| # MCP320x ADC configuration options |
| |
| # Copyright (c) 2020 Vestas Wind Systems A/S |
| # SPDX-License-Identifier: Apache-2.0 |
| |
| config ADC_MCP320X |
| bool "MCP3204/MCP3208 driver" |
| default y |
| depends on DT_HAS_MICROCHIP_MCP3204_ENABLED || DT_HAS_MICROCHIP_MCP3208_ENABLED |
| select SPI |
| help |
| Enable MCP3204/MCP3208 ADC driver. |
| |
| The MCP3204/MCP3208 are 4/8 channel 12-bit A/D converters |
| with SPI interface. |
| |
| if ADC_MCP320X |
| |
| config ADC_MCP320X_ACQUISITION_THREAD_STACK_SIZE |
| int "Stack size for the ADC data acquisition thread" |
| default 512 |
| help |
| Size of the stack used for the internal data acquisition |
| thread. |
| |
| config ADC_MCP320X_ACQUISITION_THREAD_PRIO |
| int "Priority for the ADC data acquisition thread" |
| default 0 |
| help |
| Priority level for the internal ADC data acquisition thread. |
| |
| endif # ADC_MCP320X |