prependToName>
<baseAddress>0x4007D000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x3</size>
<usage>registers</usage>
</addressBlock>
<interrupt>
<name>PMC_DCDC</name>
<value>6</value>
</interrupt>
<registers>
<register>
<name>LVDSC1</name>
<description>Low Voltage Detect Status And Control 1 register</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0x10</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>LVDV</name>
<description>Low-Voltage Detect Voltage Select</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Low trip point selected (V LVD = V LVDL )</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>High trip point selected (V LVD = V LVDH )</description>
<value>#01</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LVDRE</name>
<description>Low-Voltage Detect Reset Enable</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>LVDF does not generate hardware resets</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Force an MCU reset when LVDF = 1</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LVDIE</name>
<description>Low-Voltage Detect Interrupt Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Hardware interrupt disabled (use polling)</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Request a hardware interrupt when LVDF = 1</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LVDACK</name>
<description>Low-Voltage Detect Acknowledge</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
</field>
<field>
<name>LVDF</name>
<description>Low-Voltage Detect Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Low-voltage event not detected</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Low-voltage event detected</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>LVDSC2</name>
<description>Low Voltage Detect Status And Control 2 register</description>
<addressOffset>0x1</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>LVWV</name>
<description>Low-Voltage Warning Voltage Select</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Low trip point selected (VLVW = VLVW1)</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Mid 1 trip point selected (VLVW = VLVW2)</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Mid 2 trip point selected (VLVW = VLVW3)</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>High trip point selected (VLVW = VLVW4)</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LVWIE</name>
<description>Low-Voltage Warning Interrupt Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Hardware interrupt disabled (use polling)</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Request a hardware interrupt when LVWF = 1</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LVWACK</name>
<description>Low-Voltage Warning Acknowledge</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
</field>
<field>
<name>LVWF</name>
<description>Low-Voltage Warning Flag</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Low-voltage warning event not detected</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Low-voltage warning event detected</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>REGSC</name>
<description>Regulator Status And Control register</description>
<addressOffset>0x2</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0x4</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>BGBE</name>
<description>Bandgap Buffer Enable</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Bandgap buffer not enabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Bandgap buffer enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>REGONS</name>
<description>Regulator In Run Regulation Status</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Regulator is in stop regulation or in transition to/from it</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Regulator is in run regulation</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ACKISO</name>
<description>Acknowledge Isolation</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Peripherals and I/O pads are in normal run state.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Certain peripherals and I/O pads are in an isolated and latched state.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>BGEN</name>
<description>Bandgap Enable In VLPx Operation</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Bandgap voltage reference is disabled in VLPx , LLS , and VLLSx modes.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Bandgap voltage reference is enabled in VLPx , LLS , and VLLSx modes.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>SMC</name>
<description>System Mode Controller</description>
<prependToName>SMC_</prependToName>
<baseAddress>0x4007E000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x4</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>PMPROT</name>
<description>Power Mode Protection register</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>AVLLS</name>
<description>Allow Very-Low-Leakage Stop Mode</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Any VLLSx mode is not allowed</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Any VLLSx mode is allowed</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ALLS</name>
<description>Allow Low-Leakage Stop Mode</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Any LLSx mode is not allowed</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Any LLSx mode is allowed</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>AVLP</name>
<description>Allow Very-Low-Power Modes</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>VLPR, VLPW, and VLPS are not allowed.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>VLPR, VLPW, and VLPS are allowed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PMCTRL</name>
<description>Power Mode Control register</description>
<addressOffset>0x1</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>STOPM</name>
<description>Stop Mode Control</description>
<bitOffset>0</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>Normal Stop (STOP)</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>Very-Low-Power Stop (VLPS)</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>Low-Leakage Stop (LLSx)</description>
<value>#011</value>
</enumeratedValue>
<enumeratedValue>
<name>100</name>
<description>Very-Low-Leakage Stop (VLLSx)</description>
<value>#100</value>
</enumeratedValue>
<enumeratedValue>
<name>110</name>
<description>Reseved</description>
<value>#110</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>STOPA</name>
<description>Stop Aborted</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>The previous stop mode entry was successsful.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>The previous stop mode entry was aborted.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RUNM</name>
