blob: d558a7ffc093accb051b76777deb2e5d7f357b61 [file] [log] [blame]
# Common fields for CAN controllers
include: base.yaml
properties:
bus-speed:
type: int
required: true
description: bus speed in Baud/s
sjw:
type: int
required: true
description: Resynchronization jump width (ISO 11898-1)
prop-seg:
type: int
description: Time quantums of propagation segment (ISO 11898-1)
phase-seg1:
type: int
description: Time quantums of phase buffer 1 segment (ISO 11898-1)
phase-seg2:
type: int
description: Time quantums of phase buffer 2 segment (ISO 11898-1)
sample-point:
type: int
description: >
Sample point in permille.
This param is required if segments are not given.
If the sample point is given, the segments are ignored.
phys:
type: phandle
description: |
Actively controlled CAN transceiver.
Example:
transceiver0: can-phy0 {
compatible = "nxp,tja1040", "can-transceiver-gpio";
standby-gpios = <gpioa 0 GPIO_ACTIVE_HIGH>;
max-bitrate = <1000000>;
#phy-cells = <0>;
};
&can0 {
status = "okay";
phys = <&transceiver0>;
};
child-binding:
description: |
Passive CAN transceiver. The child node must be named "can-transceiver".
Example:
&can0 {
status = "okay";
can-transceiver {
max-bitrate = <1000000>;
};
};
properties:
max-bitrate:
type: int
required: true
description: |
The maximum bitrate supported by the CAN transceiver in bits/s.