| .. zephyr:code-sample:: ccs811 |
| :name: CCS811 indoor air quality sensor |
| :relevant-api: sensor_interface |
| |
| Get CO2 equivalent and VOC data from a CCS811 sensor. |
| |
| Overview |
| ******** |
| |
| The CCS811 digital gas sensor detects volatile organic compounds (VOCs) |
| for indoor air quality measurements. VOCs are often categorized as |
| pollutants and/or sensory irritants and can come from a variety of |
| sources such as construction materials (paint and carpet), machines |
| (copiers and processors), and even people (breathing and smoking). It |
| estimates carbon dioxide (CO2) levels where the main source of VOCs is |
| human presence. |
| |
| Building and Running |
| ******************** |
| |
| Building and Running on thingy52/nrf52832 |
| ========================================= |
| |
| .. zephyr-app-commands:: |
| :zephyr-app: samples/sensor/ccs811 |
| :board: thingy52/nrf52832 |
| :goals: build flash |
| :compact: |
| |
| |
| Sample Output |
| ============= |
| |
| The sample output below is from a `Nordic Thingy:52 |
| <https://www.nordicsemi.com/Software-and-tools/Prototyping-platforms/Nordic-Thingy-52>`_ |
| (thingy52/nrf52832) that includes this sensor (and others). |
| After a soft reset, there is a 5-second startup period |
| where readings are unstable, and then we can see steady |
| reported measurements of about 400 ppm eC02 and 0 ppb eTVOC. |
| |
| .. code-block::console |
| |
| *** Booting Zephyr OS build zephyr-v2.1.0-310-g32a3e9907bab *** |
| device is 0x20001088, name is CCS811 |
| HW 12; FW Boot 1000 App 1100 ; mode 10 |
| |
| [0:00:00.046]: CCS811: 65021 ppm eCO2; 65021 ppb eTVOC |
| Voltage: 0.000000V; Current: 0.000000A |
| BASELINE fff4 |
| Timed fetch got 0 |
| |
| [0:00:01.059]: CCS811: 65021 ppm eCO2; 65021 ppb eTVOC |
| Voltage: 0.000000V; Current: 0.000000A |
| BASELINE fff4 |
| Timed fetch got 0 |
| Timed fetch got stale data |
| Timed fetch got stale data |
| Timed fetch got stale data |
| |
| [0:00:05.084]: CCS811: 400 ppm eCO2; 0 ppb eTVOC |
| Voltage: 0.677040V; Current: 0.000014A |
| BASELINE 8384 |
| Timed fetch got 0 |
| |
| [0:00:06.096]: CCS811: 405 ppm eCO2; 0 ppb eTVOC |
| Voltage: 0.675428V; Current: 0.000014A |
| BASELINE 8384 |
| Timed fetch got 0 |
| |
| [0:00:07.108]: CCS811: 400 ppm eCO2; 0 ppb eTVOC |
| Voltage: 0.677040V; Current: 0.000014A |
| BASELINE 8384 |
| Timed fetch got 0 |
| |
| [0:00:08.121]: CCS811: 400 ppm eCO2; 0 ppb eTVOC |
| Voltage: 0.677040V; Current: 0.000014A |
| BASELINE 8384 |
| Timed fetch got 0 |
| |
| [0:00:09.133]: CCS811: 400 ppm eCO2; 0 ppb eTVOC |
| Voltage: 0.677040V; Current: 0.000014A |
| BASELINE 8384 |
| Timed fetch got 0 |
| |
| [0:00:10.145]: CCS811: 400 ppm eCO2; 0 ppb eTVOC |
| Voltage: 0.677040V; Current: 0.000014A |
| BASELINE 8384 |
| Timed fetch got 0 |