<description>Run Mode Control</description>
<bitOffset>5</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Normal Run mode (RUN)</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Very-Low-Power Run mode (VLPR)</description>
<value>#10</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>STOPCTRL</name>
<description>Stop Control Register</description>
<addressOffset>0x2</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0x3</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>LLSM</name>
<description>LLS or VLLS Mode Control</description>
<bitOffset>0</bitOffset>
<bitWidth>3</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>000</name>
<description>VLLS0 if PMCTRL[STOPM]=VLLSx, reserved if PMCTRL[STOPM]=LLSx</description>
<value>#000</value>
</enumeratedValue>
<enumeratedValue>
<name>001</name>
<description>VLLS1 if PMCTRL[STOPM]=VLLSx, reserved if PMCTRL[STOPM]=LLSx</description>
<value>#001</value>
</enumeratedValue>
<enumeratedValue>
<name>010</name>
<description>VLLS2 if PMCTRL[STOPM]=VLLSx, LLS2 if PMCTRL[STOPM]=LLSx</description>
<value>#010</value>
</enumeratedValue>
<enumeratedValue>
<name>011</name>
<description>VLLS3 if PMCTRL[STOPM]=VLLSx, LLS3 if PMCTRL[STOPM]=LLSx</description>
<value>#011</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RAM2PO</name>
<description>RAM2 Power Option</description>
<bitOffset>4</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>RAM2 not powered in LLS2/VLLS2</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>RAM2 powered in LLS2/VLLS2</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PORPO</name>
<description>POR Power Option</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>POR detect circuit is enabled in VLLS0</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>POR detect circuit is disabled in VLLS0</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PSTOPO</name>
<description>Partial Stop Option</description>
<bitOffset>6</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>STOP - Normal Stop mode</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>PSTOP1 - Partial Stop with both system and bus clocks disabled</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>PSTOP2 - Partial Stop with system clock disabled and bus clock enabled</description>
<value>#10</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PMSTAT</name>
<description>Power Mode Status register</description>
<addressOffset>0x3</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0x1</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>PMSTAT</name>
<description>Power Mode Status</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>RCM</name>
<description>Reset Control Module</description>
<prependToName>RCM_</prependToName>
<baseAddress>0x4007F000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x6</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>SRS0</name>
<description>System Reset Status Register 0</description>
<addressOffset>0</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0x82</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>WAKEUP</name>
<description>Low Leakage Wakeup Reset</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Reset not caused by LLWU module wakeup source</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Reset caused by LLWU module wakeup source</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LVD</name>
<description>Low-Voltage Detect Reset</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Reset not caused by LVD trip or POR</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Reset caused by LVD trip or POR</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>LOC</name>
<description>Loss-of-Clock Reset</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Reset not caused by a loss of external clock.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Reset caused by a loss of external clock.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>WDOG</name>
<description>Watchdog</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Reset not caused by watchdog timeout</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Reset caused by watchdog timeout</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>PIN</name>
<description>External Reset Pin</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Reset not caused by external reset pin</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Reset caused by external reset pin</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>POR</name>
<description>Power-On Reset</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Reset not caused by POR</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Reset caused by POR</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>SRS1</name>
<description>System Reset Status Register 1</description>
<addressOffset>0x1</addressOffset>
<size>8</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>LOCKUP</name>
<description>Core Lockup</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Reset not caused by core LOCKUP event</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Reset caused by core LOCKUP event</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SW</name>
<description>Software</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Reset not caused by software setting of SYSRESETREQ bit</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Reset caused by software setting of SYSRESETREQ bit</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MDM_AP</name>
<description>MDM-AP System Reset Request</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Reset not caused by host debugger system setting of the System Reset Request bit</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Reset caused by host debugger system setting of the System Reset Request bit</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>SACKERR</name>
<description>Stop Mode Acknowledge Error Reset</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Reset not caused by peripheral failure to acknowledge attempt to enter stop mode</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Reset caused by peripheral failure to acknowledge attempt to enter stop mode</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>RPFC</name>
<description>Reset Pin Filter Control register</description>
<addressOffset>0x4</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>RSTFLTSRW</name>
<description>Reset Pin Filter Select in Run and Wait Modes</description>
