# Copyright (c) 2022, Prevas A/S
# SPDX-License-Identifier: Apache-2.0
description: NXP MCUX QDEC
compatible: "nxp,mcux-qdec"
include: [pinctrl-device.yaml, sensor-device.yaml]
properties:
reg:
required: true
interrupts:
required: true
counts-per-revolution:
type: int
required: true
description: |
This is a number that is used to determine how many revolutions
were done based on the current counter's value.
single-phase-mode:
type: boolean
description: |
Bypass the quadrature decoder. A positive transition of the PHASEA input
generates a count signal. The PHASEB input and the REV bit control the
counter direction.
filter-count:
type: int
enum: [0, 1, 2, 3, 4, 5, 6, 7]
description: |
The number of consecutive samples that must agree prior to the input
filter accepting an input transition. A value of 0 represents 3
samples. A value of 7 represents 10 samples.
filter-sample-period:
type: int
description: |
The sampling period (in IPBus clock cycles) of the decoder input signals.
Each input is sampled multiple times at the rate specified by the Filter
Sample Period. If FILT_PER is 0 (default), then the input filter is
bypassed. Bypassing the digital filter enables the position/position
difference counters to operate with count rates up to the IPBus
frequency. Turning on the input filter introduces a latency of:
((FILT_CNT + 3) * FILT_PER) FILT clock cycles + 2 IPBus clock periods.
xbar:
type: phandle
required: true
description: |
The xbar phandle.