blob: a48dee5a8304d15e1046ee616a9820c3759bab33 [file] [log] [blame]
/*
* Copyright 2022 NXP
*
* SPDX-License-Identifier: Apache-2.0
*/
#include <stdlib.h>
#include <zephyr/kernel.h>
#include <zephyr/shell/shell.h>
#include <zephyr/drivers/uart.h>
#include <zephyr/drivers/regulator.h>
LOG_MODULE_REGISTER(regulator_shell, CONFIG_REGULATOR_LOG_LEVEL);
static int cmd_reg_en(const struct shell *sh, size_t argc, char **argv)
{
struct onoff_client cli;
const struct device *reg_dev;
int ret;
reg_dev = device_get_binding(argv[1]);
if (!device_is_ready(reg_dev)) {
shell_error(sh, "regulator device %s not available", argv[1]);
return -ENODEV;
}
ret = regulator_enable(reg_dev, &cli);
if (ret < 0) {
shell_error(sh, "failed to enable regulator, error %d", ret);
return ret;
}
shell_print(sh, "enabled regulator");
return 0;
}
static int cmd_reg_dis(const struct shell *sh, size_t argc, char **argv)
{
const struct device *reg_dev;
int ret;
reg_dev = device_get_binding(argv[1]);
if (!device_is_ready(reg_dev)) {
shell_error(sh, "regulator device %s not available", argv[1]);
return -ENODEV;
}
ret = regulator_disable(reg_dev);
if (ret < 0) {
shell_error(sh, "failed to disable regulator, error %d", ret);
return ret;
}
shell_print(sh, "disabled regulator");
return 0;
}
static int cmd_set_vol(const struct shell *sh, size_t argc, char **argv)
{
int lvol, uvol, ret;
const struct device *reg_dev;
reg_dev = device_get_binding(argv[1]);
if (!device_is_ready(reg_dev)) {
shell_error(sh, "regulator device %s not available", argv[1]);
return -ENODEV;
}
lvol = atoi(argv[2]) * 1000;
uvol = atoi(argv[3]) * 1000;
shell_print(sh, "Setting range to %d-%d uV", lvol, uvol);
ret = regulator_set_voltage(reg_dev, lvol, uvol);
if (ret < 0) {
shell_error(sh, "failed to set voltage, error %d", ret);
return ret;
}
ret = regulator_get_voltage(reg_dev);
if (ret < 0) {
shell_error(sh, "failed to read voltage, error %d", ret);
return ret;
}
shell_print(sh, "set voltage to %d uV", ret);
return 0;
}
static int cmd_set_ilim(const struct shell *sh, size_t argc, char **argv)
{
int lcur, ucur, ret;
const struct device *reg_dev;
reg_dev = device_get_binding(argv[1]);
if (!device_is_ready(reg_dev)) {
shell_error(sh, "regulator device %s not available", argv[1]);
return -ENODEV;
}
lcur = atoi(argv[2]) * 1000;
ucur = atoi(argv[3]) * 1000;
shell_print(sh, "Setting range to %d-%d uA", lcur, ucur);
ret = regulator_set_current_limit(reg_dev, lcur, ucur);
if (ret < 0) {
shell_error(sh, "failed to set current, error %d", ret);
return ret;
}
ret = regulator_get_current_limit(reg_dev);
if (ret < 0) {
shell_error(sh, "failed to read current, error %d", ret);
return ret;
}
shell_print(sh, "set current limit to %d uA", ret);
return 0;
}
SHELL_STATIC_SUBCMD_SET_CREATE(regulator_set,
SHELL_CMD_ARG(enable, NULL,
"Enable regulator\n"
"Usage: enable <device>", cmd_reg_en, 2, 0),
SHELL_CMD_ARG(disable, NULL,
"Disable regulator\n"
"Usage: disable <device>", cmd_reg_dis, 2, 0),
SHELL_CMD_ARG(set_vol, NULL, "Set voltage (in mV)\n"
"Usage: set_vol <device> <low limit (uV)> <high limit (uV)>",
cmd_set_vol, 4, 0),
SHELL_CMD_ARG(set_current, NULL, "Set current limit( in mA)\n"
"Usage: set_current <device> <low limit (uA)> <high limit (uA)>",
cmd_set_ilim, 4, 0),
SHELL_SUBCMD_SET_END
);
SHELL_CMD_REGISTER(regulator, &regulator_set, "Regulator Management", NULL);