<bitOffset>0</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>All filtering disabled</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Bus clock filter enabled for normal operation</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>LPO clock filter enabled for normal operation</description>
<value>#10</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>RSTFLTSS</name>
<description>Reset Pin Filter Select in Stop Mode</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>All filtering disabled</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>LPO clock filter enabled</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>RPFW</name>
<description>Reset Pin Filter Width register</description>
<addressOffset>0x5</addressOffset>
<size>8</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFF</resetMask>
<fields>
<field>
<name>RSTFLTSEL</name>
<description>Reset Pin Filter Bus Clock Select</description>
<bitOffset>0</bitOffset>
<bitWidth>5</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00000</name>
<description>Bus clock filter count is 1</description>
<value>#00000</value>
</enumeratedValue>
<enumeratedValue>
<name>00001</name>
<description>Bus clock filter count is 2</description>
<value>#00001</value>
</enumeratedValue>
<enumeratedValue>
<name>00010</name>
<description>Bus clock filter count is 3</description>
<value>#00010</value>
</enumeratedValue>
<enumeratedValue>
<name>00011</name>
<description>Bus clock filter count is 4</description>
<value>#00011</value>
</enumeratedValue>
<enumeratedValue>
<name>00100</name>
<description>Bus clock filter count is 5</description>
<value>#00100</value>
</enumeratedValue>
<enumeratedValue>
<name>00101</name>
<description>Bus clock filter count is 6</description>
<value>#00101</value>
</enumeratedValue>
<enumeratedValue>
<name>00110</name>
<description>Bus clock filter count is 7</description>
<value>#00110</value>
</enumeratedValue>
<enumeratedValue>
<name>00111</name>
<description>Bus clock filter count is 8</description>
<value>#00111</value>
</enumeratedValue>
<enumeratedValue>
<name>01000</name>
<description>Bus clock filter count is 9</description>
<value>#01000</value>
</enumeratedValue>
<enumeratedValue>
<name>01001</name>
<description>Bus clock filter count is 10</description>
<value>#01001</value>
</enumeratedValue>
<enumeratedValue>
<name>01010</name>
<description>Bus clock filter count is 11</description>
<value>#01010</value>
</enumeratedValue>
<enumeratedValue>
<name>01011</name>
<description>Bus clock filter count is 12</description>
<value>#01011</value>
</enumeratedValue>
<enumeratedValue>
<name>01100</name>
<description>Bus clock filter count is 13</description>
<value>#01100</value>
</enumeratedValue>
<enumeratedValue>
<name>01101</name>
<description>Bus clock filter count is 14</description>
<value>#01101</value>
</enumeratedValue>
<enumeratedValue>
<name>01110</name>
<description>Bus clock filter count is 15</description>
<value>#01110</value>
</enumeratedValue>
<enumeratedValue>
<name>01111</name>
<description>Bus clock filter count is 16</description>
<value>#01111</value>
</enumeratedValue>
<enumeratedValue>
<name>10000</name>
<description>Bus clock filter count is 17</description>
<value>#10000</value>
</enumeratedValue>
<enumeratedValue>
<name>10001</name>
<description>Bus clock filter count is 18</description>
<value>#10001</value>
</enumeratedValue>
<enumeratedValue>
<name>10010</name>
<description>Bus clock filter count is 19</description>
<value>#10010</value>
</enumeratedValue>
<enumeratedValue>
<name>10011</name>
<description>Bus clock filter count is 20</description>
<value>#10011</value>
</enumeratedValue>
<enumeratedValue>
<name>10100</name>
<description>Bus clock filter count is 21</description>
<value>#10100</value>
</enumeratedValue>
<enumeratedValue>
<name>10101</name>
<description>Bus clock filter count is 22</description>
<value>#10101</value>
</enumeratedValue>
<enumeratedValue>
<name>10110</name>
<description>Bus clock filter count is 23</description>
<value>#10110</value>
</enumeratedValue>
<enumeratedValue>
<name>10111</name>
<description>Bus clock filter count is 24</description>
<value>#10111</value>
</enumeratedValue>
<enumeratedValue>
<name>11000</name>
<description>Bus clock filter count is 25</description>
<value>#11000</value>
</enumeratedValue>
<enumeratedValue>
<name>11001</name>
<description>Bus clock filter count is 26</description>
<value>#11001</value>
</enumeratedValue>
<enumeratedValue>
<name>11010</name>
<description>Bus clock filter count is 27</description>
<value>#11010</value>
</enumeratedValue>
<enumeratedValue>
<name>11011</name>
<description>Bus clock filter count is 28</description>
<value>#11011</value>
</enumeratedValue>
<enumeratedValue>
<name>11100</name>
<description>Bus clock filter count is 29</description>
<value>#11100</value>
</enumeratedValue>
<enumeratedValue>
<name>11101</name>
<description>Bus clock filter count is 30</description>
<value>#11101</value>
</enumeratedValue>
<enumeratedValue>
<name>11110</name>
<description>Bus clock filter count is 31</description>
<value>#11110</value>
</enumeratedValue>
<enumeratedValue>
<name>11111</name>
<description>Bus clock filter count is 32</description>
<value>#11111</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>PTA</name>
<description>General Purpose Input/Output</description>
<groupName>GPIO</groupName>
<prependToName>GPIOA_</prependToName>
<baseAddress>0x400FF000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x18</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>PDOR</name>
<description>Port Data Output Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDO</name>
<description>Port Data Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Logic level 0 is driven on pin, provided pin is configured for general-purpose output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Logic level 1 is driven on pin, provided pin is configured for general-purpose output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PSOR</name>
<description>Port Set Output Register</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTSO</name>
<description>Port Set Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is set to logic 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PCOR</name>
<description>Port Clear Output Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTCO</name>
<description>Port Clear Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is cleared to logic 0.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PTOR</name>
<description>Port Toggle Output Register</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTTO</name>
<description>Port Toggle Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is set to the inverse of its existing logic state.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PDIR</name>
