| # Copyright (c) 2020 PHYTEC Messtechnik GmbH | 
 | # SPDX-License-Identifier: Apache-2.0 | 
 |  | 
 | menuconfig IEEE802154_DW1000 | 
 | 	bool "Decawave DW1000 Driver support" | 
 | 	default y | 
 | 	depends on DT_HAS_DECAWAVE_DW1000_ENABLED | 
 | 	select SPI | 
 |  | 
 | if IEEE802154_DW1000 | 
 |  | 
 | config IEEE802154_DW1000_SNIFF_ONT | 
 | 	int "SNIFF on time" | 
 | 	default 0 | 
 | 	range 0 15 | 
 | 	help | 
 | 	  SNIFF on time in unit of PAC. The minimum on time is the duration | 
 | 	  of two PACs. The SNIFF counter always adds 1 PAC unit to the on-time | 
 | 	  count. The SNIFF_ONT value should be in range of 1-15. | 
 | 	  Zero value disables SNIFF mode. | 
 |  | 
 | config IEEE802154_DW1000_SNIFF_OFFT | 
 | 	int "SNIFF off time" | 
 | 	default 16 | 
 | 	range 1 255 | 
 | 	help | 
 | 	  SNIFF off time in unit of approximate 1 microsecond. | 
 |  | 
 | config IEEE802154_DW1000_INIT_PRIO | 
 | 	int "DW1000 initialization priority" | 
 | 	default 80 | 
 | 	help | 
 | 	  Set the initialization priority number. Do not mess with it unless | 
 | 	  you know what you are doing. Beware DW1000 requires gpio and spi to | 
 | 	  be ready first (and sometime gpio should be the very first as spi | 
 | 	  might need it too). And of course it has to start before the net stack. | 
 |  | 
 | endif |