# OSDP_NUM_CONNECTED_PD is used in CP mode. It is a constant set to 1 when
# operating as a PD.
config OSDP_NUM_CONNECTED_PD
int
default 1
help
In PD mode, number of connected PDs is is always 1 and cannot
be configured.
config OSDP_PD_COMMAND_QUEUE_SIZE
int "OSDP Peripheral Device command queue size"
default 16
help
The number of commands that can be queued to a given PD. In CP mode,
the queue size is multiplied by number of connected PD so this can grow
very quickly.
config OSDP_PD_ADDRESS
int "Peripheral Device Address"
default 1
range 1 126
help
The 7 least significant bits represent the address of the PD to which
the message is directed, or the address of the PD sending the reply.
Address 0x7F is reserved as a broadcast address to which all PDs would
respond.
if OSDP_SC_ENABLED
config OSDP_PD_SCBK
string "Secure Channel Base Key (SCBK)"
default "NONE"
help
Hexadecimal string representation of the the 16 byte OSDP PD Secure
Channel Base Key. When this field is sent to "NONE", the PD is set to
"Install Mode". In this mode, the PD would allow a CP to setup a secure
channel with default SCBK. Once as secure channel is active with the
default key, the CP can send a KEYSET command to set new keys to the PD.
It is up to the user to make sure that the PD enters the "Install Mode"
only during provisioning time (controlled environment).
endif # OSDP_SC_ENABLED
menu "Peripheral Device ID Information"
config OSDP_PD_ID_VENDOR_CODE
hex "PD Vendor Code"
default 0x001A2B3C
range 0 0x00FFFFFF
help
IEEE assigned OUI. Least 24 bits are valid.
config OSDP_PD_ID_MODEL
int "PD Product Model Number"
default 1
range 0 255
help
Manufacturer's model number. Least 8 bits are valid.
config OSDP_PD_ID_VERSION
int "PD Product Version"
default 1
range 0 255
help
Manufacturer's version of this product. Least 8 bits are valid.
config OSDP_PD_ID_SERIAL_NUMBER
hex "PD Serial Number"
default 0xCAFEBABE
range 0 0xFFFFFFFF
help
A 4-byte serial number for the PD.
config OSDP_PD_ID_FIRMWARE_VERSION
hex "PD Firmware Version"
default 0x00010100
range 0 0x00FFFFFF
help
Firmware revision code.
- Bit 0-7 : build version number;
- Bit 8-15 : minor version number;
- Bit 16-23: major version number;
endmenu # "PD ID Information"
menu "OSDP PD Capabilities"
menu "Contact Status Monitoring"
config OSDP_PD_CAP_CONTACT_STATUS_MONITORING_COMP_LEVEL
int "Compliance Level"
default 0
range 0 4
help
Possible values:
- 01: PD monitors and reports the state of the circuit without any
supervision. The PD encodes the circuit status per its default
interpretation of contact state to active/inactive status.
- 02: Like 01, plus: The PD accepts configuration of the encoding of the
open/closed circuit status to the reported active/inactive status. (User
may configure each circuit as "normally closed" or "normally open".)
- 03: Like 02, plus: PD supports supervised monitoring. The operating mode
for each circuit is determined by configuration settings.
- 04: Like 03, plus: the PD supports custom End-Of-Line settings within
the Manufacturer's guidelines.
config OSDP_PD_CAP_CONTACT_STATUS_MONITORING_NUM_ITEMS
int "Number of items"
default 0
help
The number of Inputs
endmenu # "Contact Status Monitoring"
menu "Output Control"
config OSDP_PD_CAP_OUTPUT_CONTROL_COMP_LEVEL
int "Compliance Level"
default 0
range 0 4
help
Possible values:
- 01: The PD is able to activate and deactivate the Output per direct
command from the CP.
- 02: Like 01, plus: The PD is able to accept configuration of the Output
driver to set the inactive state of the Output. The typical state of an
inactive Output is the state of the Output when no power is applied to the
PD and the output device (relay) is not energized. The inverted drive
setting causes the PD to energize the Output during the inactive state and
de-energize the Output during the active state. This feature allows the
support of "fail-safe/fail-secure" operating modes.
- 03: Like 01, plus: The PD is able to accept timed commands to the
Output. A timed command specifies the state of the Output for the
specified duration.
- 04: Like 02 and 03 - normal/inverted drive and timed operation.
config OSDP_PD_CAP_OUTPUT_CONTROL_NUM_ITEMS
int "Number of items"
default 0
help
The number of Outputs.
endmenu # "Output Control"
menu "LED Control"
config OSDP_PD_CAP_READER_LED_CONTROL_COMP_LEVEL
int "Compliance Level"
default 0
range 0 4
help
Possible values:
- 01: the PD support on/off control only
- 02: the PD supports timed commands
- 03: like 02, plus bi-color LEDs
- 04: like 02, plus tri-color LEDs
config OSDP_PD_CAP_READER_LED_CONTROL_NUM_ITEMS
int "Number of items"
default 0
help
The number of LEDs per reader.
endmenu # "LED Control"
menu "Audible Output"
config OSDP_PD_CAP_READER_AUDIBLE_OUTPUT_COMP_LEVEL
int "Compliance Level"
default 0
range 0 2
help
Possible values:
- 01: the PD support on/off control only
- 02: the PD supports timed commands
config OSDP_PD_CAP_READER_AUDIBLE_OUTPUT_NUM_ITEMS
int "Number of items"
default 0
help
The number of audible annunciators per reader
endmenu # "Audible Output"
menu "Text Output"
config OSDP_PD_CAP_READER_TEXT_OUTPUT_COMP_LEVEL
int "Compliance Level"
default 0
range 0 4
help
Possible values:
- 00: The PD has no text display support
- 01: The PD supports 1 row of 16 characters
- 02: the PD supports 2 rows of 16 characters
- 03: the PD supports 4 rows of 16 characters
- 04: TBD.
config OSDP_PD_CAP_READER_TEXT_OUTPUT_NUM_ITEMS
int "Number of items"
default 0
help
Number of textual displays per reader
endmenu # "Text Output"
menu "Card Data Format"
config OSDP_PD_CAP_CARD_DATA_FORMAT_COMP_LEVEL
int "Compliance Level"
default 0
range 0 3
help
Possible values:
- 01: the PD sends card data to the CP as array of bits, not exceeding
1024 bits.
- 02: the PD sends card data to the CP as array of BCD characters, not
exceeding 256 characters.
- 03: the PD can send card data to the CP as array of bits, or as an
array of BCD characters.
endmenu # "Card Data Format"
menu "Time Keeping"
config OSDP_PD_CAP_TIME_KEEPING_COMP_LEVEL
int "Compliance Level"
default 0
range 0 2
help
Possible values:
- 00: The PD does not support time/date functionality
- 01: The PD understands time/date settings per Command osdp_TDSET
- 02: The PD is able to locally update the time and date
endmenu # "Time Keeping"
endmenu # "OSDP PD Capabilities"