<description>Port Data Input Register</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDI</name>
<description>Port Data Input</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin logic level is logic 0, or is not configured for use by digital function.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin logic level is logic 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PDDR</name>
<description>Port Data Direction Register</description>
<addressOffset>0x14</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDD</name>
<description>Port Data Direction</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin is configured as general-purpose input, for the GPIO function.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin is configured as general-purpose output, for the GPIO function.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>PTB</name>
<description>General Purpose Input/Output</description>
<groupName>GPIO</groupName>
<prependToName>GPIOB_</prependToName>
<baseAddress>0x400FF040</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x18</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>PDOR</name>
<description>Port Data Output Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDO</name>
<description>Port Data Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Logic level 0 is driven on pin, provided pin is configured for general-purpose output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Logic level 1 is driven on pin, provided pin is configured for general-purpose output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PSOR</name>
<description>Port Set Output Register</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTSO</name>
<description>Port Set Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is set to logic 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PCOR</name>
<description>Port Clear Output Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTCO</name>
<description>Port Clear Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is cleared to logic 0.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PTOR</name>
<description>Port Toggle Output Register</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTTO</name>
<description>Port Toggle Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is set to the inverse of its existing logic state.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PDIR</name>
<description>Port Data Input Register</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDI</name>
<description>Port Data Input</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin logic level is logic 0, or is not configured for use by digital function.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin logic level is logic 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PDDR</name>
<description>Port Data Direction Register</description>
<addressOffset>0x14</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDD</name>
<description>Port Data Direction</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin is configured as general-purpose input, for the GPIO function.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin is configured as general-purpose output, for the GPIO function.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>PTC</name>
<description>General Purpose Input/Output</description>
<groupName>GPIO</groupName>
<prependToName>GPIOC_</prependToName>
<baseAddress>0x400FF080</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x18</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>PDOR</name>
<description>Port Data Output Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDO</name>
<description>Port Data Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Logic level 0 is driven on pin, provided pin is configured for general-purpose output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Logic level 1 is driven on pin, provided pin is configured for general-purpose output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PSOR</name>
<description>Port Set Output Register</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTSO</name>
<description>Port Set Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is set to logic 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PCOR</name>
<description>Port Clear Output Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTCO</name>
<description>Port Clear Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is cleared to logic 0.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PTOR</name>
<description>Port Toggle Output Register</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTTO</name>
<description>Port Toggle Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is set to the inverse of its existing logic state.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PDIR</name>
<description>Port Data Input Register</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDI</name>
<description>Port Data Input</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin logic level is logic 0, or is not configured for use by digital function.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin logic level is logic 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PDDR</name>
<description>Port Data Direction Register</description>
<addressOffset>0x14</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDD</name>
<description>Port Data Direction</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin is configured as general-purpose input, for the GPIO function.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin is configured as general-purpose output, for the GPIO function.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>MTB</name>
<description>Micro Trace Buffer</description>
<prependToName>MTB_</prependToName>
<baseAddress>0xF0000000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x1000</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>POSITION</name>
<description>MTB Position Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0x3</resetMask>
<fields>
<field>
<name>WRAP</name>
<description>WRAP</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>POINTER</name>
<description>Trace Packet Address Pointer[28:0]</description>
<bitOffset>3</bitOffset>
<bitWidth>29</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>MASTER</name>
<description>MTB Master Register</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x80</resetValue>
<resetMask>0xFFFFFFE0</resetMask>
<fields>
<field>
<name>MASK</name>
<description>Mask</description>
<bitOffset>0</bitOffset>
<bitWidth>5</bitWidth>
<access>read-write</access>
</field>
<field>
<name>TSTARTEN</name>
