| # Kconfig - TMP112 temperature sensor configuration options |
| |
| # |
| # Copyright (c) 2016 Firmwave |
| # |
| # SPDX-License-Identifier: Apache-2.0 |
| # |
| |
| menuconfig TMP112 |
| bool |
| prompt "TMP112 Temperature Sensor" |
| depends on SENSOR && I2C |
| default n |
| help |
| Enable driver for TMP112 infrared thermopile sensors. |
| |
| config TMP112_NAME |
| string |
| prompt "Driver name" |
| default "TMP112" |
| depends on TMP112 |
| help |
| Device name with which the TMP112 sensor is identified. |
| |
| config TMP112_I2C_ADDR |
| hex "I2C address for TMP112" |
| depends on TMP112 |
| default 0x48 |
| help |
| I2C address of the TMP112 sensor. |
| |
| 0x48: A0 connected GND and A1 connected to GND. |
| 0x49: A0 connected VDD and A1 connected to GND. |
| 0x4A: A0 connected SDA and A1 connected to GND. |
| 0x4B: A0 connected SCL and A1 connected to GND. |
| |
| |
| config TMP112_I2C_MASTER_DEV_NAME |
| string |
| prompt "I2C master where TMP112 is connected" |
| depends on TMP112 |
| default "I2C_0" |
| help |
| Specify the device name of the I2C master device to which the |
| TMP112 chip is connected. |