blob: 73e6adbaf27f4cd46c468b46d2f2592f8e4359ca [file] [log] [blame]
# ENS210 Digital Temperature and Humidity sensor configuration options
# Copyright (c) 2018 Alexander Wachter.
# SPDX-License-Identifier: Apache-2.0
menuconfig ENS210
bool "ENS210 Digital Temperature and Humidity sensor"
depends on I2C
help
Enable driver for ENS210 Digital Temperature and Humidity sensor.
if ENS210
choice
prompt "Temperature measurement mode"
default ENS210_TEMPERATURE_CONTINUOUS
help
Enable/disable temperature measurements and set measurement mode.
config ENS210_TEMPERATURE_OFF
bool "Disable temperature measurements"
config ENS210_TEMPERATURE_SINGLE
bool "Enable temperature measurements in single shot mode"
config ENS210_TEMPERATURE_CONTINUOUS
bool "Enable temperature measurements in continuous mode"
endchoice
choice
prompt "Humidity measurement mode"
default ENS210_HUMIDITY_CONTINUOUS
help
Enable/disable relative humidity measurements and set measurement mode.
config ENS210_HUMIDITY_OFF
bool "Disable relative humidity measurements"
config ENS210_HUMIDITY_SINGLE
bool "Enable relative humidity measurements in single shot mode"
config ENS210_HUMIDITY_CONTINUOUS
bool "Enable relative humidity measurements in continuous mode"
endchoice
config ENS210_CRC_CHECK
bool "Enable CRC Check"
default y
help
Check the crc value after data reading.
config ENS210_MAX_STAT_RETRIES
int "Number of status read retries"
default 4
help
Number of retries when status reading failed or device not ready.
config ENS210_MAX_READ_RETRIES
int "Number of value reading retries"
default 4
help
Number of retries when value reading failed, value not valid
or crc not ok.
endif # ENS210