<description>Trace Start Input Enable</description>
<bitOffset>5</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>TSTOPEN</name>
<description>Trace Stop Input Enable</description>
<bitOffset>6</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>SFRWPRIV</name>
<description>Special Function Register Write Privilege</description>
<bitOffset>7</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>RAMPRIV</name>
<description>RAM Privilege</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>HALTREQ</name>
<description>Halt Request</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>EN</name>
<description>Main Trace Enable</description>
<bitOffset>31</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>FLOW</name>
<description>MTB Flow Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0x4</resetMask>
<fields>
<field>
<name>AUTOSTOP</name>
<description>AUTOSTOP</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>AUTOHALT</name>
<description>AUTOHALT</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
</field>
<field>
<name>WATERMARK</name>
<description>WATERMARK[28:0]</description>
<bitOffset>3</bitOffset>
<bitWidth>29</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>BASE</name>
<description>MTB Base Register</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>BASEADDR</name>
<description>BASEADDR</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>MODECTRL</name>
<description>Integration Mode Control Register</description>
<addressOffset>0xF00</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>MODECTRL</name>
<description>MODECTRL</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>TAGSET</name>
<description>Claim TAG Set Register</description>
<addressOffset>0xFA0</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TAGSET</name>
<description>TAGSET</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>TAGCLEAR</name>
<description>Claim TAG Clear Register</description>
<addressOffset>0xFA4</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>TAGCLEAR</name>
<description>TAGCLEAR</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>LOCKACCESS</name>
<description>Lock Access Register</description>
<addressOffset>0xFB0</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>LOCKACCESS</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>LOCKSTAT</name>
<description>Lock Status Register</description>
<addressOffset>0xFB4</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>LOCKSTAT</name>
<description>LOCKSTAT</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>AUTHSTAT</name>
<description>Authentication Status Register</description>
<addressOffset>0xFB8</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>BIT0</name>
<description>no description available</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
</field>
<field>
<name>BIT1</name>
<description>BIT1</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
</field>
<field>
<name>BIT2</name>
<description>BIT2</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
</field>
<field>
<name>BIT3</name>
<description>BIT3</description>
<bitOffset>3</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>DEVICEARCH</name>
<description>Device Architecture Register</description>
<addressOffset>0xFBC</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0x47700A31</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DEVICEARCH</name>
<description>DEVICEARCH</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>DEVICECFG</name>
<description>Device Configuration Register</description>
<addressOffset>0xFC8</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DEVICECFG</name>
<description>DEVICECFG</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>DEVICETYPID</name>
<description>Device Type Identifier Register</description>
<addressOffset>0xFCC</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0x31</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DEVICETYPID</name>
<description>DEVICETYPID</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>8</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>4,5,6,7,0,1,2,3</dimIndex>
<name>PERIPHID%s</name>
<description>Peripheral ID Register</description>
<addressOffset>0xFD0</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>PERIPHID</name>
<description>PERIPHID</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>COMPID%s</name>
<description>Component ID Register</description>
<addressOffset>0xFF0</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>COMPID</name>
<description>Component ID</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>MTBDWT</name>
<description>MTB data watchpoint and trace</description>
<prependToName>MTBDWT_</prependToName>
<baseAddress>0xF0001000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x1000</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>CTRL</name>
<description>MTB DWT Control Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0x2F000000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DWTCFGCTRL</name>
<description>DWT configuration controls</description>
<bitOffset>0</bitOffset>
<bitWidth>28</bitWidth>
<access>read-only</access>
</field>
<field>
<name>NUMCMP</name>
<description>Number of comparators</description>
<bitOffset>28</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>2</dim>
<dimIncrement>0x10</dimIncrement>
<dimIndex>0,1</dimIndex>
<name>COMP%s</name>
<description>MTB_DWT Comparator Register</description>
<addressOffset>0x20</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>COMP</name>
<description>Reference value for comparison</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<dim>2</dim>
<dimIncrement>0x10</dimIncrement>
<dimIndex>0,1</dimIndex>
<name>MASK%s</name>
<description>MTB_DWT Comparator Mask Register</description>
<addressOffset>0x24</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>MASK</name>
<description>MASK</description>
<bitOffset>0</bitOffset>
<bitWidth>5</bitWidth>
<access>read-write</access>
</field>
</fields>
</register>
<register>
<name>FCT0</name>
<description>MTB_DWT Comparator Function Register 0</description>
<addressOffset>0x28</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>FUNCTION</name>
<description>Function</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Disabled.</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0100</name>
<description>Instruction fetch.</description>
<value>#0100</value>
</enumeratedValue>
<enumeratedValue>
<name>0101</name>
<description>Data operand read.</description>
<value>#0101</value>
</enumeratedValue>
<enumeratedValue>
<name>0110</name>
<description>Data operand write.</description>
<value>#0110</value>
</enumeratedValue>
<enumeratedValue>
<name>0111</name>
<description>Data operand (read + write).</description>
<value>#0111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DATAVMATCH</name>
<description>Data Value Match</description>
<bitOffset>8</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Perform address comparison.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Perform data value comparison.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DATAVSIZE</name>
<description>Data Value Size</description>
<bitOffset>10</bitOffset>
<bitWidth>2</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>00</name>
<description>Byte.</description>
<value>#00</value>
</enumeratedValue>
<enumeratedValue>
<name>01</name>
<description>Halfword.</description>
<value>#01</value>
</enumeratedValue>
<enumeratedValue>
<name>10</name>
<description>Word.</description>
<value>#10</value>
</enumeratedValue>
<enumeratedValue>
<name>11</name>
<description>Reserved. Any attempts to use this value results in UNPREDICTABLE behavior.</description>
<value>#11</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DATAVADDR0</name>
<description>Data Value Address 0</description>
<bitOffset>12</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
</field>
<field>
<name>MATCHED</name>
<description>Comparator match</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No match.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Match occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>FCT1</name>
<description>MTB_DWT Comparator Function Register 1</description>
<addressOffset>0x38</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>FUNCTION</name>
<description>Function</description>
<bitOffset>0</bitOffset>
<bitWidth>4</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0000</name>
<description>Disabled.</description>
<value>#0000</value>
</enumeratedValue>
<enumeratedValue>
<name>0100</name>
<description>Instruction fetch.</description>
<value>#0100</value>
</enumeratedValue>
<enumeratedValue>
<name>0101</name>
<description>Data operand read.</description>
<value>#0101</value>
</enumeratedValue>
<enumeratedValue>
<name>0110</name>
<description>Data operand write.</description>
<value>#0110</value>
</enumeratedValue>
<enumeratedValue>
<name>0111</name>
<description>Data operand (read + write).</description>
<value>#0111</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>MATCHED</name>
<description>Comparator match</description>
<bitOffset>24</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No match.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Match occurred.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>TBCTRL</name>
<description>MTB_DWT Trace Buffer Control Register</description>
<addressOffset>0x200</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x20000000</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>ACOMP0</name>
<description>Action based on Comparator 0 match</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Trigger TSTOP based on the assertion of MTBDWT_FCT0[MATCHED].</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Trigger TSTART based on the assertion of MTBDWT_FCT0[MATCHED].</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ACOMP1</name>
<description>Action based on Comparator 1 match</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Trigger TSTOP based on the assertion of MTBDWT_FCT1[MATCHED].</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Trigger TSTART based on the assertion of MTBDWT_FCT1[MATCHED].</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>NUMCOMP</name>
<description>Number of Comparators</description>
<bitOffset>28</bitOffset>
<bitWidth>4</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>DEVICECFG</name>
<description>Device Configuration Register</description>
<addressOffset>0xFC8</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DEVICECFG</name>
<description>DEVICECFG</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>DEVICETYPID</name>
<description>Device Type Identifier Register</description>
<addressOffset>0xFCC</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0x4</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>DEVICETYPID</name>
<description>DEVICETYPID</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>8</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>4,5,6,7,0,1,2,3</dimIndex>
<name>PERIPHID%s</name>
<description>Peripheral ID Register</description>
<addressOffset>0xFD0</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>PERIPHID</name>
<description>PERIPHID</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>COMPID%s</name>
<description>Component ID Register</description>
<addressOffset>0xFF0</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>COMPID</name>
<description>Component ID</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>ROM</name>
<description>System ROM</description>
<prependToName>ROM_</prependToName>
<baseAddress>0xF0002000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x1000</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<dim>3</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1,2</dimIndex>
<name>ENTRY%s</name>
<description>Entry</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>ENTRY</name>
<description>ENTRY</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>TABLEMARK</name>
<description>End of Table Marker Register</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>MARK</name>
<description>MARK</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<name>SYSACCESS</name>
<description>System Access Register</description>
<addressOffset>0xFCC</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0x1</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>SYSACCESS</name>
<description>SYSACCESS</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>8</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>4,5,6,7,0,1,2,3</dimIndex>
<name>PERIPHID%s</name>
<description>Peripheral ID Register</description>
<addressOffset>0xFD0</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>PERIPHID</name>
<description>PERIPHID</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
<register>
<dim>4</dim>
<dimIncrement>0x4</dimIncrement>
<dimIndex>0,1,2,3</dimIndex>
<name>COMPID%s</name>
<description>Component ID Register</description>
<addressOffset>0xFF0</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0</resetMask>
<fields>
<field>
<name>COMPID</name>
<description>Component ID</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>MCM</name>
<description>Core Platform Miscellaneous Control Module</description>
<prependToName>MCM_</prependToName>
<baseAddress>0xF0003000</baseAddress>
<addressBlock>
<offset>0x8</offset>
<size>0x3C</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>PLASC</name>
<description>Crossbar Switch (AXBS) Slave Configuration</description>
<addressOffset>0x8</addressOffset>
<size>16</size>
<access>read-only</access>
<resetValue>0x7</resetValue>
<resetMask>0xFFFF</resetMask>
<fields>
<field>
<name>ASC</name>
<description>Each bit in the ASC field indicates whether there is a corresponding connection to the crossbar switch&apos;s slave input port.</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>A bus slave connection to AXBS input port n is absent.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A bus slave connection to AXBS input port n is present.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PLAMC</name>
<description>Crossbar Switch (AXBS) Master Configuration</description>
<addressOffset>0xA</addressOffset>
<size>16</size>
<access>read-only</access>
<resetValue>0x5</resetValue>
<resetMask>0xFFFF</resetMask>
<fields>
<field>
<name>AMC</name>
<description>Each bit in the AMC field indicates whether there is a corresponding connection to the AXBS master input port.</description>
<bitOffset>0</bitOffset>
<bitWidth>8</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>A bus master connection to AXBS input port n is absent</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>A bus master connection to AXBS input port n is present</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PLACR</name>
<description>Platform Control Register</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0x50</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>ARB</name>
<description>Arbitration select</description>
<bitOffset>9</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Fixed-priority arbitration for the crossbar masters</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Round-robin arbitration for the crossbar masters</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CFCC</name>
<description>Clear Flash Controller Cache</description>
<bitOffset>10</bitOffset>
<bitWidth>1</bitWidth>
<access>write-only</access>
</field>
<field>
<name>DFCDA</name>
<description>Disable Flash Controller Data Caching</description>
<bitOffset>11</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Enable flash controller data caching</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Disable flash controller data caching.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DFCIC</name>
<description>Disable Flash Controller Instruction Caching</description>
<bitOffset>12</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Enable flash controller instruction caching.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Disable flash controller instruction caching.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DFCC</name>
<description>Disable Flash Controller Cache</description>
<bitOffset>13</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Enable flash controller cache.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Disable flash controller cache.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>EFDS</name>
<description>Enable Flash Data Speculation</description>
<bitOffset>14</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable flash data speculation.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable flash data speculation.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>DFCS</name>
<description>Disable Flash Controller Speculation</description>
<bitOffset>15</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Enable flash controller speculation.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Disable flash controller speculation.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>ESFC</name>
<description>Enable Stalling Flash Controller</description>
<bitOffset>16</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Disable stalling flash controller when flash is busy.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Enable stalling flash controller when flash is busy.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>CPO</name>
<description>Compute Operation Control Register</description>
<addressOffset>0x40</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>CPOREQ</name>
<description>Compute Operation Request</description>
<bitOffset>0</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Request is cleared.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Request Compute Operation.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CPOACK</name>
<description>Compute Operation Acknowledge</description>
<bitOffset>1</bitOffset>
<bitWidth>1</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Compute operation entry has not completed or compute operation exit has completed.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Compute operation entry has completed or compute operation exit has not completed.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
<field>
<name>CPOWOI</name>
<description>Compute Operation Wake-up on Interrupt</description>
<bitOffset>2</bitOffset>
<bitWidth>1</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>No effect.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>When set, the CPOREQ is cleared on any interrupt or exception vector fetch.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>FPTA</name>
<description>General Purpose Input/Output</description>
<groupName>FGPIO</groupName>
<prependToName>FGPIOA_</prependToName>
<baseAddress>0xF8000000</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x18</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>PDOR</name>
<description>Port Data Output Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDO</name>
<description>Port Data Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Logic level 0 is driven on pin, provided pin is configured for general-purpose output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Logic level 1 is driven on pin, provided pin is configured for general-purpose output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PSOR</name>
<description>Port Set Output Register</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTSO</name>
<description>Port Set Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is set to logic 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PCOR</name>
<description>Port Clear Output Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTCO</name>
<description>Port Clear Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is cleared to logic 0.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PTOR</name>
<description>Port Toggle Output Register</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTTO</name>
<description>Port Toggle Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is set to the inverse of its existing logic state.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PDIR</name>
<description>Port Data Input Register</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDI</name>
<description>Port Data Input</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin logic level is logic 0, or is not configured for use by digital function.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin logic level is logic 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PDDR</name>
<description>Port Data Direction Register</description>
<addressOffset>0x14</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDD</name>
<description>Port Data Direction</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin is configured as general-purpose input, for the GPIO function.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin is configured as general-purpose output, for the GPIO function.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>FPTB</name>
<description>General Purpose Input/Output</description>
<groupName>FGPIO</groupName>
<prependToName>FGPIOB_</prependToName>
<baseAddress>0xF8000040</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x18</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>PDOR</name>
<description>Port Data Output Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDO</name>
<description>Port Data Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Logic level 0 is driven on pin, provided pin is configured for general-purpose output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Logic level 1 is driven on pin, provided pin is configured for general-purpose output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PSOR</name>
<description>Port Set Output Register</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTSO</name>
<description>Port Set Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is set to logic 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PCOR</name>
<description>Port Clear Output Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTCO</name>
<description>Port Clear Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is cleared to logic 0.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PTOR</name>
<description>Port Toggle Output Register</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTTO</name>
<description>Port Toggle Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is set to the inverse of its existing logic state.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PDIR</name>
<description>Port Data Input Register</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDI</name>
<description>Port Data Input</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin logic level is logic 0, or is not configured for use by digital function.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin logic level is logic 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PDDR</name>
<description>Port Data Direction Register</description>
<addressOffset>0x14</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDD</name>
<description>Port Data Direction</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin is configured as general-purpose input, for the GPIO function.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin is configured as general-purpose output, for the GPIO function.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
<peripheral>
<name>FPTC</name>
<description>General Purpose Input/Output</description>
<groupName>FGPIO</groupName>
<prependToName>FGPIOC_</prependToName>
<baseAddress>0xF8000080</baseAddress>
<addressBlock>
<offset>0</offset>
<size>0x18</size>
<usage>registers</usage>
</addressBlock>
<registers>
<register>
<name>PDOR</name>
<description>Port Data Output Register</description>
<addressOffset>0</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDO</name>
<description>Port Data Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Logic level 0 is driven on pin, provided pin is configured for general-purpose output.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Logic level 1 is driven on pin, provided pin is configured for general-purpose output.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PSOR</name>
<description>Port Set Output Register</description>
<addressOffset>0x4</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTSO</name>
<description>Port Set Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is set to logic 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PCOR</name>
<description>Port Clear Output Register</description>
<addressOffset>0x8</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTCO</name>
<description>Port Clear Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is cleared to logic 0.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PTOR</name>
<description>Port Toggle Output Register</description>
<addressOffset>0xC</addressOffset>
<size>32</size>
<access>write-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PTTO</name>
<description>Port Toggle Output</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>write-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Corresponding bit in PDORn does not change.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Corresponding bit in PDORn is set to the inverse of its existing logic state.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PDIR</name>
<description>Port Data Input Register</description>
<addressOffset>0x10</addressOffset>
<size>32</size>
<access>read-only</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDI</name>
<description>Port Data Input</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-only</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin logic level is logic 0, or is not configured for use by digital function.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin logic level is logic 1.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
<register>
<name>PDDR</name>
<description>Port Data Direction Register</description>
<addressOffset>0x14</addressOffset>
<size>32</size>
<access>read-write</access>
<resetValue>0</resetValue>
<resetMask>0xFFFFFFFF</resetMask>
<fields>
<field>
<name>PDD</name>
<description>Port Data Direction</description>
<bitOffset>0</bitOffset>
<bitWidth>32</bitWidth>
<access>read-write</access>
<enumeratedValues>
<enumeratedValue>
<name>0</name>
<description>Pin is configured as general-purpose input, for the GPIO function.</description>
<value>#0</value>
</enumeratedValue>
<enumeratedValue>
<name>1</name>
<description>Pin is configured as general-purpose output, for the GPIO function.</description>
<value>#1</value>
</enumeratedValue>
</enumeratedValues>
</field>
</fields>
</register>
</registers>
</peripheral>
</peripherals>
</device>